ML043220094
| ML043220094 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek (DPR-016) |
| Issue date: | 11/16/2004 |
| From: | NRC/NRR/DLPM |
| To: | |
| References | |
| TAC MC4205 | |
| Download: ML043220094 (1) | |
Text
-SECTION 2 SAFETY LIMITS AND LIMITING SAFETY SYSTEM SETTINGS 2.1 SAFETY LIMIT - FUEL CLADDING INTEGRITY Applicability: Applies to the interrelated variables associated with fuel thermal behavior.
Oblective:
To establish limits on the important thermal hydraulic variables to assure the integrity of the fuel cladding.
Specifications:
A.
When the reactor pressure is greater than or equal to 800 psia and the core flow is greater than or equal to 10% of rated, the existence of a minimum CRITICAL POWER RATIO (MCPR) less than 1.10 for both four or five loop operation and 1.12 for three loop operation shall constitute violation of the fuel cladding integrity safety limit.
B.
When the reactor pressure is less than 800 psia or the core flow is less than 10%
of rated, the core thermal power shall not exceed 25% of rated thermal power.
.C.
In the event that reactor parameters exceed the limiting safety system settings in Specification 2.3 and a reactor scram is not initiated by the associated protective instrumentation, the reactor shall be brought to, and remain in, the COLD SHUTDOWN CONDITION until an analysis is performed to determine whether the safety limit established in Specification 2.1.A and 2.1.B was exceeded.
D.
During all modes of reactor operation with irradiated fuel in the reactor vessel, the water level shall not be less than 4'8" above the TOP OF ACTIVE FUEL.
I OYSTER CREEK 2.1-1 Amendment No.: 75,135,192,22,218, 228,233,238, 252