2RE08 INSERVICE INSPECTION

SUMMARY

REPORT FOR STEAM GENERATOR TUBING of the SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 2 P.O. BOX 289 WADSWORTH, TEXAS 77483 Owner: South Texas Project Nuclear Operating Company Commercial Operation:

June 19, 1989 Issue Date:

JUNE 2001

2RE08 INSERVICE INSPECTION

SUMMARY

REPORT FOR STEAM GENERATOR TUBING of the SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNIT 2 USNRC DOCKET NO.:

50-499 OPERATING LICENSE NO.:

NPF-80 COMMERCIAL OPERATION DATE: June 19, 1989 Prepared By:

J.L. Haning Date ISI Engineer - Steam Generator Tubing Approved By:

M. E. Kanavos Date Project Engineering Manager - Steam Generators

TABLE OF CONTENTS Page No.

1.0 Introduction 2.0 Scope of Examinations 3.0 Personnel, Procedures and Equipment 3.1 Personnel Qualifications 3.2 Examinations and Analysis Procedures 3.3 Equipment 3.4 Calibration Standards 4.0 Summary of Examinations 5.0 Examination Results and Corrective Actions 5.1 Steam Generator A 5.2 Steam Generator B 5.3 Steam Generator C 5.4 Steam Generator D 6.0 Certification of Inspections Appendix A Appendix B Appendix C Appendix D Appendix E Appendix F List of Examination and Data Analysis Personnel Tubes Examined by MRPC at Locations Other Than TSH Dents and Dings Tubes with Tube Wall Thickness Reduction Tubes Removed from Service Prior to and During 2RE08 Owner's Report for Inservice Inspection - NIS - 1 Form iii 1

2 4

4 4

5 6

7 8

9 9

10 10 13

STEAM GENERATOR TUBE EXAMINATIONS 1.0 Introduction This Summary Report describes the South Texas Project Nuclear Operating Company's (STPNOC's) Inservice Inspection (ISI) of the steam generator (S/G) tubing at the South Texas Project Electric Generating Station, Unit 2 (STPEGS-2) during the 2RE08 refueling outage.

The steam generator tube ISI is required by Sections 3/4.4.5 and 4.0.5 of the Technical Specifications to be performed in accordance with the edition and addenda of the American Society of Mechanical Engineers (ASME)

Section XI Code "Inservice Inspection of Nuclear Power Plant Components" prescribed by Title 10 of the Code of Federal Regulations, Part 50, Section 50.55a(g). Therefore, the ISI is required to meet the 1989 Edition of the ASME Code Section XI. The ISI summarized herein constitutes the first ISI performed during the second 10 Year Inspection Interval. The 2RE08-steam generator tubing ISI commenced on March 11, 2001 and was completed on March 28, 2001.

The STPEGS-2 ISI for the second 10 year inspection interval is described in the "Inservice Inspection Program Plan for the Second Interval of the South Texas Project Electric Generating Station, Units 1 and 2, Steam Generator Tubing". This letter has previously been filed with the Nuclear Regulatory Commission (NRC) and the State Of Texas. The STPEGS-2 program was developed and is being implemented in accordance with 1 OCFR50.55a, IWB (Examination Category B-Q) of the 1989 Edition of the ASME Section XI Code, STPEGS Technical Specification 4.4.5, and other regulatory and Code cases as specified in the ten year ISI plan for the second inspection interval.

This Summary Report satisfies the reporting requirements of ASME Code Section XI, IWA-6000 and 4.4.5.5 (b) of the STPEGS Technical Specification.

Section 3/4.4.5 of the Technical Specifications also provide Alternate Repair Criteria (ARC) for outer diameter stress corrosion cracking at tube support plates. This report discusses aspects of the implementation of ARC in Unit

2. Two separate reports discuss the implementation of the ARC for outer diameter stress corrosion cracking at tube support plates in detail and respond to the requirements of Westinghouse Nuclear Service Division (WNSD)

Document - SG-98-01-004, "Technical Justification for License Amendment to Implement NRC Generic Letter GL 95-05: Voltage Based Repair Criteria, Steam Generator Tube ODSCC", and WNSD Document - WCAP 15163, Revision 1, "Technical Support for Implementing High Voltage Alternate Repair Criteria at Hot Leg Limited Displacement TSP Intersections for South Texas Project Unit 2 Model E Steam Generator". The first report describes the implementation of a 1.0-volt ARC for all support plate elevations, while the second report describes implementation of a 3.0 volt ARC only for the second (02H), third (03H), and fourth (04H) hot leg support plates.

The STPEGS-2 plant design contains four (4) Westinghouse recirculating design model E2 steam generators. Each model E2 steam generator was designed and fabricated by Westinghouse Electric Corporation of Tampa, Florida.

Each steam generator contains 4864 drilled holes in the tubesheet. Of these holes, thirteen (13) were plugged to permit the installation of additional stay rods in the preheater section of each steam generator. Therefore, each steam generator contained 4851 inservice tubes at initial operation. The tubing material is low temperature mill annealed ASTM SB-163 Inconel having a nominal outer diameter (OD) of 0.750 inch and nominal wall thickness of 0.043 inch. The nominal thickness of the tubesheet is 22.65 inches.

The examination agency for the 2RE08 outage was Westinghouse Electric, LLC.

1

2.0 Scope of Examinations The STPEGS-2 ten year ISI plan for the second inspection interval describes the ISI program for examination of steam generator tubing. Additionally, an auxiliary ISI plan (ISI Outage Plan) entitled, "2001 Outage Plan for the In service Inspection of Steam Generator Tubing at the South Texas Project Electric Generating Station Unit 2",

including Change Number 001, was prepared by Westinghouse and approved by STPNOC. The ISI Outage Plan identified the steam generator tube areas to be examined by eddy current testing (ET) and the ET procedures expected to be used during the ISI.

A Degradation Assessment (DA) was written prior to the outage. This document identified necessary examination techniques. An evaluation of these techniques was performed to ensure their qualification. Finally, a site appropriateness review was conducted to satisfy that each technique could be used in STPNOC Unit 2 Steam Generators. All techniques were reviewed for use by the Westinghouse Level III QDA, the STP ISI engineer, and the STP QDA.

The initial scope consisted of the following planned examinations:

Bobbin coil ET of all in-service tubing over its full length, except for the Rows 1 and 2 U-bend section, in each steam generator. In addition to the evaluation for tubing degradation, a single auto-analysis was to be performed for an evaluation of the following: (1) dents greater than 2.0 volts, and (2) interfering signals, e.g., mixed residuals, copper signals, etc., that could cause misinterpretation of an Outside Diameter Stress Corrosion Cracking (ODSCC) signal at a tube support plate intersection.

The hot leg top of tubesheet inspection program consisted of approximately 34% of the in-service tubes in each steam generator. The 34% includes approximately 850 tubes near the Flow Distribution Baffle, FDB cut-out (a critical area) and a 20% random sample of the remaining in-service at the top of tubesheet.

These exams were conducted with an RPC probe design containing a 0.115" diameter pancake, a +Pt coil (differentially connected axial and circumferentially oriented coils) and a shielded high frequency pancake coil known as 3C+PtRPC probe. The area of interest examined extended approximately three (3) inches above to three (3) inches below the secondary face of the tubesheet. Also, a 3C+PtRPC examination of 20% of the expanded tube locations in the preheater baffle plate area was performed. The area of interest examined extended approximately plus/minus (2) inches around the baffle plate centerline.

"* A single, mid-frequency range plus point coil (I C+PtRPC) ET of the U-bend section of 100% of all the tubes in Row 1 and 20% of all tubes in Row 2. The area to be examined extended from the uppermost tube support plate on the cold leg side to the uppermost tube support on the hot leg side of the bundle.

"* Several 3C/1 C+Pt RPC ET programs were planned to examine ding indications as follows:

I.

All dings greater than 5 volts anywhere in the entire tube length.

2.

A "ding pair" is defined as two dings that are separated by an axial distance of 0.75 to 1.5 inches located in the H/L or C/L straight lengths. They are believed to be caused by side loads at support plates during tube installation. In all four-steam generators, 20% of the "ding pairs" in each steam generator located between the top supports on both the hot leg (09H and I OH) and the cold leg (11 C and 12C) were tested.

3.

In all four steam generators, 20% of all dings between, but not including, the hot leg top of tubesheet interface (TSH) and the first full support plate elevation, 02H.

"* In these 3 ding ET programs, as applicable, the overlap of inspection categories selected above was counted as satisfying one or the other categories. All of the inspections would extend over an approximate length of four (4) inches, as a minimum.

2

As required by the ARC program, DSI's exceeding 3.0 volts at support plate elevations 02H, 03H, and 04H, plus all DSI's that exceed 1.0 volts for all other support elevations will be subjected to a 3-coil +Pt RPC inspection. Those that confirmed were identified for repair. Also in accordance with the ARC program, all Dent's > 5 volts shall be inspected with a +Pt RPC for evidence of PWSCC.

This scope exceeded the requirements for the first ISI sample of tubes specified in 4.4.5.2 of the STPEGS technical specification (NUREG - 1346). Further, the ISI Outage Plan is consistent with the requirements of the Steam Generator Tube Ten-Year ISI Plan for the Second Inspection Interval.

Tube degradation reported during the examination led to expanding some of the initial sampling programs. The expanded scope consisted of the following examinations:

1. The number of Row 2 inspections in Steam Generator D increased from 20% to 100%.
2.

The hot leg expansion transition inspection with a 3C+Pt Coil was increased from approximately 34%

to 100% in all steam generators.

3.

The inspection program in Steam Generator C of the expanded cold leg supports increased from 20%

to 100%.

4.

In Steam Generator D the ding pair examination was increased to 100% located in each leg.

Additionally, STP elected to examine 20% of the cold leg ding pairs outside the initial defined scope in each of the remaining three steam generators.

3

3.0 Personnel, Procedures, and Equipment 3.1 Personnel Qualifications The personnel who performed the ET acquisition and analysis during the 2RE08 outage were employed by Westinghouse, NDE Technology, Quantum NDE Services, Core Star International, Duke Engineering Services, MoreTech, ANATECH International, Rockridge Technology and Framatome Technology (FTI). They were certified in accordance with the requirements of IWA-2300 of ASME Code Section XI and the certification practices of their respective employers. One hundred (100) percent of the ET analysts were certified as Qualified Data Analysts (QDA's) for the steam generator work performed. A QDA is a Level IIA or III who has passed rigorous testing of his ability to analyze a random selection of expertly-judged indications, from the Electric Power Research Institute's "PWR Steam Generator Examination Guidelines", Appendix G Performance Demonstration Database, for various steam generator designs and all types of known defects.

Before an ET data analyst could perform any analysis during 2REO8, they were required to successfully complete a STPEGS Site Specific Performance Demonstration (SSPD) steam generator ET data analysis-training program. The analyst-training program consisted of (1) ET data analysis course and (2) site specific practical training. The ET data analysis course consisted of Computer Based Training (CBT) on CD-ROM and the analysis procedures. The CBT course addressed the specific STPEGS steam generator design, operating history, previous ET results, the data acquisition procedure, and analysis procedures to be used for the STPEGS Unit 2 ET examinations. The site specific practical training included hands-on review of flaw indications for the damage mechanisms that have been identified at STPEGS. Successful completion of the SSPD required the passing of a written and a practical test, which could be limited to either bobbin coil, MRPC or both, depending on staffing assignments.

For personnel involved in the performance of the ET acquisition and/or data analysis, their certification levels and identification numbers are listed in Appendix A. The identification numbers of the personnel that acquired or analyzed the ET data for a specific examination are recorded on the optical disks and data sheets. The identification number typically consists of the first letter of the person's last name and the last four digits of their social security number.

3.2 Examination and Analysis Procedures All ET inspections were performed in accordance with the WNSD procedure MRS 2.4.2 GEN-35, Revision 9 entitled, "Eddy Current Inspection of Preservice and Inservice Heat Exchanger Tubing", with Field Change Request Number I. This procedure, with the change authorization, is STPEGS document no. 0120-09-00036-FWN.

The bobbin coil examination technique was performed using inspection frequencies of 550, 300, 130 and 20 kHz in both the differential and absolute modes for each tube. The Westinghouse bobbin coil procedure is an alternative to the technique described in ASME Code Section V, Article 8, 1-872, which requires that the probe pull speed not exceed 14 inches per second, without being demonstrated to the satisfaction of the Authorized Nuclear Inservice Inspection (ANII).

A nominal pull speed of 40 inches per second with a digital signal-sampling rate of 1400 samples per second or greater, as defined in Table I of Paragraph 7.4.13 of MRS 2.4.2 GEN-35 was used during the 2RE08 ET examination. Acquisition Technique Sheet (ACT) THX-01 listed these and other essential variables required for bobbin probe testing. Additionally, a slower test speed was used as needed to reduce probe snap in u-bend areas.

This slower nominal pull speed of 24 inches per second used a digital signal sample rate of 850 samples per second or greater, and is listed on ACTS THX-01A.

The 3C+Pt probe was used in the straight length and TTS and the 1C+Pt probe was used in all u-bend programs requiring RPC inspection. Three-coil and single +Pt RPC ET examination techniques were performed using the examination frequencies of 300, 200, 100, and 10 kHz. Also, the high frequency pancake coil on the 3-coil probe 4

head was operated at 600 kHz, in addition to 300 kHz. The 3-coil and single coil +Pt test specifications are covered on ACT Sheets THX-02/02A/02B and THX-03/03A, respectively..

The ET data analysts performed the analysis per Westinghouse procedure NSD-FP-1997-8053 Rev. 4, titled, "Steam Generator Eddy Current Data Analysis ", STPEGS document number 0120-090077-EWN, with Field Changes 001 and 002. All bobbin coil and RPC ET data for each steam generator tube or tube area examined were subjected to two (2) separate independent analyses in accordance with the analysis procedure. A single auto-analysis of the bobbin coil data was performed to evaluate the following: (1) dents at TSP's equal to or greater than 2.0 volts and (2) and Mixed Residual Indications (MRI's) which are interfering signals, e.g., mix residuals, copper signals, etc.,

that could cause misinterpretation of an ODSCC signal at a tube support plate intersection.

Westinghouse and its subcontractors performed the primary analysis in accordance with STPEGS document no.

01 20-090077-EWN, with Field Changes 001 and 002. FTI and it's subcontractors performed the secondary analysis in accordance with the FTI procedure 54-ISI-400-11 entitled "Multi-frequency Eddy Current Examination of Tubing" including Safety Document Change Notice number 30-5011160-00. This FTI Procedure is STPEGS document No. ST401280-00231-B2U.

The primary, secondary and resolution data evaluation for degradation was performed manually by the analysts using Zetec's Eddynet98 software. A single, auto-analysis for dents > 2.0 volts, plus interfering signals at support plate elevations (i.e. mixed residual signals, copper deposits) was performed using Computer Data Screening (CDS) routines of the Eddynet98 software. The ET primary and secondary data analysis was performed in separate facilities. Primary and CDS analysts were located at Westinghouse's Remote Eddy Current Data Analysis Center (REDAC) in Madison, PA. The secondary analysts were located at Framatome in Lynchburg, VA, Rockridge in Benicia, CA, and at Duke Engineering Services in North Carolina.

Results of all of the eddy current examinations were recorded on a digital, rewritable optical disk and the final resolution data sheets, which are stored as records. Each disk contains the raw ET data, primary, secondary, and resolution results for each calibration group. The optical disks also contain the system calibration and calibration verification with the dates and times for each calibration and verification. The unique number of the digital rewritable optical disk and the calibration group number have been recorded on the data sheets and optical disks.

Therefore, the system calibration and calibration verification of the raw signals for each tube examined can be easily recalled.

3.3 Equipment All examinations were performed using ANSER ROSA 3-Version 8.3 Rev 76 released software and the TECHRAD TC-6700 test instrument. The acquisition test instrument and software store and process the ET data in a digital format and have a significantly improved dynamic range and signal-to-noise ratio as compared to analog systems.

The test system is capable of being operated at locations remote from the steam generators (e.g., in low radiation areas). All analysis was performed using Eddynet98 Version 1.0 Patch 42 software.

The straight lengths in both legs of tubes in rows 1 and 2 were tested separately from the hot and cold leg tube ends with a 0.610-inch magnetic-biased diameter bobbin coil probe. A small number of Row 3 u-bends were tested with at 0.590-inch diameter bobbin probe. For all other tubes, the bobbin ET examinations were performed full length with a 0.610-inch diameter magnetic-biased probe.

The rows I and 2 u-bend RPC program was conducted with a 0.580 inch diameter probe containing a magnetically biased single +Point coil. This probe was also used to inspect freespan dings and non-quantifiable indications (NQI's) situated in the u-bend within 18 inches of the top TSP in either leg. In addition, IC+Pt RPC probes of 36",

60" and 96" length were used, as necessary, to inspect dings in larger radius u-bends.

In conducting RPC ET at TSP's for those bobbin coil indications related to Alternate Repair Criteria, straight length DNG's orNQI's and during the TSH program, a 0.610-inch diameter 3C+PtRPC probes was used. This RPC probe consists of one (1) plus-point coil (interwoven axially and circumferentially oriented coils that are differentially 5

connected), one (1) 0.115 inch diameter pancake coil and one (1) shielded high frequency 0.080 inch diameter pancake coil. These inspections took place from either leg, depending on the location requiring inspection.

3.4 Calibration Standards The calibration standard design used for bobbin coil inspections was a combination in-line standard. It contained ASME Code Section XI flaws, drill holes for measuring probe wear, simulated AVB wear flaws, a small dent and both carbon steel and stainless steel support rings. The calibration standard utilized for all of the 3-coil and Plus point MRPC inspections was a guide tube design containing several ID and OD, axially and circumferentially oriented, electro-discharge machined (EDM) notches in sufficient quantities to permit the sizing of indications if necessary. Also, baffle plate wear scar standards were used to size wear indications at the preheater baffle plates in the cold leg.

6

4.0 Summary of Examinations Bobbin coil ET techniques were performed on one hundred (100) percent of all in-service tubes in each of Steam Generators A, B, C, and D. All of these tubes were examined over their full length (FL), from tube end to tube end, except for the Rows 1 and 2 u-bends. One hundred percent of the Row 1 u-bends, 100% of the Row 2 u-bends in SG D, and 20% of the Row 2 u-bends in the other steam generators were tested with 1C+PtRPC probes. A 3C+PtRPC ET examination was conducted on 100% of the hot leg top of the tubesheet intersections in all steam generators. Further, a 3C+PtRPC inspection of a 20% sample of the tube expansions in the preheater baffle plate area were performed in Steam Generators A, B, and D; while 100% of the tube expansions in Steam Generator C were tested. The following table summarizes the quantities of tubes that were examined by the various techniques/locations noted, except for the freespan and TSP programs discussed below:

SG Bobbin Coil 100% TSH Row I Row 2 Expanded Baffle Full Length RPC U-bend RPC U-bend RPC Plate RPC A

4655 4655 119 24 64 B

4632 4632 119 24 64 C

4615 4615 119 24 321 D

4633 4633 118 119 64 All MRPC exams performed, not at the hot leg tubesheet interface, are listed in Appendix B. A 3C+PtRPC ET was conducted at the various tube locations. The listings of Appendix B includes, in part, all locations where bobbin coil ET indicated a signal which may be (1) possible ODSCC exceeding 3.0 volts at hot leg TSP's 02H, 03H, and 04H; (2) possible ODSCC exceeding 1.0 volt at all other support plate elevations; (3) a dent (DNT) at a TSP exceeding 5.0 volts; or (4) an interfering signal (MRI), e.g., copper or mixed residual of sufficient magnitude to cause a 1.0 volt ODSCC indication to be missed or misinterpreted as required by STPEGS ARC program for TSP's.

In addition, Appendix B includes all freespan (both the straight lengths and the u-bend area) and non-quantifiable ET indications, e.g., NQI, DNI, etc., which could not be verified to be present in baseline data, that were examined by +Pt RPC for final disposition. Further, all freespan dings greater than 5.0 volts and selected freespan dings as defined in the programs noted above to ensure there was no cracking (Circumferential or Axial) being masked by the dings are also listed in Appendix B and tested with a 3C+PtRPC probe. The freespan dings in the following programs were tested.

Steam

> 5 Volts -

Ding Pairs -

DNG's in Freespan between TSH Generator Any Location*

All Locations*

and 02H*

Tubes/DNG's Tubes / DNG'S Tubes/DNG's/DNG Pairs A

44/52 7/16 19/20/1 B

40/45 17/38 19/21/0 C

37/52 11/31 25/25/0 D

65/84 116/433 21/22/0 Totals 186/233 151/518 84/88/1

  • Dings that were > 5 Volts are included in the other program counts, but are noted as to the quantity. Further, 12 newly reported dings > 5 Volts found during 2RE08 were tested, but are not included in the above counts. The majority of these dings were reported previously as being just under 5.0 volts. The remainder are reported in the u bend region of rows 4 to 13. Any ding pairs that are a part of the TSH-02H program are not separated in the above tabulation. Because of the overlap of programs and/or the addition of newly reported dings, the total actual quantity of dings inspected may be less or greater than any summation of the above.

Appendix C contains a listing of all dents greater than 2.0 volts and all dings greater than 0.75 volts that exist in the database. These results were generated during the outage evaluation of dings and dents.

7

5.0 Examination Results and Corrective Actions The location of the indications were recorded relative to the adjacent tube support, baffle plate and/or anti-vibration bar. The tube support plates and baffle plates were numbered consecutively from 01 H to 1 OH (on the hot leg) and from 11 C to 23C (on the cold leg) starting on the hot leg side, over the U-bend, and down the cold leg side of the steam generator. The anti-vibration bars were numbered AVI, AV2, AV3, and AV4 from the hot leg to the cold leg side, respectively. Indications in the tubesheet area were recorded relative to TEH or TSH (hot leg) or TEC or TSC (cold leg) depending on whether the indications were at the tube end (E) or secondary face (S).

In addition, the vertical distances from these landmarks to flaws were recorded, with positive being upward from the reporting structure. This convention was used through out the tube bundle, except at support structures, where a plus/minus 2-inch window was used when reporting indications that were at or near the support structure.

Indications that were contributed to wear (AVB's and preheater baffle plates) are reported as percent through wall values in this report. Other ET indications contained in this report were assigned three letter codes. The indication codes reflect the suspected nature of the discontinuity. Some of the codes used are as follows:

DNG - ding, located in freespan only DNI - ding or dent containing a possible indication DNT - dent, located at TSP's only DSI - distorted support with possible flaw indication MAI - multiple axial indication MBM - manufacturing buff mark MCI - multiple circumferential indications MRI - mixed residual indications MVI - multiple volumetric indication NQI - non-quantifiable indication SAI - single axial indication SCI - single circumferential indication SVI - single volumetric indication Lists, including the locations and depths, of all flaw indications that were characterized as reductions in the tube wall thickness are contained in Appendix D. Also included in Appendix D are the SAI, SCI, MAI and MCI indications reported during RPC testing. SAI, SCI, MAI and MCI indications are expected to be the result of cracks. These indication classifications are considered to be reductions in the tube wall thickness. All of these indications were plugged regardless of depth.

In January 1997, a review of previously called free span indications, except dings, was performed to establish traceability of these already identified signals to the baseline bobbin coil data. In addition, during the 2RE05, 2RE06, 2RE07, and 2RE08 outages, any free span call that did not have a corresponding record of a baseline call was also subjected to a review of the baseline data. The purpose of this effort was to let those tubes with corresponding signals in the baseline, which had not changed, to remain in service.

During 2RE08, newly reported freespan indications that were found to be in the baseline bobbin data, and having not changed, were re-identified as Manufacturing Buff Marks (MBM's). Those that could not be traced to baseline were then subjected to a RPC inspection. Several axially oriented indications were found in the freespan sections of tubing at ding locations. These tubes are also listed in Appendix D. Also, circumferentially oriented indications were found during the freespan RPC program at a paired ding.

Circumferential indications were reported at the hot leg top of tubesheet expansion transition in all four-steam generators. Each indication was detected during the 3C+PtRPC inspection. Further, no axial indications were reported within the tubesheet or at the top of tubesheet interface.

8

As required by the ARC program, all DSI's at support plate elevations 02H, 03H, and 04H that exceeded 3.0 volts were subjected to a 3-coil +Pt RPC inspection. All of these tubes were entered onto the repair list, per the ARC requirement, regardless of the +Point RPC results. Any DSI with a voltage exceeding 1.0 volts at any other support plate elevation was also examined with a 3-coil +Pt RPC probe. Those DSI's that confirmed as flaws were identified for repair. Additionally, all reported MRI's 1.5 volts and greater were examined by RPC.

Also in accordance with the ARC program, all dent's > 5 volts were inspected with a +Pt coil for evidence of PWSCC, of which none was found.

Prior to the 2RE08 outage, leakage was being tracked in all four-steam generators. Both STP and Westinghouse engineers believed that ODSCC at tube support plate intersections was the cause of the leakage. STP and Westinghouse assembled a program designed to minimize normal operating leakage during the next cycle. This program led to testing of 804 additional DSI's with voltages between 0.6 and 1.5 volts at support plates 02H, 03H, and 04H. These tests were performed with a 3-coil +Pt RPC probe. A line-by-line profile analysis was then performed on each axial flaw. Analysts who performed the profile analysis received additional training and testing prior to the inspection. Profile results were used for creation of a preventative plugging list. This led to a decision to preventatively plug those DSI's > 1.5 volts at support plates 02H, 03H, and 04H.

No copper deposits, circumferential cracks at tube support plates, or either bobbin coil or RPC testing detected axial cracks extending beyond the edge of the tube support plates. Permeability variations (PVN) that transcended any TSP, Baffle Plate, or hot leg tubesheet expansion, and were determined to possibly mask a flaw signal, were removed from service.

Following eddy current testing a tube support plate locking program was performed. The support plates locked in each steam generator were coincident with 02H, 03H, and 04H. All tubes that support plate locking occurred were added to the repair list.

The total numbers of degraded and defective tubes detected during the bobbin coil ET and MRPC ET are as follows:

5.1 Steam Generator A A total of thirty-five (35) tubes were considered defective as defined by the Technical Specification 4.4.5.4.

Twenty-three (23) tubes were plugged for confirmed bobbin DSI indications at support plate elevations. Seven (7) tubes were removed from service for freespan axially oriented crack like indications. Three (3) tubes were plugged for circumferentially oriented crack like indications at the top of tubesheet expansion. Two (2) tubes were plugged for volumetric indications reported in freespan tubing. No other tubes were degraded.

Steam Generator A had no tubes with degradation detected by RPC in the Row I and 2 u-bends, or the expanded preheater baffle plate program.

Two hundred eleven (211) tubes were preventatively plugged. One hundred sixty eight (168) tubes were repaired for bobbin DSI signals that do not exceed the ARC voltage requirement. Twenty (20) were suspected leaking tubes.

Twenty-two (22) tubes because of support plate locking. One (1) tube was plugged for a permeability variation response that spanned the top of tubesheet expansion.

5.2 Steam Generator B A total of twenty-three (23) tubes were considered defective as defined by the Technical Specification 4.4.5.4.

Twenty (20) tubes were plugged for confirmed bobbin DSI indications at support plate elevations. One (1) tube was removed from service for a freespan axially oriented crack like indication. Two (2) tubes were plugged for circumferentially oriented crack like indications at the top of tubesheet expansion. No other tubes were degraded.

9

Steam Generator B had no tubes with degradation detected by RPC in the Row 1 and 2 u-bends, or the expanded preheater baffle plate program. There were no tubes removed from service due to volumetric freespan indications or permeability variations.

One hundred seventy-one (171) tubes were preventatively plugged. One hundred forty-nine (149) tubes were repaired for bobbin DSI signals that do not exceed the ARC voltage requirement. Four (4) were suspected leaking tubes. Eighteen (18) tubes because of support plate locking.

5.3 Steam Generator C A total of forty-eight (48) tubes were considered defective as defined by the Technical Specification 4.4.5.4.

Thirty-two (32) tubes were plugged for confirmed bobbin DSI indications at support plate elevations. Eleven (11) tubes were removed from service for a freespan axially oriented crack like indication. Two (2) tubes were plugged for circumferentially oriented crack like indications at the top of tubesheet expansion. Two (2) tubes were plugged for volumetric indications reported in freespan tubing. One (1) tube was removed from service for a volumetric indication that coincided with an expanded preheater baffle plate. No other tubes were degraded.

Steam Generator C had no tubes with degradation detected by RPC in the Row I and 2 u-bends.

One hundred eighty-two (182) tubes were preventatively plugged. One hundred forty-nine (149) tubes were repaired for bobbin DSI signals that do not exceed the ARC voltage requirement. Eleven (11) were suspected leaking tubes. Eighteen (18) tubes because of support plate locking. Four (4) tubes were plugged for permeability variation responses that spanned the top of tubesheet expansion.

5.4 Steam Generator D A total of thirty-eight (38) tubes were considered defective as defined by the Technical Specification 4.4.5.4.

Thirty-one (31) tubes were plugged for confirmed bobbin DSI indications at support plate elevations. Four (4) tubes were removed from service for a freespan axially oriented crack like indication. Two (2) tubes were plugged for circumferentially oriented crack like indications at the top of tubesheet expansion. One (1) tube required repair due to an axial indication in a Row 1 u-bend. One (1) additional degraded tube was reported that was not defective.

Row 35 Column 74 had a 25% indication reported at AVB #3.

Steam Generator D had no tubes with degradation detected in the expanded preheater baffle plate program. There were no tubes removed from service due to volumetric freespan indications or permeability variations.

One hundred eighty-six (186) tubes were preventatively plugged. One hundred sixty-three (163) tubes were repaired for bobbin DSI signals that do not exceed the ARC voltage requirement. Five (5) were suspected leaking tubes. Eighteen (18) tubes because of support plate locking.

The minimum required size of the initial ISI sample is defined in Technical Specification 3/4.4.5 Table 4.4-2. It requires that the minimum initial sample for inspecting four (4) steam generators be three (3) percent of the total tubes installed in each generator. In addition, Technical Specification 3/4.4.5.2.e requires the following: "For Unit 2, implementation of the steam generator tube/tube support plate repair criteria requires a 100 percent bobbin coil inspection for hot leg and cold leg tube support plates with known outside diameter stress corrosion cracking (ODSCC) indications." The "2001 Outage Plan for the In-service Inspection of Steam Generator Tubing at the South Texas Project Electric Generating Station Unit 2", discussed in Section 2.0 above, was implemented and the initial sample requirements of Technical Specification 3/4.4.5 Table 4.4-2 and paragraph 4.4.5.2.e were met as shown in the following Tables.

10

The numbers of tubes examined in the bobbin coil inspection sample and the number of tubes, which contain degradation, and/or defects confirmed by RPC, along with the appropriate Result Categories are summarized as follows:

Steam Generator ET Sample Tubes Examined Degraded Tubes Defective Tubes Category A

1st 4655 23 23 C-2 B

1st 4632 20 620 C-2 C

1st 4615 32 32 C-2 D

1 st 4633 31 31 C-2 The results of the pre-planned Plus point RPC ET at specified locations were as follows:

Steam Generator Total Inspected RPC Locations Degraded Tubes Defective Tubes Category TSH/DNG's/LRUB/CL Baffles A

1555 82 143 /64 12 12 C-2 B

1554/80/143/64 3

3 C-2 C

1541 /87 /143 /64 16 16 C-2 D

1549 /126 /142 /64 7

7 C-2 Totals 6199 / 1375 /571/256 38 38 It is noted that the above quantities of locations in the RPC program do not include any newly reported dings found during 2RE08.

Category C-3 is defined in the Technical Specification as follows:

"More than 10% of the total tubes inspected are degraded tubes or more than 1% of the inspected tubes are defective."

One of the four steam generators, Steam Generator C, reached the C-3 category from combining the bobbin coil and RPC ET inspection program. The forty-eight (48) defective tubes that contributed to the C-3 category were a result of the following causes: thirty-two (32) tubes for confirmed DSI's at TSP's; eleven (11) tubes reported freespan axially oriented crack like indications; two (2) tubes had circumferentially oriented crack like indications at the top of tubesheet expansion; two (2) tubes were plugged for volumetric indications reported in freespan tubing; and one (1) tube was removed from service for a volumetric indication that coincided with an expanded preheater baffle plate Category C-2 is defined in the Technical Specification as follows:

"One or more, but not more than 1% of the total tubes inspected are defective, or between 5% and 10% of the total tubes inspected are degraded tubes."

Results for the 100 percent tube inspection by bobbin coil in all four (4) steam generators are categorized as Category C-2. Because full-length bobbin coil ET inspections were performed on all TSP intersections in each in service tube, no other inspections in the areas of concern could be performed.

As described earlier, the hot leg top of tubesheet exam, and the expanded preheater baffle plate inspection were expanded in all steam generators due to findings reported during 2RE08. In Steam Generator D the ding pair examination was increased to 100% located in each leg. Plus, STP elected to examine 20% of the cold leg "ding pairs" outside the initial defined scope in each of the remaining three steam generators. Finally, a Row I u-bend indication in Steam Generator D led to expanding the Row 2 sample for that steam generator to 100%. Therefore, the Technical Specification requirements for additional examinations required in response to examination results were met.

11

The tubes that were removed from service by plugging prior to this ISI and as a result of this ISI are identified on tubesheet maps, one for each steam generator, in Appendix E. The symbol X on each map represents those tubes plugged during this outage and "box symbol" ("Existing Plugs") are those locations removed from service prior to 2RE08.

12

6.0 Certification of Inspections A Section XI NIS-1 form, "Owner's Report for Inservice Inspections," has been prepared to certify the STPEGS Unit 2 ISI examinations described in this Summary Report. The STPEGS Unit 2 ISI examinations have been certified by our ANII, Arkwright Mutual Insurance Company, on the NIS-1 form included in Appendix F.

13

APPENDIX A LIST OF EXAMINATION AND DATA ANALYSIS PERSONNEL

Appendix A Listing of Certified Personnel ACQUISITION PERSONNEL BRADLEY, D.

II W

B8909 ALTMAN, T.R.

I W

A8552 CHIPLASKEY, G.

II W

C2990 CRIMBLY, M.

II W

C9087 BOLT, W.

I W

B5452 DVORAK, D.

I W

D5833 ESTEL, J.

II W

E2361 GALLIK, M.

I W

G0202 GAULT, W.

II W

G4119 GROH, T.

II W

G5933 HAZLETT, W.

II W

H3548 HILL, W.

I W

H3260 JURY, J.

I W

J4353 KOESER, S.

II W

K9235 MAINS, P.

II W

M8834 MARDELL, D.

II W

M6037 MARVIN, T.

I W

M3909 PARRIS, T.

II W

P2305 PATTON,B.

I W

P7959 RESTINA, D.

II W

R6706 SMITH, A.

II W

S1703 SPEARS, T.

IT W

S6464 STITT, A.

II W

S8766 STOOTS, B.

I W

S0504 TEDRICK, J.

I W

T9100 THOMPSON, K.

II W

T8375 TUCKER, R.

II W

T8828 WHALEN, D.

I W

W3558 Data Cops PIERINI, G.

III W

P6121 MOATES, R.C.

IIA W

M7073

Listing of Certified Personnel A-1 SITE RESOLUTION PERSONNEL Appendix A NAME RASCHIATORE, J.

LOHNER, E.

SPENCE, W.

WHEELER, C.K.

BOWSER, G.C.

CHAMBERS, D.M.

LANDIS, M.

NEYMAN, R.

NELSON, D.L.

POCRATSKY, R.

STOKKE, T.F.

LOOPER, V.R MATHESON, M.J.

REHAK, R.

PADGETT, T.

(DAYS)

(DAYS)

(DAYS)

(DAYS)

(DAYS)

(DAYS)

(DAYS)

(DAYS)

(NITE)

(NITE)

(NITE)

(NITE)

(NITE)

(NITE)

(NITE)

Data Management/Sys Admin MARLIS, C.J.

JACKSON, S.

FLYNN, L.A.

MOSLENER, M.

CALLENDER, R.

ZEVCHAK, J.

HOVER, A.

LOW, R.

LEVIN, J.

GEORGE, W.

YEE, N.

Level III III III III III III IIA III

'III III III III III III III USER ID R7018 L1342 S1253 W1424 B9540 C5542 L0601 N0942 N7035 P4536 S0558 L5914 M0554 R5555 P4578 Company W

NDE W

NDE CSI MT FTI FTI NDE W

NDE NDE FTI DESI DESI W

MT NDE NDE NDE CSI V&J FTI FTI FTI FTI ASSIGNMENT LEAD RESO RESO RESO RESO RESO RESO RESO RESO RESO RESO RESO RESO RESO RESO LEAD DAY DAY NITE LEAD NITE NITE DAY DAY NITE DAY NITE DM DM DM DM DM DM DM DM DM SYSAD SYSAD

Appendix A Listing of Certified Personnel A-2 PRIMARY ANALYSTS - Westinghouse AKERLIND, B.E.

NDE III A6567 ANDERSON, D.A.

NDE IIA A3502 BEIERS, T.

NDE III B2535 BROWN, M.

NDE III B2687 INGRAHAM, R.

NDE III 12164 JERINA, F.

NDE III J1771 HAYNES, W.R NDE III H6377 MAST, M.S NDE III M8713 JOHNSON, J.

NDE IIA J8109 LEWIS, D.

NDE III L3237 RUSCITTI, S.F NDE IIA R2495 LEWIS, C.

NDE IIA L3362 OBAZENU, D.

ANA III 01625 THOMPSON, V.A.

NDE III T0658 POPOVICH, R.

W III P6444 RICHMOND, M.

NDE III R3716 SIEGEL, R.

NDE III S5760 STOCK, W.

W III S3314 TOBIN, R.

W III T8398 YAKLICH, D.

W III Y1950 WRUBLESKI, A.J.

QTM III W1758 CDS ANALYSIS CASE, J.M NDE III C9055 ETHERIDGE, G.

NDE III E2505 HICKS, O.L.

NDE IIA H6561 SHELDEN, J.T.

NDE III S8046 ARC GROWTH STOCK, C.A W

IIA S5187 WADZINSKI, D.J.

ANA III W2545 KO, J.I.

KPS IIA K8602 OH, C.H.

KPS IIA 08912 WILLIAMSON, J.

ANA IIA W4786

Appendix A Listing of Certified Personnel A-3 SECONDARY ANALYSTS - Framatome Technology NAME Company Level USER ID BLANKENSHIP, B.

FTI IIA B6768 BOWEN, E.

FTI IIA B4052 CALLISON, P.

DESI IIA C6308 DEFILLIPPIS, N.J FTI IIA D9424 CONNER, C. J.

FTI IIA C1250 DIAZ, J.

FTI IIA D1279 ERICSON, E.

DESI III E4963 HERRARA, G.

FTI IIA H3464 JONES, M.

FTI IIA J9815 KENNEDY, C.

FTI IIA K9438 KORKOWSKI, E.

FTI III K7060 LAREAU, K.

FTI III L2157 NEWMAN, E.

FTI IIA N9952 VORNHAGEN, J.W FTI IIA V6131 OLIVER, J FTI IIA 01057 WRIGHT, K.C.

FTI IIA W4897 PARKER, D.

DESI IIA P5581 PARRISH, J.

FTI IIA P5436 SHUTLER, T.

DESI III S4256 SMATHERS, D.

DESI IIA S2720 TOBIN, W.

FTI IIA T5565 TORRES, D.

FTI IIA T6956 WASHBURN, T.

FTI IIA W4892 WHATLEY, C.

DESI IIA W9213 A-4

APPENDIX B Tubes Examined by MRPC at Locations Other Than TSH

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 1

1 10H 11C

.580 ZPUMB 1

1 11C 10H

.580 ZPUMB 2

1 10H 11C

.580 ZPUMB 1

2 10H 11C

.580 ZPUMB 1

2 11C 11C

.610 ZPSNM 2

2 10H 11C

.580 ZPUMB 2

2 11C 10H

.580 ZPUMB 1

3 10H 11C

.580 ZPUMB 1

4 10H 11C

.580 ZPUMB 1

5 10H 11C

.580 ZPUMB 20 5

AV2 AV1

.580 ZPUNM 1

6 10H 11C

.580 ZPUMB 2

6 10H 11C

.580 ZPUMB 8

6 13C 12C

.610 ZPSNM 8

6 220 21C

.610 ZPSMB 1

7 10H 11C

.580 ZPUMB 14 7

01H 02H

.610 ZPSNM 1

8 10H 11C

.580 ZPUMB 18 8

10H 10H

.610 ZPSNM 26 8

10H 10H

.610 ZPSNM 1

9 10H 11C

.580 ZPUMB 1

10 10H 11C

.580 ZPUMB 9

10 08H 09H

.610 ZPSNM 13 10 02H 02H

.610 ZPSNM 30 10 02H 02H

.610 ZPSNM 1

11 10H 11C

.580 ZPUMB 1

12 10H 11C

.580 ZPUMB 2

12 10H 11C

.580 ZPUMB 30 12 15C 14C

.610 ZPSNM 30 12 16C 15C

.610 ZPSMB 1

13 10H 11C

.580 ZPUMB 1

14 10H 11C

.580 ZPUMB 2

14 10H 11C

.580 ZPUMB 4

14 10H 10H

.580 ZPUEU 4

14 10H 10H

.580 ZPUNM 10 14 02H 02H

.610 ZPSNM 1

15 10H 11C

.580 ZPUMB 2

15 10H 11C

.580 ZPUMB 20 15 02H 02H

.610 ZPSNM 28 15 04H 05H

.610 ZPSNM 28 15 08H 09H

.610 ZPSNM 1

16 10H 11C

.580 ZPUFU 1

16 10H 11C

.580 ZPUMB 1

16 110 10H

.580 ZPUMB 9

16 02H 02H

.610 ZPSNM B-1 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 10 16 02H 02H

.610 ZPSNM 16 16 03H 03H

.610 ZPSNM 39 16 TSC TSC

.610 ZPSNM 1

17 10H I1C

.580 ZPUMB 1

17 1IC 10H

.580 ZPUMB 2

17 10H 1IC

.580 ZPUMB 2

17 11C 10H

.580 ZPUMB 13 17 02H 02H

.610 ZPSNM 15 17 02H 02H

.610 ZPSNM 26 17 02H 02H

.610 ZPSNM 1

18 10H lIC

.580 ZPUMB 9

18 09H 10H

.610 ZPSNM 1

19 10H 11C

.580 ZPUMB 14 19 03H 03H

.610 ZPSNM 1

20 10H 11C

.580 ZPUMB 23 20 02H 02H

.610 ZPSNM 1

21 10H lhC

.580 ZPUMB 14 21 02H 02H

.610 ZPSNM 17 21 02H 02H

.610 ZPSNM 22 21 02H 02H

.610 ZPSNM 43 21 21C 21C

.610 ZPSNM 43 21 22C 22C

.610 ZPSNM 1

22 10H 1hC

.580 ZPUMB 15 22 02H 02H

.610 ZPSNM 28 22 02H 02H

.610 ZPSNM 31 22 01H 02H

.610 ZPSNM 1

23 10H GlC

.580 ZPUMB 13 23 08H 09H

.610 ZPSNM 17 23 05H 06H

.610 ZPSNM 20 23 02H 02H

.610 ZPSNM 44 23 21C 21C

.610 ZPSNM 44 23 22C 22C

.610 ZPSNM 1

24 10H 11C

.580 ZPUMB 14 24 03H 03H

.610 ZPSNM 18 24 01H 02H

.610 ZPSNM 23 24 02H 02H

.610 ZPSNM 42 24 16C 15C

.610 ZPSNM 43 24 10H 10H

.610 ZPSNM 1

25 10H 11C

.580 ZPUMB 2

25 10H lIC

.580 ZPUMB 9

25 AVl AVI

.580 ZPUNM 22 25 02H 02H

.610 ZPSNM 23 25 02H 02H

.610 ZPSNM 23 25 03H 03H

.610 ZPSNM 33 25 12C lhC

.610 ZPSNM B-2 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 1

26 10H 11C

.580 ZPUMB 4

26 10H 10H

.580 ZPUEU 4

26 10H 10H

.580 ZPUNM 16 26 11C AV4

.580 ZPUFU 1

27 10H 11C

.580 ZPUMB 2

27 10H 11C

.580 ZPUMB 9

27 AV1 AVI

.580 ZPUNM 13 27 02H 02H

.610 ZPSNM 14 27 03H 03H

.610 ZPSNM 18 27 10H 10H

.610 ZPSNM 19 27 02H 02H

.610 ZPSNM 19 27 04H 04H

.610 ZPSNM 21 27 03H 03H

.610 ZPSNM 30 27 10H 10H

.610 ZPSNM 36 27 01H 02H

.610 ZPSNM 1

28 10H 11C

.580 ZPUMB 9

28 AV2 AVi

.580 ZPUNM 19 28 03H 03H

.610 ZPSNM 26 28 02H 02H

.610 ZPSNM 29 28 02H 02H

.610 ZPSNM 29 28 19C 19C

.610 ZPSNM 40 28 TSH 01H

.610 ZPSNM 48 28 21C 21C

.610 ZPSNM 48 28 22C 22C

.610 ZPSNM 1

29 10H 11C

.580 ZPUMB 9

29 AV2 AVI

.580 ZPUNM 19 29 02H 02H

.610 ZPSNM 20 29 03H 03H

.610 ZPSNM 24 29 04H 04H

.610 ZPSNM 48 29 21C 21C

.610 ZPSNM 48 29 22C 22C

.610 ZPSNM 1

30 10H 11C

.580 ZPUMB 15 30 02H 02H

.610 ZPSNM 15 30 03H 03H

.610 ZPSNM 22 30 02H 02H

.610 ZPSNM 1

31 10H 11C

.580 ZPUMB 8

31 09H 09H

.580 ZPUMB 8

31 10H 10H

.580 ZPUEU 21 31 07H 07H

.610 ZPSNM 1

32 10H 11C

.580 ZPUMB 11 32 02H 02H

.610 ZPSNM 13 32 02H 02H

.610 ZPSNM 21 32 02H 02H

.610 ZPSNM 1

33 10H 11C

.580 ZPUMB 22 33 04H 04H

.610 ZPSNM B-3 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 27 33 03H 03H

.610 ZPSNM 39 33 19C 18C

.610 ZPSNM 1

34 10H 11C

.580 ZPUMB 2

34 10H 11C

.580 ZPUMB 16 34 06H 07H

.610 ZPSNM 18 34 02H 02H

.610 ZPSNM 19 34 02H 02H

.610 ZPSNM 20 34 02H 02H

.610 ZPSNM 1

35 10H 11C

.580 ZPUMB 2

35 10H 11C

.580 ZPUMB 17 35 05H 05H

.610 ZPSNM 18 35 02H 02H

.610 ZPSNM 21 35 03H 03H

.610 ZPSNM 35 35 16C 15C

.610 ZPSNM 48 35 07H 08H

.580 ZPSNM 1

36 10H 11C

.580 ZPUMB 17 36 17C 16C

.610 ZPSMB 1

37 10H 11C

.580 ZPUMB 1

37 11C 10H

.580 ZPUMB 1

38 10H 11C

.580 ZPUMB 1

38 11C 10H

.580 ZPUMB 20 38 02H 02H

.610 ZPSNM 23 38 02H 02H

.610 ZPSNM 23 38 03H 03H

.610 ZPSNM 1

39 10H 11C

.580 ZPUMB 1

39 11C 10H

.580 ZPUMB 21 39 02H 02H

.610 ZPSNM 1

40 11C 10H

.580 ZPUMB 31 40 19C 19C

.610 ZPSNM 1

41 11C 10H

.580 ZPUMB 3

41 11C 10H

.580 ZPUNM 4

41 11C 10H

.580 ZPUNM 24 41 02H 02H

.610 ZPSNM 33 41 03H 03H

.610 ZPSNM 1

42 11C 10H

.580 ZPUMB 8

42 10H 10H

.610 ZPSNM 8

42 11C 11C

.610 ZPSNM 16 42 TEH TEH

.610 ZPSNM 26 42 02H 02H

.610 ZPSNM 1

43 11C 10H

.580 ZPUMB 23 43 03H 03H

.610 ZPSNM 23 43 04H 04H

.610 ZPSNM 47 43 21C 21C

.610 ZPSNM 47 43 22C 22C

.610 ZPSNM 1

44 110 10H

.580 ZPUMB B-4 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 22 44 04H 04H

.610 ZPSNM 24 44 03H 03H

.610 ZPSNM 25 44 02H 02H

.610 ZPSNM 44 44 TSH 01H

.610 ZPSNM 47 44 21C 21C

.610 ZPSNM 47 44 22C 22C

.610 ZPSNM 1

45 11C 10H

.580 ZPUMB 2

45 11C 10H

.580 ZPUMB 4

45 22C 22C

.610 ZPSNM 18 45 02H 02H

.610 ZPSNM 35 45 04H 04H

.610 ZPSNM 48 45 21C 21C

.610 ZPSNM 48 45 22C 22C

.610 ZPSNM 1

46 10H 11C

.580 ZPUMB 1

46 11C 10H

.580 ZPUMB 24 46 05H 05H

.610 ZPSNM 47 46 21C 21C

.610 ZPSNM 47 46 22C 22C

.610 ZPSNM 1

47 11C 10H

.580 ZPUMB 22 47 10H 10H

.580 ZPUMB 1

48 11C 10H

.580 ZPUMB 21 48 17C 16C

.610 ZPSNM 21 48 19C 18C

.610 ZPSNM 1

49 11C 10H

.580 ZPUMB 48 49 21C 21C

.610 ZPSNM 48 49 22C 22C

.610 ZPSNM 1

50 10H 11C

.580 ZPUMB 1

50 11C 10H

.580 ZPUMB 14 50 02H 02H

.610 ZPSNM 25 50 02H 02H

.610 ZPSNM 1

51 11C 10H

.580 ZPUMB 18 51 02H 02H

.610 ZPSNM 26 51 03H 03H

.610 ZPSNM 43 51 02H 02H

.610 ZPSNM 48 51 21C 21C

.610 ZPSNM 48 51 22C 22C

.610 ZPSNM 1

52 11C 10H

.580 ZPUMB 36 52 11C 11C

.580 ZPUFU 47 52 21C 21C

.610 ZPSNM 47 52 22C 22C

.610 ZPSNM 1

53 11C 10H

.580 ZPUMB 1

54 10H 11C

.580 ZPUMB 1

54 11C 10H

.580 ZPUMB 15 54 10H 10H

.580 ZPUNM 15 54 10H AV2

.580 ZPUNM B-5 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 19 54 02H 02H

.610 ZPSNM 19 54 03H 03H

.610 ZPSNM 32 54 02H 02H

.610 ZPSNM 46 54 21C 21 C

.610 ZPSNM 46 54 22C 22C

.610 ZPSNM 48 54 21C 21C

.610 ZPSNM 48 54 22C 22C

.610 ZPSNM 1

55 10H 11C

.580 ZPUMB 27 55 04H 04H

.610 ZPSNM 47 55 21C 21C

.610 ZPSNM 47 55 22C 22C

.610 ZPSNM 1

56 10H 11C

.580 ZPUMB 2

56 10H 11C

.580 ZPUMB 23 56 02H 02H

.610 ZPSNM 24 56 11C AV3

.580 ZPUFU 33 56 03H 03H

.610 ZPSNM 1

57 10H 11C

.580 ZPUMB 11 57 10H 10H

.580 ZPUMB 47 57 21C 21C

.610 ZPSNM 47 57 22C 22C

.610 ZPSNM 48 57 11C 11C

.580 ZPUFU 1

58 10H 11C

.580 ZPUMB 24 58 15C 14C

.610 ZPSMB 45 58 21C 21C

.610 ZPSNM 45 58 22C 22C

.610 ZPSNM 1

59 10H 11C

.580 ZPUMB 26 59 02H 02H

.610 ZPSNM 26 59 03H 03H

.610 ZPSNM 44 59 21C 21C

.610 ZPSNM 44 59 22C 22C

.610 ZPSNM 45 59 21C 21C

.610 ZPSNM 45 59 22C 22C

.610 ZPSNM 46 59 21C 21C

.610 ZPSNM 46 59 22C 22C

.610 ZPSNM 1

60 10H 11C

.580 ZPUMB 1

61 11C 10H

.580 ZPUMB 2

61 11C 10H

.580 ZPUMB 1

62 11C 10H

.580 ZPUMB 10 62 01H 02H

.610 ZPSNM 20 62 09H 09H

.610 ZPSNM 20 62 10H 10H

.610 ZPSNM 24 62 02H 02H

.610 ZPSNM 39 62 21C 21C

.610 ZPSNM 39 62 22C 22C

.610 ZPSNM 43 62 21C 21C

.610 ZPSNM B-6 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 43 62 22C 22C

.610 ZPSNM 45 62 21C 21C

.610 ZPSNM 45 62 22C 22C

.610 ZPSNM 48 62 21C 21C

.610 ZPSNM 48 62 22C 22C

.610 ZPSNM 1

63 11C 10H

.580 ZPUMB 45 63 04H 05H

.580 ZPSNM 1

64 11C 10H

.580 ZPUMB 1

65 11C 10H

.580 ZPUMB 7

65 11C 11C

.610 ZPSNM 26 65 03H 03H

.610 ZPSNM 26 65 09H 10H

.610 ZPSNM 26 65 12C 13C

.610 ZPSNM 28 65 02H 02H

.610 ZPSNM 28 65 03H 03H

.610 ZPSNM 36 65 04H 04H

.610 ZPSNM 48 65 21C 21C

.610 ZPSNM 48 65 22C 22C

.610 ZPSNM 1

66 11C 10H

.580 ZPUMB 2

66 11C 10H

.580 ZPUMB 2

66 12C 11C

.610 ZPSNM 25 66 02H 02H

.610 ZPSNM 26 66 02H 02H

.610 ZPSNM 26 66 03H 03H

.610 ZPSNM 28 66 03H 03H

.610 ZPSNM 48 66 21C 21C

.610 ZPSNM 48 66 22C 22C

.610 ZPSNM 1

67 11C 10H

.580 ZPUMB 23 67 02H 02H

.610 ZPSNM 25 67 03H 03H

.610 ZPSNM 28 67 03H 03H

.610 ZPSNM 46 67 21C 21C

.610 ZPSNM 46 67 22C 22C

.610 ZPSNM 47 67 21C 21C

.610 ZPSNM 47 67 22C 22C

.610 ZPSNM 1

68 11C 10H

.580 ZPUMB 20 68 02H 02H

.610 ZPSNM 31 68 02H 02H

.610 ZPSNM 1

69 11C 10H

.580 ZPUMB 35 69 12C 11C

.610 ZPSNM 45 69 05H 06H

.610 ZPSNM 46 69 21C 21C

.610 ZPSNM 46 69 22C 22C

.610 ZPSNM 1

70 10H 11C

.580 ZPUMB fU 11{

1 OH.58 0 ZPUMB B-7 Appendix B I

10H

.58

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 19 70 02H 02H

.610 ZPSNM 24 70 03H 03H

.610 ZPSNM 28 70 03H 03H

.610 ZPSNM 40 70 01H 02H

.610 ZPSNM 46 70 21C 21C

.610 ZPSNM 46 70 22C 22C

.610 ZPSNM 1

71 11C 10H

.580 ZPUMB 6

71 01H 02H

.610 ZPSNM 24 71 03H 03H

.610 ZPSNM 26 71 02H 02H

.610 ZPSNM 33 71 03H 03H

.610 ZPSNM 37 71 03H 03H

.610 ZPSNM 42 71 02H 02H

.610 ZPSNM 2

72 lIC 10H

.580 ZPUMB 24 72 02H 02H

.610 ZPSNM 31 72 03H 03H

.610 ZPSNM 42 72 10H 10H

.610 ZPSNM 44 72 03H 03H

.610 ZPSNM 46 72 10H 10H

.610 ZPSNM 47 72 21C 21C

.610 ZPSNM 47 72 22C 22C

.610 ZPSNM 1

73 lIC 10H

.580 ZPUMB 3

73 06H 07H

.610 ZPSNM 22 73 02H 02H

.610 ZPSNM 24 73 04H 04H

.610 ZPSNM 48 73 17C 16C

.610 ZPSMB 1

74 lIC 10H

.580 ZPUMB 32 74 02H 02H

.610 ZPSNM 32 74 03H 03H

.610 ZPSNM 32 74 04H 04H

.610 ZPSNM 33 74 02H 02H

.610 ZPSNM 1

75 lIC 10H

.580 ZPUMB 21 75 03H 03H

.610 ZPSNM 21 75 04H 04H

.610 ZPSNM 22 75 03H 03H

.610 ZPSNM 31 75 03H 03H

.610 ZPSNM 34 75 05H 06H

.610 ZPSNM 48 75 TSH 01H

.610 ZPSNM 1

76 11C 10H

.580 ZPUMB 2

76 11C 10H

.580 ZPUMB 24 76 03H 03H

.610 ZPSNM 26 76 03H 03H

.610 ZPSNM 26 76 04H 04H

.610 ZPSNM 27 76 04H 04H

.610 ZPSNM 1

77 liC 10H

.580 ZPUMB B-8 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 23 77 03H 03H

.610 ZPSNM 25 77 02H 02H

.610 ZPSNM 25 77 03H 03H

.610 ZPSNM 25 77 17C 16C

.610 ZPSMB 28 77 02H 02H

.610 ZPSNM 28 77 03H 03H

.610 ZPSNM 39 77 08H 08H

.610 ZPSNM 39 77 09H 10H

.610 ZPSNM 46 77 11C 11C

.610 ZPSNM 1

78 11C 10H

.580 ZPUMB 22 78 02H 02H

.610 ZPSNM 26 78 03H 03H

.610 ZPSNM 35 78 03H 03H

.610 ZPSNM 1

79 11C 10H

.580 ZPUMB 16 79 01H 02H

.610 ZPSNM 23 79 03H 03H

.610 ZPSNM 25 79 03H 03H

.610 ZPSNM 32 79 03H 03H

.610 ZPSNM 33 79 13C 12C

.610 ZPSNM 1

80 11C 10H

.580 ZPUMB 20 80 02H 02H

.610 ZPSNM 23 80 03H 03H

.610 ZPSNM 24 80 02H 02H

.610 ZPSNM 42 80 21C 21C

.610 ZPSNM 48 80 21C 21C

.610 ZPSNM 48 80 22C 22C

.610 ZPSNM 1

81 11C 10H

.580 ZPUMB 2

81 11C 10H

.580 ZPUMB 20 81 03H 03H

.610 ZPSNM 22 81 03H 03H

.610 ZPSNM 33 81 03H 03H

.610 ZPSNM 38 81 16C 15C

.610 ZPSMB 44 81 01H 02H

.610 ZPSNM 1

82 11C 101H

.580 ZPUMB 6

82 01H 02H

.610 ZPSNM 19 82 17C 16C

.610 ZPSMB 24 82 03H 03H

.610 ZPSNM 26 82 03H 03H

.610 ZPSNM 33 82 03H 03H

.610 ZPSNM 1

83 11C 10H

.580 ZPUMB 11 83 21C 20C

.610 ZPSMB 26 83 03H 03H

.610 ZPSNM 31 83 04H 04H

.610 ZPSNM 34 83 03H 03H

.610 ZPSNM 1

84 110 10H

.580 ZPUMB B-9 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 19 84 02H 02H

.610 ZPSNM 21 84 04H 04H

.610 ZPSNM 25 84 02H 02H

.610 ZPSNM 30 84 03H 03H

.610 ZPSNM 1

85 11C 10H

.580 ZPUMB 9

85 04H 05H

.610 ZPSNM 20 85 02H 02H

.610 ZPSNM 20 85 03H 03H

.610 ZPSNM 22 85 03H 03H

.610 ZPSNM 23 85 10H 10H

.610 ZPSNM 34 85 02H 02H

.610 ZPSNM 1

86 11C 10H

.580 ZPUMB 5

86 16C 15C

.610 ZPSNM 17 86 02H 02H

.610 ZPSNM 20 86 05H 05H

.610 ZPSNM 22 86 02H 02H

.610 ZPSNM 23 86 02H 02H

.610 ZPSNM 46 86 17C 16C

.610 ZPSMB 47 86 21C 21C

.610 ZPSNM 1

87 11C 10H

.580 ZPUMB 2

87 11C 10H

.580 ZPUMB 14 87 02H 02H

.610 ZPSNM 16 87 02H 02H

.610 ZPSNM 19 87 02H 02H

.610 ZPSNM 20 87 16C 15C

.610 ZPSNM 22 87 13C 12C

.610 ZPSNM 25 87 02H 02H

.610 ZPSNM 1

88 11C 10H

.580 ZPUMB 11 88 10H 10H

.610 ZPSNM 11 88 11C 11C

.610 ZPSNM 21 88 02H 02H

.610 ZPSNM 29 88 03H 03H

.610 ZPSNM 1

89 11C 10H

.580 ZPUMB 16 89 02H 02H

.610 ZPSNM 18 89 02H 02H

.610 ZPSNM 33 89 04H 04H

.610 ZPSNM 34 89 01H 02H

.610 ZPSNM 37 89 04H 04H

.610 ZPSNM 1

90 lIC 10H

.580 ZPUMB 4

90 11C 10H

.580 ZPUNM 18 90 02H 02H

.610 ZPSNM 18 90 03H 03H

.610 ZPSNM 31 90 03H 03H

.610 ZPSNM 1

91 11C 10H

.580 ZPUMB 13 91 02H 02H

.610 ZPSNM B-10 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 14 91 02H 02H

.610 ZPSNM 16 91 02H 02H

.610 ZPSNM 19 91 03H 03H

.610 ZPSNM 23 91 02H 02H

.610 ZPSNM 23 91 03H 03H

.610 ZPSNM 29 91 01H 01H

.610 ZPSNM 29 91 01H 02H

.610 ZPSNM 29 91 04H 04H

.610 ZPSNM 1

92 10H 11C

.580 ZPUMB 1

92 11C 10H

.580 ZPUMB 2

92 10H C

lC

.580 ZPUMB 2

92 11C 10H

.580 ZPUMB 11 92 02H 02H

.610 ZPSNM 18 92 02H 02H

.610 ZPSNM 20 92 02H 02H

.610 ZPSNM 1

93 10H 11C

.580 ZPUMB 1

93 11C 10H

.580 ZPUMB 2

93 10H lIC

.580 ZPUMB 2

93 1iC 10H

.580 ZPUMB 13 93 02H 02H

.610 ZPSNM 14 93 02H 02H

.610 ZPSNM 16 93 02H 02H

.610 ZPSNM 25 93 03H 03H

.610 ZPSNM 31 93 13C 12C

.610 ZPSMB 1

94 10H 11C

.580 ZPUMB 20 94 01H 02H

.610 ZPSNM 25 94 03H 03H

.610 ZPSNM 25 94 04H 04H

.610 ZPSNM 1

95 10H lIC

.580 ZPUMB 16 95 03H 03H

.610 ZPSNM 18 95 02H 02H

.610 ZPSNM 24 95 16C 15C

.610 ZPSMB 37 95 06H 06H

.610 ZPSNM 1

96 10H 11C

.580 ZPUMB 17 96 03H 03H

.610 ZPSNM 23 96 02H 02H

.610 ZPSNM 23 96 03H 03H

.610 ZPSNM 1

97 10H 11C

.580 ZPUMB 8

97 02H 02H

.610 ZPSNM 8

97 11C 11C

.610 ZPSNM 8

97 11C AV4

.580 ZPUFU 18 97 02H 02H

.610 ZPSNM 18 97 03H 03H

.610 ZPSNM 22 97 02H 02H

.610 ZPSNM 23 97 02H 02H

.610 ZPSNM B-I I Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-A ROW COLUMN BEGIN TEST END TEST PROBE 25 97 02H 02H

.610 ZPSNM 39 97 04H 05H

.580 ZPSNM 1

98 11C 10H

.580 ZPUMB 17 98 02H 02H

.610 ZPSNM 24 98 14C 13C

.610 ZPSNM 1

99 11C 10H

.580 ZPUMB 6

99 10H 10H

.580 ZPUMB 9

99 02H 02H

.610 ZPSNM 10 99 02H 02H

.610 ZPSNM 15 99 03H 03H

.610 ZPSNM 16 99 04H 04H

.610 ZPSNM 18 99 02H 02H

.610 ZPSNM 18 99 03H 03H

.610 ZPSNM 40 99 15C 14C

.610 ZPSMB 44 99 21C 21C

.610 ZPSNM 44 99 22C 22C

.610 ZPSNM 1

100 11C 10H

.580 ZPUMB 21 100 02H 02H

.610 ZPSNM 1

101 11C 10H

.580 ZPUMB 17 101 02H 02H

.610 ZPSNM 18 101 02H 02H

.610 ZPSNM 18 101 03H 03H

.610 ZPSNM 23 101 03H 03H

.610 ZPSNM 1

102 11C 10H

.580 ZPUMB 16 102 03H 03H

.610 ZPSNM 18 102 02H 02H

.610 ZPSNM 20 102 03H 03H

.610 ZPSNM 23 102 02H 02H

.610 ZPSNM 25 102 02H 02H

.610 ZPSNM 1

103 11C 10H

.580 ZPUMB 14 103 02H 02H

.610 ZPSNM 18 103 03H 03H

.610 ZPSNM 22 103 02H 02H

.610 ZPSNM 23 103 02H 02H

.610 ZPSNM 24 103 02H 02H

.610 ZPSNM 24 103 03H 03H

.610 ZPSNM 27 103 03H 03H

.610 ZPSNM 1

104 11C 10H

.580 ZPUMB 18 104 02H 02H

.610 ZPSNM 36 104 15C 14C

.610 ZPSNM 1

105 11C 10H

.580 ZPUMB 16 105 03H 03H

.610 ZPSNM 22 105 02H 02H

.610 ZPSNM 1

106 11C 10H

.580 ZPUMB 13 1u6 02H 02H L ____________

.610 ZPSNM B-12 Appendix B 02H

Tubes Examined By RPC at Locations Other than TSH S/G-A B-13 Appendix B ROW COLUMN BEGIN TEST END TEST PROBE 25 106 10H 10H

.580 ZPUNM 28 106 06H 07H

.610 ZPSNM 31 106 13C 12C

.610 ZPSMB 1

107 11C 10H

.580 ZPUMB 2

107 11C 10H

.580 ZPUMB 19 107 02H 02H

.610 ZPSNM 1

108 1iC 10H

.580 ZPUMB 1

109 11C 10H

.580 ZPUMB 1

110 11C 10H

.580 ZPUMB 2

110 11C 10H

.580 ZPUMB 20 110 12C 11C

.610 ZPSMB 1

111 11C 10H

.580 ZPUMB 1

112 11C 10H

.580 ZPUMB 1

113 11C 10H

.580 ZPUMB 1

114 08H 09H

.610 ZPSNM 1

114 11C 10H

.580 ZPUMB 6

114 08H 09H

.610 ZPSNM 26 114 TSC 23C

.610 ZPSNM 1

115 11C 10H

.580 ZPUMB 3

115 10H 10H

.580 ZPUMB 14 115 02H 02H

.610 ZPSNM 1

116 11C 10H

.580 ZPUMB 1

117 11C 10H

.580 ZPUMB 2

117 11C 10H

.580 ZPUMB 1

118 11C 10H

.580 ZPUMB 1

119 11C 10H

.580 ZPUMB 2

119 11C 10H

.580 ZPUMB 1

120 11C 10H

.580 ZPUMB 4

120 11C 10H

.580 ZPUNM

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 1

1 10H 11C

.580 ZPUMB 1

2 10H 11C

.580 ZPUMB 1

3 10H 11C

.580 ZPUMB 2

3 11C 11C

.610 ZPSNM 13 3

11C 11C

.610 ZPSNM 16 3

11C 11C

.610 ZPSNM 16 3

12C 11C

.610 ZPSNM 1

4 10H 11C

.580 ZPUMB 8

4 10H AVI

.580 ZPUMB 1

5 10H 11C

.580 ZPUMB 16 5

11C 11C

.610 ZPSNM 18 5

11C 11C

.610 ZPSNM 1

6 10H 11C

.580 ZPUMB 10 6

03H 03H

.610 ZPSNM 1

7 10H 11C

.580 ZPUMB 1

7 11C 10H

.580 ZPUMB 7

7 05H 05H

.610 ZPSNM 1

8 10H 11C

.580 ZPUMB 4

8 01H 02H

.610 ZPSNM 1

9 10H 11C

.580 ZPUMB 1

10 10H 11C

.580 ZPUMB 8

10 11C AV4

.580 ZPUMB 10 10 03H 03H

.610 ZPSNM 15 10 02H 02H

.610 ZPSNM 1

11 10H 11C

.580 ZPUMB 8

11 02H 02H

.610 ZPSNM 11 11 02H 02H

.610 ZPSNM 12 11 02H 02H

.610 ZPSNM 15 11 02H 02H

.610 ZPSNM 18 11 02H 02H

.610 ZPSNM 1

12 10H 11C

.580 ZPUMB 2

12 10H 11C

.580 ZPUMB 21 12 11C 11C

.610 ZPSNM 1

13 10H 11C

.580 ZPUMB 1

13 11C 10H

.580 ZPUMB 16 13 02H 03H

.610 ZPSMB 17 13 02H 02H

.610 ZPSNM 23 13 02H 02H

.610 ZPSNM 1

14 10H 11C

.580 ZPUMB 10 14 02H 02H

.610 ZPSNM 10 14 03H 03H

.610 ZPSNM 10 14 05H 05H

.610 ZPSNM B-1 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 18 14 02H 02H

.610 ZPSNM 1

15 10H 11C

.580 ZPUMB 8

15 10H AV1

.580 ZPUMB 16 15 02H 02H

.610 ZPSNM 17 15 02H 02H

.610 ZPSNM 17 15 03H 03H

.610 ZPSNM 18 15 17C 16C

.610 ZPSNM 22 15 02H 02H

.610 ZPSNM 28 15 02H 02H

.610 ZPSNM 1

16 10H 11C

.580 ZPUMB 12 16 02H 02H

.610 ZPSNM 16 16 02H 02H

.610 ZPSNM 20 16 02H 02H

.610 ZPSNM 21 16 02H 02H

.610 ZPSNM 35 16 02H 02H

.610 ZPSNM 1

17 10H 11C

.580 ZPUMB 16 17 02H 02H

.610 ZPSNM 16 17 03H 03H

.610 ZPSNM 16 17 04H 04H

.610 ZPSNM 18 17 02H 02H

.610 ZPSNM 19 17 02H 02H

.610 ZPSNM 19 17 03H 03H

.610 ZPSNM 19 17 12C 11C

.610 ZPSMB 23 17 02H 02H

.610 ZPSNM 1

18 10H 11C

.580 ZPUMB 2

18 10H 11C

.580 ZPUMB 16 18 02H 02H

.610 ZPSNM 16 18 03H 03H

.610 ZPSNM 17 18 22C 21C

.610 ZPSNM 20 18 12C 11C

.610 ZPSMB 40 18 11C 11C

.580 ZPUMB 1

19 10H 11C

.580 ZPUMB 2

19 11C 10H

.580 ZPUMB 5

19 02H 02H

.610 ZPSNM 8

19 10H AV1

.580 ZPUMB 10 19 02H 02H

.610 ZPSNM 14 19 02H 02H

.610 ZPSNM 15 19 02H 02H

.610 ZPSNM 19 19 02H 02H

.610 ZPSNM 19 19 04H 04H

.610 ZPSNM 21 19 02H 02H

.610 ZPSNM 36 19 03H 03H

.610 ZPSNM B-2 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 39 19 09H 10H

.610 ZPSNM 1

20 10H 11C

.580 ZPUMB 14 20 04H 04H

.610 ZPSNM 1

21 10H 1 lC

.580 ZPUMB 14 21 03H 03H

.610 ZPSNM 17 21 04H 04H

.610 ZPSNM 1

22 10H 11C

.580 ZPUMB 6

22 04H 04H

.610 ZPSNM 12 22 09H 10H

.610 ZPSNM 12 22 12C 12C

.610 ZPSNM 14 22 02H 02H

.610 ZPSNM 15 22 02H 02H

.610 ZPSNM 15 22 11C 11C

.610 ZPSNM 15 22 20C 20C

.610 ZPSNM 16 22 03H 03H

.610 ZPSNM 17 22 02H 02H

.610 ZPSNM 17 22 04H 04H

.610 ZPSNM 22 22 04H 04H

.610 ZPSNM 25 22 02H 02H

.610 ZPSNM 26 22 03H 03H

.610 ZPSNM 27 22 02H 02H

.610 ZPSNM 34 22 03H 03H

.610 ZPSNM 37 22 17C 16C

.610 ZPSNM 43 22 21C 21C

.610 ZPSNM 43 22 22C 22C

.610 ZPSNM 1

23 10H 11C

.580 ZPUMB 13 23 02H 02H

.610 ZPSNM 20 23 03H 03H

.610 ZPSNM 27 23 02H 02H

.610 ZPSNM 30 23 TSH 01H

.610 ZPSNM 35 23 03H 03H

.610 ZPSNM 38 23 03H 03H

.610 ZPSNM 1

24 10H 11C

.580 ZPUMB 6

24 02H 02H

.610 ZPSNM 11 24 02H 02H

.610 ZPSNM 14 24 02H 02H

.610 ZPSNM 16 24 03H 03H

.610 ZPSNM 18 24 02H 02H

.610 ZPSNM 21 24 02H 02H

.610 ZPSNM 34 24 04H 04H

.610 ZPSNM 46 24 21C 21C

.610 ZPSNM 46 24 22C 22C

.610 ZPSNM B-3 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 1

25 10H 11C

.580 ZPUMB 14 25 03H 03H

.610 ZPSNM 17 25 04H 04H

.610 ZPSNM 46 25 21C 21C

.610 ZPSNM 46 25 22C 22C

.610 ZPSNM 1

26 10H 11C

.580 ZPUMB 13 26 02H 02H

.610 ZPSNM 13 26 06H 06H

.610 ZPSNM 13 26 11C 11C

.610 ZPSNM 13 26 21C 21C

.610 ZPSNM 16 26 02H 02H

.610 ZPSNM 32 26 02H 02H

.610 ZPSNM 35 26 02H 02H

.610 ZPSNM 37 26 02H 02H

.610 ZPSNM 43 26 09H 10H

.610 ZPSNM 43 26 10H 10H

.610 ZPSNM 1

27 10H 11C

.580 ZPUMB 2

27 10H 11C

.580 ZPUMB 10 27 02H 02H

.610 ZPSNM 11 27 11C AV4

.580 ZPUMB 18 27 03H 03H

.610 ZPSNM 20 27 04H 04H

.610 ZPSNM 22 27 02H 02H

.610 ZPSNM 22 27 03H 03H

.610 ZPSNM 44 27 22C 21C

.610 ZPSNM 1

28 10H 11C

.580 ZPUMB 11 28 02H 02H

.610 ZPSNM 12 28 02H 02H

.610 ZPSNM 14 28 02H 02H

.610 ZPSNM 14 28 03H 03H

.610 ZPSNM 20 28 02H 02H

.610 ZPSNM 24 28 02H 02H

.610 ZPSNM 41 28 09H 10H

.610 ZPSNM 41 28 11C 11C

.610 ZPSNM 43 28 11C 11C

.610 ZPSNM 46 28 11C 11C

.610 ZPSNM 1

29 10H 11C

.580 ZPUMB 17 29 03H 03H

.610 ZPSNM 17 29 12C lIC

.610 ZPSNM 20 29 02H 02H

.610 ZPSNM 20 29 05H 05H

.610 ZPSNM 38 29 02H 02H

.610 ZPSNM B-4 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 1

30 10H 11C

.580 ZPUMB 10 30 02H 02H

.610 ZPSNM 15 30 02H 02H

.610 ZPSNM 17 30 02H 02H

.610 ZPSNM 19 30 03H 03H

.610 ZPSNM 23 30 02H 02H

.610 ZPSNM 26 30 02H 02H

.610 ZPSNM 26 30 05H 05H

.610 ZPSNM 36 30 02H 02H

.610 ZPSNM 39 30 15C 13C

.610 ZPSNM 39 30 15C 15C

.610 ZPSNM 43 30 21C 21C

.610 ZPSNM 48 30 21C 21C

.610 ZPSNM 48 30 22C 22C

.610 ZPSNM 1

31 10H 11C

.580 ZPUMB 4

31 11C 11C

.580 ZPUMB 14 31 06H 06H

.610 ZPSNM 15 31 03H 03H

.610 ZPSNM 15 31 04H 04H

.610 ZPSNM 17 31 02H 02H

.610 ZPSNM 18 31 03H 03H

.610 ZPSNM 1

32 10H 11C

.580 ZPUMB 13 32 02H 02H

.610 ZPSNM 15 32 02H 02H

.610 ZPSNM 18 32 02H 02H

.610 ZPSNM 18 32 03H 03H

.610 ZPSNM 24 32 02H 02H

.610 ZPSNM 25 32 03H 03H

.610 ZPSNM 1

33 11C 10H

.580 ZPUMB 23 33 03H 03H

.610 ZPSNM 24 33 03H 03H

.610 ZPSNM 26 33 02H 02H

.610 ZPSNM 34 33 10H 10H

.610 ZPSNM 36 33 04H 04H

.610 ZPSNM 37 33 03H 03H

.610 ZPSNM 48 33 21C 21C

.610 ZPSNM 48 33 22C 22C

.610 ZPSNM 1

34 11C 10H

.580 ZPUMB 2

34 11C 10H

.580 ZPUMB A' n5.

"A 14 15 34 34 U/-i uzi-'

02H 02H 02H 02H

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM Appendix B B-5 14.

r--

O4 UZH

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 20 34 02H 02H

.610 ZPSNM 28 34 02H 02H

.610 ZPSNM 35 34 02H 02H

.610 ZPSNM 35 34 03H 03H

.610 ZPSNM 42 34 17C 16C

.610 ZPSNM 1

35 11C 10H

.580 ZPUMB 23 35 02H 02H

.610 ZPSNM 1

36 11C 10H

.580 ZPUMB 11 36 03H 03H

.610 ZPSNM 14 36 02H 02H

.610 ZPSNM 21 36 02H 02H

.610 ZPSNM 27 36 02H 02H

.610 ZPSNM 27 36 03H 03H

.610 ZPSNM 30 36 02H 02H

.610 ZPSNM 31 36 04H 04H

.610 ZPSNM 32 36 03H 03H

.610 ZPSNM 37 36 02H 02H

.610 ZPSNM 37 36 03H 03H

.610 ZPSNM 1

37 11C 10H

.580 ZPUMB 18 37 03H 03H

.610 ZPSNM 18 37 1IC 11C

.610 ZPSNM 19 37 02H 02H

.610 ZPSNM 19 37 04H 04H

.610 ZPSNM 21 37 02H 02H

.610 ZPSNM 27 37 02H 02H

.610 ZPSNM 1

38 11C 10H

.580 ZPUMB 16 38 11C 11C

.610 ZPSNM 16 38 11C 12C

.610 ZPSNM 17 38 02H 02H

.610 ZPSNM 23 38 02H 02H

.610 ZPSNM 23 38 03H 03H

.610 ZPSNM 28 38 03H 03H

.610 ZPSNM 38 38 02H 02H

.610 ZPSNM 39 38 11C 11C

.610 ZPSNM 45 38 03H 03H

.610 ZPSNM 1

39 11C 10H

.580 ZPUMB 17 39 02H 03H

.610 ZPSNM 18 39 03H 03H

.610 ZPSNM 19 39 02H 02H

.610 ZPSNM 21 39 04H 04H

.610 ZPSNM 22 39 02H 02H

.610 ZPSNM 23 39 03H 03H

.610 ZPSNM B-6 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 24 39 02H 02H

.610 ZPSNM 24 39 03H 03H

.610 ZPSNM 37 39 03H 03H

.610 ZPSNM 39 39 11C 11C

.610 ZPSNM 48 39 21C 21C

.610 ZPSNM 48 39 22C 22C

.610 ZPSNM 1

40 11C 10H

.580 ZPUMB 18 40 02H 02H

.610 ZPSNM 22 40 03H 03H

.610 ZPSNM 1

41 11C 10H

.580 ZPUMB 1

42 11C 10H

.580 ZPUMB 23 42 03H 03H

.610 ZPSNM 23 42 03H 04H

.610 ZPSNM 23 42 04H 04H

.610 ZPSNM 24 42 03H 03H

.610 ZPSNM 27 42 03H 03H

.610 ZPSNM 29 42 03H 03H

.610 ZPSNM 29 42 04H 04H

.610 ZPSNM 33 42 11C 11C

.610 ZPSNM 40 42 03H 03H

.610 ZPSNM 46 42 13C 12C

.610 ZPSNM 48 42 11C 11C

.610 ZPSNM 1

43 11C 10H

.580 ZPUMB 22 43 02H 02H

.610 ZPSNM 22 43 04H 04H

.610 ZPSNM 24 43 02H 02H

.610 ZPSNM 25 43 03H 03H

.610 ZPSNM 1

44 10H 11C

.580 ZPUMB 1

44 TSH 01H

.610 ZPSNM 20 44 02H 02H

.610 ZPSNM 28 44 03H 03H

.610 ZPSNM 29 44 03H 03H

.610 ZPSNM 32 44 04H 04H

.610 ZPSNM 34 44 09H 10H

.610 ZPSNM 1

45 lIC 10H

.580 ZPUMB 11 45 03H 04H

.610 ZPSMB 15 45 12C 11C

.610 ZPSMB 17 45 02H 02H

.610 ZPSNM 20 45 02H 02H

.610 ZPSNM 24 45 03H 03H

.610 ZPSNM 25 45 02H 02H

.610 ZPSNM 46 45 18C 17C

.610 ZPSNM B-7 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 48 45 21C 21C

.610 ZPSNM 48 45 22C 22C

.610 ZPSNM 1

46 11C 10H

.580 ZPUMB 22 46 04H 04H

.610 ZPSNM 1

47 11C 10H

.580 ZPUMB 2

47 11C 1OH

.580 ZPUMB 14 47 04H 04H

.610 ZPSNM 21 47 02H 02H

.610 ZPSNM 42 47 11C 11C

.610 ZPSNM 48 47 21C 21C

.610 ZPSNM 48 47 22C 22C

.610 ZPSNM 1

48 11C 110H

.580 ZPUMB 19 48 02H 02H

.610 ZPSNM 20 48 02H 02H

.610 ZPSNM 20 48 03H 03H

.610 ZPSNM 21 48 03H 03H

.610 ZPSNM 22 48 03H 03H

.610 ZPSNM 22 48 04H 04H

.610 ZPSNM 29 48 03H 03H

.610 ZPSNM 33 48 03H 03H

.610 ZPSNM 47 48 21C 21C

.610 ZPSNM 47 48 22C 22C

.610 ZPSNM 47 48 23C 22C

.610 ZPSNM 48 48 21C 21C

.610 ZPSNM 48 48 22C 22C

.610 ZPSNM 1

49 11C 101H

.580 ZPUMB 2

49 11C 10H

.580 ZPUMB 39 49 09H 10H

.610 ZPSNM 1

50 11C 10H

.580 ZPUMB 20 50 02H 02H

.610 ZPSNM 24 50 03H 03H

.610 ZPSNM 24 50 04H 04H

.610 ZPSNM 32 50 03H 03H

.610 ZPSNM 36 50 03H 03H

.610 ZPSNM 47 50 02H 02H

.610 ZPSNM 48 50 21C 21C

.610 ZPSNM 48 50 22C 22C

.610 ZPSNM 1

51 11C 10H

.580 ZPUMB 19 51 03H 03H

.610 ZPSNM 20 51 03H 03H

.610 ZPSNM 24 51 03H 03H

.610 ZPSNM 27 51 03H 03H

.610 ZPSNM B-8 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 27 51 04H 04H

.610 ZPSNM 27 51 05H 05H

.610 ZPSNM 29 51 TSH 01H

.610 ZPSNM 47 51 21C 21C

.610 ZPSNM 47 51 22C 22C

.610 ZPSNM 1

52 11C 10H

.580 ZPUMB 39 52 02H 02H

.610 ZPSNM 40 52 10H 1OH

.610 ZPSNM 42 52 02H 02H

.610 ZPSNM 1

53 11C 10H

.580 ZPUMB 19 53 02H 02H

.610 ZPSNM 25 53 03H 03H

.610 ZPSNM 37 53 03H 03H

.610 ZPSNM 39 53 02H 02H

.610 ZPSNM 1

54 11C 10H

.580 ZPUMB 20 54 02H 02H

.610 ZPSNM 25 54 03H 03H

.610 ZPSNM 27 54 04H 04H

.610 ZPSNM 28 54 03H 03H

.610 ZPSNM 33 54 02H 02H

.610 ZPSNM 37 54 04H 04H

.610 ZPSNM 39 54 04H 04H

.610 ZPSNM 44 54 03H 03H

.610 ZPSNM 45 54 02H 02H

.610 ZPSNM 46 54 21C 21C

.610 ZPSNM 46 54 22C 22C

.610 ZPSNM 1

55 11C 10H

.580 ZPUMB 16 55 02H 02H

.610 ZPSNM 17 55 09H 10H

.610 ZPSNM 32 55 04H 04H

.610 ZPSNM 1

56 11C 10H

.580 ZPUMB 19 56 09H 10H

.610 ZPSNM 24 56 03H 03H

.610 ZPSNM 24 56 04H 04H

.610 ZPSNM 34 56 03H 03H

.610 ZPSNM 48 56 21C 21C

.610 ZPSNM 48 56 22C 22C

.610 ZPSNM 1

57 11C 10H

.580 ZPUMB 28 57 02H 02H

.610 ZPSNM 28 57 03H 03H

.610 ZPSNM 1

58 11C 10H

.580 ZPUMB 2

58 11C 10H

.580 ZPUMB B-9 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 24 58 04H 04H

.610 ZPSNM 28 58 06H 06H

.610 ZPSNM 36 58 03H 03H

.610 ZPSNM 39 58 02H 02H

.610 ZPSNM 46 58 21C 21C

.610 ZPSNM 46 58 22C 22C

.610 ZPSNM 47 58 21C 21C

.610 ZPSNM 47 58 22C 22C

.610 ZPSNM 1

59 11C 10H

.580 ZPUMB 2

59 11C 10H

.580 ZPUMB 25 59 03H 03H

.610 ZPSNM 28 59 20C 20C

.610 ZPSNM 42 59 21C 21C

.610 ZPSNM 42 59 22C 22C

.610 ZPSNM 1

60 11C 10H

.580 ZPUMB 1

61 11C 10H

.580 ZPUMB 1

62 11C 10H

.580 ZPUMB 31 62 02H 02H

.610 ZPSNM 33 62 03H 03H

.610 ZPSNM 36 62 03H 03H

.610 ZPSNM 36 62 21C 21C

.610 ZPSNM 36 62 22C 22C

.610 ZPSNM 37 62 02H 02H

.610 ZPSNM 40 62 21C 21C

.610 ZPSNM 40 62 22C 22C

.610 ZPSNM 44 62 21C 21C

.610 ZPSNM 44 62 22C 22C

.610 ZPSNM 1

63 10H 11C

.580 ZPUMB 2

63 11C 10H

.580 ZPUMB 31 63 05H 05H

.610 ZPSNM 37 63 01H 02H

.610 ZPSNM 45 63 21C 21C

.610 ZPSNM 45 63 22C 22C

.610 ZPSNM 46 63 21C 21C

.610 ZPSNM 46 63 22C 22C

.610 ZPSNM 47 63 21C 21C

.610 ZPSNM 47 63 22C 22C

.610 ZPSNM 1

64 11C 10H

.580 ZPUMB 9

64 01H 02H

.610 ZPSNM 30 64 02H 02H

.610 ZPSNM 30 64 03H 03H

.610 ZPSNM 37 64 02H 02H

.610 ZPSNM B-10 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 44 64 03H 03H

.610 ZPSNM 1

65 11C 10H

.580 ZPUMB 33 65 02H 02H

.610 ZPSNM 33 65 04H 04H

.610 ZPSNM 40 65 02H 02H

.610 ZPSNM 46 65 21C 21C

.610 ZPSNM 46 65 22C 22C

.610 ZPSNM 1

66 11C 10H

.580 ZPUMB 25 66 02H 02H

.610 ZPSNM 35 66 11C 11C

.610 ZPSNM 40 66 09H 10H

.610 ZPSNM 1

67 11C 10H

.580 ZPUMB 8

67 01H 02H

.610 ZPSNM 30 67 02H 02H

.610 ZPSNM 37 67 21C 21C

.610 ZPSNM 39 67 02H 02H

.610 ZPSNM 47 67 21C 21C

.610 ZPSNM 47 67 22C 22C

.610 ZPSNM 1

68 10H 11C

.580 ZPUMB 5

68 01H 02H

.610 ZPSNM 23 68 04H 04H

.610 ZPSNM 1

69 11C 10H

.580 ZPUMB 35 69 02H 02H

.610 ZPSNM 36 69 03H 03H

.610 ZPSNM 38 69 02H 02H

.610 ZPSNM 44 69 10H 10H

.610 ZPSNM 46 69 10H 10H

.610 ZPSNM 46 69 21C 21C

.610 ZPSNM 1

70 11C 10H

.580 ZPUMB 6

70 01H 02H

.610 ZPSNM 19 70 05H 05H

.610 ZPSMB 41 70 04H 04H

.610 ZPSNM 48 70 21C 21C

.610 ZPSNM 48 70 22C 22C

.610 ZPSNM 1

71 11C 10H

.580 ZPUMB 28 71 03H 03H

.610 ZPSNM 46 71 02H 02H

.610 ZPSNM 46 71 10H 10H

.610 ZPSNM 1

72 11C 10H

.580 ZPUMB 20 72 10H 10H

.610 ZPSNM 23 72 03H 03H

.610 ZPSNM 35 72 11C 11C

.610 ZPSNM B-1I Appendix B

Appendix B Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 47 72 21C 21C

.610 ZPSNM 1

73 11C 10H

.580 ZPUMB 35 73 10H 10H

.610 ZPSNM 44 73 10H 10H

.610 ZPSNM 1

74 11C 10H

.580 ZPUMB 15 74 22C 22C

.610 ZPSNM 1

75 11C 10H

.580 ZPUMB 20 75 02H 02H

.610 ZPSNM 26 75 03H 03H

.610 ZPSNM 29 75 04H 04H

.610 ZPSNM 35 75 02H 02H

.610 ZPSNM 35 75 18C 19C

.610 ZPSNM 35 75 19C 19C

.610 ZPSNM 40 75 03H 03H

.610 ZPSNM 1

76 10H 11C

.580 ZPUMB 42 76 02H 02H

.610 ZPSNM 1

77 10H 11C

.580 ZPUMB 2

77 10H 11C

.580 ZPUMB 26 77 04H 04H

.610 ZPSNM 1

78 10H 11C

.580 ZPUMB 10 78 11C AV4

.580 ZPUMB 41 78 03H 03H

.610 ZPSNM 48 78 21C 21C

.610 ZPSNM 48 78 22C 22C

.610 ZPSNM 1

79 10H 11C

.580 ZPUMB 2

79 10H 11C

.580 ZPUMB 8

79 01H 02H

.610 ZPSNM 26 79 01H 02H

.610 ZPSNM 1

80 10H 11C

.580 ZPUMB 33 80 19C 18C

.610 ZPSNM 33 80 19C 19C

.610 ZPSNM 17 81 17C 16C

.610 ZPSNM 32 81 18C 19C

.610 ZPSNM 48 81 21C 21C

.610 ZPSNM 48 81 22C 22C

.610 ZPSNM 1

82 10H 11C

.580 ZPUMB 21 82 TSH 01H

.610 ZPSNM 32 82 03H 03H

.610 ZPSNM 32 82 11C 11C

.610 ZPSNM 35 82 02H 02H

.610 ZPSNM

'41 1 -J 04H 04H

.61 I

PN wU-I 1 1L

.8D 7PIJMR L _________________

1.

1 B-12 111.

.5I 7PUIM VIVI*

I 0z

.610 ZPSNM 01)

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 18 83 02H 02H

.610 ZPSNM 19 83 12C 11C

.610 ZPSNM 39 83 10H 10H

.610 ZPSNM 42 83 03H 03H

.610 ZPSNM 46 83 01H 01H

.610 ZPSNM 48 83 01H 02H

.610 ZPSNM 1

84 10H 11C

.580 ZPUMB 2

84 10H 11C

.580 ZPUMB 5

84 10H AV2

.580 ZPUMB 18 84 11C 11C

.610 ZPSNM 22 84 03H 03H

.610 ZPSNM 38 84 03H 03H

.610 ZPSNM 41 84 03H 03H

.610 ZPSNM 1

85 10H 11C

.580 ZPUMB 17 85 02H 02H

.610 ZPSNM 19 85 02H 02H

.610 ZPSNM 19 85 04H 04H

.610 ZPSNM 20 85 02H 02H

.610 ZPSNM 20 85 04H 04H

.610 ZPSNM 22 85 02H 02H

.610 ZPSNM 42 85 15C 14C

.610 ZPSMB 45 85 11C 11C

.610 ZPSNM 48 85 21C 21C

.610 ZPSNM 48 85 22C 22C

.610 ZPSNM 1

86 10H 11C

.580 ZPUMB 2

86 10H 11C

.580 ZPUMB 18 86 02H 02H

.610 ZPSNM 25 86 03H 03H

.610 ZPSNM 46 86 02H 02H

.610 ZPSNM 46 86 22C 22C

.610 ZPSNM 1

87 10H 11C

.580 ZPUMB 29 87 02H 02H

.610 ZPSNM 1

88 10H 11C

.580 ZPUMB 13 88 15C 14C

.610 ZPSMB 36 88 02H 02H

.610 ZPSNM 1

89 10H 11C

.580 ZPUMB 15 89 02H 02H

.610 ZPSNM 18 89 02H 02H

.610 ZPSNM 20 89 02H 02H

.610 ZPSNM 46 89 22C 22C

.610 ZPSNM 1

90 10H 11C

.580 ZPUMB 14 90 03H 03H

.610 ZPSNM B-13 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 18 90 04H 04H

.610 ZPSNM 22 90 16C 15C

.610 ZPSNM 34 90 02H 02H

.610 ZPSNM 41 90 11C 11C

.610 ZPSNM 1

91 10H 11C

.580 ZPUMB 2

91 10H 11C

.580 ZPUMB 12 91 02H 02H

.610 ZPSNM 14 91 02H 02H

.610 ZPSNM 14 91 04H 04H

.610 ZPSNM 20 91 02H 02H

.610 ZPSNM 36 91 11C 11C

.610 ZPSNM 48 91 21C 21C

.610 ZPSNM 48 91 22C 22C

.610 ZPSNM 1

92 10H 11C

.580 ZPUMB 2

92 10H 11C

.580 ZPUMB 8

92 20C 20C

.610 ZPSNM 12 92 02H 02H

.610 ZPSNM 12 92 03H 03H

.610 ZPSNM 45 92 14C 13C

.610 ZPSNM 1

93 10H 11C

.580 ZPUMB 14 93 02H 02H

.610 ZPSNM 16 93 02H 02H

.610 ZPSNM 17 93 03H 03H

.610 ZPSNM 27 93 02H 02H

.610 ZPSNM 30 93 11C 11C

.610 ZPSNM 48 93 21C 21C

.610 ZPSNM 48 93 22C 22C

.610 ZPSNM 1

94 10H 11C

.580 ZPUMB 11 94 02H 02H

.610 ZPSNM 20 94 03H 03H

.610 ZPSNM 43 94 11C 11C

.610 ZPSNM 1

95 10H 11C

.580 ZPUMB 2

95 10H 11C

.580 ZPUMB 17 95 02H 02H

.610 ZPSNM 1

96 10H 11C

.580 ZPUMB 12 96 02H 02H

.610 ZPSNM 12 96 04H 04H

.610 ZPSNM 15 96 02H 02H

.610 ZPSNM 46 96 20C 19C

.610 ZPSNM 1

97 10H 11C

.580 ZPUMB 16 97 02H 02H

.610 ZPSNM 16 97 03H 03H

.610 ZPSNM B-14 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 17 97 03H 03H

.610 ZPSNM 27 97 20C 20C

.610 ZPSNM 34 97 09H 10H

.610 ZPSNM 34 97 10H 10H

.610 ZPSNM 46 97 11C 11C

.610 ZPSNM 1

98 10H 11C

.580 ZPUMB 2

98 10H 11C

.580 ZPUMB 6

98 17C 16C

.610 ZPSNM 45 98 21C 21C

.610 ZPSNM 45 98 22C 22C

.610 ZPSNM 1

99 10H 11C

.580 ZPUMB 2

99 10H 11C

.580 ZPUMB 15 99 03H 03H

.610 ZPSNM 18 99 03H 03H

.610 ZPSNM 1

100 10H 11C

.580 ZPUMB 2

100 13C 12C

.610 ZPSNM 11 100 02H 02H

.610 ZPSNM 35 100 10H 10H

.610 ZPSNM 35 100 21C 20C

.610 ZPSNM 43 100 10H 10H

.610 ZPSNM 1

101 10H 11C

.580 ZPUMB 2

101 10H 11C

.580 ZPUMB 4

101 10H 10H

.580 ZPUMB 9

101 01H 02H

.610 ZPSNM 35 101 11C 11C

.610 ZPSNM 1

102 10H 11C

.580 ZPUMB 2

102 10H 11C

.580 ZPUMB 10 102 02H 02H

.610 ZPSNM 16 102 02H 02H

.610 ZPSNM 25 102 10H 10H

.610 ZPSNM 1

103 10H 11C

.580 ZPUMB 8

103 11C AV4

.580 ZPUMB 14 103 02H 02H

.610 ZPSNM 16 103 03H 03H

.610 ZPSNM 1

104 10H 1 lC

.580 ZPUMB 35 104 10H 10H

.610 ZPSNM 1

105 10H 11C

.580 ZPUMB 8

105 11C AV4

.580 ZPUMB 16 105 02H 02H

.610 ZPSNM 18 105 03H 03H

.610 ZPSNM 22 105 03H 03H

.610 ZPSNM 23 105 03H 03H

.610 ZPSNM B-15 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW COLUMN BEGIN TEST END TEST PROBE 1

106 10H 11C

.580 ZPUMB 14 106 02H 02H

.610 ZPSNM 14 106 03H 03H

.610 ZPSNM 16 106 03H 03H

.610 ZPSNM 23 106 17C 16C

.610 ZPSNM 27 106 01H 02H

.610 ZPSNM 1

107 10H 11C

.580 ZPUMB 10 107 02H 02H

.610 ZPSNM 23 107 11C lIC

.610 ZPSNM 1

108 10H 11C

.580 ZPUMB 11 108 02H 02H

.610 ZPSNM 17 108 03H 03H

.610 ZPSNM 1

109 10H 11C

.580 ZPUMB 2

109 10H 11C

.580 ZPUMB 10 109 02H 02H

.610 ZPSNM 10 109 03H 03H

.610 ZPSNM 12 109 03H 03H

.610 ZPSNM 34 109 TSC TSC

.610 ZPSNM 1

110 10H 11C

.580 ZPUMB 16 110 03H 03H

.610 ZPSNM 1

111 10H 11C

.580 ZPUMB 12 111 02H 02H

.610 ZPSNM 26 111 05H 05H

.610 ZPSNM 1

112 10H 11C

.580 ZPUMB 15 112 03H 03H

.610 ZPSNM 1

113 10H 11C

.580 ZPUMB 1

114 10H 11C

.580 ZPUMB 2

114 10H 11C

.580 ZPUMB 10 114 02H 02H

.610 ZPSNM 10 114 03H 03H

.610 ZPSNM 13 114 01H 02H

.610 ZPSNM 1

115 10H 11C

.580 ZPUMB 1

116 10H 11C

.580 ZPUMB 1

117 10H 11C

.580 ZPUMB 13 117 11C 11C

.610 ZPSNM 13 117 21C 20C

.610 ZPSNM 1

118 10H 11C

.580 ZPUMB 12 118 09H 10H

.610 ZPSNM 12 118 12C 11C

.610 ZPSNM 1

119 10H 11C

.580 ZPUMB 2

119 10H 11C

.580 ZPUMB 7

119 01H 02H

.610 ZPSNM B-16 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-B ROW jCOLUMN I BEGIN TEST END TEST PROBE 1

120 IOH 11C

.580 ZPUMB B-17 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 1

1 10H 11C

.580 ZPUMB 4

1 22C 22C

.610 ZPSNM 5

1 22C 22C

.610 ZPSNM 6

1 22C 22C

.610 ZPSNM 7

1 22C 22C

.610 ZPSNM 1

2 10H 11C

.580 ZPUMB 2

2 10H 11C

.580 ZPUMB 1

3 10H 11C

.580 ZPUMB 11 3

01H 02H

.610 ZPSNM 1

4 10H 11C

.580 ZPUMB 1

5 10H 11C

.580 ZPUMB 2

5 10H 11C

.580 ZPUMB 1

6 10H 11C

.580 ZPUMB 6

6 13C 12C

.610 ZPSNM 1

7 10H 11C

.580 ZPUMB 18 7

AVl 10H

.580 ZPUMB 1

8 10H 11C

.580 ZPUMB 2

8 10H 11C

.580 ZPUMB 15 8

02H 02H

.610 ZPSNM 24 8

AV1 10H

.580 ZPUMB 1

9 10H 11C

.580 ZPUMB 13 9

02H 02H

.610 ZPSNM 1

10 10H 11C

.580 ZPUMB 29 10 04H 05H

.610 ZPSMB 30 10 20C 19C

.610 ZPSNM 1

11 10H 11C

.580 ZPUMB 12 11 02H 02H

.610 ZPSNM 29 11 04H 05H

.610 ZPSMB 1

12 10H 11C

.580 ZPUMB 21 12 19C 17C

.610 ZPSNM 34 12 10H 10H

.610 ZPSNM 1

13 10H 11C

.580 ZPUMB 5

13 02H 02H

.610 ZPSNM 23 13 02H 02H

.610 ZPSNM 1

14 10H 11C

.580 ZPUMB 9

14 11C AV4

.580 ZPUNM 11 14 03H 03H

.610 ZPSNM 18 14 22C 21C

.610 ZPSNM 20 14 14C 12C

.610 ZPSNM 26 14 10H 10H

.610 ZPSNM 27 14 10H 10H

.610 ZPSNM 27 14 11C 11C

.610 ZPSNM B-1 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 1

15 10H 11C

.580 ZPUMB 3

15 22C 22C

.610 ZPSNM 1

16 10H 11C

.580 ZPUMB 2

16 10H 11C

.580 ZPUMB 3

16 22C 22C

.610 ZPSNM 31 16 17C 16C

.610 ZPSNM 39 16 TSC TSC

.610 ZPSNM 1

17 10H 11C

.580 ZPUMB 2

17 10H 11C

.580 ZPUMB 3

17 22C 22C

.610 ZPSNM 16 17 06H 07H

.610 ZPSNM 1

18 10H 11C

.580 ZPUMB 3

18 22C 22C

.610 ZPSNM 13 18 02H 02H

.610 ZPSNM 22 18 03H 03H

.610 ZPSNM 1

19 10H 11C

.580 ZPUMB 3

19 22C 22C

.610 ZPSNM 1

20 10H 11C

.580 ZPUMB 2

20 10H 11C

.580 ZPUMB 9

20 02H 02H

.610 ZPSNM 14 20 02H 02H

.610 ZPSNM 29 20 02H 02H

.610 ZPSNM 1

21 10H 11C

.580 ZPUMB 2

21 10H 11C

.580 ZPUMB 3

21 22C 22C

.610 ZPSNM 6

21 11C AV4

.580 ZPUNM 7

21 05H 05H

.610 ZPSNM 11 21 04H 04H

.610 ZPSNM 14 21 01H 02H

.610 ZPSNM 43 21 21C 21C

.610 ZPSNM 43 21 22C 22C

.610 ZPSNM 1

22 10H 11C

.580 ZPUMB 2

22 10H 11C

.580 ZPUMB 8

22 04H 04H

.610 ZPSNM 8

22 05H 05H

.610 ZPSNM 10 22 04H 04H

.610 ZPSNM 15 22 03H 03H

.610 ZPSNM 18 22 02H 02H

.610 ZPSNM 18 22 03H 03H

.610 ZPSNM 18 22 04H 04H

.610 ZPSNM 23 22 03H 03H

.610 ZPSNM 43 22 21C 21C

.610 ZPSNM B-2 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 43 22 22C 22C

.610 ZPSNM 44 22 21C 21C

.610 ZPSNM 44 22 22C 22C

.610 ZPSNM 1

23 10H 11C

.580 ZPUMB 13 23 03H 03H

.610 ZPSNM 13 23 04H 04H

.610 ZPSNM 13 23 06H 06H

.610 ZPSNM 22 23 02H 02H

.610 ZPSNM 23 23 02H 02H

.610 ZPSNM 23 23 03H 03H

.610 ZPSNM 38 23 11C 11C

.610 ZPSNM 44 23 21C 21C

.610 ZPSNM 44 23 22C 22C

.610 ZPSNM 45 23 21C 21C

.610 ZPSNM 45 23 22C 22C

.610 ZPSNM 1

24 10H 11C

.580 ZPUMB 2

24 10H 11C

.580 ZPUMB 24 24 02H 02H

.610 ZPSNM 32 24 03H 03H

.610 ZPSNM 37 24 04H 04H

.610 ZPSNM 46 24 21C 21C

.610 ZPSNM 46 24 22C 22C

.610 ZPSNM 1

25 10H 11C

.580 ZPUMB 2

25 10H 11C

.580 ZPUMB 15 25 03H 03H

.610 ZPSNM 27 25 01H 02H

.610 ZPSNM 27 25 04H 04H

.610 ZPSNM 27 25 04H 05H

.610 ZPSNM 46 25 21C 21C

.610 ZPSNM 46 25 22C 22C

.610 ZPSNM 1

26 10H 11C

.580 ZPUMB 21 26 03H 03H

.610 ZPSNM 47 26 21C 21C

.610 ZPSNM 47 26 22C 22C

.610 ZPSNM 1

27 10H 11C

.580 ZPUMB 13 27 11C AV4

.580 ZPUNM 14 27 02H 02H

.610 ZPSNM 21 27 AVi 10H

.580 ZPUMB 28 27 04H 05H

.610 ZPSMB 29 27 02H 02H

.610 ZPSNM 29 27 03H 03H

.610 ZPSNM 33 27 19C 19C

.610 ZPSNM B-3 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 41 27 10H 10H

.610 ZPSNM 47 27 21C 21C

.610 ZPSNM 47 27 22C 22C

.610 ZPSNM 48 27 21C 21C

.610 ZPSNM 48 27 22C 22C

.610 ZPSNM 1

28 10H 11C

.580 ZPUMB 12 28 02H 02H

.610 ZPSNM 27 28 01H 02H

.610 ZPSNM 37 28 03H 03H

.610 ZPSNM 48 28 21C 21C

.610 ZPSNM 48 28 22C 22C

.610 ZPSNM 1

29 10H 11C

.580 ZPUMB 16 29 02H 02H

.610 ZPSNM 47 29 21C 21C

.610 ZPSNM 48 29 21C 21C

.610 ZPSNM 48 29 22C 22C

.610 ZPSNM 1

30 10H 11C

.580 ZPUMB 9

30 05H 05H

.610 ZPSNM 28 30 04H 05H

.610 ZPSMB 37 30 04H 04H

.610 ZPSNM 48 30 21C 21C

.610 ZPSNM 48 30 22C 22C

.610 ZPSNM 1

31 10H 11C

.580 ZPUMB 20 31 04H 04H

.610 ZPSNM 21 31 21C 21C

.610 ZPSNM 27 31 01H 02H

.610 ZPSNM 48 31 21C 21C

.610 ZPSNM 48 31 22C 22C

.610 ZPSNM 1

32 10H 11C

.580 ZPUMB 17 32 02H 02H

.610 ZPSNM 48 32 21C 21C

.610 ZPSNM 48 32 22C 22C

.610 ZPSNM 1

33 10H 11C

.580 ZPUMB 40 33 04H 04H

.610 ZPSNM 48 33 21C 21C

.610 ZPSNM 48 33 22C 22C

.610 ZPSNM 1

34 10H 11C

.580 ZPUMB 19 34 04H 05H

.610 ZPSMB 25 34 04H 04H

.610 ZPSNM 27 34 02H 02H

.610 ZPSNM 37 34 02H 02H

.610 ZPSNM 37 34 04H 04H

.610 ZPSNM B-4 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 48 34 21C 21C

.610 ZPSNM 48 34 22C 22C

.610 ZPSNM 1

35 10H 11C

.580 ZPUMB 3

35 05H 05H

.610 ZPSNM 3

35 05H 06H

.610 ZPSNM 21 35 03H 03H

.610 ZPSNM 24 35 04H 04H

.610 ZPSNM 29 35 03H 03H

.610 ZPSNIV 30 35 04H 04H

.610 ZPSNM 44 35 02H 02H

.610 ZPSNM 44 35 04H 04H

.610 ZPSNM 48 35 21C 21C

.610 ZPSNM 48 35 22C 22C

.610 ZPSNM 1

36 10H 11C

.580 ZPUMB 39 36 03H 03H

.610 ZPSNM 48 36 21C 21C

.610 ZPSNM 48 36 22C 22C

.610 ZPSNM 1

37 10H 11C

.580 ZPUMB 2

37 01H 02H

.610 ZPSNM 25 37 03H 03H

.610 ZPSNM 26 37 03H 03H

.610 ZPSNM 30 37 02H 02H

.610 ZPSNM 30 37 04H 04H

.610 ZPSNM 36 37 04H 04H

.610 ZPSNM 36 37 07H 08H

.610 ZPSNM 48 37 11C AV3

.580 ZPUFU 48 37 21C 21C

.610 ZPSNM 48 37 22C 22C

.610 ZPSNM 1

38 10H 11C

.580 ZPUMB 2

38 10H 11C

.580 ZPUMB 21 38 02H 02H

.610 ZPSNM 27 38 04H 04H

.610 ZPSNM 44 38 02H 02H

.610 ZPSNM 48 38 21C 21C

.610 ZPSNM 48 38 22C 22C

.610 ZPSNM 1

39 10H lIC

.580 ZPUMB 25 39 03H 03H

.610 ZPSNM 48 39 21C 21C

.610 ZPSNM 48 39 22C 22C

.610 ZPSNM 1

40 10H 11C

.580 ZPUMB 20 40 02H 03H

.610 ZPSMB ao

-fu wl 03H

.610 ZPSNM B-5 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 30 40 02H 02H

.610 ZPSNM 30 40 04H 04H

.610 ZPSNM 48 40 21C 21C

.610 ZPSNM 48 40 22C 22C

.610 ZPSNM 1

41 10H 10H

.580 ZPUMB 1

41 10H 11C

.580 ZPUMB 21 41 17C 16C

.610 ZPSNM 48 41 21C 21C

.610 ZPSNM 48 41 22C 22C

.610 ZPSNM 1

42 10H 11C

.580 ZPUMB 22 42 04H 04H

.610 ZPSNM 28 42 04H 04H

.610 ZPSNM 48 42 21C 21C

.610 ZPSNM 48 42 22C 22C

.610 ZPSNM 1

43 10H 11C

.580 ZPUMB 21 43 02H 02H

.610 ZPSNM 34 43 02H 02H

.610 ZPSNM 47 43 21C 21C

.610 ZPSNM 47 43 22C 22C

.610 ZPSNM 48 43 21C 21C

.610 ZPSNM 48 43 22C 22C

.610 ZPSNM 1

44 10H 11C

.580 ZPUMB 2

44 10H 11C

.580 ZPUMB 26 44 01H 02H

.610 ZPSNM 28 44 AV3 10H

.580 ZPUMB 38 44 03H 03H

.610 ZPSNM 39 44 03H 03H

.610 ZPSNM 47 44 21C 21C

.610 ZPSNM 47 44 22C 22C

.610 ZPSNM 48 44 21C 21C

.610 ZPSNM 48 44 22C 22C

.610 ZPSNM 1

45 10H 10H

.580 ZPUMB 1

45 10H 11C

.580 ZPUMB 26 45 04H 04H

.610 ZPSNM 39 45 03H 03H

.610 ZPSNM 47 45 21C 21C

.610 ZPSNM 47 45 22C 22C

.610 ZPSNM 48 45 21C 21C

.610 ZPSNM 48 45 22C 22C

.610 ZPSNM 1

46 10H 10H

.580 ZPUMB 1

46 10H 11C

.580 ZPUMB 27 46 02H 02H

.610 ZPSNM B-6 Appendix B

Appendix B Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST 28 46 04H 47 46 21C 47 46 22C 48 46 21C 48 46 22C 1

47 1OH 7

47 12C 16 47 TSH 39 47 02H 47 47 21C 47 47 22C 48 47 21C 48 47 22C 1

48 10H 26 48 02H 26 48 03H 30 48 05H 40 48 11C 46 48 11C 47 48 21C 47 48 22C 48 48 21C 48 48 22C 1

49 1OH 31 49 02H 39 49 04H 47 49 21C 47 49 22C 48 49 21C 48 49 22C 1

50 1OH 39 50 03H 46 50 21 C 46 50 22C 47 50 21C 47 50 22C 48 50 21C 48 50 22C 1

51 10H 25 51 04H 26 51 03H 46 51 21C END TEST 04H 21C 22C 21C 22C 11C 12C 01H 02H 21C 22C 21C 22C 11C 02H 03H 05H 11C 11C 21C 22C 21C 22C 11C 02H 04H 21C 22C 21C 22C 11C 03H 21C 22C 21C 22C 21C 22C 11C 04H 03H 21C PROBE

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM 580 ZPUMB 610 ZPSNM 610 ZPSNM 610 ZPSNM B-7

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 46 51 22C 22C

.610 ZPSNM 47 51 21C 21C

.610 ZPSNM 47 51 22C 22C

.610 ZPSNM 48 51 21C 21C

.610 ZPSNM 48 51 22C 22C

.610 ZPSNM 1

52 10H 11C

.580 ZPUMB 17 52 04H 04H

.610 ZPSNM 25 52 03H 03H

.610 ZPSNM 35 52 03H 03H

.610 ZPSNMI 46 52 21C 21C

.610 ZPSNM 46 52 22C 22C

.610 ZPSNM 47 52 21C 21C

.610 ZPSNM 47 52 22C 22C

.610 ZPSNM 48 52 21C 21C

.610 ZPSNM 48 52 22C 22C

.610 ZPSNM 1

53 10H 11C

.580 ZPUMB 11 53 06H 08H

.610 ZPSNM 26 53 04H 04H

.610 ZPSNM 40 53 04H 04H

.610 ZPSNM 21C 22C 21C 22C 21C 22C 110 02H 17C 15C 02H 04H 02H 03H 04H 21C 22C 21C 22C 21C 22C 11C 03H

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM Appendix B B-8

"-tu 46 47 47 48 48 1

23 23 23 27 27 40 40 40 46 46 47 47 48 48 1

31 53 53 53 53 53 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 55 55 21C 22C 21C 22C 21C 22C 10H 02H 15C 17C 02H 04H 02H 03H 04H 21C 22C 21C 22C 21C 22C 10H 03H

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 46 55 21C 21C

.610 ZPSNM 46 55 22C 22C

.610 ZPSNM 47 55 21C 21C

.610 ZPSNM 47 55 22C 22C

.610 ZPSNM 48 55 21C 21C

.610 ZPSNM 48 55 22C 22C

.610 ZPSNM 1

56 10H 11C

.580 ZPUMB 2

56 10H lIC

.580 ZPUMB 7

56 09H 09H

.610 ZPSNM 8

56 12C 12C

.610 ZPSNM 27 56 02H 02H

.610 ZPSNM 29 56 01H 02H

.610 ZPSNM 32 56 AVI 10H

.580 ZPUMB 37 56 12C 11C

.610 ZPSNM 41 56 04H 04H

.610 ZPSNM 46 56 21C 21C

.610 ZPSNM 46 56 22C 22C

.610 ZPSNM 47 56 21C 21C

.610 ZPSNM 47 56 22C 22C

.610 ZPSNM 48 56 21C 21C

.610 ZPSNM 48 56 22C 22C

.610 ZPSNM 1

57 10H 11C

.580 ZPUMB 2

57 10H 11C

.580 ZPUMB 23 57 02H 02H

.610 ZPSNM 24 57 02H 02H

.610 ZPSNM 25 57 02H 02H

.610 ZPSNM 25 57 03H 03H

.610 ZPSNM 26 57 04H 04H

.610 ZPSNM 37 57 03H 03H

.610 ZPSNM 46 57 21C 21C

.610 ZPSNM 46 57 22C 22C

.610 ZPSNM 47 57 21C 21C

.610 ZPSNM 47 57 22C 22C

.610 ZPSNM 48 57 21C 21C

.610 ZPSNM 48 57 22C 22C

.610 ZPSNM 1

58 10H 11C

.580 ZPUMB 18 58 03H 04H

.610 ZPSNM 18 58 04H 04H

.610 ZPSNM 23 58 02H 02H

.610 ZPSNM 26 58 02H 02H

.610 ZPSNM 33 58 03H 03H

.610 ZPSNM 41 58 03H 03H

.610 ZPSNM B-9 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 45 58 21C 21C

.610 ZPSNM 45 58 22C 22C

.610 ZPSNM 46 58 21C 21C

.610 ZPSNM 46 58 22C 22C

.610 ZPSNM 47 58 21C 21C

.610 ZPSNM 47 58 22C 22C

.610 ZPSNM 48 58 21C 21C

.610 ZPSNM 48 58 22C 22C

.610 ZPSNM 1

59 10H 11C

.580 ZPUMB 24 59 09H 09H

.610 ZPSNM 24 59 09H 10H

.610 ZPSNM 36 59 21C 21C

.610 ZPSNM 36 59 22C 22C

.610 ZPSNM 37 59 21C 21C

.610 ZPSNM 37 59 22C 22C

.610 ZPSNM 38 59 21C 21C

.610 ZPSNM 38 59 22C 22C

.610 ZPSNM 39 59 21C 21C

.610 ZPSNM 39 59 22C 22C

.610 ZPSNM 40 59 21C 21C

.610 ZPSNM 40 59 22C 22C

.610 ZPSNM 41 59 21C 21C

.610 ZPSNM 41 59 22C 22C

.610 ZPSNM 42 59 21C 21C

.610 ZPSNM 42 59 22C 22C

.610 ZPSNM 43 59 21C 21C

.610 ZPSNM 43 59 22C 22C

.610 ZPSNM 44 59 21C 21C

.610 ZPSNM 44 59 22C 22C

.610 ZPSNM 45 59 21C 21C

.610 ZPSNM 45 59 22C 22C

.610 ZPSNM 46 59 21C 21C

.610 ZPSNM 46 59 22C 22C

.610 ZPSNM 47 59 21C 21C

.610 ZPSNM 47 59 22C 22C

.610 ZPSNM 48 59 21C 21C

.610 ZPSNM 48 59 22C 22C

.610 ZPSNM 1

60 10H 11C

.580 ZPUMB 20 60 TSC 23C

.610 ZPSNM 1

61 10H 11C

.580 ZPUMB 20 61 TSC 23C

.610 ZPSNM 1

62 10H 11C

.580 ZPUMB B-10 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 36 62 21C 21C

.610 ZPSNM 36 62 22C 22C

.610 ZPSNM 37 62 21C 21C

.610 ZPSNM 37 62 22C 22C

.610 ZPSNM 38 62 01H 02H

.610 ZPSNM 38 62 21C 21C

.610 ZPSNM 38 62 22C 22C

.610 ZPSNM 39 62 21C 21C

.610 ZPSNM 39 62 22C 22C

.610 ZPSNM 40 62 21C 21C

.610 ZPSNM 40 62 22C 22C

.610 ZPSNM 41 62 21C 21C

.610 ZPSNM 41 62 22C 22C

.610 ZPSNM 42 62 21C 21C

.610 ZPSNM 42 62 22C 22C

.610 ZPSNM 43 62 21C 21C

.610 ZPSNM 43 62 22C 22C

.610 ZPSNM 44 62 21C 21C

.610 ZPSNM 44 62 22C 22C

.610 ZPSNM 45 62 21C 21C

.610 ZPSNM 45 62 22C 22C

.610 ZPSNM 46 62 21C 21C

.610 ZPSNM 46 62 22C 22C

.610 ZPSNM 47 62 21C 21C

.610 ZPSNM 47 62 22C 22C

.610 ZPSNM 48 62 21C 21C

.610 ZPSNM 48 62 22C 22C

.610 ZPSNM 1

63 10H 11C

.580 ZPUMB 20 63 02H 02H

.610 ZPSNM 37 63 03H 03H

.610 ZPSNM 41 63 04H 04H

.610 ZPSNM 42 63 06H 06H

.610 ZPSNM 44 63 03H 03H

.610 ZPSNM 45 63 21C 21C

.610 ZPSNM 45 63 22C 22C

.610 ZPSNM 46 63 21C 21C

.610 ZPSNM 46 63 22C 22C

.610 ZPSNM 47 63 21C 21C

.610 ZPSNM 47 63 22C 22C

.610 ZPSNM 48 63 21C 21C

.610 ZPSNM 48 63 22C 22C

.610 ZPSNM 1

64 10H 11C

.580 ZPUMB B-11 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 10 64 20C 20C

.610 ZPSNM 19 64 04H 04H

.610 ZPSNM 41 64 03H 03H

.610 ZPSNM 41 64 04H 04H

.610 ZPSNM 42 64 04H 04H

.610 ZPSNM 46 64 21C 21C

.610 ZPSNM 46 64 22C 22C

.610 ZPSNM 47 64 21C 21C

.610 ZPSNM 47 64 22C 22C

.610 ZPSNM 48 64 21C 21C

.610 ZPSNM 48 64 22C 22C

.610 ZPSNM 1

65 10H 10H

.580 ZPUMB 1

65 10H 11C

.580 ZPUMB 29 65 07H 08H

.610 ZPSNM 39 65 05H 05H

.610 ZPSNM 41 65 03H 03H

.610 ZPSNM 41 65 04H 04H

.610 ZPSNM 45 65 03H 03H

.610 ZPSNM 46 65 21C 21C

.610 ZPSNM 46 65 220 220

.610 ZPSNM 47 65 21C 21C

.610 ZPSNM 47 65 22C 22C

.610 ZPSNM 48 65 21C 21C

.610 ZPSNM 48 65 22C 22C

.610 ZPSNM 1

66 10H 11C

.580 ZPUMB 2

66 10H 11C

.580 ZPUMB 6

66 09H 09H

.580 ZPSNM 7

66 09H 09H

.610 ZPSNM 7

66 09H 10H

.610 ZPSNM 17 66 03H 03H

.610 ZPSNM 36 66 02H 02H

.610 ZPSNM 39 66 03H 03H

.610 ZPSNM 39 66 04H 04H

.610 ZPSNM 45 66 03H 03H

.610 ZPSNM 46 66 21C 21C

.610 ZPSNM 46 66 22C 220

.610 ZPSNM 47 66 21C 21C

.610 ZPSNM 47 66 220 220

.610 ZPSNM 48 66 21C 21C

.610 ZPSNM 48 66 22C 220

.610 ZPSNM 1

67 10H 110

.580 ZPUMB 46 67 210C 210

.610 ZPSNM B-12 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 46 67 22C 22C

.610 ZPSNM 47 67 21C 21C

.610 ZPSNM 47 67 22C 22C

.610 ZPSNM 48 67 21C 21C

.610 ZPSNM 48 67 22C 22C

.610 ZPSNM 1

68 10H 11C

.580 ZPUMB 16 68 02H 02H

.610 ZPSNM 23 68 02H 02H

.610 ZPSNM 23 68 06H 06H

.610 ZPSNM 24 68 04H 04H

.610 ZPSNM 28 68 04H 04H

.610 ZPSNM 40 68 16C 15C

.610 ZPSNM 46 68 21C 21C

.610 ZPSNM 46 68 22C 22C

.610 ZPSNM 47 68 21C 21C

.610 ZPSNM 47 68 22C 22C

.610 ZPSNM 48 68 21C 21C

.610 ZPSNM 48 68 22C 22C

.610 ZPSNM 1

69 10H 11C

.580 ZPUMB 17 69 02H 02H

.610 ZPSNM 17 69 03H 03H

.610 ZPSNM 24 69 03H 03H

.610 ZPSNM 24 69 06H 06H

.610 ZPSNM 27 69 02H 02H

.610 ZPSNM 28 69 03H 03H

.610 ZPSNM 28 69 03H 04H

.610 ZPSNM 36 69 02H 02H

.610 ZPSNM 46 69 21C 21C

.610 ZPSNM 46 69 22C 22C

.610 ZPSNM 47 69 21C 21C

.610 ZPSNM 47 69 22C 22C

.610 ZPSNM 48 69 21C 21C

.610 ZPSNM 48 69 22C 22C

.610 ZPSNM 1

70 10H 11C

.580 ZPUMB 2

70 11C 10H

.580 ZPUMB 17 70 02H 02H

.610 ZPSNM 20 70 03H 03H

.610 ZPSNM 26 70 04H 04H

.610 ZPSNM 35 70 04H 04H

.610 ZPSNM 39 70 04H 04H

.610 ZPSNM 46 70 21C 21C

.610 ZPSNM 46 70 22C 22C

.610 ZPSNM B-13 Appendix B

Appendix B Tubes Examined By RPC at Locations Other than TSH S/G-C ROW A

-t I COLUMNI BEGIN TEST]

END TEST PROBE I

7t

I



1 I

I v

/LL 47 70 22C 22C

.610 ZPSNM 48 70 21C 21C

.610 ZPSNM 48 70 22C 22C

.610 ZPSNM 1

71 11C 10H

.580 ZPUMB 24 71 03H 03H

.610 ZPSNM 26 71 03H 03H

.610 ZPSNM 26 71 04H 04H

.610 ZPSNM 29 71 02H 02H

.610 ZPSNM 41 71 02H 02H

.610 ZPSNM 46 71 21 C 21C

.610 ZPSNM 46 71 22C 22C

.610 ZPSNM 47 71 21C 21 C

.610 ZPSNM 47 71 22C 22C

.610 ZPSNM 48 71 21 C 21 C

.610 ZPSNM 48 71 22C 22C

.610 ZPSNM 1

72 11C 10H

.580 ZPUMB 5

72 11C AV4

.580 ZPUNM 5

72 AV4 10H

.580 ZPUMB 6

72 AV4 10H

.580 ZPUMB 7

72 01H 02H

.610 ZPSNM 8

72-11C AV4

.580 ZPUNM 0

16 23 47 47 48 48 1

20 21 24 24 38 47 47 48 48 1

2 17 7L 72 72 72 72 72 72 73 73 73 73 73 73 73 73 73 73 74 74 74 AV 1 10H

.580 ZPUMB T

..

.4 U2H 03H 21C 22C 21C 22C 10H 02H 04H 02H 04H 02H 21C 22C 21C 22C 10H 10H 02H 02H 03H 21C 22C 21C 22C 110 02H 04H 02H 04H 02H 21C 22C 21C 22C 110 110 02H

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM B-14

.580 ZPUMB

.610 ZPSNM A

PROBE 21 C

.610 ZPSNM

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 17 74 03H 03H

.610 ZPSNM 26 74 02H 02H

.610 ZPSNM 26 74 03H 03H

.610 ZPSNM 26 74 04H 04H

.610 ZPSNM 39 74 21C 20C

.610 ZPSNM 43 74 02H 02H

.610 ZPSNM 43 74 03H 03H

.610 ZPSNM 47 74 21C 21C

.610 ZPSNM 47 74 22C 22C

.610 ZPSNM 48 74 21C 21C

.610 ZPSNM 48 74 22C 22C

.610 ZPSNM 1

75 10H 11C

.580 ZPUMB 2

75 10H 11C

.580 ZPUMB 15 75 01H 02H

.610 ZPSMB 15 75 03H 04H

.610 ZPSMB 15 75 04H 05H

.610 ZPSMB 15 75 08H 09H

.610 ZPSMB 33 75 03H 03H

.610 ZPSNM 33 75 09H 10H

.610 ZPSNM 41 75 03H 03H

.610 ZPSNM 43 75 11C AV2

.580 ZPUEU 44 75 02H 02H

.610 ZPSNM 47 75 21C 21C

.610 ZPSNM 47 75 22C 22C

.610 ZPSNM 48 75 21C 21C

.610 ZPSNM 48 75 22C 22C

.610 ZPSNM 1

76 10H 11C

.580 ZPUMB 24 76 03H 03H

.610 ZPSNM 25 76 02H 02H

.610 ZPSNM 31 76 04H 04H

.610 ZPSNM 36 76 03H 03H

.610 ZPSNM 47 76 21C 21C

.610 ZPSNM 47 76 22C 22C

.610 ZPSNM 48 76 21C 21C

.610 ZPSNM 48 76 22C 22C

.610 ZPSNM 1

77 10H 1 lC

.580 ZPUMB 20 77 03H 03H

.610 ZPSNM 22 77 03H 03H

.610 ZPSNM 24 77 03H 03H

.610 ZPSNM 25 77 03H 03H

.610 ZPSNM 47 77 21C 21C

.610 ZPSNM 47 77 22C 22C

.610 ZPSNM B-15 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 48 77 09H 09H

.610 ZPSNM 48 77 09H 10H

.610 ZPSNM 48 77 10H 10H

.610 ZPSNM 48 77 21C 21C

.610 ZPSNM 48 77 22C 22C

.610 ZPSNM 1

78 10H 11C

.580 ZPUMB 21 78 02H 02H

.610 ZPSNM 21 78 03H 03H

.610 ZPSNM 22 78 03H 03H

.610 ZPSNM 26 78 03H 03H

.610 ZPSNM 27 78 02H 02H

.610 ZPSNM 33 78 03H 03H

.610 ZPSNM 37 78 02H 02H

.610 ZPSNM 37 78 03H 03H

.610 ZPSNM 47 78 21C 21C

.610 ZPSNM 47 78 22C 22C

.610 ZPSNM 48 78 21C 21C

.610 ZPSNM 48 78 22C 22C

.610 ZPSNM 1

79 10H 11C

.580 ZPUMB 16 79 03H 04H

.610 ZPSNM 19 79 02H 02H

.610 ZPSNM 24 79 04H 04H

.610 ZPSNM 26 79 02H 02H

.610 ZPSNM 27 79 02H 02H

.610 ZPSNM 34 79 02H 02H

.610 ZPSNM 37 79 20C 20C

.610 ZPSNM 48 79 21C 21C

.610 ZPSNM 48 79 22C 22C

.610 ZPSNM 1

80 10H 11C

.580 ZPUMB 21 80 03H 03H

.610 ZPSNM 27 80 04H 04H

.610 ZPSNM 31 80 04H 04H

.610 ZPSNM 34 80 03H 03H

.610 ZPSNM 48 80 21C 21C

.610 ZPSNM 48 80 22C 21C

.610 ZPSNM 48 80 22C 22C

.610 ZPSNM 1

81 10H 11C

.580 ZPUMB 2

81 10H 11C

.580 ZPUMB 18 81 02H 02H

.610 ZPSNM 27 81 03H 03H

.610 ZPSNM 30 81 04H 04H

.610 ZPSNM 34 81 02H 02H

.610 ZPSNM B-16 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 36 81 03H 03H

.610 ZPSNM 38 81 02H 02H

.610 ZPSNM 48 81 21C 21C

.610 ZPSNM 48 81 22C 22C

.610 ZPSNM 1

82 10H 11C

.580 ZPUMB 34 82 14C 13C

.610 ZPSNM 36 82 03H 03H

.610 ZPSNM 37 82 03H 03H

.610 ZPSNM 39 82 11C 11C

.610 ZPSNM 45 82 02H 02H

.610 ZPSNM 48 82 21C 21C

.610 ZPSNM 48 82 22C 22C

.610 ZPSNM 1

83 10H 11C

.580 ZPUMB 27 83 02H 02H

.610 ZPSNM 31 83 03H 04H

.610 ZPSNM 44 83 01H 02H

.610 ZPSNM 48 83 21C 21C

.610 ZPSNM 48 83 22C 22C

.610 ZPSNM 1

84 10H 11C

.580 ZPUMB 25 84 03H 03H

.610 ZPSNM 35 84 02H 03H

.610 ZPSNM 48 84 21C 21C

.610 ZPSNM 48 84 22C 22C

.610 ZPSNM 1

85 10H 11C

.580 ZPUMB 18 85 02H 02H

.610 ZPSNM 20 85 03H 03H

.610 ZPSNM 25 85 04H 04H

.610 ZPSNM 28 85 02H 02H

.610 ZPSNM 28 85 03H 03H

.610 ZPSNM 29 85 03H 03H

.610 ZPSNM 42 85 01H 02H

.610 ZPSNM 48 85 21C 21C

.610 ZPSNM 48 85 22C 22C

.610 ZPSNM 1

86 10H 11C

.580 ZPUMB 17 86 02H 02H

.610 ZPSNM 18 86 02H 02H

.610 ZPSNM 24 86 03H 03H

.610 ZPSNM 29 86 03H 03H

.610 ZPSNM 30 86 01H 02H

.610 ZPSNM 38 86 01H 02H

.610 ZPSNM 42 86 12C 12C

.610 ZPSNM 42 86 21C 21C

.610 ZPSNM B-17 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 48 86 21C 21C

.610 ZPSNM 48 86 22C 22C

.610 ZPSNM 1

87 10H 11C

.580 ZPUMB 25 87 03H 03H

.610 ZPSNM 46 87 10H 10H

.610 ZPSNM 48 87 21C 21C

.610 ZPSNM 48 87 22C 22C

.610 ZPSNM 1

88 10H 11C

.580 ZPUMB 17 88 03H 03H

.610 ZPSNM 18 88 03H 03H

.610 ZPSNM 21 88 02H 02H

.610 ZPSNM 22 88 03H 03H

.610 ZPSNM 23 88 03H 03H

.610 ZPSNM 26 88 02H 02H

.610 ZPSNM 28 88 03H 03H

.610 ZPSNM 36 88 03H 03H

.610 ZPSNM 48 88 21C 21C

.610 ZPSNM 48 88 22C 22C

.610 ZPSNM 1

89 10H 11C

.580 ZPUMB 22 89 02H 02H

.610 ZPSNM 22 89 04H 04H

.610 ZPSNM 27 89 02H 02H

.610 ZPSNM 27 89 03H 03H

.610 ZPSNM 28 89 03H 03H

.610 ZPSNM 48 89 21C 21C

.610 ZPSNM 48 89 22C 22C

.610 ZPSNM 1

90 10H 11C

.580 ZPUMB 20 90 02H 02H

.610 ZPSNM 20 90 04H 04H

.610 ZPSNM 23 90 03H 03H

.610 ZPSNM 23 90 04H 04H

.610 ZPSNM 25 90 02H 02H

.610 ZPSNM 25 90 04H 04H

.610 ZPSNM 29 90 03H 03H

.610 ZPSNM 33 90 03H 03H

.610 ZPSNM 34 90 04H 04H

.610 ZPSNM 36 90 03H 03H

.610 ZPSNM 48 90 21C 21C

.610 ZPSNM 48 90 22C 22C

.610 ZPSNM 1

91 10H 11C

.580 ZPUMB 7

91 05H 05H

.610 ZPSNM 13 91 AV1 10H

.580 ZPUMB B-18 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 15 91 03H 03H

.610 ZPSNM 19 91 04H 04H

.610 ZPSNM 22 91 03H 03H

.610 ZPSNM 23 91 02H 02H

.610 ZPSNM 25 91 03H 03H

.610 ZPSNM 48 91 21C 21C

.610 ZPSNM 48 91 22C 22C

.610 ZPSNM 1

92 10H 11lC

.580 ZPUMB 19 92 02H 02H

.610 ZPSNM 22 92 04H 04H

.610 ZPSNM 22 92 05H 05H

.610 ZPSNM 23 92 02H 02H

.610 ZPSNM 23 92 11C 11C

.610 ZPSNM 24 92 02H 02H

.610 ZPSNM 24 92 11C 11lC

.610 ZPSNM 27 92 03H 03H

.610 ZPSNM 27 92 04H 04H

.610 ZPSNM 29 92 02H 02H

.610 ZPSNM 34 92 02H 02H

.610 ZPSNM 48 92 21C 21C

.610 ZPSNM 48 92 22C 22C

.610 ZPSNM 1

93 10H 11C

.580 ZPUMB 11 93 02H 02H

.610 ZPSNM 31 93 03H 04H

.610 ZPSNM 32 93 15C 14C

.610 ZPSNM 48 93 21C 21C

.610 ZPSNM 48 93 22C 22C

.610 ZPSNM 1

94 10H 11C

.580 ZPUMB 8

94 09H 09H

.610 ZPSNM 8

94 09H 10H

.610 ZPSNM 14 94 02H 02H

.610 ZPSNM 15 94 02H 02H

.610 ZPSNM 18 94 17C 16C

.610 ZPSNM 18 94 17C 17C

.610 ZPSNM 21 94 02H 02H

.610 ZPSNM 22 94 02H 02H

.610 ZPSNM 22 94 03H 03H

.610 ZPSNM 29 94 02H 02H

.610 ZPSNM 29 94 03H 03H

.610 ZPSNM 47 94 21C 21C

.610 ZPSNM 47 94 22C 22C

.610 ZPSNM 48 94 21C 21C

.610 ZPSNM B-19 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 48 94 22C 22C

.610 ZPSNM 48 94 TSC TSC

.610 ZPSNM 1

95 10H 11C

.580 ZPUMB 2

95 10H 11C

.580 ZPUMB 26 95 03H 03H

.610 ZPSNM 26 95 04H 04H

.610 ZPSNM 47 95 21C 21C

.610 ZPSNM 47 95 22C 22C

.610 ZPSNM 1

96 10H 11C

.580 ZPUMB 8

96 22C 21C

.610 ZPSMB 15 96 02H 02H

.610 ZPSNM 19 96 02H 02H

.610 ZPSNM 22 96 04H 04H

.610 ZPSNM 23 96 02H 02H

.610 ZPSNM 23 96 04H 04H

.610 ZPSNM 24 96 02H 02H

.610 ZPSNM 27 96 02H 02H

.610 ZPSNM 29 96 03H 03H

.610 ZPSNM 29 96 10H 10H

.610 ZPSNM 32 96 02H 02H

.610 ZPSNM 46 96 21C 21C

.610 ZPSNM 46 96 22C 22C

.610 ZPSNM 1

97 10H 11C

.580 ZPUMB 15 97 02H 02H

.610 ZPSNM 16 97 02H 02H

.610 ZPSNM 46 97 21C 21C

.610 ZPSNM 46 97 22C 22C

.610 ZPSNM 1

98 10H 11C

.580 ZPUMB 2

98 10H 11C

.580 ZPUMB 10 98 02H 02H

.610 ZPSNM 10 98 03H 03H

.610 ZPSNM 16 98 02H 02H

.610 ZPSNM 18 98 02H 02H

.610 ZPSNM 20 98 02H 02H

.610 ZPSNM 20 98 04H 04H

.610 ZPSNM 26 98 02H 02H

.610 ZPSNM 29 98 03H 03H

.610 ZPSNM 44 98 21C 21C

.610 ZPSNM 44 98 22C 22C

.610 ZPSNM 45 98 21C 21C

.610 ZPSNM 45 98 22C 22C

.610 ZPSNM 1

99 10H 11C

.580 ZPUMB B-20 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 15 99 07H 08H

.610 ZPSMB 17 99 02H 02H

.610 ZPSNM 30 99 02H 02H

.610 ZPSNM 36 99 11C 11C

.610 ZPSNM 43 99 21C 21C

.610 ZPSNM 43 99 22C 22C

.610 ZPSNM 44 99 21C 21C

.610 ZPSNM 44 99 22C 22C

.610 ZPSNM 1

100 10H 11C

.580 ZPUMB 11 100 02H 02H

.610 ZPSNM 17 100 03H 03H

.610 ZPSNM 22 100 02H 02H

.610 ZPSNM 23 100 02H 02H

.610 ZPSNM 29 100 01H 02H

.610 ZPSNM 43 100 21C 21C

.610 ZPSNM 43 100 22C 22C

.610 ZPSNM 1

101 10H 11C

.580 ZPUMB 14 101 03H 03H

.610 ZPSNM 16 101 02H 02H

.610 ZPSNM 17 101 02H 02H

.610 ZPSNM 20 101 04H 04H

.610 ZPSNM 33 101 03H 03H

.610 ZPSNM 34 101 10H 10H

.610 ZPSNM 34 101 11C 11C

.610 ZPSNM 12 102 13C 12C

.610 ZPSNM 15 102 16C 150

.610 ZPSNM 16 102 02H 02H

.610 ZPSNM 17 102 02H 02H

.610 ZPSNM 19 102 02H 02H

.610 ZPSNM 20 102 03H 03H

.610 ZPSNM 21 102 02H 02H

.610 ZPSNM 27 102 03H 03H

.610 ZPSNM 30 102 04H 04H

.610 ZPSNM 1

103 10H 11C

.580 ZPUMB 8

103 02H 02H

.610 ZPSNM 20 103 03H 03H

.610 ZPSNM 24 103 03H 03H

.610 ZPSNM 28 103 04H 04H

.610 ZPSNM 37 103 02H 02H

.610 ZPSNM 1

104 10H 11C

.580 ZPUMB 7

104 02H 02H

.610 ZPSNM I I I

I I

H I

06H

.610 ZPSNM B-2I Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-C ROW COLUMN BEGIN TEST END TEST PROBE 24 104 02H 02H

.610 ZPSNM 25 104 03H 03H

.610 ZPSNM 28 104 04H 04H

.610 ZPSNM 1

105 10H 11C

.580 ZPUMB 12 105 02H 02H

.610 ZPSNM 18 105 12C lIC

.610 ZPSNM 23 105 02H 02H

.610 ZPSNM 26 105 01H 02H

.610 ZPSNM 26 105 10H 10H

.610 ZPSNM 26 105 11C 11C

.610 ZPSNM 27 105 03H 03H

.610 ZPSNM 1

106 10H 11C

.580 ZPUMB 18 106 02H 02H

.610 ZPSNM 20 106 02H 02H

.610 ZPSNM 20 106 03H 03H

.610 ZPSNM 23 106 03H 03H

.610 ZPSNM 30 106 06H 07H

.610 ZPSNM 1

107 10H liC

.580 ZPUMB 2

107 05H 05H

.610 ZPSNM 2

107 10H 10H

.610 ZPSNM 2

107 10H 11C

.580 ZPUMB 7

107 13C 12C

.610 ZPSMB 10 107 02H 02H

.610 ZPSNM 19 107 03H 03H

.610 ZPSNM 26 107 04H 04H

.610 ZPSNM 34 107 10H 10H

.610 ZPSNM 1

108 10H 11C

.580 ZPUMB 11 108 02H 02H

.610 ZPSNM 13 108 02H 02H

.610 ZPSNM 15 108 02H 02H

.610 ZPSNM 18 108 02H 02H

.610 ZPSNM 19 108 03H 03H

.610 ZPSNM 28 108 10H 10H

.610 ZPSNM 1

109 10H 11C

.580 ZPUMB 8

109 02H 02H

.610 ZPSNM 9

109 02H 02H

.610 ZPSNM 16 109 02H 02H

.610 ZPSNM 1

110 10H 11C

.580 ZPUMB 8

110 02H 02H

.610 ZPSNM 11 110 02H 02H

.610 ZPSNM 12 110 02H 02H

.610 ZPSNM 21 110 03H 03H

.610 ZPSNM B-22 Appendix B

Tubes Examined Appendix B By RPC at Locations Other than TSH ROW 1

2 12 1

18 18 1

28 28 1

1 16 22 1

2 1

1 1

10 1

S/G-C COLUMN BEGIN TEST 111 10H 111 10H 111 02H 112 10H 112 02H 112 03H 113 10H 113 09H 113 10H 114 10H 115 10H 115 04H 115 16C 116 10H 116 10H 117 10H 118 10H 119 10H 119 02H 120 10H END TEST lic lic 02H 1iC 02H 03H lic 09H 10H lic lic 05H 15C lic lic i1C 1IC liC 02H lIC B-23 PROBE

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.580 ZPUMB

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.580 ZPUMB

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 1

1 11C 10H

.580 ZPUMB 2

1 10H 11C

.580 ZPUMB 7

1 01H 02H

.610 ZPSNM 1

2 10H 10H

.610 ZPSNM 1

2 10H 11C

.580 ZPUMB 1

2 11C 10H

.580 ZPSHF 1

2 11C 10H

.580 ZPUMB 2

2 10H 11C

.580 ZPUMB 3

2 05H 05H

.610 ZPSNM 4

2 09H 09H

.610 ZPSNM 7

2 11C 11C

.580 ZPUMB 9

2 09H 10H

.610 ZPSNM 9

2 12C 12C

.610 ZPSNM 12 2

16C 16C

.610 ZPSNM 13 2

23C 23C

.610 ZPSNM 1

3 10H 11C

.580 ZPUMB 1

3 15C 15C

.610 ZPSNM 1

3 16C 16C

.610 ZPSNM 2

3 10H 11C

.580 ZPUMB 13 3

22C 22C

.610 ZPSNM 13 3

23C 23C

.610 ZPSNM 14 3

10H 10H

.610 ZPSNM 15 3

06H 06H

.610 ZPSNM 15 3

09H 10H

.610 ZPSNM 16 3

10H 10H

.610 ZPSNM 1

4 10H 11C

.580 ZPUMB 2

4 10H 11C

.580 ZPUMB 12 4

23C 23C

.610 ZPSNM 14 4

09H 09H

.610 ZPSNM 14 4

09H 10H

.610 ZPSNM 1

5 10H 10H

.610 ZPSNM 1

5 10H 11C

.580 ZPUMB 2

5 10H 11C

.580 ZPUMB 7

5 17C 17C

.610 ZPSNM 9

5 16C 16C

.610 ZPSNM 12 5

05H 05H

.610 ZPSNM 12 5

05H 06H

.610 ZPSNM 12 5

16C 16C

.610 ZPSNM 1

6 10H 11C

.580 ZPUMB 2

6 10H 11C

.580 ZPUMB 12 6

09H 10H

.610 ZPSNM 13 6

11C 11C

.610 ZPSNM B-1 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 14 6

11C 11C

.610 ZPSNM 16 6

10H 10H

.610 ZPSNM 16 6

110 11C

.610 ZPSNM 1

7 10H 11C

.580 ZPUMB 2

7 10H 11C

.580 ZPUMB 13 7

09H 10H

.610 ZPSNM 14 7

09H 10H

.610 ZPSNM 21 7

05H 05H

.610 ZPSNM 26 7

11C 11C

.610 ZPSNM 1

8 10H 11C

.580 ZPUMB 2

8 10H 11C

.580 ZPUMB 7

8 03H 04H

.610 ZPSMB 8

8 02H 03H

.610 ZPSNM 9

8 09H 10H

.610 ZPSNM 9

8 15C 15C

.610 ZPSNM 14 8

09H 10H

.610 ZPSNM 15 8

09H 10H

.610 ZPSNM 23 8

05H 05H

.610 ZPSNM 26 8

11C 11C

.610 ZPSNM 26 8

12C 11C

.610 ZPSNM 1

9 10H 11C

.580 ZPUMB 2

9 10H 11C

.580 ZPUMB 10 9

05H 05H

.610 ZPSNM 10 9

16C 16C

.610 ZPSNM 10 9

20C 20C

.610 ZPSNM 13 9

01H 02H

.610 ZPSNM 24 9

05H 05H

.610 ZPSNM 29 9

16C 16C

.610 ZPSNM 1

10 10H 11C

.580 ZPUMB 1

10 11C 10H

.580 ZPSHF 1

10 18C 17C

.610 ZPSNM 2

10 10H 10H

.610 ZPSNM 2

10 10H 11C

.580 ZPUMB 2

10 11C 10H

.580 ZPSHF 2

10 11C 10H

.580 ZPUMB 6

10 16C 16C

.610 ZPSNM 11 10 05H 05H

.610 ZPSNM 12 10 16C 16C

.610 ZPSNM 13 10 09H 09H

.610 ZPSNM 13 10 09H 10H

.610 ZPSNM 13 10 10H 10H

.610 ZPSNM 13 10 12C 11C

.610 ZPSNM B-2 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 13 10 12C 12C

.610 ZPSNM 14 10 09H 10H

.610 ZPSNM 14 10 12C 12C

.610 ZPSNM 15 10 02H 02H

.610 ZPSNM 16 10 10H 10H

.580 ZPUMB 16 10 11C 11C

.610 ZPSNM 1

11 10H 11C

.580 ZPUMB 2

11 10H 11C

.580 ZPUMB 12 11 02H 02H

.610 ZPSNM 13 11 09H 10H

.610 ZPSNM 21 11 02H 02H

.610 ZPSNM 30 11 11C 11C

.610 ZPSNM 1

12 10H 11C

.580 ZPUMB 2

12 10H 11C

.580 ZPUMB 12 12 02H 02H

.610 ZPSNM 21 12 02H 02H

.610 ZPSNM 30 12 12C 11C

.610 ZPSNM 1

13 10H 11C

.580 ZPUMB 2

13 10H 11C

.580 ZPUMB 10 13 05H 05H

.610 ZPSNM 10 13 16C 16C

.610 ZPSNM 14 13 10H 1oH

.610 ZPSNM 20 13 12C 12C

.610 ZPSNM 23 13 10H 10H

.610 ZPSNM 27 13 10H 10H

.610 ZPSNM 31 13 11C 11C

.610 ZPSNM 31 13 13C 13C

.610 ZPSNM 35 13 16C 16C

.610 ZPSNM 1

14 10H 11C

.580 ZPUMB 2

14 10H 11C

.580 ZPUMB 14 14 15C 15C

.610 ZPSNM 19 14 02H 03H

.610 ZPSNM 19 14 12C 12C

.610 ZPSNM 19 14 20C 20C

.610 ZPSNM 21 14 02H 02H

.610 ZPSNM 30 14 10H 10H

.610 ZPSNM 34 14 05H 05H

.610 ZPSNM 35 14 03H 04H

.610 ZPSNM 1

15 10H 11C

.580 ZPUMB 1

15 11C 10H

.580 ZPSHF 2

15 10H 11C

.580 ZPUMB 13 15 02H 02H

.610 ZPSNM B-3 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 17 15 10H 10H

.610 ZPSNM 30 15 10H 10H

.610 ZPSNM 34 15 20C 20C

.610 ZPSNM 36 15 16C 16C

.610 ZPSNM 36 15 20C 19C

.610 ZPSNM 1

16 10H 11C

.580 ZPUMB 2

16 10H lIC

.580 ZPUMB 10 16 09H 10H

.610 ZPSNM 14 16 03H 03H

.610 ZPSNM 14 16 12C 11C

.610 ZPSNM 16 16 02H 02H

.610 ZPSNM 17 16 02H 02H

.610 ZPSNM 20 16 02H 02H

.610 ZPSNM 27 16 02H 02H

.610 ZPSNM 28 16 02H 02H

.610 ZPSNM 37 16 16C 16C

.610 ZPSNM 1

17 10H 11C

.580 ZPUMB 2

17 10H 11C

.580 ZPUMB 2

17 16C 16C

.610 ZPSNM 4

17 09H 10H

.610 ZPSNM 9

17 09H 10H

.610 ZPSNM 9

17 12C 11C

.610 ZPSNM 9

17 12C 12C

.610 ZPSNM 14 17 09H 10H

.610 ZPSNM 14 17 I1C 11C

.610 ZPSNM 24 17 02H 02H

.610 ZPSNM 26 17 02H 02H

.610 ZPSNM 30 17 02H 02H

.610 ZPSNM 1

18 10H 11C

.580 ZPUMB 2

18 10H 11C

.580 ZPUMB 4

18 12C 12C

.610 ZPSNM 10 18 20C 20C

.610 ZPSNM 13 18 09H 10H

.610 ZPSNM 21 18 02H 02H

.610 ZPSNM 29 18 02H 02H

.610 ZPSNM 29 18 11C 11C

.610 ZPSNM 1

19 10H 11C

.580 ZPUMB 2

19 10H 11C

.580 ZPUMB 2

19 13C 13C

.610 ZPSNM 15 19 11C 11C

.610 ZPSNM 32 19 03H 04H

.610 ZPSNM 32 19 04H 04H

.610 ZPSNM B-4 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 1

20 10H 11C

.580 ZPUMB 2

20 10H 11C

.580 ZPUMB 8

20 01H 02H

.610 ZPSNM 9

20 05H 05H

.610 ZPSNM 10 20 05H 05H

.610 ZPSNM 10 20 19C 19C

.610 ZPSNM 10 20 20C 20C

.610 ZPSNM 10 20 21C 21C

.610 ZPSNM 15 20 02H 02H

.610 ZPSNM 23 20 02H 02H

.610 ZPSNM 24 20 02H 02H

.610 ZPSNM 27 20 02H 02H

.610 ZPSNM 30 20 02H 02H

.610 ZPSNM 1

21 10H 11C

.580 ZPUMB 1

21 11C 10H

.580 ZPSHF 2

21 10H 1lC

.580 ZPUMB 2

21 11C 10H

.580 ZPSHF 11 21 11C 11C

.610 ZPSNM 17 21 02H 02H

.610 ZPSNM 32 21 03H 03H

.610 ZPSNM 40 21 01H 02H

.610 ZPSNM 40 21 09H 10H

.610 ZPSNM 43 21 11C 11C

.610 ZPSNM 1

22 10H 11C

.580 ZPUMB 2

22 10H 11C

.580 ZPUMB 10 22 21C 21C

.610 ZPSNM 18 22 02H 02H

.610 ZPSNM 19 22 02H 02H

.610 ZPSNM 20 22 02H 02H

.610 ZPSNM 29 22 03H 03H

.610 ZPSNM 31 22 11C 11C

.610 ZPSNM 37 22 02H 02H

.610 ZPSNM 44 22 11C 11C

.610 ZPSNM 1

23 10H 11C

.580 ZPUMB 2

23 10H 11C

.580 ZPUMB 17 23 02H 02H

.610 ZPSNM 21 23 02H 02H

.610 ZPSNM 43 23 11C 11C

.610 ZPSNM 44 23 11C 11C

.610 ZPSNM 44 23 21C 21C

.610 ZPSNM 44 23 22C 22C

.610 ZPSNM 45 23 21C 21C

.610 ZPSNM B-5 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 45 23 22C 22C

.610 ZPSNM 1

24 10H 11C

.580 ZPUMB 2

24 10H 11C

.580 ZPUMB 21 24 02H 02H

.610 ZPSNM 22 24 03H 03H

.610 ZPSNM 23 24 02H 02H

.610 ZPSNM 25 24 01H 01H

.610 ZPSNM 25 24 02H 02H

.610 ZPSNM 28 24 02H 02H

.610 ZPSNM 35 24 11C 11C

.610 ZPSNM 39 24 10H 10H

.610 ZPSNM 40 24 11C 11C

.610 ZPSNM 40 24 12C 11C

.610 ZPSNM 41 24 11C 11C

.610 ZPSNM 41 24 12C 11C

.610 ZPSNM 41 24 12C 12C

.610 ZPSNM 43 24 10H 10H

.610 ZPSNM 44 24 11C 11C

.610 ZPSNM 1

25 10H 11C

.580 ZPUMB 1

25 11C 10H

.580 ZPSHF 2

25 10H 11C

.580 ZPUMB 18 25 04H 05H

.610 ZPSNM 21 25 03H 03H

.610 ZPSNM 23 25 02H 02H

.610 ZPSNM 36 25 02H 02H

.610 ZPSNM 37 25 22C 22C

.610 ZPSNM 40 25 18C 17C

.610 ZPSNM 43 25 04H 04H

.610 ZPSNM 43 25 11C 11C

.610 ZPSNM 44 25 11C 11C

.610 ZPSNM 46 25 11C 11C

.610 ZPSNM 46 25 17C 17C

.610 ZPSNM 46 25 21C 21C

.610 ZPSNM 46 25 22C 22C

.610 ZPSNM 1

26 10H 11C

.580 ZPUMB 1

26 11C 10H

.580 ZPSHF 2

26 10H 11C

.580 ZPUMB 14 26 02H 02H

.610 ZPSNM 14 26 03H 03H

.610 ZPSNM 16 26 02H 02H

.610 ZPSNM 17 26 02H 02H

.610 ZPSNM 17 26 03H 03H

.610 ZPSNM B-6 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 19 26 02H 02H

.610 ZPSNM 19 26 03H 03H

.610 ZPSNM 23 26 02H 02H

.610 ZPSNM 23 26 03H 03H

.610 ZPSNM 24 26 02H 02H

.610 ZPSNM 26 26 02H 02H

.610 ZPSNM 29 26 03H 03H

.610 ZPSNM 33 26 02H 02H

.610 ZPSNM 34 26 02H 02H

.610 ZPSNM 41 26 22C 22C

.610 ZPSNM 45 26 11C 11C

.610 ZPSNM 46 26 11C 11C

.610 ZPSNM 47 26 11C 11C

.610 ZPSNM 1

27 10H 11C

.580 ZPUMB 2

27 10H 11C

.580 ZPUMB 9

27 08H 09H

.610 ZPSNM 13 27 02H 02H

.610 ZPSNM 13 27 03H 03H

.610 ZPSNM 13 27 16C 16C

.610 ZPSNM 21 27 02H 03H

.610 ZPSNM 22 27 02H 02H

.610 ZPSNM 22 27 03H 03H

.610 ZPSNM 26 27 03H 03H

.610 ZPSNM 44 27 01H 02H

.610 ZPSNM 44 27 TSH 01H

.610 ZPSNM 1

28 10H 11C

.580 ZPUMB 1

28 11C 10H

.580 ZPUMB 2

28 10H 11C

.580 ZPUMB 2

28 11C 10H

.580 ZPUMB 14 28 02H 02H

.610 ZPSNM 14 28 05H 06H

.610 ZPSNM 15 28 02H 02H

.610 ZPSNM 16 28 03H 03H

.610 ZPSNM 16 28 04H 04H

.610 ZPSNM 20 28 02H 02H

.610 ZPSNM 20 28 04H 04H

.610 ZPSNM 23 28 04H 04H

.610 ZPSNM 25 28 09H 09H

.610 ZPSNM 27 28 02H 02H

.610 ZPSNM 27 28 04H 04H

.610 ZPSNM 28 28 03H 03H

.610 ZPSNM 29 28 02H 02H

.610 ZPSNM B-7 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 30 28 02H 02H

.610 ZPSNM 30 28 04H 04H

.610 ZPSNM 31 28 06H 06H

.610 ZPSNM 1

29 11C 10H

.580 ZPUMB 2

29 10H 11C

.580 ZPUMB 29 29 03H 03H

.610 ZPSNM 29 29 04H 05H

.610 ZPSNM 34 29 02H 02H

.610 ZPSNM 47 29 09H 10H

.610 ZPSNM 47 29 10H 10H

.610 ZPSNM 48 29 21C 21C

.610 ZPSNM 48 29 22C 22C

.610 ZPSNM 1

30 10H 11C

.580 ZPUMB 1

30 11C 10H

.580 ZPUMB 2

30 10H 11C

.580 ZPUMB 5

30 14C 14C

.610 ZPSNM 5

30 18C 18C

.610 ZPSNM 16 30 02H 02H

.610 ZPSNM 22 30 02H 02H

.610 ZPSNM 27 30 03H 03H

.610 ZPSNM 28 30 03H 03H

.610 ZPSNM 35 30 03H 03H

.610 ZPSNM 1

31 1IC 10H

.580 ZPUMB 2

31 10H 11C

.580 ZPUMB 15 31 03H 03H

.610 ZPSNM 16 31 02H 02H

.610 ZPSNM 18 31 02H 02H

.610 ZPSNM 21 31 02H 02H

.610 ZPSNM 21 31 03H 03H

.610 ZPSNM 30 31 02H 02H

.610 ZPSNM 30 31 03H 03H

.610 ZPSNM 32 31 03H 04H

.610 ZPSNM 37 31 03H 03H

.610 ZPSNM 48 31 21C 21C

.610 ZPSNM 48 31 22C 22C

.610 ZPSNM 1

32 11C 10H

.580 ZPUMB 2

32 04H 05H

.610 ZPSNM 2

32 10H 1 lC

.580 ZPUMB 6

32 16C 16C

.610 ZPSNM 20 32 02H 02H

.610 ZPSNM 22 32 02H 02H

.610 ZPSNM 22 32 04H 04H

.610 ZPSNM B-8 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 23 32 02H 02H

.610 ZPSNM 23 32 03H 03H

.610 ZPSNM 25 32 02H 02H

.610 ZPSNM 37 32 16C 16C

.610 ZPSNM 1

33 11C 10H

.580 ZPUMB 2

33 10H 11C

.580 ZPUMB 19 33 02H 02H

.610 ZPSNM 19 33 03H 03H

.610 ZPSNM 20 33 04H 04H

.610 ZPSNM 22 33 03H 03H

.610 ZPSNM 24 33 03H 03H

.610 ZPSNM 26 33 02H 02H

.610 ZPSNM 26 33 03H 03H

.610 ZPSNM 27 33 02H 02H

.610 ZPSNM 1

34 11C 10H

.580 ZPUMB 2

34 10H 11C

.580 ZPUMB 18 34 03H 03H

.610 ZPSNM 27 34 03H 03H

.610 ZPSNM 29 34 02H 02H

.610 ZPSNM 30 34 03H 03H

.610 ZPSNM 34 34 10H 10H

.610 ZPSNM 1

35 11C 10H

.580 ZPUMB 2

35 10H 11C

.580 ZPUMB 16 35 02H 02H

.610 ZPSNM 17 35 03H 03H

.610 ZPSNM 18 35 03H 03H

.610 ZPSNM 24 35 02H 02H

.610 ZPSNM 25 35 03H 03H

.610 ZPSNM 1

36 11C 10H

.580 ZPUMB 2

36 01H 01H

.610 ZPSNM 2

36 10H 11C

.580 ZPUMB 9

36 22C 22C

.610 ZPSNM 15 36 03H 03H

.610 ZPSNM 22 36 02H 02H

.610 ZPSNM 29 36 03H 03H

.610 ZPSNM 1

37 11C 10H

.580 ZPUMB 2

37 10H 11C

.580 ZPUMB 19 37 03H 03H

.610 ZPSNM 22 37 09H 10H

.610 ZPSNM 23 37 04H 04H

.610 ZPSNM 29 37 03H 03H

.610 ZPSNM 40 37 07H 07H

.610 ZPSNM B-9 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 1

38 11C 10H

.580 ZPUMB 2

38 10H 11C

.580 ZPUMB 16 38 04H 05H

.610 ZPSNM 17 38 03H 03H

.610 ZPSNM 23 38 03H 03H

.610 ZPSNM 25 38 02H 02H

.610 ZPSNM 25 38 03H 03H

.610 ZPSNM 30 38 12C 11C

.610 ZPSNM 1

39 10H 11C

.580 ZPUMB 2

39 10H 11C

.580 ZPUMB 18 39 02H 02H

.610 ZPSNM 19 39 02H 02H

.610 ZPSNM 22 39 02H 02H

.610 ZPSNM 23 39 02H 02H

.610 ZPSNM 25 39 02H 03H

.610 ZPSNM 32 39 01H 02H

.610 ZPSNM 32 39 02H 02H

.610 ZPSNM 38 39 03H 03H

.610 ZPSNM 1

40 10H 11C

.580 ZPUMB 2

40 10H 11C

.580 ZPUMB 19 40 02H 02H

.610 ZPSNM 20 40 03H 03H

.610 ZPSNM 26 40 03H 03H

.610 ZPSNM 27 40 02H 02H

.610 ZPSNM 27 40 03H 03H

.610 ZPSNM 31 40 03H 03H

.610 ZPSNM 1

41 10H 1 lC

.580 ZPUMB 2

41 10H 11C

.580 ZPUMB 19 41 03H 03H

.610 ZPSNM 25 41 03H 03H

.610 ZPSNM 26 41 02H 02H

.610 ZPSNM 26 41 03H 03H

.610 ZPSNM 35 41 05H 05H

.610 ZPSNM 2

42 10H 11C

.580 ZPUMB 19 42 03H 03H

.610 ZPSNM 20 42 02H 02H

.610 ZPSNM 23 42 02H 02H

.610 ZPSNM 24 42 03H 03H

.610 ZPSNM 27 42 01H 02H

.610 ZPSNM 29 42 02H 02H

.610 ZPSNM 29 42 03H 03H

.610 ZPSNM 41 42 04H 04H

.610 ZPSNM B-10 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 1

43 10H 11C

.580 ZPUMB 2

43 10H 11C

.580 ZPUMB 25 43 02H 02H

.610 ZPSNM 25 43 03H 03H

.610 ZPSNM 45 43 10H 10H

.610 ZPSNM 46 43 10H 10H

.610 ZPSNM 1

44 10H 11C

.580 ZPUMB 2

44 10H 11C

.580 ZPUMB 13 44 11C 11C

.610 ZPSNM 40 44 06H 06H

.610 ZPSNM 1

45 10H 11C

.580 ZPUMB 2

45 10H 11C

.580 ZPUMB 20 45 02H 02H

.610 ZPSNM 24 45 05H 05H

.610 ZPSNM 27 45 02H 02H

.610 ZPSNM 38 45 14C 13C

.610 ZPSNM 38 45 14C 14C

.610 ZPSNM 38 45 17C 17C

.610 ZPSNM 38 45 20C 20C

.610 ZPSNM 1

46 10H 11C

.580 ZPUMB 2

46 10H 10H

.610 ZPSNM 2

46 10H 1 lC

.580 ZPUMB 23 46 02H 02H

.610 ZPSNM 23 46 03H 03H

.610 ZPSNM 24 46 03H 03H

.610 ZPSNM 27 46 02H 02H

.610 ZPSNM 27 46 03H 03H

.610 ZPSNM 47 46 21C 21C

.610 ZPSNM 47 46 22C 22C

.610 ZPSNM 1

47 10H 11C

.580 ZPUMB 2

47 10H 11C

.580 ZPUMB 22 47 02H 02H

.610 ZPSNM 24 47 02H 03H

.610 ZPSNM 25 47 02H 02H

.610 ZPSNM 25 47 02H 03H

.610 ZPSNM 27 47 02H 02H

.610 ZPSNM 29 47 03H 03H

.610 ZPSNM 1

48 10H 11C

.580 ZPUMB 2

48 10H 11C

.580 ZPUMB 48 48 21C 21C

.610 ZPSNM 48 48 22C 22C

.610 ZPSNM 4

A.'.I*..

lUll 1W

.1. _______________

1.580 ZPUMB B-Il Appendix B I

14 V 11G

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 2

49 10H 11C

.580 ZPUMB 5

49 09H 10H

.610 ZPSNM 25 49 02H 02H

.610 ZPSNM 25 49 03H 03H

.610 ZPSNM 33 49 04H 04H

.610 ZPSNM 47 49 21C 21C

.610 ZPSNM 47 49 22C 22C

.610 ZPSNM 48 49 21C 21C

.610 ZPSNM 48 49 22C 22C

.610 ZPSNM 2

50 10H 11C

.580 ZPUMB 26 50 03H 03H

.610 ZPSNM 28 50 03H 03H

.610 ZPSNM 46 50 21C 21C

.610 ZPSNM 46 50 22C 22C

.610 ZPSNM 48 50 21C 21C

.610 ZPSNM 48 50 22C 22C

.610 ZPSNM 1

51 10H 11C

.580 ZPUMB 2

51 10H 11C

.580 ZPUMB 13 51 01H 02H

.610 ZPSNM 46 51 21C 21C

.610 ZPSNM 46 51 22C 22C

.610 ZPSNM 47 51 21C 21C

.610 ZPSNM 47 51 22C 22C

.610 ZPSNM 1

52 10H 11C

.580 ZPUMB 2

52 10H 1 lC

.580 ZPUMB 7

52 08H 09H

.610 ZPSNM 36 52 02H 02H

.610 ZPSNM 1

53 10H 11C

.580 ZPUMB 1

53 13C 12C

.610 ZPSNM 2

53 10H 11C

.580 ZPUMB 25 53 02H 02H

.610 ZPSNM 46 53 21C 21C

.610 ZPSNM 46 53 22C 22C

.610 ZPSNM 1

54 10H 11C

.580 ZPUMB 2

54 10H 11C

.580 ZPUMB 30 54 03H 03H

.610 ZPSNM 35 54 03H 03H

.610 ZPSNM 1

55 10H 11C

.580 ZPUMB 2

55 1OH 11C

.580 ZPUMB 18 55 02H 02H

.610 ZPSNM 24 55 04H 04H

.610 ZPSNM 29 55 03H 03H

.610 ZPSNM B-12 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 37 55 02H 02H

.610 ZPSNM 37 55 03H 03H

.610 ZPSNM 40 55 01H 01H

.610 ZPSNM 46 55 21C 21C

.610 ZPSNM 46 55 22C 22C

.610 ZPSNM 48 55 21C 21C

.610 ZPSNM 48 55 22C 22C

.610 ZPSNM 1

56 10H 11C

.580 ZPUMB 2

56 10H 11C

.580 ZPUMB 26 56 02H 02H

.610 ZPSNM 26 56 03H 03H

.610 ZPSNM 26 56 04H 04H

.610 ZPSNM 26 56 05H 05H

.610 ZPSNM 30 56 04H 04H

.610 ZPSNM 39 56 02H 02H

.610 ZPSNM 1

57 10H 10H

.580 ZPUMB 1

57 10H 11C

.580 ZPUMB 2

57 10H 11C

.580 ZPUMB 1

58 10H 11C

.580 ZPUMB 2

58 10H 11C

.580 ZPUMB 23 58 04H 04H

.610 ZPSNM 28 58 03H 03H

.610 ZPSNM 1

59 10H 11C

.580 ZPUMB 2

59 10H 11C

.580 ZPUMB 31 59 01H 02H

.610 ZPSNM 43 59 21C 21C

.610 ZPSNM 43 59 22C 22C

.610 ZPSNM 48 59 21C 21C

.610 ZPSNM 48 59 22C 22C

.610 ZPSNM 1

60 10H 11C

.580 ZPUMB 2

60 10H 11C

.580 ZPUMB 10 60 22C 22C

.610 ZPSNM 20 60 TSC 23C

.610 ZPSNM 20 60 TSC TSC

.610 ZPSNM 1

61 10H 11C

.580 ZPUMB 2

61 10H 11C

.580 ZPUMB 1

62 10H 11C

.580 ZPUMB 2

62 10H 11C

.580 ZPUMB 44 62 21C 21C

.610 ZPSNM 44 62 22C 22C

.610 ZPSNM 1

63 10H 11C

.580 ZPUMB 2

63 10H 11C

.580 ZPUMB B-13 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 5

63 08H 09H

.610 ZPSMB 26 63 04H 04H

.610 ZPSNM 29 63 02H 02H

.610 ZPSNM 1

64 10H lIC

.580 ZPUMB 2

64 10H 1lC

.580 ZPUMB 8

64 05H 06H

.610 ZPSNM 27 64 04H 04H

.610 ZPSNM 34 64 10H 10H

.610 ZPSNM 40 64 03H 03H

.610 ZPSNM 40 64 05H 05H

.610 ZPSNM 48 64 21C 21C

.610 ZPSNM 48 64 22C 22C

.610 ZPSNM 1

65 10H 11C

.580 ZPUMB 2

65 10H 11C

.580 ZPUMB 30 65 03H 03H

.610 ZPSNM 35 65 03H 03H

.610 ZPSNM 48 65 21C 21C

.610 ZPSNM 48 65 22C 22C

.610 ZPSNM 1

66 10H lIC

.580 ZPUMB 2

66 10H lIC

.580 ZPUMB 26 66 03H 03H

.610 ZPSNM 38 66 05H 05H

.610 ZPSNM 38 66 06H 07H

.610 ZPSNM 42 66 05H 05H

.610 ZPSNM 1

67 10H lIC

.580 ZPUMB 2

67 10H lIC

.580 ZPUMB 26 67 04H 04H

.610 ZPSNM 36 67 03H 03H

.610 ZPSNM 47 67 02H 03H

.610 ZPSNM 1

68 10H liC

.580 ZPUMB 1

68 lIC 10H

.580 ZPUMB 2

68 10H 1IC

.580 ZPUMB 24 68 04H 04H

.610 ZPSNM 27 68 03H 03H

.610 ZPSNM 40 68 02H 02H

.610 ZPSNM 1

69 10H 1IC

.580 ZPUMB 2

69 10H liC

.580 ZPUMB 19 69 02H 02H

.610 ZPSNM 23 69 04H 04H

.610 ZPSNM 25 69 02H 02H

.610 ZPSNM 33 69 03H 03H

.610 ZPSNM 1

70 10H lIC

.580 ZPUMB B-14 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 2

70 10H 11C

.580 ZPUMB 8

70 01H 02H

.610 ZPSNM 42 70 17C 17C

.610 ZPSNM 1

71 10H 11C

.580 ZPUMB 2

71 10H 11C

.580 ZPUMB 15 71 02H 02H

.610 ZPSNM 16 71 02H 02H

.610 ZPSNM 18 71 03H 03H

.610 ZPSNM 23 71 02H 02H

.610 ZPSNM 24 71 04H 04H

.610 ZPSNM 37 71 02H 02H

.610 ZPSNM 42 71 02H 02H

.610 ZPSNM 48 71 16C 16C

.610 ZPSNM 1

72 10H 11C

.580 ZPUMB 2

72 10H 11C

.580 ZPUMB 16 72 04H 04H

.610 ZPSNM 23 72 02H 02H

.610 ZPSNM 25 72 02H 02H

.610 ZPSNM 25 72 04H 04H

.610 ZPSNM 41 72 02H 02H

.610 ZPSNM 43 72 01H 02H

.610 ZPSNM 46 72 12C 12C

.610 ZPSNM 47 72 21C 21C

.610 ZPSNM 47 72 22C 22C

.610 ZPSNM 1

73 10H 11C

.580 ZPUMB 2

73 10H 11C

.580 ZPUMB 14 73 02H 02H

.610 ZPSNM 24 73 02H 02H

.610 ZPSNM 46 73 10H 10H

.580 ZPUMB 1

74 10H 11C

.580 ZPUMB 2

74 10H 11C

.580 ZPUMB 41 74 02H 02H

.610 ZPSNM 43 74 11C 11C

.610 ZPSNM 1

75 10H 11C

.580 ZPUMB 2

75 10H 11C

.580 ZPUMB 15 75 03H 03H

.610 ZPSNM 18 75 02H 02H

.610 ZPSNM 28 75 110 11C

.580 ZPUMB 30 75 02H 02H

.610 ZPSNM 30 75 03H 03H

.610 ZPSNM 30 75 04H 04H

.610 ZPSNM 32 75 02H 02H

.610 ZPSNM B-15 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 48 75 21C 21C

.610 ZPSNM 48 75 22C 22C

.610 ZPSNM 1

76 10H 10H

.580 ZPUMB 1

76 10H 11C

.580 ZPUMB 2

76 10H 11C

.580 ZPUMB 8

76 01H 02H

.610 ZPSNM 25 76 02H 02H

.610 ZPSNM 29 76 02H 02H

.610 ZPSNM 29 76 03H 03H

.610 ZPSNM 43 76 22C 21C

.610 ZPSNM 47 76 21C 21C

.610 ZPSNM 47 76 22C 22C

.610 ZPSNM 48 76 21C 21C

.610 ZPSNM 48 76 22C 22C

.610 ZPSNM 1

77 10H 11C

.580 ZPUMB 2

77 10H 11C

.580 ZPUMB 19 77 03H 03H

.610 ZPSNM 20 77 17C 16C

.610 ZPSNM 47 77 21C 21C

.610 ZPSNM 47 77 22C 22C

.610 ZPSNM 1

78 10H 11C

.580 ZPUMB 2

78 10H 11C

.580 ZPUMB 11 78 TSC TSC

.610 ZPSNM 23 78 03H 03H

.610 ZPSNM 31 78 01H 02H

.610 ZPSNM 35 78 03H 03H

.610 ZPSNM 47 78 21C 21C

.610 ZPSNM 47 78 22C 22C

.610 ZPSNM 48 78 05H 05H

.610 ZPSNM 1

79 10H 11C

.580 ZPUMB 2

79 10H 11C

.580 ZPUMB 2

79 TSH 01H

.610 ZPSNM 25 79 04H 04H

.610 ZPSNM 1

80 10H 11C

.580 ZPUMB 2

80 10H 11C

.580 ZPUMB 10 80 15C 15C

.610 ZPSNM 17 80 03H 03H

.610 ZPSNM 1

81 10H 11C

.580 ZPUMB 2

81 10H 11C

.580 ZPUMB 14 81 110 11C

.580 ZPUMB 22 81 03H 03H

.610 ZPSNM 22 81 04H 04H

.610 ZPSNM B-16 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 26 81 03H 03H

.610 ZPSNM 38 81 03H 03H

.610 ZPSNM 1

82 10H 10H

.580 ZPUMB 1

82 10H 11C

.580 ZPUMB 2

82 10H 11C

.580 ZPUMB 16 82 10H 10H

.580 ZPUMB 16 82 11C 11C

.580 ZPUMB 35 82 17C 16C

.610 ZPSNM 46 82 01H 02H

.610 ZPSNM 47 82 19C 19C

.610 ZPSNM 1

83 05H 05H

.610 ZPSNM 1

83 10H 11C

.580 ZPUMB 2

83 10H 11C

.580 ZPUMB 4

83 22C 21C

.610 ZPSMB 20 83 02H 02H

.610 ZPSNM 20 83 03H 03H

.610 ZPSNM 28 83 21C 21C

.610 ZPSNM 43 83 02H 02H

.610 ZPSNM 44 83 02H 02H

.610 ZPSNM 47 83 11C 11C

.580 ZPUMB 48 83 17C 16C

.610 ZPSNM 1

84 1OH 11C

.580 ZPUMB 2

84 1OH 11C

.580 ZPUMB 28 84 04H 04H

.610 ZPSNM 34 84 05H 05H

.610 ZPSNM 48 84 21C 21C

.610 ZPSNM 48 84 22C 22C

.610 ZPSNM 1

85 10H 11C

.580 ZPUMB 1

85 11C 11C

.610 ZPSNM 2

85 10H 11C

.580 ZPUMB 4

85 14C 13C

.610 ZPSMB 13 85 20C 20C

.610 ZPSNM 19 85 03H 03H

.610 ZPSNM 21 85 03H 03H

.610 ZPSNM 26 85 02H 02H

.610 ZPSNM 42 85 02H 02H

.610 ZPSNM 43 85 02H 02H

.610 ZPSNM 47 85 11C 11C

.580 ZPUMB 1

86 10H 11C

.580 ZPUMB 2

86 10H 11C

.580 ZPUMB 28 86 15C 14C

.610 ZPSMB 29 86 02H 02H

.610 ZPSNM B-17 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 1

87 10H 11C

.580 ZPUMB 2

87 10H 11C

.580 ZPUMB 3

87 12C 11C

.610 ZPSMB 18 87 03H 03H

.610 ZPSNM 26 87 02H 03H

.610 ZPSNM 37 87 03H 03H

.610 ZPSNM 1

88 10H 11C

.580 ZPUMB 2

88 10H 11C

.580 ZPUMB 17 88 03H 03H

.610 ZPSNM 28 88 02H 02H

.610 ZPSNM 35 88 03H 03H

.610 ZPSNM 40 88 03H 03H

.610 ZPSNM 48 88 21C 21C

.610 ZPSNM 48 88 22C 22C

.610 ZPSNM 1

89 10H 11C

.580 ZPUMB 2

89 10H 11C

.580 ZPUMB 16 89 04H 04H

.610 ZPSNM 18 89 03H 03H

.610 ZPSNM 30 89 03H 03H

.610 ZPSNM 30 89 04H 04H

.610 ZPSNM 38 89 02H 02H

.610 ZPSNM 42 89 03H 03H

.610 ZPSNM 1

90 10H 11C

.580 ZPUMB 2

90 10H 11C

.580 ZPUMB 16 90 03H 03H

.610 ZPSNM 19 90 AV4 AV3

.580 ZPUNM 24 90 03H 03H

.610 ZPSNM 24 90 11C 11C

.610 ZPSNM 26 90 03H 03H

.610 ZPSNM 30 90 02H 02H

.610 ZPSNM 30 90 03H 03H

.610 ZPSNM 34 90 14C 13C

.610 ZPSNM 1

91 10H 11C

.580 ZPUMB 2

91 10H 11C

.580 ZPUMB 14 91 21C 21C

.610 ZPSNM 17 91 02H 02H

.610 ZPSNM 21 91 02H 02H

.610 ZPSNM 21 91 05H 05H

.610 ZPSNM 26 91 02H 02H

.610 ZPSNM 26 91 04H 04H

.610 ZPSNM 27 91 02H 02H

.610 ZPSNM 43 91 22C 22C

.610 ZPSNM B-18 Appendix B

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 48 91 21C 21C

.610 ZPSNM 48 91 22C 22C

.610 ZPSNM 1

92 10H 11C

.580 ZPUMB 2

92 10H 11lC

.580 ZPUMB 2

92 17C 16C

.610 ZPSNM 2

92 18C 18C

.610 ZPSNM 13 92 03H 03H

.610 ZPSNM 15 92 03H 03H

.610 ZPSNM 26 92 02H 02H

.610 ZPSNM 35 92 21C 21C

.610 ZPSNM 1

93 10H 11C

.580 ZPUMB 2

93 10H 11C

.580 ZPUMB 22 93 02H 02H

.610 ZPSNM 24 93 02H 02H

.610 ZPSNM 1

94 06H 07H

.610 ZPSNM 1

94 10H 11C

.580 ZPUMB 2

94 10H 11C

.580 ZPUMB 14 94 02H 02H

.610 ZPSNM 24 94 07H 08H

.610 ZPSNM 30 94 04H 04H

.610 ZPSNM 35 94 01H 02H

.610 ZPSNM 36 94 03H 03H

.610 ZPSNM 47 94 21C 21C

.610 ZPSNM 47 94 22C 22C

.610 ZPSNM 1

95 10H 11C

.580 ZPUMB 18 95 03H 03H

.610 ZPSNM 22 95 04H 04H

.610 ZPSNM 47 95 21C 21C

.610 ZPSNM 47 95 22C 22C

.610 ZPSNM 1

96 10H 11C

.580 ZPUMB 2

96 03H 04H

.610 ZPSNM 2

96 10H 11C

.580 ZPUMB 13 96 03H 03H

.610 ZPSNM 1

97 10H 11C

.580 ZPUMB 2

97 10H 11C

.580 ZPUMB 5

97 09H 10H

.610 ZPSNM 5

97 12C 11C

.610 ZPSNM 21 97 03H 03H

.610 ZPSNM 1

98 10H 11C

.580 ZPUMB 2

98 10H 11C

.580 ZPUMB 8

98 01H 02H

.610 ZPSNM 43 98 21C 20C

.610 ZPSNM B-19 Appendix B

Appendix B Tubes Examined By RPC at Locations Other than TSH S/G-D BEGIN TEST 10H 10H 01H 02H 03H 10H 101H 03H 03H 10H 10H 11C 09H ROW 1

2 8

18 19 1

2 17 26 1

2 10 11 41 1

2 16 21 24 40 41 1

2 12 13 19 20 32 1

2 23 25 1

2 11 17 21 1

2 13 13 28 END TEST lic lic 02H 02H 03H 11C lic 03H 03H 11C 11C 11C 10H 11C 110 110 02H 03H 03H 19C 13C 11C 11C 03H 02H 03H 03H 16C 11C 11C 02H 02H 11C 11C 16C 03H 03H 11C 11C 02H 19C 02H PROBE

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNIM

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.610 ZPSMB

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.610 ZPSNM B-20 COLUMN 99 99 99 99 99 100 100 100 100 101 101 101 101 11C 10H 10H 02H 03H 03H 19C 13C 10H 10H 03H 02H 03H 03H 17C 10H 10H 02H 02H 10H 10H 17C 03H 03H 10H 10H 02H 19C 02H 101 102 102 102 102 102 102 102 103 103 103 103 103 103 103 104 104 104 104 105 105 105 105 105 106 106 106 106 106

.A

Tubes Examined By RPC at Locations Other than TSH S/G-D ROW COLUMN BEGIN TEST END TEST PROBE 1

107 10H 11C

.580 ZPUMB 2

107 10H 11C

.580 ZPUMB 3

107 11C 11C

.580 ZPUMB 8

107 01H 02H

.610 ZPSNM 12 107 02H 02H

.610 ZPSNM 22 107 02H 02H

.610 ZPSNM 23 107 03H 04H

.610 ZPSNM 1

108 10H 11C

.580 ZPUMB 2

108 10H 11C

.580 ZPUMB 3

108 11C 11C

.580 ZPUMB 9

108 02H 02H

.610 ZPSNM 15 108 09H 09H

.610 ZPSNM 15 108 12C 11C

.610 ZPSNM 16 108 02H 02H

.610 ZPSNM 17 108 02H 02H

.610 ZPSNM 18 108 02H 02H

.610 ZPSNM 25 108 02H 02H

.610 ZPSNM 29 108 10H 10H

.610 ZPSNM 1

109 10H 11C

.580 ZPUMB 2

109 10H 11C

.580 ZPUMB 10 109 02H 02H

.610 ZPSNM 1

110 10H 11C

.580 ZPUMB 2

110 10H 11C

.580 ZPUMB 14 110 02H 02H

.610 ZPSNM 1

111 10H 11C

.580 ZPUMB 2

111 10H 11C

.580 ZPUMB 23 111 09H 09H

.610 ZPSNM 11C 10H 10H 08H 01H 10H 10H 10H 10H 10H 10H 10H 10H 11C 11C 11C 09H 02H 11C 11C 11C 11C 11C 1iC 11C 11C 11C 11C

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.580 ZPUMB

.580 ZPUMB

.610 ZPSNM

.580 ZPUMB

.580 ZPUMB

.580 ZPUMB

.580 ZPUMB

".580 ZPUMB Appendix B B-21 Z3 1

2 3

4 1

2 18 2

18 1

2 1

2 1

111 112 112 112 112 113 113 114 114 114 115 115 116 116 117

Tubes Examined By RPC at Locations Other than TSH S/G-D B-22 Appendix B ROW COLUMN BEGIN TEST END TEST PROBE 2

117 10H 11C

.580 ZPUMB 16 117 12C 12C

.610 ZPSNM 17 117 12C 12C

.610 ZPSNM 1

118 10H 1IC

.580 ZPUMB 2

118 10H I1C

.580 ZPUMB 1

119 10H 11C

.580 ZPUMB 2

119 10H 11C

.580 ZPUMB 1

120 10H 11C

.580 ZPUMB 2

120 10H 11C

.580 ZPUMB

APPENDIX C DENTS AND DINGS

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 6

1 DNG 02H 7.70 10 6

1 DNG 02H 13.54 10 6

1 DNG 02H 25.44 10 8

1 DNG 02H 24.27 10 8

1 DNG 02H 32.41 10 8

1 DNG TSH

.92 10 2

2 DNG 20C 9.39 12 3

2 DNG 03H 33.50 107 3

2 DNG 10H 12.24 107 4

2 DNG 20C 6.57 12 7

2 DNG 19C 8.19 12 7

2 DNG 20C 3.60 12 7

2 DNG 20C 6.54 12 7

2 DNG 20C 7.20 12 8

2 DNG 17C 6.63 10 8

2 DNG 18C 3.59 10 8

2 DNG 21C 1.07 10 8

2 DNG 21C 8.14 10 8

2 DNG 23C

.83 10 8

2 DNG 23C 7.91 10 9

2 DNG 04H 7.98 10 9

2 DNG 06H 40.14 10 11 2

DNG 02H 28.62 10 11 2

DNG 02H 29.78 10 13 2

DNG TSH

.80 10 2

3 DNG 02H 30.64 119 2

3 DNG 02H 30.77 107 2

3 DNG 09H 24.43 119 2

3 DNG 09H 24.93 107 2

3 DNG 09H 24.94 119 2

3 DNG 09H 25.34 107 6

3 DNG 14C 15.26 12 14 3

DNG 10H 49.32 10 15 3

DNG 02H 27.24 10 15 3

DNG 02H 28.21 10 15 3

DNG 02H 29.94 10 15 3

DNG 13C 41.71 10 16 3

DNG 02H 28.79 10 16 3

DNG 02H 29.94 10 14 4

DNG AV4 10.47 12 18 4

DNG AV1 15.68 12 19 4

DNG 10H 3.95 12 19 4

DNG 10H 4.70 12 19 4

DNG AV1 16.93 12 C-I Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 18 5

DNG 09H 38.79 10 20 5

DNG AV1 1.52 84 2

6 DNG 12C 16.60 36 4

6 DNG 02H 7.49 107 6

6 DNG 14C 20.84 32 13 6

DNG 12C 16.00 84 14 6

DNG AV4 9.97 84 21 6

DNG AV1 9.72 84 23 6

DNG 02H 28.20 84 24 6

DNG 02H 28.74 12 24 6

DNG 02H 29.10 12 24 6

DNG 02H 29.51 12 24 6

DNG 04H 2.84 12 24 6

DNG AV2 1.10 12 1

7 DNG 17C 6.29 36 1

7 DNT 16C

-.08 36 3

7 DNG 05H 38.83 107 3

7 DNG 06H 36.48 107 4

7 DNG 17C 24.34 34 7

7 DNG 08H 38.02 32 7

7 DNG 21C 8.26 32 11 7

DNG 21C 6.41 16 14 7

DNG 01H 24.97 16 14 7

DNG AV4 10.55 16 17 7

DNG 12C 8.23 16 18 7

DNG 17C 30.51 16 19 7

DNG 02H 25.97 16 6

8 DNG 06H 22.92 30 7

8 DNG 21C 15.01 30 18 8

DNG 09H 43.71 14 18 8

DNG 09H 44.30 14 18 8

DNT 10H

-.46 14 18 8

DNT 10H

.03 14 18 8

DNT 11C

.40 14 19 8

DNG 09H 41.50 14 19 8

DNG 16C 9.77 14 24 8

DNG AV1 6.06 14 26 8

DNG 09H 42.56 84 26 8

DNG 09H 44.58 84 26 8

DNT 11C

.44 84 6

9 DNG 09H 24.07 32 6

9 DNG TSH 3.28 32 13 9

DNG 06H 22.41 16 18 9

DNG 09H 43.20 16 C-2 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 18 9

DNG 09H 44.32 16 18 9

DNT 10H

.24 16 18 9

DNT 11C

.42 16 25 9

DNG 17C 31.46 16 28 9

DNG 13C 37.75 16 28 9

DNG 14C 23.86 16 28 9

DNG 22C 7.04 16 12 10 DNG 17C 28.92 14 14 10 DNG AV4 10.28 14 15 10 DNG 09H 41.50 14 15 10 DNG 17C 34.32 14 15 10 DNG 21C 12.06 14 20 10 DNG 10H 20.44 14 20 10 DNG AV1 4.25 14 20 10 DNG AV3 3.36 14 20 10 DNG AV4 11.44 14 27 10 DNG 15C 9.48 14 6

11 DNG 19C 6.81 32 12 11 DNG 03H 26.08 16 18 11 DNG 15C 3.74 16 18 11 DNG 16C 35.37 16 29 11 DNG 14C 21.07 16 9

12 DNG 02H 8.04 30 14 12 DNG 18C 9.07 14 19 12 DNG 02H 9.01 14 19 12 DNG 05H 33.76 14 19 12 DNG 09H 42.00 14 30 12 DNG 15C 11.77 14 30 12 DNG 15C 18.78 14 30 12 DNG 15C 25.65 14 30 12 DNG 15C 39.76 14 30 12 DNG 16C 36.32 14 8

13 DNG 18C 12.66 32 19 13 DNG 21C 14.97 16 22 13 DNG 20C 7.39 16 28 13 DNG 01H 1.34 16 28 13 DNG 08H 24.26 16 28 13 DNG 15C 14.64 16 28 13 DNG 19C 1.21 16 28 13 DNG 20C 7.36 16 29 13 DNG 23C 4.94 16 29 13 DNG 23C 5.38 16 29 13 DNG TSC 1.77 16 31 13 DNG 21C 4.61 26 C-3 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 33 13 DNG 15C 5.78 28 33 13 DNG 15C 12.43 28 33 13 DNG 15C 25.91 28 33 13 DNG 17C 19.46 28 35 13 DNG AV3 1.01 28 35 13 DNG AV3 2.73 28 35 13 DNG AV4 10.61 28 4

14 DNG 03H 2.20 109 4

14 DNG 10H 18.77 109 5

14 DNG 05H 42.04 107 5

14 DNG 09H 22.45 107 14 14 DNG AV4 8.99 14 19 14 DNG 01H 21.31 14 23 14 DNG 08H 36.14 14 24 14 DNG AV1 5.98 14 31 14 DNG 1OH 22.63 84 32 14 DNG 23C 7.15 84 34 14 DNG 22C 7.43 84 35 14 DNG 01H 19.86 84 6

15 DNG 17C 12.91 32 14 15 DNG AV4 9.17 16 17 15 DNG 13C 29.61 16 17 15 DNG 20C 12.94 16 17 15 DNG 20C 13.62 16 21 15 DNG 07H 20.20 16 29 15 DNG 01H 19.83 16 29 15 DNG 02H 6.25 16 29 15 DNG 02H 8.24 16 29 15 DNG 20C 11.69 16 29 15 DNG AV1 19.03 16 29 15 DNG TSC 3.03 16 31 15 DNG AVI 12.78 28 32 15 DNG AV4 19.66 28 4

16 DNG 21C 14.40 36 12 16 DNT 11C

-.36 14 14 16 DNG AV4 8.60 14 34 16 DNG 03H 3.37 26 38 16 DNG AV1 14.78 26 38 16 DNG AV1 16.11 26 39 16 DNG 12C 3.60 28 39 16 DNG 12C 10.31 28 39 16 DNG 13C 3.90 28 39 16 DNG 14C 4.21 28 39 16 DNG 15C 14.76 28 C4 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 2

17 DNG 08H 7.44 109 2

17 DNG 09H 24.09 109 10 17 DNG 17C 5.72 32 20 17 DNG 01H 12.57 16 20 17 DNG 02H 8.93 16 20 17 DNG 02H 14.91 16 24 17 DNG AVI 6.64 16 29 17 DNG 19C 11.55 16 29 17 DNG 20C 1.76 16 29 17 DNG 20C 8.85 16 29 17 DNG 20C 15.68 16 29 17 DNG 21C 5.30 16 29 17 DNG 21C 5.83 16 29 17 DNG 21C 12.82 16 29 17 DNG 22C 3.00 16 29 17 DNG 22C 9.92 16 29 17 DNG 22C 16.93 16 29 17 DNG 23C 6.22 16 29 17 DNG TSC 1.57 16 29 17 DNG TSC 8.61 16 35 17 DNG 08H 37.69 26 35 17 DNG 22C 6.56 26 37 17 DNG 02H 9.99 26 39 17 DNG 12C 42.50 26 39 17 DNG 14C 41.86 26 2

18 DNG 06H 22.30 109 9

18 DNG 09H 32.34 30 9

18 DNG 09H 33.37 30 9

18 DNG 09H 34.49 30 9

18 DNG 09H 35.75 30 9

18 DNG 12C 35.67 30 18 18 DNG 01H 8.85 14 18 18 DNG 05H 21.64 14 27 18 DNG 15C 2.86 14 27 18 DNG 15C 12.14 14 27 18 DNG 15C 14.71 14 27 18 DNG 15C 17.54 14 27 18 DNG 15C 24.91 14 27 18 DNG 16C 37.75 14 27 18 DNG 16C 39.74 14 27 18 DNG 16C 41.70 14 31 18 DNG 08H 13.91 28 35 18 DNG 08H 41.06 28 39 18 DNG 08H 34.15 28 C-5 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 39 18 DNG 14C 39.35 28 3

19 DNG 02H 9.16 107 3

19 DNG 03H 28.26 107 3

19 DNG 03H 34.51 107 3

19 DNG 05H 1.79 107 3

19 DNG 05H 7.98 107 6

19 DNG 15C 13.77 32 1

20 DNG 16C 12.68 36 2

20 DNG 17C 43.36 36 5

20 DNG 22C 6.08 36 22 20 DNG 17C 41.47 14 30 20 DNG 08H 15.31 14 30 20 DNG 08H 22.26 14 30 20 DNG 08H 29.28 14 4

21 DNG 03H 30.65 109 7

21 DNG 02H 23.10 32 8

21 DNG AV4 9.68 32 17 21 DNG 18C 5.14 16 17 21 DNG 19C 13.81 16 24 21 DNG AV1 7.50 16 28 21 DNG 17C 31.46 16 30 21 DNG 22C 11.15 16 32 21 DNG AV4 19.46 26 34 21 DNG 12C 39.68 26 34 21 DNT 11C

.43 26 35 21 DNG 08H 38.29 84 35 21 DNG 14C 16.76 84 38 21 DNG 13C

.98 84 39 21 DNG 17C 15.18 84 42 21 DNT 10H

.48 26 5

22 DNG 06H 14.62 107 6

22 DNG 01H 12.16 32 6

22 DNG 17C 20.65 32 6

22 DNG 17C 21.82 32 6

22 DNG 17C 33.20 32 8

22 DNG 16C 25.54 30 15 22 DNG 01H 13.72 14 16 22 DNG 19C 16.97 14 17 22 DNG 08H 22.49 14 20 22 DNG 22C 10.17 14 20 22 DNG 22C 15.07 14 28 22 DNG 02H 3.93 14 29 22 DNG 14C 32.44 14 30 22 DNG 13C 2.39 14 C-6 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 31 22 DNG 01H 3.74 28 31 22 DNG 01H 10.84 28 31 22 DNG 02H 3.71 28 31 22 DNG 22C 7.80 28 31 22 DNG TSH 6.45 28 32 22 DNG 15C 18.64 28 44 22 DNG 23C

.81 28 44 22 DNG AV2 18.82 28 7

23 DNG 03H 26.25 32 14 23 DNG 01H 24.47 16 18 23 DNG AVI 4.42 16 25 23 DNG 21C 12.50 16 30 23 DNG 15C 19.42 16 35 23 DNG 17C 30.27 26 36 23 DNG 20C 1.29 26 36 23 DNG 23C 6.10 26 36 23 DNG TSC 8.58 26 38 23 DNG 21C 5.90 26 39 23 DNG 22C 6.05 26 39 23 DNT 22C

-.25 26 43 23 DNG AV4 32.10 26 5

24 DNG 17C 22.07 36 18 24 DNG 01H 7.94 14 18 24 DNG 14C 41.46 14 18 24 DNG 14C 41.76 14 31 24 DNG 17C 36.27 26 37 24 DNG 03H 12.08 28 37 24 DNG 06H 35.73 28 43 24 DNT 10H

.54 28 46 24 DNG 10H 2.86 28 8

25 DNG AV4 8.54 32 9

25 DNG AVI 1.49 32 13 25 DNG 23C 3.96 16 24 25 DNG AV1 7.74 16 25 25 DNG AV4 21.66 16 26 25 DNG 13C 40.66 16 27 25 DNG 22C 2.87 20 29 25 DNG 12C 10.13 20 29 25 DNG 12C 11.20 20 31 25 DNG 17C 34.72 26 32 25 DNG 12C 3.04 26 32 25 DNT 10H

.53 26 33 25 DNG 12C 17.50 26 33 25 DNG 12C 18.69 26 C-7 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 33 25 DNT 10H

.55 26 42 25 DNG 01H 15.23 26 42 25 DNG 01H 15.82 26 42 25 DNG 10H 3.65 26 42 25 DNG 19C 15.75 26 42 25 DNG 19C 16.99 26 43 25 DNT 10H

.54 26 1

26 DNT liC

.76 40 4

26 DNG 10H 9.36 109 4

26 DNG 10H 16.81 109 9

26 DNG AV1 1.44 38 16 26 DNG AV4 4.69 14 27 26 DNG 17C 33.49 14 31 26 DNG 16C 37.07 26 32 26 DNG 03H 8.03 28 32 26 DNG 03H 9.66 28 32 26 DNG 03H 21.24 28 32 26 DNG 03H 23.17 28 45 26 DNG 10H 5.84 28 2

27 DNG 03H 19.48 109 4

27 DNG 10H 13.02 109 5

27 DNG 06H 26.11 107 9

27 DNG AVI 1.10 40 13 27 DNG 01H

.94 20 13 27 DNG 01H 7.03 20 13 27 DNG 01H 13.10 20 13 27 DNG TSH 4.25 20 14 27 DNG AV4 6.60 20 18 27 DNT 10H

.49 20 19 27 DNG 09H 43.65 20 19 27 DNG 12C 40.10 20 28 27 DNG 10H 14.91 20 29 27 DNG 09H 5.13 20 30 27 DNT 10H

.55 20 34 27 DNG 08H 20.68 26 36 27 DNG 01H 7.76 26 37 27 DNG 17C 11.69 26 42 27 DNG 10H 3.72 26 43 27 DNG 12C 15.47 26 43 27 DNG 12C 36.26 26 46 27 DNG 03H 21.69 26 48 27 DNG 05H 1.19 26 48 27 DNG AV3 29.34 26 48 27 DNG TSC

.68 26 C-8 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 2

28 DNG 02H 34.21 109 4

28 DNG 10H 9.16 109 6

28 DNG 04H 31.05 38 7

28 DNG 22C 12.34 38 8

28 DNG TSC 4.66 38 9

28 DNG AV1 1.02 38 14 28 DNG AV4 6.05 18 16 28 DNG 04H 1.06 18 24 28 DNG AVi 7.74 18 29 28 DNG 19C 10.99 18 31 28 DNG 01H 24.06 24 31 28 DNG 01H 24.07 84 31 28 DNG 05H 44.41 84 31 28 DNG 05H 44.47 24 31 28 DNG 06H 5.94 24 31 28 DNG 06H 5.95 84 31 28 DNG 10H 3.09 24 31 28 DNG 13C 30.86 24 31 28 DNG 13C 31.20 84 40 28 DNG 01H 3.23 24 40 28 DNG 16C 2.49 24 40 28 DNG 17C 14.74 24 40 28 DNG TSH 5.71 24 41 28 DNG 07H 4.20 24 42 28 DNG 10H 3.77 24 43 28 DNG 21C 3.57 24 43 28 DNT 10H

.54 24 47 28 DNG AV3 29.12 24 8

29 DNG 07H 39.21 40 9

29 DNG AV1 1.04 40 14 29 DNG 10H 10.76 20 16 29 DNG 10H 8.27 20 16 29 DNG AVi 2.93 20 24 29 DNG AV1 7.31 20 27 29 DNG 01H 18.55 20 29 29 DNG 03H 10.22 20 31 29 DNG 16C 40.83 22 34 29 DNG AV4 16.15 22 42 29 DNG 12C 41.75 22 42 29 DNG 17C 16.00 22 47 29 DNG AV3 29.16 22 48 29 DNG 01H 18.47 22 8

30 DNG 01H 4.84 38 16 30 DNG 10H 8.47 18 C-9 Appendix C

Appendix C Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 29 30 DNG 17C 12.26 18 29 30 DNG 17C 21.85 18 30 30 DNG TSC 3.54 18 33 30 DNG 12C 8.13 24 42 30 DNG 1OH 3.85 24 42 30 DNG 12C 41.64 24 43 30 DNG 19C 10.56 24 2

31 DNG 07H 17.85 113 7

31 DNG 15C 7.56 40 7

31 DNG 15C 19.89 40 7

31 DNG 15C 25.86 40 7

31 DNG 16C 34.70 40 7

31 DNG 16C 40.48 40 8

31 DNG 10H 3.34 40 12 31 DNG TSH 1.06 20 14 31 DNG AV4 6.19 20 25 31 DNG 08H 33.01 20 31 31 DNG 02H 28.19 22 31 31 DNG 03H 27.57 22 31 31 DNG 04H 19.62 22 31 31 DNG 04H 26.72 22 31 31 DNG 04H 40.51 22 31 31 DNG 05H 2.17 22 31 31 DNG 05H 9.00 22 31 31 DNG 05H 23.15 22 31 31 DNG 05H 37.06 22 31 31 DNG 06H 40.51 22 31 31 DNG 18C 4.57 22 31 31 DNG 20C 10.73 22 5

32 DNG 22C 1.93 40 7

32 DNG 14C 37.79 38 7

32 DNG 14C 38.62 38 7

32 DNG 16C 34.03 38 7

32 DNG 18C 4.69 38 15 32 DNG TSH 8.03 18 19 32 DNG 08H 28.11 18 19 32 DNG 08H 35.00 18 19 32 DNG 09H 31.73 18 19 32 DNG 09H 38.34 18 19 32 DNT 10H

-.50 18 19 32 DNT 22C

-.31 18 20 32 DNG 07H 29.95 18 28 32 DNG 21C 15.86 18 30 32 DNG 20C 10.66 18 C-I0

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 46 32 DNT 04H

-.22 24 6

33 DNG 05H 3.71 40 6

33 DNG 06H 18.86 40 6

33 DNG 15C 17.37 40 10 33 DNG 15C 23.05 40 10 33 DNG 16C 9.21 40 18 33 DNG 20C 5.80 20 18 33 DNG 21C 16.64 20 23 33 DNG 04H 34.44 20 28 33 DNG 14C 16.96 20 30 33 DNG 08H 29.61 20 39 33 DNG 19C 9.96 22 39 33 DNG 19C 10.93 22 39 33 DNG 19C 12.55 22 42 33 DNG 12C 41.66 22 42 33 DNG AV4 31.67 22 43 33 DNG 22C 15.13 22 47 33 DNG 02H 19.51 22 47 33 DNG 22C 16.92 22 8

34 DNG 13C 32.83 38 12 34 DNG 05H 15.24 18 13 34 DNG 06H 8.67 18 20 34 DNG 12C 43.50 18 42 34 DNG 09H 41.50 24 42 34 DNG 10H 1.23 24 42 34 DNG 17C 22.83 24 45 34 DNG 01H 26.21 24 48 34 DNG 02H 16.07 24 4

35 DNG 02H 18.60 107 6

35 DNG 07H 37.57 40 10 35 DNG 09H 25.58 40 10 35 DNG 09H 26.55 40 10 35 DNG 12C 27.58 40 11 35 DNG 17C 5.11 20 26 35 DNG 21C 5.87 20 26 35 DNG 22C 7.38 20 27 35 DNG 17C 2.04 20 28 35 DNG 17C 37.29 20 29 35 DNG 18C 2.23 20 29 35 DNG 19C 3.85 20 29 35 DNG 19C 6.50 20 29 35 DNG 19C 11.33 20 29 35 DNG 19C 13.98 20 29 35 DNG 19C 16.34 20 C-1I Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 29 35 DNG 21C 7.33 20 29 35 DNG 21C 8.60 20 29 35 DNG 21C 9.61 20 29 35 DNG 21C 14.32 20 32 35 DNG 14C 26.46 24 42 35 DNG AV4 30.71 22 4

36 DNG 09H 26.44 107 4

36 DNG 09H 41.99 107 10 36 DNG 06H 23.92 38 17 36 DNG 15C 1.59 18 17 36 DNG 17C 11.52 18 17 36 DNG 17C 12.32 18 40 36 DNG 07H 35.80 24 42 36 DNG 12C 42.02 24 42 36 DNG 20C 4.59 24 42 36 DNG AV4 29.81 24 43 36 DNG 04H 38.05 24 10 37 DNG 05H 29.92 40 10 37 DNG 13C 17.73 40 10 37 DNG 13C 32.85 40 10 37 DNG 14C 2.66 40 10 37 DNG 14C 33.15 40 13 37 DNG 12C 14.30 20 13 37 DNG 15C 12.84 20 13 37 DNT 20C

.47 20 13 37 DNT 22C

-.06 20 15 37 DNG 12C 35.41 20 18 37 DNG 03H 21.41 20 18 37 DNG 03H 22.40 20 20 37 DNG 07H 43.17 20 24 37 DNG 16C 11.88 20 35 37 DNG 08H 27.14 22 37 37 DNG 01H 6.39 22 42 37 DNG 12C 41.71 22 42 37 DNG AV4 31.00 22 47 37 DNG AV3 29.72 22 3

38 DNG 13C 8.51 40 4

38 DNT 16C

.00 40 9

38 DNG 01H 19.11 38 11 38 DNG 09H 30.85 18 12 38 DNG 06H 28.17 18 18 38 DNG AV1 6.38 18 23 38 DNG 22C 6.80 18 32 38 DNG 14C 33.51 28 C-12 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 32 38 DNG 16C 3.30 28 32 38 DNG 16C 3.97 28 32 38 DNG 18C 5.66 28 36 38 DNG 17C 9.85 28 40 38 DNG 22C 4.05 28 40 38 DNG TSC 4.70 28 40 38 DNG TSC 5.89 28 42 38 DNG 12C 41.41 28 42 38 DNG AV4 31.18 28 47 38 DNG 06H 4.88 28 47 38 DNG 20C 3.62 28 24 39 DNG 03H 33.30 20 28 39 DNG 09H 28.86 20 33 39 DNG 19C 5.04 26 39 39 DNG 22C 5.17 26 42 39 DNG 12C 41.84 26 42 39 DNG AV4 31.03 26 44 39 DNG 17C 10.51 26 44 39 DNG 20C 5.50 26 46 39 DNG AV4 26.02 26 47 39 DNG AV3 30.08 26 48 39 DNG 21C 7.53 26 6

40 DNG 12C 16.34 38 19 40 DNG AV2 3.23 18 23 40 DNG 07H 4.98 18 30 40 DNG 06H 19.89 18 31 40 DNG 19C 8.94 28 33 40 DNG 21C 13.31 28 37 40 DNT 11C

.37 28 40 40 DNG 06H 4.63 42 41 40 DNG 06H 39.95 42 42 40 DNG 12C 20.97 42 47 40 DNG 16C 10.66 32 3

41 DNG 10H 13.44 111 4

41 DNG 10H 14.73 107 10 41 DNG 19C 3.23 86 15 41 DNG 05H 25.28 20 21 41 DNG 04H 2.93 20 27 41 DNT 10H

.48 20 30 41 DNG 15C 35.28 20 35 41 DNG 05H 39.15 26 35 41 DNG 21C 2.76 26 39 41 DNG 06H 9.21 26 41 41 DNG 23C 4.17 44 C-13 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 4

42 DNG 10H 18.30 107 8

42 DNG 09H 29.21 46 8

42 DNG 09H 30.26 46 8

42 DNG 09H 39.82 46 8

42 DNG 09H 41.36 46 8

42 DNG 09H 42.43 46 8

42 DNG 09H 44.00 46 8

42 DNG 11C 1.14 46 8

42 DNG 12C 17.90 46 8

42 DNG 12C 29.95 46 8

42 DNG 12C 42.25 46 8

42 DNG 12C 43.95 46 8

42 DNG 15C 7.25 46 8

42 DNT 11C

.41 46 14 42 DNG 15C 28.10 18 16 42 DNG AV1 18.89 102 16 42 DNG AVi 19.45 96 16 42 DNG AV1 19.59 18 16 42 DNG AVI 19.62 88 16 42 DNG AV1 19.63 92 20 42 DNG 09H 18.81 18 20 42 DNG 09H 19.36 18 44 42 DNT 19C

.11 42 48 42 DNG 05H 11.13 84 4

43 DNG 16C 24.79 38 6

43 DNG 10H 8.81 48 20 43 DNG TSH 16.90 24 31 43 DNG 05H 1.62 42 32 43 DNT 17C

.46 42 32 43 DNT 22C

-.17 42 36 43 DNG 03H 21.54 42 43 43 DNG 19C 5.49 42 46 43 DNG 05H 22.05 42 46 43 DNG 05H 26.19 42 46 43 DNG 05H 30.89 42 2

44 DNG 16C 12.74 40 3

44 DNG 01H 2.44 111 10 44 DNG 06H 2.15 46 15 44 DNG 05H 4.89 22 17 44 DNG 18C 8.29 22 19 44 DNG 09H 36.77 22 26 44 DNG 02H 21.22 22 27 44 DNG 18C 2.18 22 33 44 DNG 21C 7.83 86 C-14 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 40 44 DNG 12C 12.88 44 44 44 DNG 01H 2.02 44 44 44 DNG TSH 1.64 44 44 44 DNG TSH 3.67 44 44 44 DNG TSH 5.32 44 44 44 DNG TSH 6.87 44 44 44 DNG TSH 8.27 44 8

45 DNG AV1

.56 48 12 45 DNG 21C 4.77 24 35 45 DNG 12C 16.83 42 35 45 DNG 13C 34.56 42 39 45 DNG 12C 2.54 42 46 45 DNG 01H 3.61 42 2

46 DNG 04H 37.74 109 2

46 DNG 05H 4.03 109 2

46 DNG 05H 15.76 109 2

46 DNG 05H 21.70 109 2

46 DNG 05H 27.52 109 2

46 DNG 05H 39.19 109 13 46 DNG 06H 28.99 22 13 46 DNG 06H 35.53 22 13 46 DNG 06H 41.65 22 13 46 DNG 07H 2.28 22 13 46 DNG 07H 8.30 22 13 46 DNG 07H 14.41 22 13 46 DNG 07H 20.51 22 13 46 DNG 08H 23.24 22 13 46 DNG 08H 29.57 22 28 46 DNG 17C 1.70 22 28 46 DNG 17C 2.63 22 28 46 DNG 17C 3.41 22 28 46 DNG 17C 3.94 22 28 46 DNG 17C 7.13 22 28 46 DNG 17C 7.69 22 28 46 DNG 18C 6.19 22 28 46 DNG 18C 10.74 22 28 46 DNG 18C 13.42 22 28 46 DNG 18C 16.82 22 28 46 DNG 19C 4.51 22 28 46 DNG 19C 5.10 22 30 46 DNG 03H 31.30 22 30 46 DNG 09H 24.73 22 30 46 DNG 09H 26.72 22 30 46 DNG 10H 10.47 22 C-15 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 41 46 DNG 03H 23.13 48 44 46 DNG 02H 34.10 48 46 46 DNG 08H 6.01 48 47 46 DNG 04H 11.12 48 1

47 DNG TSC 1.15 40 1

47 DNG TSC 7.44 40 10 47 DNG 04H 14.04 48 10 47 DNG 04H 20.17 48 10 47 DNG 04H 24.05 48 10 47 DNG 04H 26.16 48 10 47 DNG 04H 29.77 48 10 47 DNG 16C 5.37 48 10 47 DNG 17C 2.66 48 10 47 DNG 19C 1.97 48 10 47 DNG 19C 8.28 48 14 47 DNG 04H 34.10 24 14 47 DNG 04H 37.43 24 14 47 DNG 04H 39.55 24 14 47 DNG 05H 4.72 24 22 47 DNG 10H 3.00 24 22 47 DNG 10H 3.05 86 26 47 DNG 15C 12.84 24 37 47 DNG 04H 7.80 46 37 47 DNG 04H 17.02 46 46 47 DNG TSH 7.53 46 8

48 DNG 08H 17.84 46 8

48 DNG 08H 26.36 46 8

48 DNG 08H 29.05 46 11 48 DNG TSC 5.27 22 12 48 DNG 20C 7.39 22 19 48 DNG 23C 1.83 22 21 48 DNG 17C 14.12 22 21 48 DNG 17C 21.08 22 21 48 DNG 17C 24.03 22 21 48 DNG 17C 24.42 22 21 48 DNG 17C 25.82 22 21 48 DNG 17C 27.54 22 21 48 DNG 17C 29.81 22 21 48 DNG 17C 31.52 22 21 48 DNG 17C 32.08 22 21 48 DNG 17C 33.65 22 21 48 DNG 17C 35.59 22 21 48 DNG 17C 37.36 22 21 48 DNG 17C 39.52 22 C-I6 Appendix C

Dents and Dings S/G -A ROW COLUMN INDICATION LOCATION CAL NUMBER 21 48 DNG 17C 40.22 22 21 48 DNG 17C 43.03 22 22 48 DNG 09H 16.88 22 28 48 DNG 04H 21.05 22 28 48 DNG 04H 35.05 22 28 48 DNG 05H 30.74 22 29 48 DNG 22C 8.47 22 32 48 DNG 08H 40.05 48 41 48 DNG 03H 21.32 48 48 48 DNG AV1 3.95 48 1

49 DNG 19C 8.35 40 5

49 DNG 23C 6.47 38 14 49 DNG 22C 6.46 46 26 49 DNG 23C 2.70 46 29 49 DNG 03H 31.58 46 42 49 DNG 16C 5.51 46 44 49 DNG 20C 8.85 46 2

50 DNG 17C

.88 40 2

50 DNG 18C 3.77 40 2

50 DNG 18C 4.43 40 2

50 DNG 18C 5.57 40 2

50 DNG 18C 6.06 40 2

50 DNG 18C 7.11 40 2

50 DNG 18C 11.17 40 2

50 DNG 19C 12.77 40 7

50 DNG 01H 5.88 50 7

50 DNG 14C 27.21 50 30 50 DNG 13C 28.79 6

30 50 DNG 17C

.71 6

34 50 DNG 23C 6.33 6

34 50 DNG AV2 20.07 6

37 50 DNG 18C 6.51 6

37 50 DNG 18C 6.99 6

39 50 DNG 06H 5.51 6

2 51 DNG 21C 7.06 50 4

51 DNG 17C 38.29 50 8

51 DNG 01H 8.54 52 11 51 DNG 22C 16.32 46 17 51 DNG 04H 2.83 46 30 51 DNG 15C 4.94 8

34 51 DNG 08H 6.38 8

37 51 DNG 12C 7.52 8

37 51 DNG 12C 36.80 8

48 51 DNT 10H

.24 10 C-17 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 14 52 DNG 20C 1.65 48 30 52 DNG 03H 4.71 6

42 52 DNG 15C 12.28 6

1 53 DNG 12C 44.15 50 10 53 DNG 06H 9.65 92 12 53 DNG AV1 11.43 92 12 53 DNG AV1 16.84 92 23 53 DNG 12C 14.61 46 23 53 DNG 13C 41.75 46 25 53 DNG 02H 13.25 46 28 53 DNG 10H 14.90 46 29 53 DNG 07H 30.53 46 29 53 DNT 07H

.26 46 29 53 DNT 09H

-.09 46 29 53 DNT 11C

.18 46 29 53 DNT 23C

-.43 46 31 53 DNT 10H

.15 8

32 53 DNG 12C 22.00 8

32 53 DNG 15C 4.52 8

32 53 DNG 17C 34.37 8

32 53 DNG 21C 7.06 8

34 53 DNG 03H 27.04 8

42 53 DNG 03H 27.76 8

42 53 DNG 04H 20.24 8

43 53 DNG 17C 9.09 8

48 53 DNG 20C 7.07 10 4

54 DNG 05H 9.59 107 10 54 DNG 09H 14.13 92 10 54 DNG 09H 16.25 92 10 54 DNG 09H 37.31 92 10 54 DNG 10H

-.76 92 10 54 DNG 10H 1.41 92 10 54 DNG 12C 38.05 92 10 54 DNG 12C 44.50 92 10 54 DNT 10H

-.25 92 10 54 DNT 10H

.46 92 14 54 DNG AV4 6.67 52 15 54 DNG 10H 8.42 52 15 54 DNG AV1 10.14 52 15 54 DNG AV1 10.97 52 15 54 DNG AV4 4.57 52 15 54 DNG AV4 11.66 52 15 54 DNT 13C

-.23 52 15 54 DNT 15C

-.25 52 C-18 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 16 54 DNG 20C 9.42 52 19 54 DNG TSH 2.83 48 24 54 DNG 08H 24.80 48 27 54 DNG 04H 4.80 48 33 54 DNG 22C 3.22 6

36 54 DNG 05H 42.34 6

36 54 DNG 05H 43.71 6

36 54 DNG 06H

-.89 6

36 54 DNG 09H 12.88 6

36 54 DNG 17C 29.23 6

36 54 DNG 17C 30.49 6

36 54 DNG 17C 31.03 6

36 54 DNG 17C 31.51 6

36 54 DNG 21C 4.71 6

38 54 DNG 06H 11.23 6

38 54 DNG 06H 11.85 6

40 54 DNG AV2 2.47 6

48 54 DNG 07H 28.45 10 5

55 DNG 17C 15.58 50 10 55 DNG 09H 39.37 92 10 55 DNG 12C 39.93 92 10 55 DNG 12C 44.49 92 29 55 DNG 09H 36.21 46 30 55 DNG 18C 12.68 8

32 55 DNG 08H 23.16 8

9 56 DNG 04H 11.72 96 9

56 DNG 04H 11.77 92 14 56 DNG AV4 6.53 52 20 56 DNG 15C 41.23 52 20 56 DNG 17C 39.68 52 24 56 DNG AV3 6.56 48 27 56 DNG AV3 18.92 48 30 56 DNG 22C 2.66 6

30 56 DNG AV2 11.00 6

34 56 DNG 03H 7.82 6

34 56 DNG AV2 3.39 6

48 56 DNG AV4 27.57 10 2

57 DNG 20C 3.66 52 2

57 DNG 22C 8.63 52 4

57 DNG 12C 43.05 52 4

57 DNG 12C 43.86 52 6

57 DNG 14C 44.00 96 6

57 DNG 16C 25.25 96 7

57 DNG 12C 40.44 96 C-19 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 7

57 DNG 12C 41.05 98 9

57 DNG 04H 16.22 96 9

57 DNG 04H 16.38 92 10 57 DNG 08H 1.95 96 10 57 DNG 08H 2.02 92 11 57 DNG 1OH 6.36 92 11 57 DNG 10H 6.71 96 18 57 DNG 17C

.89 50 24 57 DNG 17C 1.84 48 40 57 DNG AV2 2.67 8

42 57 DNG 22C 16.28 8

43 57 DNG 21C 3.88 8

43 57 DNG 21C 5.43 8

48 57 DNG AV4 26.64 10 1

58 DNG 03H 6.78 111 17 58 DNG AVI 27.97 52 24 58 DNG 03H 27.37 46 32 58 DNG 01H 26.16 6

32 58 DNG 03H 12.39 6

34 58 DNG 19C 11.38 6

36 58 DNG 18C 13.40 6

40 58 DNG 09H 43.52 6

40 58 DNG AV2 2.58 6

42 58 DNG 16C 26.88 6

42 58 DNG TSC 2.62 6

43 58 DNG 08H 40.15 6

45 58 DNG 23C 4.53 6

47 58 DNG 14C 7.32 6

47 58 DNG 14C 14.22 6

47 58 DNG 14C 21.24 6

48 58 DNG 09H 44.55 10 48 58 DNG AV4 26.89 10 6

59 DNG AV1 3.42 96 7

59 DNG 17C 18.95 98 7

59 DNG 17C 19.02 96 10 59 DNG 12C 42.27 96 18 59 DNG AV3 9.94 50 19 59 DNG 02H 29.64 50 19 59 DNG 21C 4.69 50 19 59 DNG 21C 7.23 50 19 59 DNG 21C 8.00 50 19 59 DNG TSH 6.13 50 19 59 DNG TSH 12.34 50 19 59 DNG TSH 18.50 50 C-20 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 19 59 DNG TSH 24.51 50 19 59 DNG TSH 29.64 50 19 59 DNG TSH 31.84 50 19 59 DNG TSH 32.12 50 25 59 DNG 04H 18.65 48 25 59 DNG 18C 14.26 48 26 59 DNG 10H 8.70 48 26 59 DNG 12C 15.33 48 27 59 DNG TSH 30.43 48 30 59 DNG 02H 22.88 8

38 59 DNG 02H 29.20 8

38 59 DNG 09H 43.57 8

38 59 DNG 12C 23.90 8

42 59 DNG 12C 41.88 8

42 59 DNG AV4 29.58 8

4 60 DNG 12C 22.03 52 11 60 DNG 06H 43.42 96 18 60 DNG 10H 17.09 52 18 60 DNG AV3 10.47 52 19 60 DNG 22C 8.83 50 20 60 DNG 03H 34.41 52 20 60 DNG 04H 20.54 52 20 60 DNG 04H 23.98 52 20 60 DNG 21C 7.86 52 20 60 DNG TSC 7.23 52 20 60 DNG TSC 7.48 52 20 60 DNG TSH 4.64 52 11 61 DNG 04H 5.97 104 11 61 DNG 04H 7.22 104 19 61 DNG 10H 5.86 74 19 61 DNG AV2 4.45 74 19 61 DNG AV4 15.00 74 19 61 DNG AV4 15.90 74 19 61 DNG AV4 16.54 74 20 61 DNG 08H 44.35 52 20 61 DNG 18C 1.28 52 20 61 DNG 21C 7.45 52 3

62 DNG 04H 37.29 113 3

62 DNG 19C 3.01 104 5

62 DNG 12C 42.69 104 5

62 DNG 12C 43.38 104 5

62 DNG 12C 44.76 104 5

62 DNT 11C

-.03 104 5

62 DNT 11C

.03 117 C-21 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 6

62 DNG 12C 33.28 104 7

62 DNG 12C 44.55 104 7

62 DNG 18C 12.68 104 8

62 DNG 01H 1.94 104 10 62 DNG 01H 10.22 104 10 62 DNG 13C 4.32 104 10 62 DNG 13C 5.24 104 12 62 DNG 20C 2.13 104 12 62 DNG 20C 16.26 104 12 62 DNG TSC 8.66 104 19 62 DNG 04H 37.01 76 19 62 DNG 04H 38.00 76 19 62 DNG 05H 39.94 76 19 62 DNG 05H 40.05 76 19 62 DNG 05H 40.53 76 19 62 DNG 10H 6.06 76 19 62 DNG AV4 15.85 76 19 62 DNG AV4 16.60 76 20 62 DNG 21C 7.70 74 20 62 DNT 09H

-.06 74 20 62 DNT 10H

-.43 74 25 62 DNG 16C 40.80 50 28 62 DNG 16C 1.27 50 30 62 DNG 04H 30.05 6

33 62 DNG 18C 15.13 6

33 62 DNG 19C 11.24 6

38 62 DNG 01H 21.44 6

41 62 DNG 03H 12.31 6

42 62 DNG 12C 41.65 6

3 63 DNG 13C 9.83 104 6

63 DNG 12C 25.09 104 6

63 DNT 1IC

-.11 104 12 63 DNG 12C 6.09 104 16 63 DNG 03H 1.91 74 19 63 DNG 06H 7.78 76 19 63 DNG 06H 25.65 76 19 63 DNG 06H 43.55 76 19 63 DNG AV4 14.63 76 19 63 DNG AV4 15.84 76 29 63 DNG AV3 15.22 52 30 63 DNG 02H 16.12 8

30 63 DNG 02H 17.32 8

33 63 DNG 15C 25.89 8

34 63 DNG 05H 32.13 8

C-22 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 37 63 DNG 19C 4.50 8

42 63 DNG 12C 41.79 6

42 63 DNG AV4 30.33 6

4 64 DNG 06H 26.95 111 9

64 DNG 22C 3.77 104 9

64 DNG 22C 9.80 104 9

64 DNG 23C 1.77 104 9

64 DNG 23C 7.75 104 9

64 DNG TSC 4.87 104 23 64 DNG 14C 2.86 50 30 64 DNG 10H 9.50 8

30 64 DNG 17C 15.67 8

30 64 DNG 17C 19.85 8

30 64 DNG 17C 23.23 8

32 64 DNG AVl 4.99 8

32 64 DNG AV4 2.65 8

33 64 DNG 08H 30.96 6

33 64 DNG 16C 36.97 6

42 64 DNG 18C 11.19 8

44 64 DNG 03H 6.03 8

5 65 DNG 12C 40.91 104 5

65 DNG 12C 42.95 104 5

65 DNG 12C 43.35 104 5

65 DNG 12C 44.55 104 5

65 DNT 11C

.56 117 7

65 DNT 11C

.33 104 11 65 DNG 04H 30.75 104 12 65 DNG AV4 15.00 104 16 65 DNG TSC 6.41 74 26 65 DNG 09H 39.66 52 26 65 DNG 09H 40.73 52 26 65 DNG 12C 39.57 52 26 65 DNG 12c 40.44 52 26 65 DNG 12C 40.63 52 29 65 DNG AV3 15.44 52 30 65 DNG 12C 35.31 8

31 65 DNG 04H 23.40 8

38 65 DNG 20C 8.66 8

38 65 DNG 20C 15.69 8

38 65 DNG 23C 5.85 8

40 65 DNG 10H 18.97 8

40 65 DNG AVI 21.68 8

2 66 DNG 12C 7.25 104 2

66 DNG 12C 8.27 104 C-23 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 23 66 DNG 06H 28.36 52 25 66 DNG AV1 6.77 50 29 66 DNG AV3 15.94 50 29 66 DNG TSH 2.29 50 30 66 DNG 17C 19.22 8

31 66 DNG 07H 20.03 8

39 66 DNG 15C 13.60 8

40 66 DNG AV1 21.32 6

41 66 DNG 07H 25.22 8

45 66 DNG 1OH 8.05 8

5 67 DNG 10H 28.60 117 5

67 DNG 10H 29.35 117 8

67 DNG 23C 5.08 104 10 67 DNG 15C 2.66 104 10 67 DNG 19C 12.93 104 15 67 DNG 02H 32.81 76 16 67 DNG 12C 42.04 76 26 67 DNG 22C 9.91 52 39 67 DNG 07H 23.83 8

39 67 DNG 07H 38.55 8

41 67 DNG 07H 34.06 8

46 67 DNG 15C 16.33 12 47 67 DNG 02H 8.58 12 47 67 DNG 06H 22.38 12 10 68 DNG 01H 26.71 104 10 68 DNG 01H 27.40 104 10 68 DNG 02H 1.31 104 10 68 DNG 02H 2.79 104 12 68 DNG 23C 4.09 104 24 68 DNG 14C 33.52 50 26 68 DNG AV2 5.95 50 28 68 DNG 02H 6.89 50 28 68 DNG 02H 15.49 50 28 68 DNG 03H 19.09 50 28 68 DNG 03H 20.48 50 28 68 DNG AV4 10.62 50 40 68 DNG AVI 21.48 12 7

69 DNG 06H 18.84 104 7

69 DNG 12C 40.92 104 11 69 DNG 04H 15.26 104 17 69 DNG AV1 8.85 80 17 69 DNG AV1 14.51 80 17 69 DNG AV1 20.96 80 29 69 DNG AV3 2.16 52 C-24 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 33 69 DNG 01H 6.83 10 34 69 DNG 21C 5.26 12 34 69 DNG TSC 2.10 12 35 69 DNG 12C 20.28 84 35 69 DNG 12C 28.90 84 40 69 DNG AV2 23.16 10 40 69 DNG AV2 24.49 10 43 69 DNG 08H 2.65 12 46 69 DNG 18C 13.18 12 6

70 DNT 11C

.35 104 8

70 DNG 15C 39.99 104 11 70 DNG 01H 25.54 104 40 70 DNG 01H 18.80 12 41 70 DNG 02H 3.72 12 41 70 DNG TSC 6.09 12 42 70 DNG 18C 10.88 10 45 70 DNG 17C 28.40 12 45 70 DNG 20C 5.26 12 2

71 DNT 11C

.34 104 5

71 DNG 20C 5.60 104 6

71 DNG 01H 22.38 104 6

71 DNG 01H 23.71 104 7

71 DNG TSC 4.73 104 9

71 DNG 15C 22.17 104 9

71 DNG 18C 13.20 104 24 71 DNG AV3 11.58 52 30 71 DNG AV3 7.86 50 31 71 DNG 01H 16.59 50 31 71 DNG 06H 6.45 50 35 71 DNG 09H 20.83 50 39 71 DNG 19C 15.99 50 42 71 DNG 01H 2.11 50 2

72 DNT 11C

.34 104 5

72 DNT 11C

.26 117 5

72 DNT 11C

.31 104 7

72 DNT 11C

.31 104 8

72 DNT 11C

.34 104 16 72 DNG 21C 3.91 80 28 72 DNG 15C 42.38 52 28 72 DNG 16C 17.44 52 30 72 DNG AVI 15.03 52 30 72 DNG AV3 7.78 52 33 72 DNG 02H 12.33 52 34 72 DNG 13C 18.75 52 C-25 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 36 72 DNT 11C

-.31 52 40 72 DNG AV2 2.88 52 41 72 DNG 07H 42.52 52 41 72 DNG 09H 42.41 52 41 72 DNG 09H 43.71 52 41 72 DNG 13C 38.33 52 42 72 DNT 10H

-.20 52 43 72 DNT 1OH

-.34 52 44 72 DNG 09H 43.40 52 44 72 DNG AV4 26.71 52 44 72 DNG AV4 27.89 52 45 72 DNG 12C 39.23 52 45 72 DNG 12C 40.32 52 46 72 DNT 10H

-.55 52 46 72 DNT 10H

.20 52 46 72 DNT 10H

.56 52 47 72 DNG 21C 5.13 52 48 72 DNG 06H 40.03 54 48 72 DNG 06H 41.02 54 48 72 DNG 09H 42.11 54 1

73 DNG 05H 24.03 113 3

73 DNG 06H 33.54 115 3

73 DNT 22C

-.25 104 5

73 DNG 09H 18.10 117 6

73 DNG 04H 33.81 104 6

73 DNG 05H 9.54 104 13 73 DNG 21C 16.46 104 14 73 DNG TSH 4.87 78 16 73 DNG 08H 6.54 78 21 73 DNG TSH 1.41 78 30 73 DNG AV1 15.47 56 32 73 DNG 06H 11.61 56 36 73 DNG 19C 11.55 56 38 73 DNG 09H 42.74 56 38 73 DNG 09H 42.97 56 38 73 DNG 09H 43.20 56 39 73 DNG 01H

-.75 56 39 73 DNG 01H 1.18 56 41 73 DNG AV2 5.17 56 1

74 DNG TSH 6.88 113 14 74 DNG 02H 7.89 80 29 74 DNG 03H 22.97 54 30 74 DNG AV1 15.29 54 30 74 DNG AV2 4.99 54 C-26 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 30 74 DNG AV3 7.53 54 32 74 DNG AV2 14.59 54 39 74 DNG 07H 1.42 54 40 74 DNG 08H 20.88 54 40 74 DNG 08H 23.01 54 40 74 DNG AV2 23.72 54 22 75 DNG 02H 12.97 54 23 75 DNG 09H 14.85 56 30 75 DNG AV1 15.14 56 33 75 DNG 02H 23.20 56 48 75 DNG TSH 3.82 56 6

76 DNG 14C 24.24 62 7

76 DNG 04H 6.86 62 7

76 DNG 04H 7.08 96 17 76 DNG 14C 15.57 58 18 76 DNG 12C 40.52 58 25 76 DNG 17C 12.92 54 25 76 DNG 17C 32.12 54 25 76 DNG 20C 12.17 54 25 76 DNG 20C 13.08 54 28 76 DNG 02H 13.17 54 28 76 DNG 02H 19.07 54 28 76 DNG AV4 10.55 54 30 76 DNG AV3 7.43 54 35 76 DNG 04H 39.97 54 35 76 DNG 08H 37.88 54 37 76 DNT 1lC

-.25 54 38 76 DNT 11C

.40 54 39 76 DNG 04H 24.46 54 41 76 DNG 04H 1.81 54 44 76 DNG 10H 1.81 54 44 76 DNG 15C 43.77 54 44 76 DNG 16C 27.07 54 4

77 DNG 04H

.75 111 4

77 DNG 21C 11.01 64 4

77 DNG 21C 11.28 64 6

77 DNG 03H 9.07 64 8

77 DNG 02H 20.17 64 16 77 DNG 04H 29.82 60 16 77 DNG 20C 1.74 60 17 77 DNG 04H 20.13 60 19 77 DNG 03H 20.56 60 19 77 DNG 03H 22.80 60 19 77 DNG 03H 28.34 60 C-27 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 19 77 DNG 03H 35.27 60 34 77 DNG 01H 11.13 56 37 77 DNG 16C 43.23 56 39 77 DNG 05H 40.64 56 39 77 DNG 09H 41.42 56 39 77 DNG 09H 42.57 56 39 77 DNG 09H 44.01 56 40 77 DNG AV2 23.40 56 42 77 DNG 02H 9.12 56 45 77 DNG 07H 5.60 56 46 77 DNG 12C 44.85 56 46 77 DNG 13C 42.75 56 46 77 DNG 20C 13.42 56 46 77 DNT 1lC

-.55 56 46 77 DNT 11C

.31 56 8

78 DNG 04H 38.74 62 15 78 DNG 07H 22.17 62 19 78 DNG 14C 2.52 62 45 78 DNG 02H 27.24 54 45 78 DNG 04H 14.97 54 46 78 DNG AV3 20.37 54 47 78 DNG 06H 37.59 54 47 78 DNG 06H 37.99 54 47 78 DNG 06H 40.85 54 47 78 DNG 07H 6.15 54 47 78 DNG 07H 9.94 54 47 78 DNG 07H 12.08 54 47 78 DNG 07H 27.50 54 47 78 DNG 15C 10.94 54 1

79 DNG 17C 31.78 64 2

79 DNG 07H 38.10 111 7

79 DNG 02H 15.69 64 7

79 DNG 02H 19.92 64 7

79 DNG 02H 22.59 64 16 79 DNG 01H 2.76 64 17 79 DNG 06H 33.54 64 18 79 DNG 18C 3.22 64 20 79 DNG 16C 23.49 62 21 79 DNG 02H 26.49 62 21 79 DNG 04H 2.43 62 25 79 DNG 17C 14.59 56 29 79 DNG 18C 3.42 56 29 79 DNG 18C 5.06 56 30 79 DNG 02H 11.28 56 C-28 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 33 79 DNG 13C 23.55 56 34 79 DNG 06H 41.95 56 34 79 DNG 12C 44.71 56 34 79 DNT 11C

.34 56 35 79 DNG 15C 20.42 56 36 79 DNG 22C 6.53 56 37 79 DNG 03H 25.77 56 40 79 DNG AV2 23.89 56 41 79 DNG 05H 34.86 56 44 79 DNG 06H 16.45 56 48 79 DNT 1OH

.60 56 18 80 DNG 06H 7.26 64 21 80 DNG 07H 4.54 64 21 80 DNG 13C 37.99 64 39 80 DNG 15C 15.84 54 41 80 DNG 23C 3.34 54 42 80 DNG TSC 2.35 54 2

81 DNG 11C 2.24 64 2

81 DNG 12C 43.26 64 2

81 DNG 13C 10.10 64 2

81 DNG 14C 1.16 64 2

81 DNG 14C 7.31 64 11 81 DNG TSC 2.01 64 11 81 DNG TSC 7.93 64 11 81 DNG TSH 1.38 64 13 81 DNG 08H 4.40 64 13 81 DNG 08H 17.96 64 13 81 DNG 18C 8.91 64 13 81 DNG 18C 14.28 64 14 81 DNT 21C

-.36 64 25 81 DNT 07H

.20 56 25 81 DNT 09H

.00 56 25 81 DNT 13C

-.26 56 25 81 DNT 15C

.14 56 25 81 DNT 17C

.51 56 25 81 DNT 18C

.42 56 25 81 DNT 19C

.39 56 25 81 DNT 20C

.22 56 25 81 DNT 21C

.14 56 25 81 DNT 22C

.08 56 32 81 DNG 13C 12.71 56 41 81 DNG 14C 37.41 56 44 81 DNG 01H 12.52 56 48 81 DNG TSC

.84 56 C-29 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 2

82 DNG 03H 13.24 111 3

82 DNG 21C 4.25 62 4

82 DNG 03H 21.07 111 6

82 DNG 01H 3.04 62 6

82 DNG 12C 22.52 62 6

82 DNG 12C 28.68 62 6

82 DNG 12C 34.83 62 17 82 DNG 15C 16.05 62 22 82 DNG TSH 4.13 54 33 82 DNG 01H 4.30 54 38 82 DNG 03H 12.05 54 40 82 DNG 04H 27.71 54 42 82 DNG 18C 3.76 54 48 82 DNG 10H 8.43 54 48 82 DNG 15C 7.46 54 7

83 DNG 12C 40.37 64 11 83 DNG 02H 14.09 64 12 83 DNG 08H 43.83 64 28 83 DNG 12C 44.46 56 30 83 DNG 15C 25.62 56 30 83 DNG 15C 31.87 56 31 83 DNT 11C

.43 56 33 83 DNG TSC 7.66 56 33 83 DNG TSC 8.40 56 36 83 DNG 03H 31.80 56 36 83 DNG 06H 18.66 56 40 83 DNG AV2 24.01 56 43 83 DNG 02H 13.00 56 2

84 DNG 02H 18.10 111 2

84 DNG 03H 10.20 111 2

84 DNG 04H 29.47 111 14 84 DNG 05H 8.30 62 14 84 DNG 08H 11.41 62 32 84 DNG 02H 16.67 54 33 84 DNG 02H 12.89 54 37 84 DNG 17C 26.61 54 38 84 DNG 02H 10.13 54 38 84 DNG 02H 20.78 54 38 84 DNG 05H 15.51 54 38 84 DNG 14C 13.38 54 39 84 DNG 09H 43.71 54 39 84 DNT 11C

.43 54 41 84 DNG 04H 32.13 54 1

85 DNG 13C 41.53 64 C-30 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 3

85 DNG 12C 14.95 64 9

85 DNG 04H 15.03 64 9

85 DNG 04H 17.02 64 20 85 DNG 17C 43.99 64 22 85 DNG 12C 44.48 96 22 85 DNG 12C 44.57 100 22 85 DNG 12C 44.60 60 22 85 DNT 11C

.40 60 22 85 DNT 11C

.41 100 22 85 DNT 11C

.43 96 23 85 DNG 09H 42.49 60 23 85 DNG 09H 43.62 60 24 85 DNG 01H 19.55 60 31 85 DNG 01H 19.84 60 47 85 DNG 01H 22.45 56 48 85 DNG 09H 32.04 56 13 86 DNG 07H 12.46 62 13 86 DNG 17C 10.42 62 15 86 DNG 03H 23.47 62 20 86 DNG 16C 42.15 62 22 86 DNG 21C 14.42 58 31 86 DNT 10H

.71 58 39 86 DNG 06H 12.17 58 39 86 DNG 18C 6.06 58 7

87 DNG 03H 20.68 64 7

87 DNG 08H 2.20 64 17 87 DNG 12C 1.43 64 20 87 DNG 09H 29.08 64 20 87 DNG 12C 23.47 64 20 87 DNG 12C 39.78 64 20 87 DNG 12C 41.10 64 20 87 DNG 12C 42.23 64 20 87 DNG 12C 43.98 64 20 87 DNG 16C 3.55 64 20 87 DNG 16C 4.74 64 20 87 DNG 17C 4.53 64 22 87 DNG 08H 42.18 60 22 87 DNG 08H 43.29 60 22 87 DNG 13C 42.88 60 22 87 DNG 13C 44.03 60 24 87 DNG AV2

.65 60 28 87 DNG 16C 10.86 60 33 87 DNG 15C 34.52 60 33 87 DNG 18C 6.65 60 C-31 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 33 87 DNG 22C 12.33 60 34 87 DNG 13C 35.88 60 34 87 DNT 11C

.40 60 40 87 DNG AV2 23.75 60 44 87 DNG 16C 21.47 60 48 87 DNG 03H 2.15 60 6

88 DNG 12C 1.91 62 11 88 DNG 09H 43.19 62 11 88 DNG 09H 44.24 62 11 88 DNG 12C 41.73 62 11 88 DNG 12C 42.90 62 17 88 DNG 22C 2.60 62 19 88 DNG 15C 35.29 62 22 88 DNG 14C 38.70 58 23 88 DNG 12C 40.40 58 28 88 DNT 10H

.59 58 29 88 DNT 11C

-.37 58 32 88 DNG 04H 9.69 58 37 88 DNG 15C 34.46 58 40 88 DNG 12C 39.09 58 41 88 DNG 04H 8.31 58 4

89 DNG 10H 13.72 111 6

89 DNG 06H 33.29 64 9

89 DNG 02H 2.87 64 14 89 DNG 07H 16.28 64 23 89 DNG 12C 40.48 60 23 89 DNG 12C 43.23 60 28 89 DNG AV4 10.14 60 30 89 DNG AV2 12.65 60 31 89 DNG 07H 23.96 60 32 89 DNG 17C 11.97 60 34 89 DNG 01H 16.49 60 35 89 DNG 19C 9.06 60 40 89 DNG AV2 23.96 60 41 89 DNG 01H 14.19 60 43 89 DNG 04H 38.65 60 45 89 DNG 17C 15.89 60 3

90 DNG 17C 7.35 62 4

90 DNG 09H 43.16 111 4

90 DNG 10H 12.45 111 4

90 DNG 13C 28.96 62 4

90 DNG TSC 2.38 62 6

90 DNG 15C 24.52 62 17 90 DNG TSC 2.72 62 C-32 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 22 90 DNT 05H

-.37 58 34 90 DNG 04H 21.45 58 36 90 DNG 19C 2.54 58 39 90 DNG 09H 5.08 58 39 90 DNG 13C 38.33 58 42 90 DNG 19C 7.46 58 44 90 DNG 16C 17.04 58 4

91 DNG 15C 29.90 64 5

91 DNG 02H 2.47 115 5

91 DNG 02H 9.83 115 5

91 DNG 02H 14.27 115 5

91 DNG 02H 27.12 115 5

91 DNG 17C 23.39 64 7

91 DNT AV1

.00 64 15 91 DNG 22C 14.47 64 24 91 DNG AV3 14.44 60 29 91 DNG 01H 4.11 60 29 91 DNG 01H 4.32 96 29 91 DNG 01H 4.35 100 29 91 DNG 07H 16.57 96 29 91 DNG 07H 22.55 100 29 91 DNG 07H 22.56 60 29 91 DNG 21C 9.63 60 29 91 DNG 21C 9.70 100 29 91 DNG 21C 9.86 96 30 91 DNG 03H 15.18 60 34 91 DNG 01H 26.01 60 34 91 DNG 01H 26.42 60 34 91 DNG 02H 29.58 60 39 91 DNG 13C 27.76 60 43 91 DNG AVI 3.96 60 46 91 DNG 02H 24.16 60 48 91 DNG 12C 44.04 60 8

92 DNG 05H 11.11 62 8

92 DNG 08H 34.57 62 18 92 DNG 15C 5.57 62 30 92 DNG 13C 18.35 58 34 92 DNG 02H 31.32 58 34 92 DNG 17C 3.99 58 35 92 DNG 02H 22.03 58 35 92 DNG 13C 24.20 58 38 92 DNG 05H 38.00 58 40 92 DNG 09H 35.38 58 46 92 DNG 03H 18.24 58 C-33 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 14 93 DNG 13C 34.05 64 16 93 DNG 06H 41.32 64 21 93 DNG TSC 3.61 64 22 93 DNG 15C 40.96 60 25 93 DNG AV1 6.37 60 30 93 DNG 20C 7.83 60 7

94 DNG 09H 4.91 62 20 94 DNG 01H 2.01 62 29 94 DNG 15C 6.77 58 42 94 DNG 18C 1.18 58 9

95 DNG AV1 6.80 64 30 95 DNG TSH 4.68 60 31 95 DNG 07H 36.53 60 33 95 DNG 07H 7.66 60 43 95 DNG 03H 31.52 60 45 95 DNG 07H

.94 60 5

96 DNG 01H 11.35 115 5

96 DNG 15C 14.67 70 5

96 DNG 21C 12.08 70 16 96 DNG 07H 43.03 66 17 96 DNG 08H 40.22 66 21 96 DNG 16C 40.88 68 8

97 DNG AV4 12.61 100 8

97 DNG AV4 12.62 72 8

97 DNG AV4 12.82 96 8

97 DNG AV4 12.96 72 8

97 DNG AV4 13.04 100 8

97 DNG AV4 13.24 96 8

97 DNG AV4 13.26 72 8

97 DNG AV4 13.33 100 8

97 DNG AV4 13.59 96 8

97 DNG AV4 14.33 72 8

97 DNG AV4 14.37 100 8

97 DNG AV4 14.45 96 8

97 DNG AV4 15.16 72 8

97 DNT 11C

.46 72 8

97 DNT 11C

.49 100 8

97 DNT 11C

.55 96 17 97 DNG 16C 8.97 68 17 97 DNG 17C 25.48 68 23 97 DNG 09H 26.50 68 31 97 DNG 21C 8.76 68 36 97 DNG 12C 44.33 68 41 97 DNG 04H 8.51 68 C-34 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 41 97 DNG 17C 8.75 68 41 97 DNG 23C 4.12 68 41 97 DNT 20C

.08 68 1

98 DNG 21C 1.50 70 1

98 DNG 21C 7.66 70 1

98 DNG 21C 13.79 70 1

98 DNG 22C 7.08 70 1

98 DNG 22C 13.39 70 6

98 DNG 03H 20.62 70 6

98 DNG 13C 33.74 70 23 98 DNG 15C 3.03 66 24 98 DNG 14C 29.91 66 24 98 DNT 03H

-.37 66 27 98 DNG 05H 11.11 66 33 98 DNG 04H 8.25 66 34 98 DNG 02H 14.69 66 36 98 DNG 09H 27.03 66 2

99 DNG 01H 4.52 115 6

99 DNG 10H 9.28 72 6

99 DNT 12C

.00 72 13 99 DNG 02H 17.99 72 14 99 DNG 04H 23.47 72 18 99 DNG TSH 6.86 96 18 99 DNG TSH 6.93 72 18 99 DNG TSH 7.03 100 24 99 DNG 15C 38.88 68 29 99 DNG 02H 30.91 68 29 99 DNG 03H 1.67 68 29 99 DNG 03H 15.54 68 29 99 DNG 03H 22.41 68 29 99 DNG 03H 29.35 68 33 99 DNG 14C 33.86 68 33 99 DNG 15C 43.99 68 33 99 DNG 16C 37.00 68 9

100 DNG 20C 7.29 70 19 100 DNG 09H 35.82 70 19 100 DNG 12C 11.45 70 30 100 DNG 09H 41.64 66 40 100 DNG TSC 2.39 66 43 100 DNG 03H 24.41 66 43 100 DNG 03H 24.75 66 4

101 DNG 12C 39.50 72 6

101 DNG 04H 30.67 72 23 101 DNG 08H 14.52 68 C-35 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 24 101 DNG 22C 7.83 68 28 101 DNG 15C 19.83 68 28 101 DNG 15C 25.55 68 28 101 DNG 15C 27.00 68 28 101 DNG 15C 27.59 68 32 101 DNG 17C 22.74 68 39 101 DNG 02H 1.89 68 3

102 DNG 03H 18.33 115 7

102 DNG 15C 3.35 70 12 102 DNG 23C 8.10 70 16 102 DNG 02H 27.74 70 16 102 DNG 02H 30.16 70 17 102 DNG 01H 6.49 70 17 102 DNG 02H 27.43 70 17 102 DNG TSC 2.49 70 27 102 DNG AV3 5.38 66 29 102 DNG 13C 2.53 66 4

103 DNG 09H 28.54 115 4

103 DNG 09H 35.56 115 5

103 DNG 01H 18.09 117 5

103 DNG 02H 29.93 117 5

103 DNG 03H 31.67 117 5

103 DNG 12C 8.85 72 5

103 DNG 22C 15.20 72 5

103 DNG TSH 5.88 117 20 103 DNG 01H 12.44 72 29 103 DNG 16C 39.05 68 30 103 DNG 03H 5.03 68 34 103 DNG 19C 7.93 68 36 103 DNG 15C 8.38 68 37 103 DNG 06H 9.06 68 41 103 DNG 13C 34.71 68 11 104 DNG 03H 33.05 70 18 104 DNG 06H 32.24 70 25 104 DNG 04H 9.29 66 25 104 DNG 05H 41.97 66 33 104 DNG 08H 37.61 66 33 104 DNG 12C 14.52 66 1

105 DNG 17C 6.35 70 3

105 DNG 17C 8.42 70 8

105 DNG 08H 21.54 72 17 105 DNG 03H 13.24 72 17 105 DNG 03H 13.35 100 17 105 DNG 03H 13.36 96 C-36 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 25 105 DNG 17C 8.54 68 36 105 DNG 01H 1.80 68 7

106 DNT 10H

.31 70 12 106 DNG 19C 11.83 70 12 106 DNG 22C 8.25 70 12 106 DNG TSC

.89 70 12 106 DNG TSC 5.68 70 25 106 DNG 10H 19.58 66 25 106 DNG AVI 12.25 66 28 106 DNG 16C 21.30 66 36 106 DNG 16C 2.68 66 36 106 DNG 16C 3.25 66 36 106 DNG 16C 3.78 66 36 106 DNG TSC 4.44 66 1

107 DNG 17C 8.41 70 1

107 DNG 18C 7.82 70 10 107 DNG 17C 13.55 72 10 107 DNT 06H

.39 72 14 107 DNG 16C

.90 72 14 107 DNG 17C 32.35 72 18 107 DNG 08H 20.35 72 20 107 DNG 23C 2.88 72 26 107 DNT 02H

.14 68 27 107 DNG 16C 18.13 68 33 107 DNG 01H 7.24 68 34 107 DNG 02H 28.00 68 35 107 DNG 06H 10.10 68 2

108 DNG 01H 18.23 115 10 108 DNG 06H 36.66 70 16 108 DNG 05H 19.42 70 25 108 DNG 16C 22.11 66 25 108 DNG 16C 23.42 66 32 108 DNG 17C 42.67 66 3

109 DNG 17C 7.79 70 3

109 DNG 17C 19.79 70 4

109 DNG 02H 24.02 115 17 109 DNG 01H 16.07 72 18 109 DNG 17C 2.77 72 26 109 DNG 13C 29.53 68 31 109 DNG 16C 11.30 68 31 109 DNG 17C 31.64 68 33 109 DNG 13C 24.50 68 3

110 DNG 20C 7.81 74 5

110 DNG 16C 40.22 70 C-37 Appendix C

Dents and Dings S/G-A ROW COLUMN INDICATION LOCATION CAL NUMBER 6

110 DNG 15C 25.89 72 10 110 DNG 03H 21.97 74 21 110 DNG 15C 34.71 74 27 110 DNG 15C 3.33 66 28 110 DNG 16C 22.23 66 29 110 DNG 13C 43.20 66 5

111 DNG 23C 2.77 74 13 111 DNG 04H 11.30 76 17 111 DNG AVI 17.22 76 18 111 DNG 17C 17.65 76 18 111 DNG 17C 35.27 76 23 111 DNG 16C 31.74 68 27 111 DNG 21C 7.53 68 5

112 DNG 23C 6.46 74 16 112 DNG 14C 38.69 74 28 112 DNG 18C 9.07 66 4

113 DNG 10H 11.68 115 5

113 DNG 06H 29.12 117 5

113 DNG 15C 7.10 74 9

113 DNG 18C 7.19 76 11 113 DNG 04H 38.70 76 12 113 DNG 12C 7.19 76 24 113 DNG 07H 17.77 68 1

114 DNG 08H 37.51 117 2

114 DNG 13C 33.49 76 2

114 DNG 13C 39.73 76 2

114 DNT 14C

.37 76 5

114 DNG 01H 1.98 117 6

114 DNG 08H 12.72 76 16 114 DNG 04H 18.31 74 16 114 DNG 04H 18.81 74 20 114 DNG 17C 31.76 74 25 114 DNG 03H 28.77 66 25 114 DNG AVl 5.61 66 3

115 DNG 10H 5.48 117 3

115 DNG 15C 14.60 74 18 115 DNG 02H 3.05 76 24 115 DNG TSH 1.87 68 2

116 DNG 03H 27.23 115 3

116 DNG 23C 8.62 74 18 116 DNG 01H 4.21 76 18 116 DNG 03H 2.80 76 18 116 DNG 18C 7.37 76 L

11(

DNG 130 37.36 76 C-38 Appendix C 13C 37.36 76

Dents and Dings S/G-A C-39 Appendix C ROW COLUMN INDICATION LOCATION CAL NUMBER 6

117 DNG TSC 4.62 76 7

117 DNG 01H 16.78 76 10 117 DNG 02H 29.42 76 16 117 DNG AV1 20.00 76 18 117 DNG 02H 28.03 74 1

118 DNG 12C 35.81 74 6

118 DNG 08H 16.71 76 7

118 DNG 04H 4.26 74 11 118 DNG 04H 21.37 74 2

119 DNG 12C 36.50 76 3

119 DNG 15C 5.04 74 9

119 DNG 15C 2.86 76 9

119 DNG 15C 9.77 76 9

119 DNG 15C 16.66 76 9

119 DNG 15C 23.45 76 9

119 DNG 15C 30.56 76 2

120 DNG 15C 38.35 76 4

120 DNG 10H 17.26 115