0FPLo July 22, 2014 L-2014-233 10 CFR 50.55a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555-00001 Re:

Turkey Point Unit 3 Docket No. 50-250 Inservice Inspection Program Owner's Activity Report (OAR-I)

Attached find the Owner's Activity Report (Form OAR-i), for Turkey Point Unit 3 Fourth Inservice Inspection Interval Extended, Third Period, Second Refueling Outage and Fifth Inservice Inspection Interval, First Period, First Outage (PTN 3-27). The Form OAR-i, Owner's Activity Report, implements Code Case N-532-4.

Should there be any questions concerning this report, please contact Robert J. Tomonto at 305-246-7327.

Very truly yours Michael Kiley Vice President Turkey Point Nuclear Plant SM Attachment Ac40f4 Florida Power Light Company 9760 S.W. 344" Street Homestead, FL 33035

Page 1 of 5 FORM OAR-1 OWNER'S ACTIVITY REPORT Report Number: ISI-PTN-3-2014 Plant:

Turkey Point Nuclear Power Plant Unit 3 9760 SW 344th Street Homestead, Florida 33035 Commercial Service Date: December 14, 1972 Refueling Outage No.: PTN 3-27 Current Inspection Interval: ISI-Fifth IWE-Second Current Inspection Period: ISI Fourth Interval Extended-Third, Fifth Interval-First and IWE-Second Edition and Addenda of Section XI applicable to the inspection plans: ISI Fourth Interval Extended-1998 Edition with Addenda through 2000, ISI Fifth Interva-2007 Edition with Addenda through 2008 and IWE-2001 with Addenda through 2003.

Date and Revision of inspection plans: ISI Fourth Interval Extended-May 23, 2013 Rev.4, ISI Fifth Interval Effective-February 22. 2014 and IWE-March 3, 2009, Rev.0 Edition and Addenda of Section XI applicable to repairs and replacements, if different than the inspection plan: ASME Section XI 1998 Edition through 2000 Addenda before 2/22/2014, ASME Section Xl 2007 Edition through 2008 Addenda after 2/21/2014.

Code Cases Used: N-460, N-526, N-532-4, N-533-1, N-566-2, N-586-1, N-616, N-623, N-624, N-658, N-686-1, N-729-1 CERTIFICATE OF CONFORMANCE I certify that (a) the statements made in this report are correct; (b) the examinations and tests meet the Inspection plan as required by the ASME Code, Section Xl; and (c) the repair/replacement activities and evaluations supporting the completion of PTN3-27 conform to the requirements of Section XI.

Signed

  1. ,,/",,'

/*

,M4rDate 7/J/4 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Georgia and employed by HSB Global Standards have inspected the items described in this Owner's Activity Report, and state that, to the best of my knowledge and belief, the Owner has performed all activities represented by this report in accordance with the requirements of Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the repair/replacement activities and evaluation described in this report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising from or connected with this ins _(C Commissions A/A' /V12 92 a,-.4/ 6r24 ',T.

Inspector's Signa e

National Board, State,' Pr6vince and Endorsements Date

'7-Z %- Av'/

Page 2 of 5 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE I ITEMS WITH FLAWS OR RELEVANT CONDITIONS THAT REQUIRED EVALUATION FOR CONTINUED SERVICE Examination Category and Item Description Evaluation Description Item Number None None None

Page 3 of 5 FORM OAR-1 OWNER'S ACTIVITY REPORT TABLE 2 ABSTRACT OF REPAIR/REPLACEMENT ACTIVITIES REQUIRED FOR CONTINUED SERVICE Item Description Date Repair/Replacement Description Of Work Completed Plan Number Partial 1

pressurizer Repair Heater 4/22/2014 RR40300980-01 sleeve and seal sleeve leak weld Steam 1

Geeat Tube Plugging 4/5/2014 RR40161117-01 Generator Seal Table G-7 Replace fitting 4/22/2014 RR40174541-01 Fitting Seal weld 1

Check Valve Replace bolting 4/22/2014 RR40175916-01 1

Check Valve Replace valve 4/22/2014 RR40296473-01 and piping 1

Check Valve Replace valve 4/22/2014 RR40296474-01 and piping 1

Control Valve Replace Bolting 4/22/2014 RR40301151-01 1

Relief Valve Replace Valve 4/22/2014 RR40161042-01 1

Pipe and Elbows Replace pipe 4/22/2014 RR40239309-01 and elbows

Page 4 of 5 FORM OAR-1 OWNER'S ACTIVITY REPORT 1

Pipe and Elbows Replace pipe 4/22/2014 RR40239310-01 and elbows Cut and cap 2

Pipe Cap abandoned 4/15/2014 RR40239466-01 containment penetration 2

Globe Valve Replace bonnet 4/22/2014 RR40114073-02 bolting 2

Control Valve Replace Bonnet 4/22/2014 RR40177294-01 bolting Replace Valve 2

Isolation Valve Bonnet and 4/13/2014 RR40268776-01 Bolting 2

Isolation Valve Replace Bonnet 4/14/2014 RR40067027-01 Bolting 2

Isolation Valve Replace Bonnet 4/14/2014 RR40180313-01 Bolting 2

Charging Pump Replace Pump 11/09/2013 RR40055992-01 Block 2

Relief Valve Replace Bolting 4/22/2014 R40063900-01 2

Relief Valve Replace Bolting 4/22/2014 RR40120018-01 2

Relief Valve Replace Bolting 4/22/2014 RR40034137-01 2

Relief Valve Replace Bolting 4/22/2014 RR40034140-01

FORM OAR-1 OWNER'S ACTIVITY REPORT Steam 2

Generator Secondary Replace Bolt 4/22/2014 RR40219140-01 Manway 3

Isolation Valve Replace Valve 09/09/2012 RR40155017-01 3

Heat Exchanger Replace bolting 12/27/2013 RR40285565-01 3

Isolation Valve Replace Bolting 04/08/2014 RR40183227-01 3

Heat Exchanger Replace Bolting 10/24/2013 RR40204346-01 3

Heat Exchanger Replace Bolting 06/21/2013 RR40249174-01 3Check Valve Replace Valve 02/01/2013 RR40176280-01 and Bolting 3

Piping Replace Piping 04/25/2014 RR40189980-02