0 March 18, 2013 FPL.

L-2013-089 10 CFR 50.36 10 CFR 50.36a U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Re:

St. Lucie Units 1 and 2 Docket Nos. 50-335 and 50-389 Revised 2011 Annual Radioactive Effluent Release Report - Enclosure I Pursuant to 10 CFR 50.36a(a)(2) and Technical Specification (TS) 6.9.1.7, enclosed is a revision to Enclosure 1 of the 2011 Annual Radioactive Effluent Release Report for St.

Lucie Units 1 and 2. The report provides information for the 12-month period beginning January 1, 2011 and ending December 31, 2011.

The revision of the report is due to discovery that the release of carbon-14 (C-14) was being reported by the effluent accounting software as a particulate, versus being reported in the gaseous release form. The software was revised by the manufacturer, Canberra, and all effluent data from that period was re-processed using the revised version of the software.

Enclosure I includes the revised Combined Annual Radioactive Effluent Release Report, excluding the Solid Waste Storage and Shipments portion, which was unchanged.

Please contact us with any questions regarding this submittal.

Sincerely, Eric S. Katzman Licensing Manager St. Lucie Plant ESK/tlt Enclosure cc: American Nuclear Insurers Florida Power & Light Company 6501 S. Ocean Drive, Jensen Beach, FL 34957

FLORIDA POWER & LIGHT COMPANY ST. LUCIE UNITS 1 AND 2 ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY 1, 2012 THROUGH DECEMBER 31, 2012 L-2013-089 REPLACES ENCLOSURE 1 OF FPL LETTER L-2012-080 DATED MARCH 1, 2012, EXCLUDING THE SOLID WASTE STORAGE AND SHIPMENTS PORTION COMBINED ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT (44 PAGES) 3.0 TABLES 3.1 Gaseous Effluents & Liquid Effluents 3.2 Solid Waste StErage and Shipments (NOT REVISED) 3.3 Dose Assessments

)y '"nEMS Friday, February 22, 2013 10:29:47AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 5A and 5B - Liquid and Gas Batch Release Summary Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 A. Liquid Batch Release Totals

1. Number of Batch Releases
2. Total duration of batch releases
3. Maximum batch release duration
4. Average batch release duration
5. Minimum batch release duration B. Gas Batch Release Totals
1. Number of Batch Releases
2. Total duration of batch releases
3. Maximum batch release duration
4. Average batch release duration
5. Minimum batch release duration Units 1st Quarter 18 min 9.85E+03 min 7.05E+02 min 5.47E+02 min 3.87E+02 Units 1st Quarter 18 min 9.05E+03 min 1.24E+03 min 5.03E+02 min 2.10E+01 2nd Quarter 12 9.11E+03 1.15E+03 7.59E+02 4.92E+02 2nd Quarter 28 1.06E+04 1.44E+03 3.78E+02 4.80E+01 3rd Quarter 20 4.20E+04 1.98E+04 2.10E+03 1.OOE+02 3rd Quarter 38 8.36E+03 6.OOE+02 2.20E+02 3.OOE+01 4th Quarter 27 4.13E+04 2.05E+04 1.53E+03 5.OOE+02 4th Quarter 31 5.90E+03 6.00E+02 1.90E+02 3.OOE+01 Year Totals 77 1.02E+05 2.05E+04 1.33E+03 1.OOE+02 Year Totals 115 3.39E+04 1.44E+03 2.95E+02 2.1OE+01 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

-p1--nEMS E MUVAKgIemeit Sdtw'are Friday, February 22, 2013 10:30:06AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 6A and 6B - Liquid and Gas Abnormal Release Summary Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 se Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Qu ases 0

0 0

0 releases Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.00E-A. Liquid Abnormal Relea!

1. Number of Abnormal Rele
2. Total Activity of abnormal arter

+00 Year Totals 0

0.OOE+00 Year Totals 0

0.OOE+00 B. Gas Abnormal Release Totals

1. Number of Abnormal Releases
2. Total Activity of abnormal releases Units 1st Quarter 2nd Quarter 3rd Quarter 0

0 0

Ci 0.OOE+00 0.OOE+00 0.OOE+00 4th Quarter 0

0.OOE+00 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Friday, Febi Effluent Maiuugemnent Software Reg. Guide 1.21, Table 6A and 6B - Liquid and Gas Abnormal Release Summary Unit: PSL1 Starting: 1-Jan-2011 Ending: 31-Dec-2011 A. Liquid Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Qt

1. Number of Abnormal Releases 0

0 0

0

2. Total Activity of abnormal releases Ci O.OOE+00 0.OOE+00 0.OOE+00 0.OOE B. Gas Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Qt
1. Number of Abnormal Releases 0

0 0

0

2. Total Activity of abnormal releases Ci 0.00E+00 0.00E+00 0.OOE+00 0.00E ruary 22, 2013 10:23:59AM Florida Power & Light St. Lucie Power Plant larter

+00

,arter

+00 Year Totals 0

O.OOE+00 Year Totals 0

O.OOE+00 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Effluent MuLuigemnei it SofmwAre Friday, February 22, 2013 10:27:21AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 6A and 6B - Liquid and Gas Abnormal Release Summary Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 se Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th QI ases 0

0 0

0 releases Ci 0.00E+00 0.00E+00 0.OOE+00 0.OOE A. Liquid Abnormal Relea:

1. Number of Abnormal Rele
2. Total Activity of abnormal uarter

"+00 Year Totals 0

0.OOE+00 Year Totals 0

0.OOE+00 B. Gas Abnormal Release Totals

1. Number of Abnormal Releases
2. Total Activity of abnormal releases Units 1st Quarter 2nd Quarter 3rd Quarter 0

0 0

Ci 0.OOE+00 0.OOE+00 0.OOE+00 4th Quarter 0

0.OOE+00 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

TnEMS EiflueLnt Mmrimnxinee Software Page 1 of 1 Thursday, March 07, 2013 8:44:59AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table IA, Gaseous Effluents - Summation of All Releases Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 Total Release A. Fission and Activation Gases

1. Total Release
2. Average Release Rate for Period
3. Percent of Limit B. lodines and Halogens
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit C. Particulates
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit E. Gross Alpha
1. Total Release F. Carbon-14
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty Ci uCi/s Ci uCi/s Ci uCi/s Ci uCi/s Ci Ci uCi/s 1.88E+01 2.42E+00 2.17E-05 2.79E-06 2.85E-05 3.67E-06 4.42E+01 5.69E+00 2.50E-07 3.18E+00 4.09E-01 2.01E+01 2.55E+00 9.78E-07 1.24E-07 2.21E-05 2.81E-06 5.41E-01 6.88E-02 1.32E-07 3.62E+00 4.60E-01 1.88E+00 2.37E-01 2.19E-04 2.75E-05 1.55E-05 1.95E-06 1.61E-01 2.03E-02 2.42E-07 4.97E+00 6.25E-01 7.32E+00 9.21E-01 9.93E-06 1.25E-06 8.20E-06 1.03E-06 5.28E-01 6.65E-02 1.77E-07 4.18E+00 5.26E-01 4.81E+01 1.52E+00 2.51E-04 7.96E-06 7.44E-05 2.36E-06 4.55E+01 1.44E+00 8.02E-07 1.59E+01 5.06E-01 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

.1 Efilutnt MKuigerneInt Softmare Page 1 of 4 Friday, February 22, 2013 10:28:42AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: Site Starting: l-Jan-2011 Ending: 31-Dec-2011 Continuous Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Kr-85m Kr-87 Kr-88 Xe-131m Xe-133m Xe-135 Xe-138 Total For Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci O.OOE+00 1.24E-01 O.OOE+00 1.45E+01 2.80E+00 2.82E-02 4.86E-01 1.79E+01 2.17E-05 O.OOE+00 2.17E-05 5.12E-02 O.OOE+00 7.08E-01 1.53E+01 1.98E+00 1.66E-01 1.58E+00 1.98E+01 9.78E-07 0.OOE+00 9.78E-07 2.10E-01 O.OOE+00 7.23E-01 O.OOE+00 3.95E-01 O.OOE+00 O.OOE+00 1.33E+00

1. 14E-05 2.07E-04 2.19E-04 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 1.83E+00 0.OOE+00 2.68E+00 4.51E+00 1.35E-06 8.58E-06 9.93E-06 Annual 2.61E-01 1.24E-01 1.43E+00 2.98E+01 7.01E+00 1.94E-01 4.74E+00 4.35E+01 3.54E-05 2.16E-04 2.51E-04 B. Podines and Halogens 1-131 1-133 Total For Period C. Particulates Cr-51 Co-60 Cs-137 Ce-141 Ce-144 Total For Period Ci O.OOE+00 Ci 2.70E-05 Ci 9.87E-07 Ci 5.66E-07 Ci O.OOE+00 Ci 2.85E-05 3.29E-06 1.38E-05 2.64E-06 O.OOE+O0 2.31E-06 2.21E-05 O.OOE+O0 1.26E-05 2.89E-06 O.OOE+O0 O.OOE+O0 1.55E-05 O.OOE+O0 3.13E-06 5.07E-06 O.OOE+O0 O.OOE+O0 8.20E-06 3.29E-06 5.66E-05 1.16E-05 5.66E-07 2.31E-06 7.44E-05 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:28 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: Site Starting: l-Jan-2011 Ending: 31-Dec-2011 Page 2 of 4 Nuclides Released D. Tritium H-3 E. Gross Alpha G-Alpha F. Carbon-14 C-14 Units 1ST Quarter Ci Ci Ci 4.41E+01 2.50E-07

3. 18E+00 2ND Quarter 0.OOE+00 1.32E-07 3.62E+00 Continuous Mode 3RD Quarter 0.OOE+00 2.42E-07 4.97E+00 4TH Quarter Annual O.OOE+00 1.77E-07 4.18E+00 4.41E+01 8.02E-07 1.59E+01 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:28.

Page 3 of 4 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Ar-41 Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Total For Period Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci Ci 5.54E-01 2.86E-04 9.02E-03 0.OOE+00 0.OOE+00 0.OOE+00 1.07E-03 4.86E-03 3.17E-01 0.OOE+00 2.99E-02 0.OOE+00 0.00E+00

9. 16E-01 2.54E-01 2.61E-05 1.97E-02 3.56E-05 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 8.11E-03 1.49E-03 5.47E-05 8.32E-03 1.09E-04 2.91E-01 4.45E-01 1.09E-03 0.OOE+00 1.36E-04 1.04E-03 0.OOE+00 0.OOE+00 1.15E-03 8.40E-02 3.95E-04 1.84E-02 4.82E-03 0.OOE+00 5.56E-01 2.60E+00 1.25E-05 O.OOE+00 O.OOE+00 9.71E-05 1.24E-02 O.OOE+00 1.75E-03 1.88E-01 2.08E-04 1.99E-03 2.20E-03 0.OOE+00 2.81E+00 Annual 3.86E+00 1.42E-03 2.87E-02 1.71E-04 1.14E-03 1.24E-02 1.07E-03 7.75E-03 5.97E-01 2.09E-03 5.03E-02 1.53E-02 1.09E-04 4.58E+00 B. Iodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium H-3 Ci Ci Ci 0.OOE+00 0.OOE+00 1.59E-01 0.OOE+00 0.OOE+00 5.41E-01 0.OOE+00 0.OOE+00 1.61E-01 0.OOE+00 0.OOE+00 5.28E-01 0.OOE+00 0.OOE+00 1.39E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:28 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 Page 4 of 4 Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released E. Gross Alpha No Nuclides Found F. Carbon-14 No Nuclides Found Ci Ci 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

-L Eliluent Mmixgemeiit 'oftwire Page 1 of 1 Friday, February 22, 2013 10:22:10AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1A, Gaseous Effluents - Summation of All Releases Unit: PSL1 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Total Release A. Fission and Activation Gases

1. Total Release
2. Average Release Rate for Period
3. Percent of Limit B. lodines and Halogens
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit C. Particulates
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit D. Tritium
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit E. Gross Alpha
1. Total Release F. Carbon-14
1. Total Release
2. Average Release Rate for Period
3. Percent of Limit Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty Ci uCi/s Ci uCi/s Ci uCi/s Ci uCi/s Ci Ci uCi/s 1.06E+01 1.37E+00 1.01E-05 1.30E-06 2.78E-05 3.58E-06 2.68E+01 3.45E+00 1.44E-07 2.36E+00 3.03E-01 1.12E+01 1.43E+00 8.51E-07 1.08E-07 1.64E-05 2.08E-06 2.36E-01 3.OOE-02 5.57E-08 2.36E+00 3.OOE-01 5.92E-01 7.45E-02 2.19E-04 2.75E-05 1.17E-05 1.48E-06 1.09E-01 1.37E-02 1.45E-07 2.35E+00 2.96E-01 7.14E+00 8.98E-01 9.93E-06 1.25E-06 4.80E-06 6.04E-07 4.75E-01 5.98E-02 1.23E-07 1.57E+00 1.98E-01 2.96E+01 9.38E-01 2.39E-04 7.59E-06 6.07E-05 1.93E-06 2.76E+01 8.76E-01 4.68E-07 8.64E+00 2.74E-01 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

uFJ]leIt MauIL4.,teCt Soitwa*re Page 1 of 3 Friday, February 22, 2013 10:22:23AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: PS1 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Continuous Mode Nuclides Released A. Fission and Activation Gases Kr-87 Kr-88 Xe-131m Xe-133m Xe-138 Total For Period Units Ci Ci Ci Ci Ci Ci Ci Ci Ci 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter 1.24E-01 0.00E+00

7. 19E+00 2.60E+00 4.86E-01 1,O4E+IO1 1.01E-05 0.00E+00 1.01E-05 0.00E+00 7.08E-01
7. 18E+00 1.60E+00 1.58E+00 1.11E+01 8.51E-07 0.00E+00 8.51E-07 B. Iodines and Halogens 1-131 1-133 Total For Period C. Particulates Cr-5 1 Co-60 Cs-137 O.OOE+O0 O.OOE+O0 O.OOE+O0 3.95E-01 O.OOE+O0 3.95E-01
1. 14E-05 2.07E-04 2.19E-04 O.OOE+O0 1.15E-05 2.64E-07 0.00E+00 1.17E-05 O.OOE+00 O.OOE+00 O.OOE+O0 1.83E+00 2.68E+00 4.51E+00 1.35E-06 8.58E-06 9.93E-06 O.OOE+O0 2.82E-06 1.98E-06 O.OOE+00 4.80E-06 Annual 1.24E-01 7.08E-01 1.44E+01 6.43E+00 4.74E+00 2.64E+01 2.38E-05
2. 16E-04 2.39E-04 3.29E-06 5.01E-05 5.61E-06 1.73E-06 6,07E-05 Ci Ci Ci Ci Ci O.OOE+O0 2.70E-05 8.29E-07 O.OOE+O0 2.78E-05 3.29E-06 8.79E-06 2.54E-06 1.73E-06 1.64E-05 D.eTitiu ToalFr-ero D. Tritium H-3 Ci 2.67E+01 O.OOE+O0 O.OOE+O0 O.OOE+O0 2.67E+01 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: AI Locke User Al ocke[Server]:

PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:22 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: PSL1 Starting: l-Jan-2011 Ending: 31-Dec-2011 Page 2 of 3 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released E. Gross Alpha G-Alpha F. Carbon-14 C-14 Ci Ci 1.44E-07 2.36E+00 5.57E-08 2.36E+00 1.45E-07 2.35E+00 1.23E-07 1.57E+00 4.68E-07 8.64E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:22 Page 3 of 3 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL1 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Batch Mode Nuclides Released A. Fission and Activation Gases Ar-41 Kr-85m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Total For Period Units Ci Ci Ci Ci Ci Ci Ci Ci 1ST Quarter 2.15E-01 0.OOE+00 0.OOE+00 6.72E-03 0.OOE+00 1.67E-04 0.OOE+00 2.22E-01 1.64E-01 0.OOE+00 0.OOE+00

5. 10E-03 1.49E-03 0.OOE+00 8.32E-03 1.79E-01 1.69E-01 0.OOE+00 1.60E-04 2.25E-02 3.95E-04 2.45E-04 4.82E-03 1.97E-01 2.46E+00 1.25E-05 1.39E-03 1.63E-01 0.00E+00 1.57E-03 2.20E-03 2.63E+00 3.01E+00 1.25E-05 1.55E-03 1.98E-01 1.88E-03 1.98E-03 1.53E-02 3.23E+00 2ND Quarter 3RD Quarter 4TH Quarter Annual B. lodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium H-3 Ci Ci Ci Ci Ci 0.00E+00 0.OOE+00 1.59E-01 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 2.36E-01 0.OOE+00 0.OOE+00 0.OOE+00 0.00E+00 1.09E-01 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 4.75E-01 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 9.79E-01 0.OOE+00 0.OOE+00 E. Gross Alpha No Nuclides Found F. Carbon-14 No Nuclides Found If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Page I of 1

_.E M S Friday, February 22, 2013 10:25:45AM Effluent Mugce*,it Sofmtarc Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1A, Gaseous Effluents - Summation of All Releases Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Gases

1. Total Release Ci 8.21E+00 8.80E+00 1.29E+00 1.84E-01 1.85E+01
2. Average Release Rate for Period uCi/s 1.06E+00 1.12E+00 1.63E-01 2.31E-02 5.86E-01
3. Percent of Limit B. lodines and Halogens
1. Total Release Ci 1.16E-05 1.27E-07 0.OOE+00 0.OOE+00 1.17E-05
2. Average Release Rate for Period uCi/s 1.49E-06 1.62E-08 0.OOE+00 0.OOE+00 3.70E-07
3. Percent of Limit C. Particulates
1. Total Release Ci 7.24E-07 5.72E-06 3.80E-06 3.40E-06 1.36E-05
2. Average Release Rate for Period uCi/s 9.31E-08 7.28E-07 4.78E-07 4.28E-07 4.33E-07
3. Percent of Limit D. Tritium
1. Total Release Ci 1.74E+01 3.05E-01 5.24E-02 5.31E-02 1.78E+01
2. Average Release Rate for Period uCi/s 2.24E+00 3.88E-02 6.59E-03 6.68E-03 5.65E-01
3. Percent of Limit E. Gross Alpha
1. Total Release Ci 1.06E-07 7.65E-08 9.71E-08 5.40E-08 3.34E-07 F. Carbon-14
1. Total Release Ci 8.23E-01 1.26E+00 2.61E+00 2.61E+00 7.30E+00
2. Average Release Rate for Period uCi/s 1.06E-01 1.60E-01 3.29E-01 3.28E-01 2.32E-01
3. Percent of Limit User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

EMS Whien i~tuNbxagetelit Software Page 1 of 4 Friday, February 22, 2013 10:25:57AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Continuous Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Kr-85m Kr-88 Xe-13 im Xe-133m Xe-135 Total For Period Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 7.29E+00 2.02E-01 2.82E-02 7.52E+00 5.12E-02 O.OOE+00 8.10E+00 3.77E-01 1.66E-01 8.69E+00 2.10E-01 7.23E-01 0.OOE+00 0.OOE+00 0.OOE+00 9.32E-01 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 O.OOE+OO 2.61E-01 7.23E-01 1.54E+01 5.78E-01 1.94E-01 1.71E+01 B. lodines and Halogens 1-131 Ci 1.16E-05 1.27E-07 0.OOE+00 0.OOE+00 1.17E-05 C. Particulates Co-60 Cs-137 Ce-141 Ci Ci Ci Ci Ci O.OOE+00 1.58E-07 5.66E-07 O.OOE+00 7.24E-07 5.06E-06 9.30E-08 0.OOE+00 5.71E-07 5.72E-06

1. 17E-06 2.63E-06 0.OOE+00 0.OOE+00 3.80E-06
3. 10E-07 3.09E-06 0.OOE+00 0.OOE+00 3.40E-06 6.54E-06 5.97E-06

-5.66E-07 5.71E-07 1.36E-05 Ce-144 Total For Period D. Tritium H-3 E. Gross Alpha Ci Ci 1.74E+01 1.06E-07 0.OOE+0O 7.65E-08 0.OOE+00 9.71E-08 0.OOE+00 5.40E-08 1.74E+01 3.34E-07 G-Alpha If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:25 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Continuous Mode Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Page 2 of 4 Continuous Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Nuclides Released F. Carbon-14 C-14 Ci 8.23E-01 1.26E+00 2.61E+00 2.61E+00 7.30E+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:25 Page 3 of 4 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Batch Mode Nuclides Released A. Fission and Activation Gases Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Ar-41 Ci Kr-85m Ci Kr-85 Ci Kr-87 Ci Kr-88 Ci Kr-89 Ci Xe-131m Ci Xe-133m Ci Xe-133 Ci Xe-135m Ci Xe-135 Ci Xe-138 Ci Total For Period Ci 3.39E-01 2.86E-04 9.02E-03 0.OOE+00 0.OOE+00 0.OOE+00 1.07E-03 4.86E-03 3.10E-01 0.OOE+00 2.98E-02 0.OOE+00 6.94E-01 8.99E-02 2.61E-05 1.97E-02 3.56E-05 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.01E-03 0.OOE+00 5.47E-05 1.09E-04 1.13E-01 2.76E-01 1.09E-03 0.OOE+00 1.36E-04 1.04E-03 0.OOE+00 0.OOE+00 9.87E-04 6.15E-02 0.OOE+00 1.81E-02 0.OOE+00 3.59E-01 1.45E-01 0.OOE+00 0.OOE+00 0.OOE+00 9.71E-05 1.24E-02 0.OOE+00 3.54E-04 2.48E-02 2.08E-04 4.22E-04 0.OOE+00 1.84E-01 8.51E-01 1.41E-03 2.87E-02 1.71E-04 1.14E-03 1.24E-02 1.07E-03 6.20E-03 3.99E-01 2.08E-04 4.84E-02 1.09E-04 1.35E+00 B. lodines and Halogens No Nuclides Found C. Particulates No Nuclides Found D. Tritium H-3 Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.05E-01 0.OOE+00 0.OOE+00 0.OOE+00 5.24E-02 0.OOE+00 0.OOE+00 0.OOE+00 5.31E-02 0.OOE+00 0.OOE+00 0.OOE+00 4.1OE-01 0.OOE+00 E. Gross Alpha No Nuclides Found If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:25 Reg. Guide 1.21, Table 1B, Gaseous Effluents - Ground Level Release - Batch Mode Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Page 4 of 4 Nuclides Released F. Carbon-14 No Nuclides Found Batch Mode Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke I

[Server]: PSLSA37 [Database]: NEPSOEMP

AL B1flelit MMUugenieiit SOftAWCjr Page 1 of 1 Friday, February 22, 2013 10:29:13AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents - Summation of All Releases Unit: Site Starting: l-Jan-2011 Ending: 31-Dec-2011 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Products

1. Total Release
2. Average Concentration
3. Percent of Limit B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit C. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit D. Gross Alpha Activity
1. Total Release
2. Average Concentration E. Primary Liquid Release Volume
1. Total Release F. Dilution Volume
1. Total Release G. Average Stream Flow
1. Total Release Ci uCi/mL Ci uCi/mL Ci uCi/mL Ci uCi/mL Liters Liters mA3/s 1.43E-02 7.02E-10 6.06E+01 2.97E-06 9.04E-03 4.44E-10 0.00E+00 0.OOE+00 1.43E+06 2.04E+10 0.00E+00 2.82E-02 9.83E-10 4.22E+01 1.47E-06 7.86E-05 2.74E-12 0.00E+00 0.00E+00 1.04E+06 2.86E+10 0.00E+00 4.13E-02 2.53E-10 1.09E+02 6.67E-07 7.68E-03 4.71E-11 0.OOE+00 0.OOE+00 5.88E+07 1.63E+11 0.OOE+00 9.02E-02 1.04E-09 6.57E+01 7.61E-07 3.32E-02 3.85E-10 0.OOE+00 0.OOE+00 1.50E+08 8.64E+10 0.00E+00 1.74E-01 5.83E-10 2.77E+02 9.29E-07 5.OOE-02 1.68E-10 0.00E+00 0.OOE+00 2.12E+08 2.99E+11 0.OOE+00 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

-1 Effluent I'viguemenit Software Page 1 of 1 Friday, February 22, 2013 10:22:50AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2A, Liquid Effluents - Summation of All Releases Unit: PSL1 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Products

1. Total Release
2. Average Concentration
3. Percent of Limit B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit C. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit D. Gross Alpha Activity
1. Total Release
2. Average Concentration E. Primary Liquid Release Volume
1. Total Release F. Dilution Volume
1. Total Release G. Average Stream Flow
1. Total Release Ci uCi/mL Ci uCi/mL Ci uCi/mL Ci uCi/mL Liters Liters mA3/s 7.15E-03 7.02E-10 3.03E+01 2.97E-06 4.52E-03 4.44E-10 0.00E+00 0.OOE+00 7.14E+05 1.02E+10 0.OOE+00 1.41E-02 9.83E-10 2.11E+01 1.47E-06 3.93E-05 2.74E-12 0.OOE+00 0.OOE+00 5.19E+05 1.43E+10 0.OOE+00 2.06E-02 2.53E-10 5.44E+01 6.67E-07 3.84E-03 4.71E-11 0.OOE+00 0.OOE+00 2.94E+07 8.16E+10 0.OOE+00 4.51E-02 1.04E-09 3.29E+01 7.61E-07 1.66E-02 3.85E-10 0.OOE+00 0.OOE+00 7.51E+07 4.32E+10 0.OOE+00 8.70E-02 5.83E-10 1.39E+02 9.29E-07 2.50E-02 1.68E-10 0.OOE+00 0.OOE+00 1.06E+08 1.49E+11 0.OOE+00 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Effluent M vbLLgmnM t Sofrware Page 1 of 1 Friday, February 22, 2013 10:26:29AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table. 2A, Liquid Effluents - Summation of All Releases Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Uncertainty A. Fission and Activation Products

1. Total Release
2. Average Concentration
3. Percent of Limit B. Tritium
1. Total Release
2. Average Concentration
3. Percent of Limit C. Dissolved and Entrained Gases
1. Total Release
2. Average Concentration
3. Percent of Limit D. Gross Alpha Activity
1. Total Release
2. Average Concentration E. Primary Liquid Release Volume
1. Total Release F. Dilution Volume
1. Total Release G. Average Stream Flow
1. Total Release Ci uCi/mL Ci uCi/mL Ci uCi/mL Ci uCi/mL Liters Liters m^3/s 7.15E-03 7.02E-10 3.03E+01 2.97E-06 4.52E-03 4.44E-10 0.OOE+00 0.OOE+00 7.14E+05 1.02E+10 0.OOE+00 1.41E-02 9.83E-10 2.11E+01 1.47E-06 3.93E-05 2.74E-12 0.OOE+00 0.OOE+00
5. 19E+05 1.43E+10 0.OOE+00 2.06E-02 2.53E-10 5.44E+0 1 6.67E-07 3.84E-03 4.71E-11 0.OOE+00 0.OOE+00 2.94E+07 8.16E+10 0.OOE+00 4.51E-02 1.04E-09 3.29E+01 7.61E-07 1.66E-02 3.85E-10 0.OOE+00 0.OOE+00 7.51E+07 4.32E+10 0.OOE+00 8.70E-02 5.83E-10 1.39E+02 9.29E-07 2.50E-02 1.68E-10 0.OOE+00 0.OOE+00 1.06E+i08 1.49E+ 11 0.OOE-hOO User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:23 Page 2 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: P51 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Batch Mode Nuclides Released A. Fission and Activation Products Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual C-14 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Ni-63 Zn-65 Br-82 Rb-88 Sr-91 Zr-95 Zr-97 Nb-95 Nb-97 Ru-103 Ag-110m Sn-113 Sb-122 Sb-124 Sb-125 Te-129m Te-129 1-130 2.11E-03 2.19E-04 5.20E-05 1.06E-03 4.75E-05 0.OOE+00 2.48E-03 3.58E-04 0.OOE+00 2.73E-06 2.53E-06 0.OOE+00 3.51E-06 4.08E-05 8.90E-05 3.48E-05 4.22E-05 0.OOE+00 2.99E-04 2.95E-06 0.OOE+00 2.87E-06 2.50E-04 0.OOE+00 2.62E-05 0.OOE+00 2.53E-03 2.61E-04 4.38E-05 9.35E-03 1.49E-04 3.12E-06 7.40E-04 2.24E-04 0.OOE+00 2.27E-06 2.19E-06 0.OOE+00 8.81E-06 7.40E-05 0.OOE+00 9.82E-05 8.42E-05 1.89E-06 1.74E-04 1.00E-05 0.OOE+00 3.59E-06 2.59E-04 5.22E-05 0.OOE+00 1.42E-06 1.40E-02 7.42E-05 1.09E-04 3.12E-03 4.50E-05 4.07E-06 9.66E-04 8.32E-04 2.33E-04 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 6.85E-05 8.17E-05 1.38E-04 3.23E-04 0.OOE+00 2.68E-04 0.OOE+00 0.OOE+00 0.OOE+00 2.86E-04 4.85E-05 0.OOE+00 0.OOE+00 3.51E-02 1.56E-04 1.26E-04 3.75E-03 4.05E-05 1.32E-06 1.85E-03 1.24E-03 4.45E-04 1.18E-05 0.OOE+00 1.42E-04 0.OOE+00 2.74E-05 1.62E-04 1.15E-04 8.22E-04 0.OOE+00 4.75E-04 4.83E-06 2.88E-06 0.OOE+00 4.57E-04 1.34E-04 0.OOE+00 0.OOE+00 5.37E-02

7. 1OE-04 3.30E-04 1.73E-02 2.82E-04 8.50E-06 6.04E-03 2.65E-03 6.78E-04 1.68E-05 4.72E-06 1.42E-04 1.23E-05 2.11E-04 3.33E-04 3.87E-04 1.27E-03 1.89E-06 1.22E-03 1.78E-05 2.88E-06 6.45E-06 1.25E-03 2.35E-04 2.62E-05 1.42E-06 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:23 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: PSL1 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Batch Mode Nuclides Released 1-131 1-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Units Ci Ci Ci Ci Ci Ci Ci Ci 1ST Quarter 2.64E-06 6.86E-06 2.59E-06 O.OOE+00 4.83E-06 O.OOE+00 O.OOE+00 7.15E-03 2ND Quarter O.OOE+00 O.OOE+00 2.55E-06 2.46E-06 O.OOE+00 4.53E-06 O.OOE+00 1.41E-02 3RD Quarter O.OOE+00 O.OOE+00 3.36E-06 5.71E-06 4.34E-06 O.OOE+00 4.96E-05 2.06E-02 4TH Quarter Annual 0.OOE+00 0.OOE+00 0.OOE+00 7.37E-06 1.36E-05 9.52E-06 1.69E-05 4.51E-02 2.64E-06 6.86E-06 8.50E-06 1.55E-05 2.27E-05 1.41E-05 6.65E-05 8.70E-02 Total For Period B. Tritium H-3 Ci 3.03E+01 2.11E+01 5.44E+01 3.29E+01 1.39E+02 C. Dissolved and Entrained Gases Ar-41 Kr-85m Kr-87 Kr-88 Xe-133m Xe-133 Xe-135 Total For Period D. Gross Alpha Activity No Nuclides Found Ci Ci Ci Ci Ci Ci Ci Ci 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.72E-05 4.48E-03 1.71E-06 4.52E-03 0.OOE+00 0.00E+00 0.OOE+00 0.00E+00 0.OOE+00 3.93E-05 0.OOE+00 3.93E-05 2.03E-06 0.00E+00 0.OOE+00 0.OOE+00 1.36E-05 3.82E-03 6.97E-06 3.84E-03 5.46E-03 3.03E-05 4.06E-06 4.55E-05 7.33E-05 1.03E-02 6.63E-04 1.66E-02 5.46E-03 3.03E-05 4.06E-06 4.55E-05 1.24E-04 1.87E-02 6.71E-04 2.50E-02 Ci O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:26 Page 2 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: P512 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Batch Mode Nuclides Released A. Fission and Activation Products Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter C-14 Cr-51 Mn-54 Fe-55 Fe-59 Co-57 Co-58 Co-60 Ni-63 Zn-65 Br-82 Rb-88 Sr-91 Zr-95 Zr-97 Nb-95 Nb-97 Ru-103 Ag-110m Sn-113 Sb-122 Sb-124 Sb-125 Te-129m Te-129 1-130 2.11E-03 2.19E-04 5.20E-05 1.06E-03 4.75E-05 O.OOE+O0 2.48E-03 3.58E-04 O.OOE+0O 2.73E-06 2.53E-06 O.OOE+O0 3.51E-06 4.08E-05 8.90E-05 3.48E-05 4.22E-05 O.OOE+0O 2.99E-04 2.95E-06 O.OOE+O0 2.87E-06 2.50E-04 O.OOE+O0 2.62E-05 O.OOE+00 2.53E-03 2.61E-04 4.38E-05 9.35E-03 1.49E-04 3.12E-06 7.40E-04 2.24E-04 O.OOE+O0 2.27E-06 2.19E-06 O.OOE+O0 8.81E-06 7.40E-05 O.OOE+O0 9.82E-05 8.42E-05 1.89E-06 1.74E-04 1.OOE-05 O.OOE+O0 3.59E-06 2.59E-04 5.22E-05 O.OOE+O0 1.42E-06 1.40E-02 7.42E-05 1.09E-04 3.12E-03 4.50E-05 4.07E-06 9.66E-04 8.32E-04 2.33E-04 O.OOE+00 O.OOE+00 O.OOE+0O O.OOE+0O 6.85E-05 8.17E-05 1.38E-04 3.23E-04 O.OOE+0O 2.68E-04 O.OOE+0O O.OOE+0O O.OOE+O0 2.86E-04 4.85E-05 O.OOE+00 O.OOE+O0 3.51E-02 1.56E-04 1.26E-04 3.75E-03 4.05E-05 1.32E-06 1.85E-03 1.24E-03 4.45E-04

1. 18E-05 O.OOE+00 1.42E-04 O.OOE+0O 2.74E-05 1.62E-04 1.15E-04 8.22E-04 O.OOE+0O 4.75E-04 4.83E-06 2.88E-06 O.OOE+OO 4.57E-o4 1.34E-04 O.OOE+00 O.OOE+00 Annual 5.37E-02
7. 1OE-04 3.30E-04 1.73E-02 2.82E-04 8.50E-06 6.04E-03 2.65E-03 6.78E-04 1.68E-05 4.72E-06 1.42E-04 1.23E-05 2.11E-04 3.33E-04 3.87E-04 1.27E-03 1.89E-06 1.22E-03 1.78E-05 2.88E-06 6.45E-06 1.25E-03 2.35E-04 2.62E-05 1.42E-06 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Florida Power & Light, St. Lucie Power Plant 2/22/2013 10:26 Page 3 of 3 Reg. Guide 1.21, Table 2B, Liquid Effluents - Batch Mode Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Batch Mode Nuclides Released 1-131 1-135 Cs-136 Cs-137 Cs-138 Ba-140 La-140 Total For Period Units Ci Ci Ci Ci Ci Ci Ci Ci IST Quarter 2.64E-06 6.86E-06 2.59E-06 0.OOE+00 4.83E-06 0.OOE+00 0.OOE+00 7.15E-03 2ND Quarter 0.00E+00 0.OOE+00 2.55E-06 2.46E-06 0.O0E+00 4.53E-06 0.OOE+00 1.41E-02 3RD Quarter 0.OOE+00 0.OOE+00 3.36E-06 5.71E-06 4.34E-06 0.OOE+00 4.96E-05 2.06E-02 4TH Quarter O.OOE+00 O.OOE+00 O.OOE+00 7.37E-06 1.36E-05 9.52E-06 1.69E-05 4.51E-02 Annual 2.64E-06 6.86E-06 8.50E-06 1.55E-05 2.27E-05 1.41E-05 6.65E-05 8.70E-02 B. Tritium H-3 C. Dissolved and Entrained Gases Ci 3.03E+01 2.11E+01 5.44E+01 3.29E+01 1.39E+02 Ar-41 Kr-85m Kr-87 Kr-88 Xe-133m Xe-133 Xe-135 Total For Period Ci Ci Ci Ci Ci Ci Ci Ci 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 3.72E-05 4.48E-03 1.71E-06 4.52E-03 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 3.93E-05 0.OOE+00 3.93E-05 2.03E-06 0.OOE+00 0.OOE+00 0.OOE+00 1.36E-05 3.82E-03 6.97E-06 3.84E-03 5.46E-03 3.03E-05 4.06E-06 4.55E-05 7.33E-05 1.03E-02 6.63E-04 1.66E-02 5.46E-03 3.03E-05 4.06E-06 4.55E-05 1.24E-04 1.87E-02 6.71E-04 2.50E-02 D. Gross Alpha Activity No Nuclides Found Ci 0.OOE+00 0.00E+00 0.OOE+00 O.OOE+00 O.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

InEMS Eflutent M.axLigmmlnU Sd1~vire Page 1 of 3 Friday, February 22, 2013 10:29:27AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, Table 2B, Liquid Effluents - Continuous Mode Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 Continuous Mode Nuclides Released A. Fission and.Activation Products No Nuclides Found B. Tritium No Nuclides Found C. Dissolved and Entrained Gases No Nuclides Found D. Gross Alpha Activity No Nuclides Found Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Ci Ci Ci Ci 0.OOE+00 0.00E+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 0.OOE+00 If Not Detected, Nuclide is Not Reported. Zeroes in this table indicates that no radioactivity was present at detectable levels.

User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

  • EMS N

LfnUL LALenelt SdtOAjtt Page 1 of 1 Thursday, March 07, 2013 9:00:28AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 - Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 Organ Dose Bone Limit Units mRem mRem 1ST Quarter 1.07E-01 2ND Quarter 1.21E-01 3RD Quarter 1.67E-01 4TH Quarter Annual 1.40E-01 5.35E-01 Percent of Limit Liver mRem 1.18E-01 1.21E-01 1.66E-01 1.40E-01 5.46E-01 Limit mRem Percent of Limit Total Body mRem 1.18E-01 1.21E-01 1.66E-01 1.40E-01 5.46E-01 Limit mRem Percent of Lmit Thyroic mRem 1.25E-01 1.22E-01 1.70E-01 1.40E-01 5.56E-01 Limit mRem Percent of Limit Kidney mRem 1.79E-02 1.45E-02 1.98E-02 1.67E-02 6.88E-02 Limit mRem Percent of Limit Lung mRem 1.18E-01 1.21E-01 1.66E-01 1.40E-01 5.46E-01 Limit mRem Percent of Limit GI-Lli mRem 1.18E-01 1.21E-01 1.66E-01 1.40E-01 5.46E-01 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

I EFltit M.u.,entet SofiN4e Page 1 of 1 Friday, February 22, 2013 10:21:53AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 - Doses due to Radiolodines, Tritium, and Particulates in Gaseous Releases Unit: PSL1 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Organ Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 7.92E-02 2ND Quarter 7.91E-02 3RD Quarter 7.89E-02 4TH Quarter 5.27E-02 Annual 2.90E-01 Liver mRem 8.62E-02 7.91E-02 7.89E-02 5.28E-02 2.97E-01 Limit mRem Percent of Limit Total Body mRem 8.62E-02 7.89E-02 7.89E-02 5.27E-02 2.97E-01 Limit mRem Percent of Limit Thyroid mRem 8.91E-02 7.92E-02 8.21E-02 5.31E-02 3.03E-01 Limit mRem Percent of Limit Kidney mRem 1.26E-02 9.42E-03 9.40E-03 6.30E-03 3.77E-02 Limit mRem Percent of Limit Lung mRem 8.62E-02 7.90E-02 7.89E-02 5.27E-02 2.97E-01 Limit mRem Percent of Limit GI-Lli mRem 8.62E-02 7.89E-02 7.88E-02 5.27E-02 2.97E-01 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

K :E-MlttM=gMeltSdV-Page 1 of 1 Friday, February 22, 2013 10:25:30AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E3 - Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Organ Dose Bone Limit Units mRem mRem 1ST Quarter 2.76E-02 2ND Quarter 4.23E-02 3RD Quarter 8.76E-02 4TH Quarter 8.75E-02 Annual 2.45E-01 Percent of Limit Liver mRem 3.22E-02 4.23E-02 8.76E-02 8.74E-02 2.49E-01 Limit mRem Percent of Limit Total Body mRem 3.22E-02 4.23E-02 8.74E-02 8.72E-02 2.49E-01 Limit mRem Percent of Limit Thyroid mRem 3.55E-02 4.23E-02 8.74E-02 8.72E-02 2.52E-01 Limit mRem Percent of Limit Kidney mRem 5.30E-03 5.06E-03 1.04E-02 1.04E-02 3.11E-02 Limit mRem Percent of Limit Lung mRem 3.22E-02 4.23E-02 8.74E-02 8.72E-02 2.49E-01 Limit mRem Percent of Limit GI-Lli mRem 3.22E-02 4.23E-02 8.74E-02 8.72E-02 2.49E-01 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

rJ11niern Ntuu L rnieIt S~oftware Page 1 of 1 Thursday, March 07, 2013 9:04:01AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 - Air Doses Due To Gaseous Releases Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 NG Dose Gamma Air Limit Units mRad mRad 1ST Quarter 7.OOE-04 2ND' Quarter 1.58E-03 3RD Quarter 7.92E-04 4TH Quarter 2.52E-03 Annual 5.59E-03 Percent of Limit Beta Air mRad 1.32E-03 1.57E-03 2.42E-04 1.23E-03 4.37E-03 Limit mRad Percent of Limit NG Total Body mRem 6.16E-04 1.46E-03 7.61E-04 2.40E-03 5.24E-03 Limit mRem Percent of Limit NG Skin mRem 1.51E-03 2.68E-03 1.06E-03 3.80E-03 9.05E-03 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

~-EMS Ig Efliltetnt.Nlumgemnt Sýoftarc Page 1 of 1 Friday, February 22, 2013 10:21:39AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 - Air Doses Due To Gaseous Releases Unit: PSL1 Starting: 1-Jan-2011 Ending: 31-Dec-2011 NG Dose Gamma Air Limit Percent of Limit Units 1ST Quarter 2ND Quarter 3RD Quarter mRad 4.67E-04 1.44E-03 8.72E-05 mRad 4TH Quarter 2.44E-03 Annual 4.44E-03 Beta Air mRad 8.18E-04 1.04E-03 6.21E-05 1.20E-03 3.13E-03 Limit mRad Percent of Limit NG Total Body mRem 4.18E-04 1.36E-03 8.16E-05 2.33E-03 4.19E-03 Limit mRem Percent of Limit NG Skin mRem 1.01E-03 2.29E-03 1.42E-04 3.68E-03 7.12E-03 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

)A.,

EMS E_

fluntte~ Muut~vmnie Sofm-are Page 1 of 1 Friday, February 22, 2013 10:25:16AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec E2 - Air Doses Due To Gaseous Releases Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 NG Dose Gamma Air Limit Units 1ST Quarter 2ND Quarter 3RD Quarter mRad 2.32E-04 1.32E-04 7.05E-04 mRad 4TH Quarter 8.02E-05 Annual 1.15E-03 Percent of Limit Beta Air mRad 5.07E-04 5.27E-04 1.80E-04 3.23E-05 1.25E-03 Limit mRad Percent of Limit NG Total Body mRem 1.98E-04 1.01E-04 6.79E-04 7.62E-05 1.05E-03 Limit mRem Percent of Limit NG Skin mRem 4.99E-04 3.93E-04 9.18E-04 1.15E-04 1.93E-03 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Gas Status Summary Report Wednesday, March 6, 2013 15:11 Page 12 of 13 Gas Status Summary Report Wednesday, March 6, 2013 15:11 Page 12 of 13 Period:

Ann, 2011 Site/Unit/Discharge Point:

Site Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor Agegroup Bone Liver Total Body NW Site Boundary - In Infant 5.348E-01 5.464E-01 5.458E-01 WNW Site Boundary - I Infant 6.872E-05 6.872E-05 6.872E-05 Maximum Doserate by Organ:

5.348E-01 5.464E-01 5.458E-01 Thyroid 5.566E-01 6.872E-05 5.566E-01 Kidney 6.883E-02 6.872E-05 6.883E-02 Lung 5.459E-01 6.872E-05 5.459E-01 GI-Lli 5.458E-01 6.872E-05 5.458E-01 Skin 0.OOOE+00 0.OOOE+00 O.OOOE+00 Maximum Organ Doserate (mRem/yr):

Maximum Total Body Doserate (mRem/yr):

5.566E-01 5.458E-01 Site Boundary NG Doserate Summary Gas Receptor Location NW Site Boundary WNW Site Boundary Maximum NG Dose Rate:

Gamma (mRad/yr)

Beta (mRad/yr) 5.593E-03 4.372E-03 4.818E-03 3.766E-03 5.593E-03 4.372E-03 Total Body (mRem/yr) 5.244E-03 4.518E-03 5.244E-03 Skin (mRem/yr) 9.047E-03 7.793E-03 9.047E-03 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Gas Status Summary Report Wednesday, March 6, 2013 15:11 Page 13 of 13 Gas Status Summary Report Wednesday, March 6, 2013 15:11 Page 13 of 13 Period:

Ann, 2011 Site/Unit/Discharge Point:

Site Maximum Individual NNG Dose Summary - Note: All Doses in mRem Receptor SE Nearest Res - Adult SE Nearest Res -

Child SE Nearest Res - Infant SE Nearest Res - Teenager SE Visitor - Adult SSW Near Garden - Adult SSW Near Garden - Child SSW Near Garden -

WSW Near Milk - Adult WSW Near Milk - Child WSW Near Milk - Infant WSW Near Milk - Teenager Agegroup Adult Child Infant Teenager Adult Adult Child Teenager Adult Child Infant Teenager Bone 1.170E-04 1.170E-04 1.169E-04 1.169E-04 5.432E-05 9.060E-06 9.060E-06 9.054E-06 2.515SE-05 3.851E-05 5.770E-05 7.474E-06 Liver 1.170E-04 1.170E-04 1.170E-04 1.170E-04 5.431E-05 9.059E-06 9.059E-06 9.059E-06 2.672E-05 3.801lE-05 6.227E-05 1.013E-05 Total Body 1.168E-04 1.168E-04 1.167E-04 1.168E-04 5.425E-05 9.049E-06 9.045E-06 9.046E-06 2.468E-05 2.399E-05 2.443E-05 3.775E-06 Thyroid 1.365E-04 1.474E-04 1.450E-04 1.415E-04 6.285E-05 1.040E-05 1.115E-05 1.074E-05 1.211E-04 3.194E-04 7.350E-04 1.524E-04 Kidney 1.169E-04 1.168E-04 1.167E-04 1.169E-04 5.429E-05 9.054E-06 9.046E-06 9.054E-06 2.331E-05 2.346E-05 2.345E-05 3.175E-06 Lung 1.234E-04 1.246E-04 1.232E-04 1.264E-04 5.713E-05 9.501E-06 9.583E-06 9.708E-06 2.233E-05 2.375E-05 2.640E-05 2.450E-06 GI-Lli 1.171E-04 1.168&-04 1.167E-04 1.170E-04 5.435E-05 9.065E-06 9.048E-06 9.062E-06 2.1 17E-05 2.114E-05 2.1 14E-05 9.531E-07 Skin 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+00 0.OOOE+O0 0.OOOE+00 Maximum Dose by Organ:

1.

Maximum Organ Dose (mRem):

7.35(

Maximum Total Body Dose (mRem):

1.16E Maximum Individual NG Dose Summary 170E-04 1.170E-04 1.168E-04 7.350E-04 1.169E-04 1.264E-04 1.171E-04 O.OOOE+O0

)E-04 3E-04 Gas Receptor Location SE Nearest Res 1.52 mi 142 deg SE Visitor SSW Near Gard 4.4 mi 207 deg WSW Near Milk 3.43 mi 248 deg Gamma (mRad) 2.489E-03 1.078E-03 1.888E-04 3.352E-04 Beta (mRad) 1.946E-03 8.426E-04 1.476E-04 2.620E-04 Total Body (mRem) 2.334E-03 1.011E-03 1.771E-04 3.143E-04 Skin (mRem) 4.027E-03 1.743E-03 3.055E-04 5.422E-04 Maximum NG Dose:

2.489E-03 1.946E-03 2.334E-03 4.027E-03 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Gas Status Summary Report Wednesday, March 6, 2013 15:06 Page 6 of 7 Period:

Ann, 2011 Site/Unit/Discharge Point:

PSL1 Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor Agegroup Bone Liver Total Body NW Site Boundary - In Infant 2.899E-01 2.970E-01 2.967E-01 WNW Site Boundary - I Infant 5.936E-05 5.936E-05 5.936E-05 Maximum Doserate by Organ:

2.899E-01 2.970E-01 2.967E-01 Thyroid 3.042E-01 5.936E-05 3.042E-01 Kidney 3.775E-02 5.936E-05 3.775E-02 Lung 2.967E-01 5.936E-05 2.967E-01 GI-Ili 2.966E-01 5.936E-05 2.966E-01 Skin O.OOOE+00 O.OOOE+00 O.OOOE+00 Maximum Organ Doserate (mRem/yr):

Maximum Total Body Doserate (mRem/yr):

3.042E-01 2.967E-01 Site Boundary NG Doserate Summary Gas Receptor Location NW Site Boundary WNW Site Boundary Maximum NG Dose Rate:

Gamma (mRad/yr)

Beta (mRad/yr) 4.443E-03 3.125E-03 3.828E-03 2.692E-03 4.443E-03 3.125E-03 Total Body (mRem/yr) 4.190E-03 3.609E-03 4.190E-03 Skin (mRem/yr) 7.121E-03 6.134E-03 7.121E-03 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Gas Status Summary Report Wednesday, March 6, 2013 15:06 Page 7 of 7 Gas Status Summary Report Wednesday, March 6, 2013 15:06 Page 7 of 7 Period:

Ann, 2011 Site/Unit/Discharge Point:

PSL1 Maximum Individual NNG Dose Summary - Note: All Doses in mRem Receptor SE Nearest Res - Adult SE Nearest Res -

SE Nearest Res -

SE Nearest Res -

SE Visitor - Adult SSW Near Garden SSW Near Garden SSW Near Garden WSW Near Milk -

WSW Near Milk -

WSW Near Milk -

Child Infant Teenager

- Adult

- Child Adult Child Infant Agegroup Adult Child Infant Teenager Adult Adult Child Teenager Adult Child Infant Teenager Bone 9.923E-05 9.922E-05 9.918E-05 9.917E-05 4.608E-05 7.686E-06 7.685E-06 7.681E-06 1.985E-05 2.646E-05 3.597E-05 3.705E-06 Liver 9.923E-05 9.922E-05 9.921E-05 9.922E-05 4.608E-05 7.685E-06 7.685E-06 7.685E-06 2.063E-05 2.624E-05 3.828E-05 5.053E-06 Total Body 9.912E-05 9.909E-05 9.907E-05 9.910E-05 4.603E-05 7.678E-06 7.676E-06 7.676E-06 1.960E-05 1.937E-05 1.971E-05 1.942E-06 Thyroid 1.163E-04 1.264E-04 1.243E-04 1.208E-04 5.351E-05 8.853E-06 9.546E-06 9.165E-06 8.716E-05 2.257E-04 5.144E-04 1.058E-04 Kidney 9.921E-05 9.911E-05 9.906E-05 9.921E-05 4.607E-05 7.684E-06 7.677E-06 7.684E-06 1.902E-05 1.910E-05 1.909E-05 1.698E-06 Lung 1.049E-04 1.060E-04 1.047E-04 1.076E-04 4.857E-05 8.076E-06 8.147E-06 8.257E-06 1.875E-05 1.949E-05 2.071E-05 1.651E-06 GI-Ili 9.936E-05 9.915E-05 9.907E-05 9.932E-05 4.613E-05 7.694E-06 7.680E-06 7.691E-06 1.792E-05 1.790E-05 1.790E-05 7.743E-07 Skin

0. 000E+00 0.000E+00 O.000E+00 0.OOOE+00 0.OOOE+00 0.000E+00 0.OOOE+00 0.000E+00 0.000E+00 O.000E+00 0.000E+00 0.000E+00 WSW Near Milk - Teenager Maximum Dose by Organ:

9.

Maximum Organ Dose (mRem):

5.141 Maximum Total Body Dose (mRem):

9.91ý Maximum Individual NG Dose Summary 923E-05 9.923E-05 9.912E-05 5.144E-04 9.921E-05 1.076E-04 9.936E-05 O.O00E+00

  • E-04 2E-05 Gas Receptor Location SE Nearest Res 1.52 mi 142 deg SE Visitor SSW Near Gard 4.4 mi 207 deg WSW Near Milk 3.43 mi 248 deg Gamma (mRad) 1.978E-03 8.563E-04 1.500E-04 2.663E-04 Beta (mRad) 1.391E-03 6.023E-04 1.055E-04 1.873E-04 Total Body (mRem) 1.865E-03 8.074E-04 1.415E-04 2.511E-04 Skin (mRem) 3.170E-03 1.372E-03 2.405E-04 4.268E-04 Maximum NG Dose:

1.978E-03 1.391E-03 1.865E-03 3.170E-03 User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Gas Status Summarv Reoort Wednesday, March 6, 2013 15:05 Page 7 of 8 Period:

Ann, 2011 Site/Unit/Discharge Point:

PSL2 Site Boundary NNG Doserate Summary - Note: All Doses in mRem/yr Receptor Agegroup Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin NW Site Boundary - In Infant 2.449E-01 2.494E-01 2.492E-01 2.524E-01 3.109E-02 2.492E-01 2.491E-01 0.OOOE+00 WNW Site Boundary - I Infant 9.359E-06 9.359E-06 9.359E-06 9.359E-06 9.359E-06 9.359E-06 9.359E-06 0.OOOE+00 Maximum Doserate by Organ:

2.449E-01 2.494E-01 2.492E-01 2.524E-01 3.109E-02 2.492E-01 2.491E-01 O.OOOE+00 Maximum Organ Doserate (mRem/yr):

2.524E-01 Maximum Total Body Doserate (mRem/yr):

2.492E-01 Site Boundary NG Doserate Summary Gas Receptor Location Gamma (mRad/yr)

Beta (mRad/yr)

Total Body (mRem/yr)

Skin (mRem/yr)

NW Site Boundary 1.149E-03 1.247E-03 1.055E-03 1.925E-03 WNW Site Boundary 9.901E-04 1.074E-03 9.086E-04 1.659E-03 Maximum NG Dose Rate:

1.149E-03 1.247E-03 1.055E-03 1.925E-03 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Gas Status Summary Report Wednesday, March 6, 2013 15:05 Page 8 of 8 Period:

Ann, 2011 Site/Unit/Discharge Point:

PSL2 Maximum Individual NNG Dose Summary - Note: All Doses in mRem Receptor SE Nearest Res - Adult SE Nearest Res - Child SE Nearest Res - Infant SE Nearest Res - Teenager SE Visitor - Adult SSW Near Garden - Adult SSW Near Garden - Child SSW Near Garden -

WSW Near Milk - Adult WSW Near Milk - Child WSW Near Milk - Infant WSW Near Milk - Teenager Agegroup Adult Child Infant Teenager Adult Adult Child Teenager Adult Child Infant Teenager Bone 1.775E-05 1.776E-05 1.774E-05 1.773E-05 8.239E-06 1.374E-06 1.375E-06 1.373E-06 5.306E-06 1.205E-05 2.173E-05 3.768E-06 Liver 1.774E-05 1.775E-05 1.774E-05 1.775E-05 8.238E-06 1.374E-06 1.374E-06 1.374E-06 6.089E-06 1.178E-05 2.398E-05 5.077E-06 Total Body 1.771E-05 1.767E-05 1.766E-05 1.769E-05 8.221E-06 1.371E-06 1.369E-06 1.370E-06 5.075E-06 4.614E-06 4.715E-06 1.833E-06 Thyroid 2.027E-05 2.104E-05 2.075E-05 2.071E-05 9.340E-06 1.547E-06 1.600E-06 1.577E-06 3.393E-05 9.366E-05 2.205E-04 4.660E-05 Kidney 1.770E-05 1.767E-05 1.766E-05 1.770E-05 8.217E-06 1.371E-06 1.369E-06 1.371E-06 4.285E-06 4.357E-06 4.355E-06 1.477E-06 Lung 1.848E-05 1.865E-05 1.849E-05 1.887E-05 8.560E-06 1.424E-06 1.436E-06 1.45 1E-06 3.580E-06 4.260E-06 5.695E-06 7.990E-07 GI-Lli 1.770E-05 1.767E-05 1.766E-05 1.769E-05 8.217E-06 1.371E-06 1.368E-06 1.370E-06 3.249E-06 3.240E-06 3.242E-06 1.788E-07 Skin O.OOOE+00 O.OOOE+00 o.OooE+00 O.OOOE+00 O.OOOE+00 O.OOOE+00 o.OooE+00 0.000E+00 0.OOOE+00 0.OOOE+00 O.OOOE+00 O.OOOE+00 Maximum Dose by Organ:

2 Maximum Organ Dose (mRem):

2.20!

Maximum Total Body Dose (mRem):

1.77:

Maximum Individual NG Dose Summary

.173E-05 2.398E-05 1.771E-05 2.205E-04 1.770E-05 1.887E-05 1.770E-05 0.OOOE+00 5E-04 IE-05 Gas Receptor Location SE Nearest Res 1.52 mi 142 deg SE Visitor Gamma (mRad)

Beta (mRad) 5.116E-04 5.550E-04 2.215E-04 2.403E-04 Total Body (mRem) 4.694E-04 2.033E-04 3.561E-05 6.322E-05 Skin (mRem) 8.570E-04 3.711E-04 6.501E-05 1.154E-04 SSW Near Gard 4.4 mi 207 deg WSW Near Milk 3.43 mi 248 deg 3.881E-05 6.889E-05 4.211E-05 7.474E-05 Maximum NG Dose:

5.116E-04 5.550E-04 4.694E-04 8.570E-04 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

xiEfletMmgntSofwr Page 1 of 1 Friday, February 22, 2013 10:27:48AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec El - Doses to a member of the public due to Liquid Releases Unit: Site Starting: 1-Jan-2011 Ending: 31-Dec-2011 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 2.67E-03 2ND Quarter 2.53E-02 3RD Quarter 1.12E-02 4TH Quarter 1.76E-02 Annual 5.68E-02 Liver mRem 1.15E-02 1.12E-01 4.43E-02 6.24E-02 2.30E-01 Limit mRem Percent of Limit Total Body mRem 3.39E-03 2.99E-02 1.32E-02 1.99E-02 6.64E-02 Limit mRem Percent of Limit Thyroid mRem 3.55E-04 4.01E-04 2.16E-03 5.45E-03 8.36E-03 Limit mRem Percent of Limit Kidney mRem 3.66E-04 3.63E-04 1.60E-03 3.49E-03 5.82E-03 Limit mRem Percent of Limit Lung mRem 1.30E-02 1.28E-01 5.07E-02 7.14E-02 2.63E-01 Limit mRem Percent of Limit GI-Lli mRem 9.83E-03 5.30E-02 3.17E-02 4.23E-02 1.37E-01 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

...n...

EMS Page 1 of 1 Friday, February 22, 2013 10:24:29AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec El - Doses to a member of the public due to Liquid Releases Unit: PSL1 Starting: l-Jan-2011 Ending: 31-Dec-2011 Ogan Dose Bone Limit Units mRem mRem 1ST Quarter 1.34E-03 2ND Quarter 1.26E-02 3RD Quarter 5.61E-03 4TH Quarter 8.81E-03 Annual 2.84E-02 Percent of Limit Liver mRem 5.73E-03 5.59E-02 2.22E-02 3.12E-02 1.15E-01 Limit mRem Percent of Limit Total Body mRem 1.69E-03 1.50E-02 6.60E-03 9.93E-03 3.32E-02 Limit mRem Percent of Limit Thyroid mRem 1.78E-04 2.OOE-04 1.08E-03 2.72E-03 4.18E-03 Limit mRem Percent of Limit Kidney mRem 1.83E-04 1.82E-04 8.02E-04 1.75E-03 2.91E-03 Limit mRem Percent of Limit Lung mRem 6.52E-03 6.41E-02 2.53E-02 3.57E-02 1,32E-01 Limit mRem Percent of Limit GI-Lli mRem 4.92E-03 2.65E-02 1.59E-02 2.11E-02 6.84E-02 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

iEMS Page 1 of 1 Friday, February 22, 2013 10:25:02AM Florida Power & Light St. Lucie Power Plant Reg. Guide 1.21, App B, Sec El - Doses to a member of the public due to Liquid Releases Unit: PSL2 Starting: 1-Jan-2011 Ending: 31-Dec-2011 Ogan Dose Bone Limit Percent of Limit Units mRem mRem 1ST Quarter 1.34E-03 2ND Quarter 1.26E-02 3RD Quarter 5.61E-03 4TH Quarter 8.81E-03 Annual 2.84E-02 Liver mRem 5.73E-03 5.59E-02 2.22E-02 3.12E-02 1.15E-01 Limit mRem Percent of Limit Total Body mRem 1.69E-03 1.50E-02 6.60E-03 9.93E-03 3.32E-02 Limit mRem Percent of Limit Thyroid mRem 1.78E-04 2.OOE-04 1.08E-03 2.72E-03 4.18E-03 Limit mRem Percent of Limit Kidney mRem 1.83E-04 1.82E-04 8.02E-04 1.75E-03 2.91E-03 Limit mRem Percent of Limit, Lung mRem 6.52E-03 6.41E-02 2.53E-02 3.57E-02 1.32E-01 Limit mRem Percent of Limit GI-Lli mRem 4.92E-03 2.65E-02 1.59E-02 2.11E-02 6.84E-02 Limit mRem Percent of Limit User: Al Locke

[Server]: PSLSA37 [Database]: NEPSOEMP

Liquid Status Summary Report Wednesday, March 6, 2013 15:06 Page 6 of 6 Period:

Ann, 2011 Site/Unit/Discharge Point:

PSL1 Liquid Dose Summary - Note: All Doses in mRem Receptor AoearouD Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin Liquid Receptor - Teenager Teenager 2.839E-02 1.150E-01 3.319E-02 3.393E-03 2.912E-03 1.316E-01 6.843E-02 O.OOOE+00 Liquid Recptor - Child Child 1.502E-02 5.340E-02 1.750E-02 4.182E-03 1.262E-03 6.085E-02 3.216E-02 O.OOOE+00 Maximum Dose by Organ:

2.839E-02 1.316E-01 3.319E-02 1.150E-01 3.319E-02 4.182E-03 2.912E-03 1.316E-01 6.843E-02 O.OOOE+O0 Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Liquid Status Summary Report Wednesday, March 6, 2013 15:07 Page 6 of 6 Period:

Ann, 2011 Site/Unit/Discharge Point:

PSI_2 Liquid Dose Summary - Note: All Doses in mRem Receptor AgegrouD Bone Liver Total Body Thyroid Kidney Luna GI-LiI Skin Liquid Receptor -Teenager Teenager 2.839E-02 1.150E-01 3.319E-02 3.393E-03 2.912E-03 1.316E-01 6.843E-02 O.OOOE+00 Liquid Recptor - Child Child 1.502E-02 5.340E-02 1.750E-02 4.182E-03 1.262E-03 6.085E-02 3.216E-02 O.OOOE+O0 Maximum Dose by Organ:

2.839E-02 1.150E-01 3.319E-02 4.182E-03 2.912E-03 1.316E-01 6.843E-02 O.OOOE+00 Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

1.316E-01 3.319E-02 User: Al Locke

[Server]: PSLSA37

[Database]: NEPSOEMP

Wednesday, March 6, 2013 15:10 Liquid Status Summary Report Page 6 of 6 Period:

Ann, 2011 Site/Unit/Discharge Point:

Site Liquid Dose Summary - Note: All Doses in mRem Receptor AoearouD Bone Liver Total Body Thyroid Kidney Lung GI-Lli Skin Liquid Receptor - Teenager Teenager 5.679E-02 2.300E-01 6.638E-02 6.786E-03 5.823E-03 2.632E-01 1.369E-01 O.OOOE+00 Liquid Recptor - Child Child 3.003E-02 1.068E-01 3.500E-02 8.364E-03 2.524E-03 1.217E-01 6.432E-02 O.OOOE+00 Maximum Dose by Organ:

5.679E-02 2.300E-01 6.638E-02 8.364E-03 5.823E-03 2.632E-01 1.369E-01 O.OOOE+00 Maximum Organ Dose (mRem):

Maximum Total Body Dose (mRem):

2.632E-01 6.638E-02 User: AI Locke

[Server]: PSLSA37 [Database]: NEPSOEMP