MONTHYEARL-23-207, License Amendment Request (LAR) for Adoption of TSTF-264-A Revision 0, 3.3.9 and 3.3.10 - Delete Flux Monitors Specific Overlap Requirement SRs2024-01-24024 January 2024 License Amendment Request (LAR) for Adoption of TSTF-264-A Revision 0, 3.3.9 and 3.3.10 - Delete Flux Monitors Specific Overlap Requirement SRs L-24-017, 30-Day Voluntary Report in Accordance with Industry Groundwater Protection Initiative2024-01-24024 January 2024 30-Day Voluntary Report in Accordance with Industry Groundwater Protection Initiative L-23-171, CFR 50.55a Request Number VR-9. Revision 0, Feedwater Check Valve Exercising Test Frequency2023-12-0808 December 2023 CFR 50.55a Request Number VR-9. Revision 0, Feedwater Check Valve Exercising Test Frequency L-23-244, Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation2023-12-0606 December 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation L-23-238, Mid-Cycle Revision to the Core Operating Limits Report for Operating Cycle 202023-11-10010 November 2023 Mid-Cycle Revision to the Core Operating Limits Report for Operating Cycle 20 L-23-052, Submittal of the Updated Safety Analysis Report, Revision 232023-10-27027 October 2023 Submittal of the Updated Safety Analysis Report, Revision 23 L-23-206, Ohio National Pollutant Discharge Elimination System (NPDES) Permit 3IB00016 MD2023-09-12012 September 2023 Ohio National Pollutant Discharge Elimination System (NPDES) Permit 3IB00016 MD L-23-205, Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-09-12012 September 2023 Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-172, Quality Assurance Program Manual2023-08-31031 August 2023 Quality Assurance Program Manual L-23-001, License Amendment Request to Remove the Table of Contents from the Technical Specifications2023-08-0707 August 2023 License Amendment Request to Remove the Table of Contents from the Technical Specifications L-23-188, Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments2023-08-0707 August 2023 Energy Harbor Nuclear Corp., Supplement to Application for Order Consenting to Transfer of Licenses and Conforming License Amendments L-23-174, 30-Day Voluntary Report in Accordance with Industry Groundwater Protection Initiative2023-07-19019 July 2023 30-Day Voluntary Report in Accordance with Industry Groundwater Protection Initiative L-23-146, License Renewal Application for the Perry Nuclear Power Plant2023-07-0303 July 2023 License Renewal Application for the Perry Nuclear Power Plant L-23-051, Plan, Nineteenth Inservice Inspection Summary Report2023-06-22022 June 2023 Plan, Nineteenth Inservice Inspection Summary Report L-23-050, 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models2023-06-22022 June 2023 2022 Annual 10 CFR 50.46 Report of Changes to or Errors in Emergency Core Cooling System Evaluation Models L-22-249, License Amendment Request for Adoption of Technical Specification Task Force Traveler TSTF-276-A Revision 2, Change TS 3.8.1. AC Sources-Operating. to Clarify the Power Factor Requirements When Performing Diesel Gener2023-06-0505 June 2023 License Amendment Request for Adoption of Technical Specification Task Force Traveler TSTF-276-A Revision 2, Change TS 3.8.1. AC Sources-Operating. to Clarify the Power Factor Requirements When Performing Diesel Gener L-23-134, Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations2023-05-23023 May 2023 Response to NRC Regulatory Issue Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations L-23-065, Annual Financial Report2023-05-22022 May 2023 Annual Financial Report L-23-121, Annual Radiological Effluent Release Report2023-04-26026 April 2023 Annual Radiological Effluent Release Report L-23-122, Annual Radiological Environmental Operating Report2023-04-26026 April 2023 Annual Radiological Environmental Operating Report L-23-061, Submittal of the Decommissioning Funding Status Reports2023-03-31031 March 2023 Submittal of the Decommissioning Funding Status Reports L-23-049, Core Operating Limits Report for Operating Cycle 202023-03-30030 March 2023 Core Operating Limits Report for Operating Cycle 20 L-23-037, and Perry Nuclear Power Plant - Independent Spent Fuel Storage Installation Changes, Tests, and Experiments2023-03-29029 March 2023 and Perry Nuclear Power Plant - Independent Spent Fuel Storage Installation Changes, Tests, and Experiments L-23-066, Annual Notification of Property Insurance Coverage2023-03-21021 March 2023 Annual Notification of Property Insurance Coverage L-23-085, 1 to Emergency Plan2023-03-10010 March 2023 1 to Emergency Plan L-23-057, Energy Harbor Nuclear Corp Retrospective Premium Guarantee2023-02-20020 February 2023 Energy Harbor Nuclear Corp Retrospective Premium Guarantee L-23-017, Mid-Cycle Revisions to the Core Operating Limits Report for Operating Cycle 192023-01-31031 January 2023 Mid-Cycle Revisions to the Core Operating Limits Report for Operating Cycle 19 L-22-271, Emergency Plan2022-12-20020 December 2022 Emergency Plan L-22-272, Supplement to License Amendment Request to Revise the Methodology Used for Flood Hazard Analysis (EPID L-2021-LLA-0067) and Withdrawal of Exemption Requests (EPIDs L-2021-LLE-0022 and L-2021-LLE-0023)2022-12-16016 December 2022 Supplement to License Amendment Request to Revise the Methodology Used for Flood Hazard Analysis (EPID L-2021-LLA-0067) and Withdrawal of Exemption Requests (EPIDs L-2021-LLE-0022 and L-2021-LLE-0023) L-22-263, Spent Fuel Storage Cask Registration2022-12-12012 December 2022 Spent Fuel Storage Cask Registration L-22-254, Emergency Plan for Perry Nuclear Power Plant, Including EAL Matrix Revision 222022-11-18018 November 2022 Emergency Plan for Perry Nuclear Power Plant, Including EAL Matrix Revision 22 L-22-250, Mid-Cycle Revision to the Core Operating Limits Report for Operating Cycle 192022-11-0808 November 2022 Mid-Cycle Revision to the Core Operating Limits Report for Operating Cycle 19 L-22-221, Supplement to Application to Revise the Technical Specifications to Adopt TSTF-541, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position2022-10-18018 October 2022 Supplement to Application to Revise the Technical Specifications to Adopt TSTF-541, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position L-22-201, Submittal of Evacuation Time Estimates2022-09-12012 September 2022 Submittal of Evacuation Time Estimates L-22-050, Summary of Changes to the Energy Harbor Nuclear Corp. Quality Assurance Program Manual2022-08-0909 August 2022 Summary of Changes to the Energy Harbor Nuclear Corp. Quality Assurance Program Manual L-20-239, Application to Revise the Technical Specifications to Adopt TSTF-541, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position2022-08-0505 August 2022 Application to Revise the Technical Specifications to Adopt TSTF-541, Add Exceptions to Surveillance Requirements for Valves and Dampers Locked in the Actuated Position L-22-171, Response to Request for Additional Information Regarding Proposed Inservice Inspection Alternative IR-0632022-07-14014 July 2022 Response to Request for Additional Information Regarding Proposed Inservice Inspection Alternative IR-063 L-22-099, Supplement to License Amendment Request to Revise the Methodology Used for Flood Hazard Analysis2022-06-0101 June 2022 Supplement to License Amendment Request to Revise the Methodology Used for Flood Hazard Analysis L-22-104, Annual Radiological Environmental Operating Report2022-04-28028 April 2022 Annual Radiological Environmental Operating Report L-22-110, Response to Request for Additional Information Re 10CFR50.55a Request Number VR-12, Revision 0, Request for Relief from Containment Isolation Valve ASME OM Code Requirement2022-04-28028 April 2022 Response to Request for Additional Information Re 10CFR50.55a Request Number VR-12, Revision 0, Request for Relief from Containment Isolation Valve ASME OM Code Requirement L-22-105, Annual Radiological Effluent Release Report2022-04-27027 April 2022 Annual Radiological Effluent Release Report L-22-082, Response to NRC Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations2022-03-23023 March 2022 Response to NRC Regulatory Issue Summary 2022-01, Preparation and Scheduling of Operator Licensing Examinations L-22-056, Energy Harbor Nuclear Corp., Annual Notification of Property Insurance Coverage2022-03-22022 March 2022 Energy Harbor Nuclear Corp., Annual Notification of Property Insurance Coverage L-22-052, Deviation from BWRVIP-42 Revision 1-A, BWR Vessel and Internals Project, Low Pressure Coolant Injection (LPCI) Coupling Inspection and Flaw Evaluation Guidelines2022-03-16016 March 2022 Deviation from BWRVIP-42 Revision 1-A, BWR Vessel and Internals Project, Low Pressure Coolant Injection (LPCI) Coupling Inspection and Flaw Evaluation Guidelines L-22-073, Submittal of the Decommissioning Funding Status Report for Perry Nuclear Power Plant2022-03-16016 March 2022 Submittal of the Decommissioning Funding Status Report for Perry Nuclear Power Plant L-22-023, Retrospective Premium Guarantee2022-02-17017 February 2022 Retrospective Premium Guarantee L-21-280, 10 CFR 50.55a Request Number VR-12, Revision 0, Request for Relief from Containment Isolation Valve ASME OM Code Requirements2022-01-0505 January 2022 10 CFR 50.55a Request Number VR-12, Revision 0, Request for Relief from Containment Isolation Valve ASME OM Code Requirements L-21-282, Proposed Inservice Inspection Alternative IR-0632022-01-0505 January 2022 Proposed Inservice Inspection Alternative IR-063 L-21-259, 10 CFR 50.55a Requests Number VR-10 and VR-11, Inservice Valve Testing2021-12-28028 December 2021 10 CFR 50.55a Requests Number VR-10 and VR-11, Inservice Valve Testing L-21-287, Submittal of Revision 22 to Updated Safety Analysis Report (Supplement Letter)2021-12-20020 December 2021 Submittal of Revision 22 to Updated Safety Analysis Report (Supplement Letter) 2024-01-24
[Table view] |
Text
FENOC Perry Nuclear Power Station 10 Center Road FirstEnergyNuclear OperatingCompany Perry, Ohio 44081 Mark B. Bezilla 440-280-5382 Vice President Fax: 440-280-8029 September 15, 2009 L-09-238 10 CFR 50.55a ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Perry Nuclear Power Plant Docket No. 50-440, License No. NPF-58 Update to 10 CFR 50.55a Request VR-1 (TAC No. ME01 93)
By correspondence dated November 18, 2008 (Accession No. ML083370198),
FirstEnergy Nuclear Operating Company (FENOC) submitted to the Nuclear Regulatory Commission (NRC) eight separate proposed alternatives to requirements associated with the Perry Nuclear Power Plant Inservice Testing Program.
During teleconferences on August 25 and 27, 2009, FENOC and NRC staff discussed information needed to complete the review of 10 CFR 50.55a Request VR-1. Enclosed is Request VR-1, updated as discussed during the teleconferences. Revision bars in the margin indicate areas of change.
There are no regulatory commitments contained in this submittal. If there are any questions, or additional information is required, please contact Mr. Thomas A. Lentz, Manager- Fleet Licensing, at (330) 761-6071.
Sincerely, /
Mark B. Bezilla
Enclosure:
10 CFR 50.55a Request VR-1, Revision 0 cc: NRC Region III Administrator NRC Resident Inspector NRC Project Manager
Perry Nuclear Power Plant Unit 1 10 CFR 50.55a Request Number VR-1, Revision 0 Page 1 of 3 Proposed Alternative in Accordance with 10 CFR 50.55a(a)(3)(i)
--Alternative Provides Acceptable Level of Quality and Safety--
- 1. ASME Code Component(s) Affected Category B Valves (Typical of 177) 1C11-126, Scram Inlet Valve (Class 2) 1C11-127, Scram Exhaust Valve (Class 2)
Category C Valves (Typical of 177) 1C11-114, Scram Discharge Header Check Valve (Class 2)
[OPEN direction only]
1C1 1-115, Charging Water Check Valve (Class 2)
[OPEN direction only]
These valves operate as an integral part of their respective hydraulic control unit to rapidly insert the control rods in support of a scram function.
2. Applicable Code Edition and Addenda
ASME OM Code-2001, with Addenda through OMb-2003
- 3. Applicable Code Requirements ISTC-3510, "Exercise Test Frequency," requires active Category B and Category C check valves to be exercised nominally every 3 months. If exercising every 3 months is not possible then exercising may be performed during cold shutdowns or refueling outages as permitted by ISTC-3520.
ISTC-5130, "Pneumatically Operated Valves," requires active valves to have their stroke times measured when exercised in accordance with ISTC-3500.
ISTC-5220, '"Check Valves," requires that necessary valve obturator to be demonstrated by performing both an open and close test.
Page 2 of 3
4. Reason for Request
These valves are not provided with position indication; therefore measuring their full stroke time in accordance with the code is impractical.
Exercising these valves at a frequency other than that specified by Technical Specifications could result in a plant trip, which is burdensome without a compensating increase in the level of quality and safety. Additionally, since the power operated valves are not provided with position indication, special test methods or test equipment would be required to determine valve position, which is also burdensome without a compensating increase in the level of quality and safety.
- 5. Proposed Alternative and Basis for Use As discussed in NUREG-1482, Rev.1, Section 4.4.6, the rod scram test frequency identified in the plant Technical Specifications may be used as the valve testing frequency to minimize rapid reactivity transients and unnecessary wear of the CRD mechanisms. Verifying that the associated control rod meets the scram insertion time limits defined in the Technical Specifications can be an acceptable alternative method of detecting degradation of these valves in lieu of valve stroke measurement.
Technical Specification Surveillance Requirement (SR) 3.1.4.1 requires the scram time for all control rods to be verified within limits prior to thermal power exceeding 40% of rated thermal power after fuel movement, and prior to thermal power exceeding 40% of rated thermal power after each reactor shutdown Ž120 days. In addition, Technical Specification SR 3.1.4.2 requires testing of a representative sample of the control rods at least once per 120 days of operation in Mode 1. The Technical Specification SRs assure the necessary quality of the system and components are maintained, and that facility operation will be within the Safety Limits and the Limiting Condition of Operation will be met. Therefore, scram insertion timing per Technical Specification SR 3.1.4.1 shall be substituted for individual valve testing, Using the provisions of this relief request as an alternative to the requirements of ISTC-3510, 5130 and 5220 provides a reasonable alternative to the code requirements. The proposed alternative method of detecting degradation provides reasonable assurance of the valves' operational readiness. Therefore, the proposed alternative provides an acceptable level of quality and safety, and Perry Nuclear Power Plant (PNPP) requests that relief be granted pursuant to 10 CFR 50.55a(a)(3)(i).
Page 3 of 3
- 6. Duration of Proposed Alternative The proposed alternative identified in this relief request shall be utilized during the Third Ten-Year IST Interval.
- 7. Precedent Perry Nuclear Power Plant, Docket No. 50-440, Safety Evaluation Report (SER) dated August 9, 1999, "Safety Evaluation of the Inservice Testing Program Second Ten-Year Interval for Pumps and Valves - Perry Nuclear Power Plant, (TAC No. MA3328)." Previously approved as VR-1 in the aforementioned SER.
- 8. References
- 1. Technical Specification SR 3.1.4.1, Control Rod Scram Times.
- 2. Technical Specification SR 3.1.4.2, Control Rod Scram Times.
- 3. NUREG-1482, Guidelines for Inservice Testing at Nuclear Power Plants, Revision 1, January 2005, Section 4.4.6, Testing Individual Scram Valves for Control Rods in Boiling-Water Reactors.,
- 4. Refueling Outage Justification RO-31, Control Rod Drive Hydraulic System (Cl1), Valve 1C11-115.