L-09-168, Emergency Response Data System Data Point Library Update
| ML091810056 | |
| Person / Time | |
|---|---|
| Site: | Beaver Valley |
| Issue date: | 06/25/2009 |
| From: | Sena P FirstEnergy Nuclear Operating Co |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| L-09-168 | |
| Download: ML091810056 (177) | |
Text
FENOC FirstEnergy Nuclear Operating Company Beaver Valley Power Station P.O. Box 4 Shippingport, PA 15077 Peter P. Sena III Site Vice President 724-682-5234 Fax: 724-643-8069 June 25, 2009 L-09-168 10 CFR 50, Appendix E,Section VI ATTN: Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555-0001
SUBJECT:
Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Emeraencv ResDonse Data System Data Point Library Update i J if I
J I
In accordance with 10 CFR 50, Appendix E,Section VI, an update of the Emergency Response Data System (ERDS) Data Point Library (DPL) for Beaver Valley Power Station Unit Nos. 1 (BV1) and 2 (BV2) is provided. An attachment provides the details regarding each change. A complete copy of the DPL is enclosed due to the addition of page numbers on each page.
There are no regulatory commitments contained in this submittal. If there are any questions or if additional information is required, please contact Mr. Thomas A. Lentz, Manager-Fleet Licensing, at 330-761-6071.
Sincerely, Peter P. Sena III
Attachment:
Summary of Changes to the Data Point Library (DPL)
Enclosure:
Updated Data Point Library cc:
NRC Region I Administrator NRC Resident Inspector NRC Project Manager (w/o enclosure)
Director BRP/DEP Site BRP/DEP Representative
Attachment L-09-168 Summary of Changes to the Data Point Library (DPL)
Page 1 of 1 Reactor DPL Unit Point Description of Change(s)
BV1*
U1000 Date: Changed to "6/212009" Engr Units/Dig States: Replaced "PSIA" with "PSIG" Minimum Instr Range: Replaced "5" with "-10" Maximum Instr Range: Replaced "70" with "55" BV1 (all)
Added "ERDS Data Point Library (DPL) Index" and BV2 Added page numbers to the bottom of each page of the DPL (A
FOR INTERNAL DISTRIBUTION USE ONLY Internal Distribution of Letter L-09-168 K. J. Nevins P. H. Lashley T. A. Lentz G. H. Halnon B. F. Sepelak C. P. Keller R. K. Brosi D. Minkus R. Cavaliere T. Zyra R. Bologna M. Manoleras C. I. Custer P. P. Sena III J. H. Lash D. W. Jenkins Central File - Keywords: ERDS
Enclosure L-09-168 Updated Data Point Library (173 pages follow)
ERDS Data Point Library (DPL) Index UNIT POINT ID DESCRIPTION BV1 U0400 RCLA UNCORRECTED FLOW 1/2/3 AVG BV1 U0414 SG A STM OUT PRESS 1/2/3 AVG BV1 U0420 RCLB UNCORRECTED FLOW 1/2/3 AVG BV1 U0434 SG B STM OUT PRESS 1/2/3 AVG BV1 C0201A CNMT HYDROGEN CONCENTRATION CH 1 BV1 C0202A CNMT HYDROGEN CONCENTRATION CH 2 BV1 U0440 RCLC UNCORRECTED FLOW 1/2/3 AVG BV1 U0454 SG C STM OUT PRESS 1/2/3 AVG BV1 F0128A CHG PUMP DISCH HDR UNCORR FLOW BV1 F0403A" SG A UNCORR FW 1 FLOW BV1 F0404A SG A UNCORR FW 2 FLOW BV1 F0423A SG B UNCORR FW 1 FLOW BV1 F0424A SG B UNCORR FW 2 FLOW BV1 F0443A SG C UNCORR FW 1 FLOW BV1 F0444A SG C UNCORR FW 2 FLOW BV1 F0601A SG A AUX FEED FLOW BV1 F0602A SG B AUX FEED FLOW BV1 F0603A SG C AUX FEED FLOW BV1 F5940A HHSI TO HOT LEG HDR FLOW BV1 F5943A HHSI TO BIT FLOW BV1 F5945A SI-P-lA DISCHARGE FLOW BV1 F5946A SI-P-1B DISCHARGE FLOW BV1 L0403A SG A WIDE RANGE LEVEL BV1 L0423A SG B WIDE RANGE LEVEL BV1 L0443A SG C WIDE RANGE LEVEL BV1 L0750A RECIRC SUMP WTR LVL 1 BV1 L0751A RECIRC SUMP WTR LVL 2 BV1 L0752A CNMT SUMP WTR LEVEL Thursday, June 04, 2009 PARAMETER CORE-FLOW1 SG-PRESS-1A CORE-FLOW2 SG-PRESS-2B H2-CONC1 EXTRA22 CORE-FLOW3 SG-PRESS-3C RCS-CHG-MU MN-FD-FL-1A EXTRA6 MN-FD-FL-2B EXTRA7 MN-FD-FL-3C EXTRA8 AX-FD-FL-1A AX-FD-FL-2B AX-FD-FL-3C HPSI-FLOW1 HPSI-FLOW2 LPSI-FLOW1 LPSI-FLOW2 SG-LEVEL-1A SG-LEVEL-2B SG-LEVEL-3C CTMNT-SP-WR1 CTMNT-SP-WR2 CNMNT-SP-NR1 PAGE 1-01 1-02 1-03 1-04 1-05 1-06 1-07 1-08 1-09 1-10 1-11 1-12 1-13 1-14 1-15 1-16 1-17 1-18 1-19 1-20 1-21 1-22 1-23 1-24 1-25 1-26 1-27 1-28 Page 1 of 6
UNIT POINT ID DESCRIPTION PARAMETER PAGE BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BVl BV1 BV1 L3204A L3206A L3210A L3212A N0031A N0032A N0035A N0036A N0049A N0050A N0051A N0052A P0498A P0499A P1008A P1009A U0483 U0472 R0029A R0030A R0034A R0036A R0037A R0070A R0071A RWSTLEV T0406A T0419A T0426A T0439A RX VESSEL FULL RANGE LEVEL - A RX VESSEL DYNAMIC LEVEL
- A RX VESSEL FULL RANGE LEVEL - B RX VESSEL DYNAMIC LEVEL
- B SOURCE RANGE DET 1 LOG FLUX SOURCE RANGE DET 2 LOG FLUX INTERMEDIATE RANGE DET 1 LOG FLUX INTERMEDIATE RANGE DET 2 LOG FLUX PWR RNG CHANNEL 1 FLUX (QUAD 4)
PWR RNG CHANNEL 2 FLUX (QUAD 2)
PWR RNG CHANNEL 3 FLUX (QUAD 1).
PWR RNG CHANNEL 4 FLUX (QUAD 3)
RCS LOOP 2 WIDE RANGE PRESS RCS WR PRESSURE WIDE RANGE CNMT PRESS CH 1 WIDE RANGE CNMT PRESS CH 2 PRESSURIZER LEVEL 1/2/3 AVG PRESSURIZER PRESS 1/2/3 AVG CONDENSER AIR EJECTOR LIQUID WASTE EFFLUENT STEAM GENERATOR BLOWDOWN RX COOLANT LETDOWN HI RANGE RX COOLANT LETDOWN LO RANGE CNMT HIGH RANGE RAD MONITOR CH 1 CNMT HIGH RANGE RAD MONITOR CH 2 RWST AVERAGE LEVEL 1/2/3 RCLA WR TCOLD RCLA WR THOT RCLB WR TCOLD RCLB WR THOT REAC-VES-LV1 REAC-VES-LV3 REAC-VES-LV2 REAC-VES-LV4 NI-SOURC-RNG EXTRA5 NI-INTER-RNG EXTRA4 NI-POWER-RNG EXTRAl EXTRA2 EXTRA3 RCS-PRESSURE EXTRA9 CTMNT-PRESS EXTRA21 PRZR-LEVEL EXTRA10 COND-AE-RAD1 EFF-LIQ-RAD1 SG-BD-RAD-1A RCS-LTD-RAD1 RCS-LTD-RAD2 CTMNT-RAD1 CTMNT-RAD2 BWST-LEVEL1 CL-TEMP-1A HL-TEMP-1A CL-TEMP-2B HL-TEMP-2B 1-29 1-30 1-31 1-32 1-33 1-34 1-35 1-36 1-37 1-38 1-39 1-40 1-41 1-42 1-43 1-44 1-45 1-46 1-47 1-48 1-49 1-50 1-51 1-52 1-53 1-54 1-55 1-56 1-57 1-58 Thursday, June 04, 2009 Page 2 of 6
UNIT POINT ID DESCRIPTION PARAMETER PAGE BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BVl BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BV1 BVl BV1 BV1 BV1 BV1 BV2 BV2 T0446A T0459A U1000 U0094 U0093 U1008 Y0705A Y0717A Y0735A XM006 XM026 XM051 XM061 XM083 XM087 XR001 XR002 XR003 XR004 XR005 XR006 XR007 XR009 XR010 XR011 XR013 XR014 XR015 F0400A F0421A RCLC WR TCOLD RCLC WR THOT CONTAINMENT PRESS 1/2/3 AVG SUBCOOL (AVG 5 HI T/C) ICCM AVG IN CORE TIC 5 HOTTEST AVG AVG OF 5 TS CNMT AIR TEMPS COMP COOLING/RECIRC SPRAY HX RW LIQUID WASTE CONTAINMENT DN EFF REACTOR CONTAINMENT L/R WIND SPEED 35' ELEVATION WIND SPEED 500' ELEVATION WIND DIRECTION 150' ELEVATION WIND DIRECTION 500' ELEVATION STABILITY-GROUND LEVEL STABILITY-ELEVATED 1RM-MS-101 1RM-MS-100A 1RM-MS-100B 1RM-MS-100C 1RM-VS-109 CH5 1RM-VS-109 CH7 1RM-VS-109 CH9 CL-TEMP-3C HL-TEMP-3C EXTRA20 SUB-MARGIN1 TMP-CORE-EX1 CTMNT-TEMP EXTRA18 EFF-LIQ-RAD2
'EXTRA19 WIND-SPEED1 WIND-SPEED2 WIND-DIR1 WIND-DIR2 STAB-CLASS1 STAB-CLASS2 EXTRAl1 EXTRA 12 EXTRA13 EXTRA14 EFF-GAS-RAD1 EFF-GAS-RAD2 EFF-GAS-RAD3 1-59 1-60 1-61 1-62 1-63 1-64 1-65 1-66 1-67 1-68 1-69 1-70 1-71 1-72 1-73 1-74 1-75 1-76 1-77 1-78 1-79 1-80 1-81 1-82 1-83 1-84 1-85 1-86 2-01 2-02 1RM-VS-110 CH5 1RM-VS-110 CH7 1RM-VS-110 CH9 1RM-GW-109 CH5 1RM-GW-109 CH7 1RM-GW-109 CH9 RCL A FLW RCL B FLW EFF-GAS-RAD4 EFF-GAS-RAD5 EFF-GAS-RAD6 EXTRA15 EXTRA16 EXTRA 17 RCS-FT414 CORE-FLOW1 RCS-FT425 CORE-FLOW2 Thursday, June 04, 2009 Page 3 of 6
UNIT POINT ID DESCRIPTION PARAMETER PAGE BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 F0442A UPS013 UPS017 UPS014 UPS018 L0100A L0102A L0403A L0423A L0443A L0500A L0501A L0750A L0751A N0031A N0032A N0035A N0036A N0049A N0050A N0051A N0052A R0001A R0002A R0003A R0010A R0079A R0086A R0087A R0088A RCL C FLW RCS-FT436 RVLIS FULL RANGE LEVEL TRAIN A RVLIS DYNAMIC RANGE TRAIN A RVLIS FULL RANGE LEVEL TRAIN B RVLIS DYNAMIC RANGE TRAIN B CNMT SUMP LVL DAS-LT220 CNMT SUMP LVL DAS-LT222 SG 21A WR LVL FWS-LT477 SG 21B WR LVL FWS-LT487 SG 21C WR LVL FWS-LT497 RWST LVL QSS-LT100A RWST LVL QSS-LT100B RX CNMT SUMP LVL RSS-LT151A RX CNMT SUMP LVL RSS-LT151B SOURCE RNG DET 1 FLUX-LOG NM31F SOURCE RNG DET 2 FLUX-LOG NM32F INT RNG DET 1 FLUX-LOG NM35B INT RNG DET 2 FLUX-LOG NM36B PWR RNG CHAN 1 FLUX NM41F PWR RNG CHAN 2 FLUX NM42F PWR RNG CHAN 3 FLUX
,NM43F PWR RNG CHAN 4 FLUX NM44F AIR EJ DISCHARGE 2ARC-RQ100 RX CLNT LTDN LO RNG 2CHS-RQ101A RX CLNT LTDN HI RNG 2CHS-RQ101B AIR EJ DELAY BED 2GWS-RQ102 SG BLOWDOWN 2SSR-RQ100 IN-CNMT HI RNG AREA 2RMR-RQ206 IN-CNMT HI RNG AREA 2RMR-RQ207 MAIN STM ACTIVITY 2MSS-RQ101A CORE-FLOW3 REAC-VES-LV3 REAC-VES-LV1 REAC-VES-LV4 REAC-VES-LV2 CTMNT-SP-NR1 CTMNT-SP-NR2 SG-LEVEL-1A SG-LEVEL-2B SG-LEVEL-3C BWST-LEVEL1 BWST-LEVEL2 CTMNT-SP-WR1 CTMNT-SP-WR2 NI-SOURC-RNG EXTRA5 NI-INTER-RNG EXTRA4 NI-POWER-RNG EXTRAl EXTRA2 EXTRA3 COND-AE-RAD1 RCS-LTD-RAD2 RCS-LTD-RAD 1 COND-AE-RAD2 SG-BD-RAD-1A CTMNT-RAD 1 CTMNT-RAD2 MAIN-SL-1A 2-03 2-04 2-05 2-06 2-07 2-08 2-09 2-10 2-11 2-12 2-13 2-14 2-15 2-16 2-17 2-18 2-19 2-20 2-21 2-22 2-23 2-24 2-25 2-26 2-27 2-28 2-29 2-30 2-31 2-32 Thursday, June 04, 2009 Page 4 o*f'6
UNIT POINT ID DESCRIPTION PARAMETER PAGE BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 R0089A R0090A R0094A T0406A T0419A T0426A T0439A T0446A T0459A T1002A T1008A T1013A T1014A T1015A
-U0410 U0430 U0450 UFlO11 UF1013 UF1014 UF3000 UF3001 UF3002 U0483 UP1000 UPS026 U0414 U0434 U0454 UPS012 MAIN STM ACTIVITY 2MSS-RQ101B MAIN STM ACTIVITY 2MSS-RQ101C LIQ WST EFFLUENT 2SGC-RQ100 RCLA WIDE RANGE TCOLD RCS-TE410 RCL A WIDE RANGE THOT RCS-TE413 RCL B WIDE RANGE TCOLD RCS-TE420 RCL B WIDE RANGE THOT RCS-TE423 RCL C WIDE RANGE TCOLD RCS-TE430 RCL C WIDE RANGE THOT RCS-TE433 RX CNMT TEMP LMS-TE 100-2 RX CNMT TEMP LMS-TE100-8 RX CNMT TEMP LMS-TE100-13 RX CNMT TEMP LMS-TE100-14 RXCNMTTEMP LMS-TE100-15 LOOP A CORR FW FLW AVG 1+2 LOOP B CORR FW FLW AVG 1+2 LOOP C CORR FW FLW AVG 1+2 HI SI FLOW TOTAL TOTAL CHARGING FLOW LO SI FLOW TOTAL AFW FLOW TO SG A AFW FLOW TO SG B AFW FLOW TO SG C AVERAGE PZR LEVEL (1/2/3)
CNMT PRESS AVG RCS WIDE RANGE PRESSURE STM GEN A STM OUT P BELV 1 2+3 STM GEN B STM OUT P BELV 1 2+3 STM GEN C STM OUT P BELV 1 2+3 TSAT MARGIN (SUBCOOLING)
MAIN-SL-2B MAIN-SL-3C EFF-LIQ-RADI CL-TEMP-1A HL-TEMP-1A CL-TEMP-2B HL-TEMP-2B CL-TEMP-3C HL-TEMP-3C CTMNT-TEMP EXTRA12 EXTRA13 EXTRA14 EXTRA 15 MN-FD-FL-1A MN-FD-FL-2B MN-FD-FL-3C HPSI-FLOW1 RCS-CHG-MU LPSI-FLOW1 AX-FD-FL-1A AX-FD-FL-2B AX-FD-FL-3C PRZR-LEVEL CTMNT-PRESS RCS-PRESSURE SG-PRESS-1A SG-PRESS-2B SG-PRESS-3C SUB-MARGIN1 2-33 2-34 2-35 2-36 2-37 2-38 2-39 2-40 2-41 2-42 2-43 2-44 2-45 2-46 2-47 2-48 2-49 2-50 2-51 2-52 2-53 2-54 2-55 2-56 2-57 2-58 2-59 2-60 2-61 2-62 Thursday, June 04, 2009 Page 5 of 6
UNIT POINT ID DESCRIPTION PARAMETER PAGE BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 BV2 UPSool Y0752A Y0753A XM006 XM026 XM051 XM061 XM083 XM087 XRo13 XR014 XR015 XR041 XR042 XR045 XR046 XR053 XR054 XR055 HIGHEST T/C TEMPERATURE CNMT H2 CONC TRN A HCS-HA100A CNMT H2 CONC TRN B HCS-HA100B WIND SPEED 35' ELEVATION WIND SPEED 500' ELEVATION WIND DIRECTION 150' ELEVATION WIND DIRECTION 500' ELEVATION STABILITY-GROUND LEVEL STABILITY-ELEVATED 1RM-GW-109 CH5 1RM-GW-109 CH7 1RM-GW-109 CH9 2HVS-RQI101A TMP-CORE-EX1 H2-CONC1 EXTRA16 WIND-SPEED1 WIND-SPEED2 WIND-DIR1 WIND-DIR2 STAB-CLASS 1 STAB-CLASS2 EXTRA 15 EXTRA16 EXTRA117 EFF-GAS-RADI EFF-GAS-RAD2 EFF-GAS-RAD3 EFF-GAS-RAD4 EXTRA9.
EXTRA10 EXTRA 11 2-63 2-64 2-65 2-66 2-67 2-68 2-69 2-70 2-71 2-72 2-73 2-74 2-75 2-76 2-77 2-78 2-79 2-80 2-81 2HVS-RQI101B 2HVS-RQI109A 2HVS-RQI109 2MSS-RQI101A 2MSS-RQI101B 2MSS-RQI101C Thursday, June 04, 2009 Page 6. ol'b
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CORE-FLOW1 U0400 RCLA UNCORRECTED FLOW 1/2/3 AVG TOTAL REACTOR COOLANT FLOW A
N/A 0
120 N/A N/A P
3 SAVG ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD NO ALARMS IN ANY MODE N/A N/A LOW N
N/A U0400 is the average of three, two or a single flow value depending on the deviation between flow signals. RC-P-1A, B and C each have a design flow rate of 88,500 GPM at 549F and 2235 PSIG. FT-1RC-414, 415 and 416 sense flow at the Reactor Coolant Pipe Elbow between SG A Outlet and Reactor Coolant Pump RC-P-1A. Ref: Op Manual Chapter 6; RM-406-1; RM-406-3.
1-01
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI-Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1
.IPC SG-PRESS-1A U0414 SG A STM OUT PRESS 1/2/3 AVG STEAM GENERATOR A PRESSURE A
PSIG LINEAR 0
1400 N/A N/A P
3 SAVG ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD NO ALARMS IN ANY MODE N/A N/A LOW N
N/A This point provides an average of three, two, or a single steam pressure value depending on the deviation between the values. The Atmospheric Steam Dump Valves open at 1025 PSIG, the Main Steam Safety Valves begin lifting at 1075 PSIG. PT-MS-474, 475 and 476 sense Main Steam Line pressure between the Main Steam Trip Valves and SG A. Ref: Op Manual Chapter 21; RM-421-1 1-02
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CORE-FLOW2 U0420 RCLB UNCORRECTED FLOW 1/2/3 AVG TOTAL REACTOR COOLANT FLOW A
N/A 0
120 N/A N/A P
3 SAVG ALGORITHM SEEf UNIQUE SYSTEM DESCRIPTION FIELD NO ALARMS IN ANY MODE N/A N/A LOW N
N/A U0420 is the average of three, two or a single flow value depending on the deviation between flow signals. RC-P-1A, B and C each have a design flow rate of 88,500 GPM at 549F and 2235 PSIG. FT-1RC-424, 425 and 426 sense flow at the Reactor Coolant Pipe Elbow between SG B Outlet and Reactor Coolant Pump RC-P-1 B. Ref: Op Manual Chapter 6; RM-406-1; RM-406-3.
1-03
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Com pensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC SG-PRESS-2B U0434 SG B STM OUT PRESS 1/2/3 AVG STEAM GENERATOR B PRESSURE A
PSIG LINEAR 0
1400 N/A N/A P
3 SAVG ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD NO ALARMS IN ANY MODE N/A N/A LOW N
N/A This point provides an average of three, two, or a single steam pressure value depending on the deviation between the values. The Atmospheric Steam Dump Valves open at 1025 PSIG, the Main Steam Safety Valves begin lifting at 1075 PSIG. PT-MS-484, 485 and 486 sense Main Steam Line pressure between the Main Steam Trip Valves and SG B. Ref: Op Manual Chapter 21; RM-421-1 1-04
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
4/26/1999 BV1 IPC H2-CONC1
.C0201A CNMT HYDROGEN CONCENTRATION CH 1 CONTAINMENT HYDROGEN CONC A
LINEAR 0
10 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALARM AT 1.0%
N/A N/A LOW N
N/A Containment gas is sampled and analyzed at Hydrogen Analyzer H2-HY101A. Hydrogen concentration is indicated locally and on the main control board. H2-HY101A senses hydrogen concentration alternately, in Stream 1 the Pressurizer Cubicle, then in Stream 2 the suction line for the Containment Evacuation Pump 1A (Containment Dome). Ref: Op Manual Chapter 46, RM-150-1 Alarms valid in Modes 1 thru 4.
1-05
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
4/26/1999 BV1 IPC EXTRA22 C0202A CNMT HYDROGEN CONCENTRATION CH 2 CONTAINMENT HYDROGEN CONC A
LINEAR 0
10 N/A N/A-S 1
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD.
HI ALARM AT 1.0%
N/A N/A LOW N
N/A Containment gas is sampled and analyzed at Hydrogen Analyzer H2-HY101B. Hydrogen concentration is indicated locally and on the main control board. H2-HY1O1B senses hydrogen concentration alternately in Stream 1 the Pressurizer Cubicle, then in Stream 2 the suction line for the Containment Evacuation Pump 1B (Containment Dome). Ref: Op Manual Chapter 46, RM-150-1 Alarms valid in Modes 1 thru 4.
1-06
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CORE-FLOW3 U0440 RCLC UNCORRECTED FLOW 1/2/3 AVG TOTAL REACTOR COOLANT FLOW A
N/A 0
120 N/A N/A P
3 SAVG ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD NO ALARMS IN ANY MODE N/A N/A LOW N
N/A U0440 is the average of three, two or a single flow value depending on the deviation between flow signals. RC-P-1A, B and C each have a design flow rate of 88,500 GPM at 549F and 2235 PSIG. FT-1 RC-434, 435 and 436 sense flow at the Reactor Coolant Pipe Elbow between SG C Outlet and Reactor Coolant Pump RC-P-1C. Ref: Op Manual Chapter 6; RM-406-1; RM-406-3.
1-07
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC SG-PRESS-3C U0454 SG C STM OUT PRESS 1/2/3 AVG STEAM GENERATOR C PRESSURE A
PSIG LINEAR 0
1400 N/A N/A P
3 SAVG ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD NO ALARMS IN ANY MODE N/A N/A LOW N
N/A This point provides an average of three, two, or a single steam pressure value depending on the deviation between the values. The Atmospheric Steam Dump Valves open at 1025 PSIG, the Main Steam Safety Valves begin lifting at 1075 PSIG. PT-MS-494, 495 and 496 sense Main Steam Line pressure between the Main Steam Trip Valves and SG C. Ref: Op Manual Chapter 21; RM-421-1 1-08
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/20/2007 BV1 IPC RCS-CHG-MU F0128A CHG PUMP DISCH HDR UNCORR FLOW PRIMARY SYSTEM CHG OR MU FLOW A
GPM N/A 0
200 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Three Charging Pumps with a rated flow of 150 GPM at 2500 PSIG each provide borated water from the RWST through FCV-1CH-122 to the Reactor Coolant Loops. FT-1CH-122 senses charging flow between the discharge of the Charging Pumps CH-P-1A, B and C and the Regenerative Heat Exchanger. Ref: Op Manual Chapter 7; RM-407-1 LOW ALARM = 20 GPM (Modes 1 and 2); 0 GPM (Modes 3 thru 6)
HI ALARM = 120 GPM (Modes 1 thru 3), 180 GPM (Modes 4 thru 6) 1-09
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/1/2007 BV1 IPC MN-FD-FL-1A F0403A SG A UNCORR FW 1 FLOW STM GEN A MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A FT-1FW-476 provides Main Feed flow indication at the Main Control Board, a signal to PNL-AMSAC and signals to the solid state protection system (SSPS). Two Main Feed Pumps (1FW-P-1A, B) rated at 15200 GPM at 1900 TDH supply feedwater to three Steam Generators. FT-1 FW-476 senses Main Feed flow to SG A between the First Point Feedwater Heater and Feed Regulating Valve (FCV-FW478). Ref: Op Manual Chapter 24; RM-424-1 LOW ALARM = 0 MLB/HR (Modes 1 and 2)
HIGH ALARM = 4.6 MLB/HR (Modes 1 and 2)
Also alarm on redundant tolerance (Modes 1 and 2)
No alarms (Mode 3 thru 6) 1-10
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/1/2007 BV1 IPC EXTRA6 F0404A SG A UNCORR FW 2 FLOW STM GEN A MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A FT-1FW-477 provides Main Feed flow indication at the Main Control Board, a signal to PNL-AMSAC and signals to the solid state protection system (SSPS). Two Main Feed Pumps (1FW-P-1A, B) rated at 15200 GPM at 1900 TDH supply feedwater to three Steam Generators. FT-1FW-477 senses Main Feed flow to SG A between the First Point Feedwater Heater and Feed Regulating Valve (FCV-FW478). Ref: Op Manual Chapter 24; RM-424-1 LOW ALARM = 0 MLB/HR (Modes 1 and 2)
HIGH ALARM = 4.6 MLB/HR (Modes 1 and 2)
Also alarm on redundant tolerance (Modes 1 and 2)
No alarms (Mode 3 thru 6) 1-11
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/1/2007 BV1 IPC MN-FD-FL-2B F0423A SG B UNCORR FW 1 FLOW STM GEN B MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A FT-1FW-486 provides Main Feed flow indication at the Main Control Board, a signal to PNL-AMSAC and signals to the solid state protection system (SSPS). Two Main Feed Pumps (1FW-P-1A, B) rated at 15200 GPM at 1900 TDH supply feedwater to three Steam Generators. FT-1 FW-486 senses Main Feed flow to SGB between the First Point Feedwater Heater and Feed Regulating Valve (FCV-FW488). Ref: Op Manual Chapter 24; RM-424-1 LOW ALARM = 0 MLB/HR (Modes 1 and 2)
HIGH ALARM = 4.6 MLB/HR (Modes 1 and 2)
Also alarm on redundant tolerance (Modes 1 and 2)
No alarms (Mode 3 thru 6) 1-12
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/1/2007 BV1 IPC EXTRA7 F0424A SG B UNCORR FW 2 FLOW STM GEN B MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A FT-1FW-487 provides Main Feed flow indication at the Main Control Board, a signal to PNL-AMSAC and signals to the solid state protection system (SSPS). Two Main Feed Pumps (1FW-P-1A, B) rated at 15200 GPM at 1900 TDH supply feedwater to three Steam Generators. FT-1FW-487 senses Main Feed flow to SG B between the First Point Feedwater Heater and Feed Regulating Valve (FCV-FW488). Ref: Op Manual Chapter 24; RM-424-1 LOW ALARM = 0 MLB/HR (Modes 1 and 2)
HIGH ALARM 4.6 MLB/HR (Modes 1 and 2)
Also alarm on redundant tolerance (Modes 1 and 2)
No alarms (Mode 3 thru 6) 1-13
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NIDetector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/1/2007 BV1 IPC MN-FD-FL-3C F0443A SG C UNCORR FW 1 FLOW STM GEN C MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A FT-IFW-496 provides Main Feed flow indication at the Main Control Board, a signal to PNL-AMSAC and signals to the solid state protection system (SSPS). Two Main Feed Pumps (1FW-P-1A, B) rated at 15200 GPM at 1900 TDH supply feedwater to three Steam Generators. FT-1FW-496 senses Main Feed flow to SG C between the First Point Feedwater Heater and Feed Regulating Valve (FCV-FW498). Ref: Op Manual Chapter 24; RM-424-1 LOW ALARM = 0 MLB/HR (Modes 1 and 2)
HIGH ALARM = 4.6 MLB/HR (Modes 1 and 2)
Also alarm on redundant tolerance (Modes 1 and 2)
No alarms (Mode 3 thru 6) 1-14
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/1/2007 BV1 IPC EXTRA8 F0444A SG C UNCORR FW 2 FLOW STM GEN C MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0 N/A N/A S
I N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A FT-1FW-497 provides Main Feed flow indication at the Main Control Board, a signal to PNL-AMSAC and signals to the solid state protection system (SSPS). Two Main Feed Pumps (1FW-P-1A, B) rated at 15200 GPM at 1900 TDH supply feedwater to three Steam Generators. FT-1 FW-497 senses Main Feed flow to SG C between the First Point Feedwater Heater and Feed Regulating Valve (FCV-FW498). Ref: Op Manual Chapter 24; RM-424-1 LOW ALARM = 0 MLB/HR (Modes 1 and 2)
HIGH ALARM = 4.6 MLB/HR (Modes 1 and 2)
Also alarm on redundant tolerance (Modes 1 and 2)
No alarms (Mode 3 thru 6) 1-15
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC AX-FD-FL-1A F0601A SG A AUX FEED FLOW STM GEN A AUXILIARY FW FLOW A
GPM N/A 0
400 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A Auxiliary Feedwater flow is provided by 1 Steam Driven (700 GPM) pump (1FW-P-2) and 2 Electric Driven (350 GPM) pumps (1FW-P-3A and B) taking suction on Primary Plant Demineralized Storage Tank or River Water System. Auxiliary Feedwater Pump (1FW-P-4) takes suction from the Demineralized Water Storage Tanks (1WT-TK-1 1, 26) and provides 440-700 GPM flow to bring plant to cold shutdown. 1FW-P-4 is required because the 1st 3 pumps do not comply with separation requirements of 10CFR50 APPENDIX R. FT-1FW-100A senses Auxiliary Feedwater to SG A between Auxiliary Feedwater Throttle Valves and SG A. Auxiliary Feedwater Header connects with the Main Feedwater line downstream of the Main Feedwater Isolation Valves.
1-16
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
A larm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC AX-FD-FL-2B F0602A SG B AUX FEED FLOW STM GEN B AUXILIARY FW FLOW A
GPM N/A 0
400 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A Auxiliary Feedwater flow is provided by 1 Steam Driven (700 GPM) pump (1FW-P-2) and 2 Electric Driven (350 GPM) pumps (1FW-P-3A and B) taking suction on Primary Plant Demineralized Storage Tank or River Water System. Auxiliary Feedwater Pump (1FW-P-4) takes suction from the Demineralized Water Storage Tanks (1WT-TK-11, 26) and provides 440-700 GPM flow to bring plant to cold shutdown. 1FW-P-4 is required because the 1st 3 pumps do not comply with separation requirements of 10CFR50 APPENDIX R. FT-1FW-100B senses Auxiliary Feedwater to SG B between Auxiliary Feedwater Throttle Valves and SG B. Auxiliary Feedwater Header connects with the Main Feedwater line downstream of the Main Feedwater Isolation Valves.
1-17
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC AX-FD-FL-3C F0603A SG CAUX FEED FLOW STM GEN C AUXILIARY FW FLOW A
GPM N/A 0
400 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A Auxiliary Feedwater flow is provided by 1 Steam Driven (700 GPM) pump (1FW-P-2) and.2 Electric Driven (350 GPM) pumps (1FW-P-3A and B) taking suction on Primary Plant Demineralized Storage Tank or River Water System. Auxiliary Feedwater Pump (1FW-P-4) takes suction from the Demineralized Water Storage Tanks (1WT-TK-1 1, 26) and provides 440-700 GPM flow to bring plant to cold shutdown. 1 FW-P-4 is required because the 1st 3 pumps do not comply with separation requirements of 10CFR50 APPENDIX R. FT-1FW-100C senses Auxiliary Feedwater to SG C between Auxiliary Feedwater Throttle Valves and SG C. Auxiliary Feedwater Header connects with the Main Feedwater line downstream of the Main Feedwater Isolation Valves.
1-18
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC HPSI-FLOW1 F5940A HHSI TO HOT LEG HDR FLOW HIGH PRESS SAFETY INJECTION FLOW A
GPM N/A 0
1000 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This value is the flow from the High Head Safety Injection Pumps into the Hot and Cold Reactor Coolant Loops A, B and C. CH-P-1A, B and C provide a HHSI flow rate of 150 GPM at 2500 PSIG. FT-1SI-940 senses flow at the discharge of CH-P-1A, B and C prior to the header connection to the Hot and Cold Legs of Reactor Coolant Loops A, B and C. Ref: Op Manual Chapter 11; RM-411-1; RM-407-1 1-19
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1
[PC HPSI-FLOW2 F5943A HHSI TO BIT FLOW HIGH PRESS SAFETY INJECTION FLOW A
GPM N/A 0
1000 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This value is the flow from the High Head Safety Injection Pumps into the Boron Injection Tank Header. CH-P-1A, B and C provide a HHSI flow rate of 150 GPM at 2500 PSIG. FT-1SI-943 senses flow from the discharge of CH-P-1A, B and C to the High Head Safety Injection Header connection to the Boron Injection Tank. Ref: Op Manual Chapter 11; RM-411-1; RM-407-1 1-20
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC LPSI-FLOW1 F5945A SI-P-1A DISCHARGE FLOW LOW PRESS SAFETY INJECTION FLOW A
GPM N/A 0
4000 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A Low Head Safety Injection Pump SI-P-1A takes a suction on the BWST and provides rated flow of 3000 GPM at 111 PSIG to the reactor coolant loops.
FT-1SI-945 senses flow at the discharge of the Low Head Safety Injection Pump SI-P-1A. Ref: Op Manual Chapter 11; RM-407-1; RM-411-1 1-21
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC LPSI-FLOW2 F5946A SI-P-1B DISCHARGE FLOW LOW PRESS SAFETY INJECTION FLOW A
GPM N/A 0
4000 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A Low Head Safety Injection Pump SI-P-1B takes a suction on the BWST and provides rated flow of 3000 GPM at 111 PSIG to the reactor coolant loops.
FT-1SI-946 senses flow at the discharge of the Low Head Safety Injection Pump SI-P-1B. Ref: Op Manual Chapter 11; RM-407-1; RM-411-1 1-22
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC
,SG-LEVEL-1A L0403A SGA WIDE RANGE LEVEL STEAM GENERATOR A WATER LEVEL A
N/A 0
100 UTUBES SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A LT-1FW-477 senses wide range SG A level and transmits a signal to the Main Control Board, the Emergency Shutdown Panel and the Auxiliary Feed Pump Room. (see attached % level vs. Gallons curve) LT-1FW-477 senses wide range level between the upper tap at 789' 11" and the lower tap at 752' on SG A. Zero reference top of U Tubes elevation 775' 9". Normal water level is at elevation 783' 2". Ref: Op Manual Chapter 24; ISO 6.24-2743.
LOW ALARM 43% (Modes 1 thru 6)
HIGH ALARM = 60% (Modes 1 thru 4); 85% (Modes 5 and 6) 1-23
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
,Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
7/22/1996 BV1 IPC SG-LEVEL-2B L0423A SG B WIDE RANGE LEVEL STEAM GENERATOR B WATER LEVEL A
N/A Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
0 100 UTUBES SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A LT-1FW-487 senses wide range SG B level and transmits a signal to the Main Control Board, the Emergency Shutdown Panel andthe Auxiliary Feed Pump Room. (see attached % level vs. Gallons curve) LT-1FW-487 senses wide range level between the upper tap at 789"11" and the lower tap at 742' on SG B. Zero reference top of U Tubes elevation 775' 9". Normal water level is at elevation 783' 2". Ref: Op Manual Chapter 24; ISO 6.24-2744.
LOW ALARM = 43% (Modes 1 thru 6)
HIGH ALARM = 70% (Modes 1 thru 4); 85% (Modes 5 and 6) 1-24
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC SG-LEVEL-3C L0443A SG C WIDE RANGE LEVEL STEAM GENERATOR C WATER LEVEL A
N/A 0
100 UTUBES SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A
- LT-1FW-497 senses wide range SG C level and transmits a signal to the Main Control Board, the Emergency Shutdown Panel and the Auxiliary Feed Pump Room. (see attached % level vs. Gallons curve) LT-1FW-497 senses wide range level between the upper tap at 789' 11" and the lower tap at 742' on SG C. Zero reference top of U Tubes elevation 775' 9". Normal water level is at elevation 783' 2". Ref: Op Manual Chapter 24; ISO 6.24-2745.
LOW ALARM = 43% (Modes 1 thru 6)
HIGH ALARM = 60% (Modes 1 thru 4); 85% (Modes 5 and 6) 1-25
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
7/22/1996 Reactor Unit:
BV1 Data Feeder:
CTMNT-SP-WR1 Point ID:
L0750A Plant Spec Point Desc.:
RECIRC SUMP WTR LVL 1 Generic/Cond Desc.:
CTMNT SUMP WIDE RANGE LEVEL Analog/Digital:
A Engr Units/Dig States:
IN Engr Units Conversion:
N/A Minimum Instr Range:
0 Maximum Instr Range:
90 Zero Point
Reference:
COMPLX Reference Point Notes:
SEE UNIQUE SYSTEM DESCRIPTION FIELD PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
SEE UNIQUE SYSTEM DESCRIPTION FIELD NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
LT-1RS-151A provides wide range Containment Sump indication at the Main Control Board. LT-1RS-151A senses North side Containment Sump level (Inside Recirculating Spray Pump 1A Sump). Zero Reference 6" above sump bottom. Ref:: Op Manual Chapter 13 LOW ALARM = None (Modes 1 thru 6)
HIGH ALARM = 2.5 IN (Modes 1 thru 5); None (Mode 6).
1-26
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CTMNT-SP-WR2 L0751A RECIRC SUMP WTR LVL 2 CTMNT SUMP WIDE RANGE LEVEL A
IN N/A 0
90 COMPLX SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A LT-1RS-151B provides wide range Containment Sump indication at the Main Control Board. LT-1RS-151B senses North side Containment Sump level (Inside Recirculating Spray Pump 1 B Sump). Zero Reference 6" above sump bottom. Ref: Op Manual Chapter 13 LOW ALARM = None (Modes 1 thru 6)
HIGH ALARM = 2.5 IN (Modes 1 thru 5); None (Mode 6).
1-27
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CNMNT-SP-NR1 L0752A CNMT SUMP WTR LEVEL I
CNMNT SUMP NARROW RANGE LEVEL A
IN N/A 3
15 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 10.0; LO ALM @ 3.5 IN ALL MODES N/A N/A LOW N
N/A LT-1DA-100 provides narrow range Containment Sump indication at the Main Control Board and provides start/stop signals to the Containment Sump Pumps. LT-1DA-100 senses water level in the South side of the Containment Sump (720 Gal). Ref: Op Manual Chapter 9 1-28
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC REAC-VES-LV1 L3204A RX VESSEL FULL. RANGE LEVEL - A REACTOR VESSEL WATER LEVEL A
N/A 0
120 TAF TAF=728'8"(274" FROM BOT RX VESS)=62.5%
S 1
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW Y
WET Connections to the Reactor Vessel Head and Incore Instrument Tube #8 at the Seal Table are the sensing points. Reference line tubing runs from these points to high volume sensors that isolate the RCS from remainder of the RVLIS tubing. Capillary tubing runs from high volume sensors thru the containment wall to hydraulic isolators. RTDs are installed on capillary lines for containment temperature compensation. ICCM receives transmitter output, invalid if RCPs are running. LT-1 RC-1 311 senses reactor vessel level between top of Reactor Vessel Head (Elev. 745' 10") to Thimble Guide Tube
- 8 (Elev. 705' 10").
LOW ALARM = 39% (Mode 3); 95% (Modes 4 and 5)
HIGH ALARM = 120% (Modes 3 thru 5)
No alarnms in Modes 1, 2 and 6 1-29
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/20/2007 BV1 IPC REAC-VES-LV3 L3206A RX VESSEL DYNAMIC LEVEL
- A REACTOR VESSEL WATER LEVEL A
N/A 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW Y
WET Connections to the Reactor Vessel at the Incore Instrument Tubes sense Reactor Vessel core and internal DP. Reference line tubing runs from the instrument tubes to high volume sensors that isolate the RCS from the remainder of the RVLIS tubing. Capillary tubing runs from the high volume sensors thru the containment wall to hydraulic isolators. RTDs are installed on capillary lines for containment temperature compensation. ICCM receives transmitter output; this reading is invalid unless RCPs are running. LT-1 RC-1312 senses DP across Reactor Vessel and internals when any RCPs are running.
LOW ALARM = 95% (Modes 1 thru 5)
HIGH ALARM =119.5% (Modes 1 thru 5)
No alarms in Mode 6 1-30
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC REAC-VES-LV2 L3210A RX VESSEL FULL RANGE LEVEL - B REACTOR VESSEL WATER LEVEL A
N/A 0
120 TAF TAF=728'8"(274" FROM BOT RX VESS)=62.5%
S 1
- N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW Y
WET Connections to the Reactor Vessel Head and Incore Instrument Tube #8 at the Seal Table are the sensing points. Reference line tubing runs from these points to high volume sensors that isolate the RCS from the remainder of the RVLIS tubing. Capillary tubing runs from high volume sensors through the containment wall to hydraulic isolators. RTDs are installed on capillary lines for containment temperature compensation. ICCM receives transmitter output, invalid if RCPs are running. LT-1 RC-1 321 senses Reactor Vessel level between top of Reactor Vessel Head (Elev. 745' 10") to Thimble Guide Tube #8 (Elev. 705' 10").
LOW ALARM = 39% (Mode 3); 95% (Modes 4 and 5)
HIGH ALARM = 120% (Modes 3 thru 5)
No alarms in Modes 1, 2 and 6 1-31
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/20/2007 BV1 IPC REAC-VES-LV4 L3212A RX VESSEL DYNAMIC LEVEL
- B REACTOR VESSEL WATER LEVEL A
ICCM RVLIS ALGORITHM 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW Y
WET Connections to the Reactor Vessel at the Incore Instrument Tubes sense Reactor Vessel core and internal DP. Reference line tubing runs from the instrument tubes to high volume sensors that isolate the RCS from the remainder of the RVLIS tubing. Capillary tubing runs from the high volume sensors thru the containment wall to hydraulic isolators. RTDs are installed on capillary lines for containment temperature compensation. ICCM receives transmitter output; this reading is invalid unless RCPs are running. LT-1RC-1322 senses DP across Reactor Vessel and internals when any RCPs are running.
LOW ALARM =95% (Mode 1 thru 5)
HIGH ALARM =119.5% (Mode 1 thru 5)
No alarms in Mode 6 1-32
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power. Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC NI-SOURC-RNG N0031A SOURCE RANGE DET 1 LOG FLUX NUCLEAR INSTRUMENTS SOURCE RANGE A
CPS LOG Y = 6/5
- VOLTS 1
1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD i/21NTRNG>IE-10 2/21NTRNG<1E-10 LOW N
N/A Source Range provides power level indication from about 10E-10 % to 1OE-4
%. Source Range power level is calibrated from 1 to 1.0E6 counts per second. N-31 (see attached NIS detector location dwg.) Ref: Op Manual Chapter 2 LOW ALARM = No low alarm in any mode HIGH ALARM 9.0E4 CPS (Modes 1 thru 4); 500 CPS (Modes 5 and 6) 1-33
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Nurmber of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC EXTRA5 N0032A SOURCE RANGE DET 2 LOG FLUX NUCLEAR INSTRUMENTS SOURCE RANGE A
CPS LOG Y = 6/5
- VOLTS 1
1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD 1/21NTRNG>IE-10 2/21NTRNG<IE-10 LOW N
N/A Source Range provides power level indication from about 10E-10 % to 1OE-4
%. Source Range power level is calibrated from 1 to 1.0E6 counts per second. N-32 (see attached NIS detector location dwg.) Ref: Op Manual Chapter 2 LOW ALARM = No low alarm in any mode HIGH ALARM = 9.0E4 CPS (Modes 1 thru 4); 500 CPS (Modes 5 and 6) 1-34
BEAVER VALLEY POWER STATION ERDS DATA POINT.LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed; Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
12/18/2002 BV1 IPC NI-INTER-RNG N0035A INTERMEDIATE RANGE DET 1 LOG FLUX NUC INSTRUMENTS, INT RANGE A
AMP LOG Y = 8/5
- VOLTS - 11 1.OE-1 1 1.OE-3 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD 2/4 PWR RNG>10%
3/4 PWR RNG<10%
LOW N
N/A Intermediate Range level indication from 1.OE-1 1 to 1.OE-3 AMPS corresponds to about 10E-6 % to 10E2 % full rated power. Power Range level indication will not come on scale until the reactor power level rises to about 10E-5 AMPS Intermediate Range level. (-1% Full Power). N-35 (see attached NIS detector location dwg.) Ref: Op Manual Chapter 2.
LOW ALARM = 1.OE-1 1 AMP HIGH ALARM = 1.OE-03 AMP (Mode 1): 1.3E-04 AMP (Mode 2 thru 6) 1-35
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:.
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
12/18/2002 BV1
[PC EXTRA4 N0036A INTERMEDIATE RANGE DET 2 LOG FLUX NUC INSTRUMENTS, INT RANGE A
AMP LOG Y = 8/5
- V - 11 1.0E-11 1.OE-3 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD 2/4 PWR RNG>10%
3/4 PWR RNG<10%
LOW N
N/A Intermediate Range level indication from 1.OE-11 to 1.OE-3 AMPS corresponds to about 1OE-6 % to 10E2 % full rated power. Power Range level indication will not come on scale until the reactor power level rises to about 10E-5 AMPS Intermediate Range level. (-1% Full Power). N-36 (see attached NIS detector location dwg.) Ref: Op Manual Chapter 2..
LOW ALARM = 1.OE-1 1 AMP HIGH ALARM = 1.OE-03 AMP (Mode 1); 1.3E-04 AMP (Mode 2 thru 6) 1-36
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant.Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC NI-POWER-RNG N0049A PWR RNG CHANNEL 1 FLUX (QUAD 4)
NUCLEAR INSTRUMENTS, POWER RANGE A
LINEAR 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Power Range level is calibrated from a secondary plant calorimetric calculation to provide full rated power level. Power Range level is an average of the upper and lower detector flux levels. N-41A and N-41 B (see attached NIS detector location dwg.) Ref: Op Manual Chapter 2 LOW ALARM = 0% (Modes 1 and 2); None (Modes 3 thru 6)
HIGH ALARM 102% (Mode 1); 20% (Mode 2); 109% (Modes 3 thru 6)
Also alarms on redundant tolerance.
1-37
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
7/22/1996 BV1 IPC EXTRAI1 N0050A PWR RNG CHANNEL 2 FLUX (QUAD 2)
NUCLEAR INSTRUMENTS, POWER RANGE A
LINEAR Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
0 120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Power Range level is calibrated from a secondary plant calorimetric calculation to provide full rated power level. Power Range level is an average of the upper and lower detector flux levels. N-42A and N-42B (see attached NIS detector location dwg.) Ref: Op Manual Chapter 2 LOW ALARM = 0% (Modes 1 and 2); None (Modes 3 thru 6)
HIGH ALARM = 102% (Mode 1); 20% (Mode 2); 109% (Modes 3 thru 6)
Also alarms on redundant tolerance.
1-38
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC EXTRA2 N0051A PWR RNG CHANNEL 3 FLUX (QUAD 1)
NUCLEAR INSTRUMENTS, POWER RANGE A
LINEAR 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Power Range level is calibrated from a secondary plant calorimetric calculation to provide full rated power level. Power Range level is an average of the upper and lower detector flux levels. N-43A and N-43B (see attached NIS detector location dwg.) Ref: Op Manual Chapter 2 LOW ALARM = 0% (Modes 1 and 2); None (Modes 3 thru 6)
HIGH ALARM = 102% (Mode 1); 20% (Mode 2); 109% (Modes 3 thru 6)
Also alarms on redundant tolerance.
1-39
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC EXTRA3 N0052A PWR RNG CHANNEL 4 FLUX (QUAD 3)
NUCLEAR INSTRUMENTS, POWER RANGE A
LINEAR 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Power Range level is calibrated from a secondary plarnt calorimetric calculation to provide full rated power level. Power Range level is an average of the upper and lower detector flux levels. N-44A and N-44B (see attached NIS detector location dwg.) Ref: Op Manual Chapter 2 LOW ALARM = 0% (Modes 1 and 2); None (Modes 3 thru 6)
HIGH ALARM,= 102% (Mode 1); 20% (Mode 2); 109% (Modes 3 thru 6)
Also alarms on redundant tolerance.
1-40
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
VNRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC RCS-PRESSURE P0498A RCS LOOP 2 WIDE RANGE PRESS REACTOR COOLANT SYSTEM PRESSURE A
PSIG N/A 0
3000 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A PT-1RC-403 is RCS wide range pressure indication at the Main Control Board, and the Back-Up Indicating Panel. PT-1RC-403 also provides an open and close signal to PORV (PVC-! RC-455C). PT-1 RC-403 is located in Containment. PT-1RC-403 senses pressure between the Reactor Vessel and Loop B Hot Leg Isolation Valve MOV-1RC-592. Ref: Op Manual Chapter 6; RM-406-1 HIGH ALARM = 2300 PSIG (Modes 1 thru 3); 375 PSIG (Modes 4 and 5);
300 PSIG (Mode 6)
LOW ALARM = 2150 PSIG (Modes 1 and 2); 300 PSIG (Mode 3); 0 PSIG (Modes 4 thru 6) 1-41
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BVI IPC EXTRA9 P0499A RCS WR PRESSURE REACTOR COOLANT SYSTEM PRESSURE A
PSIG N/A 0
3000 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A PT-1 RC-402 is RCS wide range pressure indication at the Main Control Board, and the Back-Up Indicating Panel. PT-1 RC-402 also provides an open and close signal to PORV (PVC-1 RC-455D). PT-1 RC-402 is located in Containment. PT-iRC-402 senses pressure between the Reactor Vessel and Loop C Hot Leg Isolation Valve MOV-1RC-594. Ref: Op Manual Chapter 6; RM-406-1 HIGH ALARM = 2300 PSIG (Modes 1 thru 3); 375 PSIG (Modes 4 and 5);
300 PSIG (Mode 6)
LOW ALARM = 2150 PSIG (Modes 1 and 2); 300 PSIG (Mode 3); 0 PSIG (Modes 4 thru 6) 1-42
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:.
Level Reference Leg:
Unique System Desc.:
3/2/2007 BV1 IPC CTMNT-PRESS P1008A WIDE RANGE CNMT PRESS CH 1 CONTAINMENT PRESSURE A
PSIA N/A 0
200 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A PT-1LM-101A provides wide range containment pressure indication at the main control board. PT-1LM-101A senses containment pressure at a pressure tap located between TV-1LM-100A1 and TV-1LM100A2 (containment isolation valves) and containment. Ref: Op Manual Chapter 12.
LOW ALARM = 12.8 PSIA in Modes 1 thru 4 HIGH ALARM = 14.2 PSIA in Modes 1 thru 4 No alarms in Modes 5 and 6 1-43
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum. Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/2/2007 BV1 IPC EXTRA21 P1009A WIDE RANGE CNMT PRESS CH 2 CONTAINMENT PRESSURE A
PSIA N/A 0
200 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A PT*1LM-101B provides wide range containment pressure indication at the main control board. PT-1LM-101B senses containment pressure at a pressure tap located between TV-1 LM-1 00A1 and TV-1 LM100A2 (containment isolation valves) and containment. Ref: Op Manual Chapter 12.
LOW ALARM = 12.8 PSIA in Modes 1 thru 4 HIGH ALARM = 14.2 PSIA in Modes 1 thru 4 No alarms in Modes 5 and 6.
1-44
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC PRZR-LEVEL U0483 PRESSURIZER LEVEL 1/2/3 AVG PRIMARY SYSTEM PRESSURIZER LEVEL A
N/A 0
100 TOPHTR SEE UNIQUE SYSTEM DESCRIPTION FIELD P
3 SAVG ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD NO ALARMS IN ANY MODE N/A N/A LOW N
N/A U0483 can be the average of three, two or one level transmitter signal depending on the deviation between values. See attached curve of % level vs Pressurizer volume in Gallons. LT-1 RC-459, 460 and 461 sense Pressurizer level from 748' 1/4" (lower transmitter tap) to 781' 2 5/8" (upper transmitter tap). Zero reference minimum water level is at 752' 1 1/4" or approximately 12%. Ref: Op Manual Chapter 6; 8700-415.6A; 8700-6.24-C12821 1-45
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC EXTRA10 U0472 PRESSURIZER PRESS 1/2/3 AVG REACTOR COOLANT SYSTEM PRESSURE A
PSIG N/A 1700 2500 N/A N/A P
3 SAVG ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A U0472 is composed of three Pressurizer pressures, the point can be the average of three, average of two or a single value depending on the deviation of values.
1-46
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC COND-AE-RAD1 R0029A CONDENSER AIR EJECTOR COND AIR EJECTOR RADIOACTIVITY A
CPM N/A 10 1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1SV-100 continuously monitors the effluent for gaseous activity (1-131, Xe-133, Kr-85) from the condenser air ejector vent. An alarm indicates a primary to secondary leak. A High-High radioactivity alarm diverts the gaseous discharge to the Containment Building for subsequent discharge through the Elevated Release Point. A beta scintillation detector continuously monitors the condenser air ejector vent. Ref: Op Manual Chapter 43, RM-422-1 1-47
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC EFF-LIQ-RAD1 R0030A LIQUID WASTE EFFLUENT RADIOACTIVITY OF RELEASED LIQUID A
CPM N/A 10 1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-11LW-104 monitors the activity (Co-60 and Cs-137) of any radioactive liquid waste discharged from the station. A High-High activity automatically terminates flow by closing the discharge line isolation valves. A gamma scintillation detector monitors the activity of radioactive liquid waste discharged down stream of the last point of radioactive effluent addition to the discharge header. Ref. Op Manual Chapter 43, RM-417-1 1-48
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC SG-BD-RAD-1A R0034A STEAM GENERATOR BLOWDOWN STM GEN A/B/C BLOWDOWN RAD LEVEL A
CPM N/A 10 1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1BD-100 monitors the blowdown discharged from the Blowdown Heat Exchanger discharge line for Co-60 and Cs-137. A High-High alarm may indicate a primary to secondary leak. A gamma scintillation detector monitors activity from samples taken at the discharge of the Blowdown Drain Heat Exchanger. Ref: Op Manual Chapter 43.
1-49
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC RCS-LTD-RAD 1 R0036A RX COOLANT LETDOWN HI RANGE RAD LEVEL OF RCS LETDOWN LINE A
CPM N/A 10 1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1CH-101A monitors the gross activity of the reactor coolant (Co-60 and Cs-137) by drawing samples from the reactor coolant letdown line and delaying them to permit sufficient decay of the N-16 isotope before they pass by the detectors. This is an indication of fission products present in the reactor coolant. This radiation monitor provides the Low and High range indication. A gamma scintillation detector monitors the gross activity of the reactor coolant by drawing samples from the Reactor Coolant Letdown line downstream of the non-regenerative heat exchanger. Ref: Op Manual Chapter 43 1-50
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC RCS-LTD-RAD2 R0037A RX COOLANT LETDOWN LO RANGE RAD LEVEL OF RCS LETDOWN LINE A
CPM N/A 10 1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1CH-101B monitors the gross activity of the reactor coolant (Co-60 and Cs-137) by drawing samples from the reactor coolant letdown line and delaying them to permit sufficient decay of the N-16 isotope before they pass by the detectors. This is an indication of fission products present in the reactor coolant. This radiation monitor provides the low and high range indication. A gamma scintillation detector monitors the gross activity of the reactor coolant by drawing samples from the Reactor Coolant Letdown line down stream of the Non-Regenerative Heat Exchanger. Ref: Op Manual Chapter 43 1-51
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC
.CTMNT-RAD1 R0070A CNMT HIGH RANGE RAD MONITOR CH 1 RADIATION LEVEL IN CONTAINMENT R/HR N/A 1
1 E7 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1RM-219A functions as an accident detector measuring radiation levels inside Containment. An ion chamber detector monitors accident radiation levels inside Containment on the Crane Wall above the operating floor. Ref:
Op Manual Chapter 43 1-52
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
8/16/1999 BV1 IPC CTMNT-RAD2 R0071A CNMT HIGH RANGE RAD MONITOR CH 2 RADIATION LEVEL IN CONTAINMENT A
R/HR N/A Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
1E7 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1RM-219B functions as an accident detector measuring radiation levels inside Containment. An ion chamber detector monitors accident radiation levels inside Containment on the Crane Wall above the operating floor. Ref:
Op Manual Chapter 43 1-53
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum lnstr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC BWST-LEVEL1 RWSTLEV RWST AVERAGE LEVEL 1/2/3 BORATED WATER STORAGE TANK LEVEL A
FEET N/A 0
55 COMPLX SEE UNIQUE SYSTEM DESCRIPTION FIELD P
3 SAVG SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A The BWST at BV1 is referred to as "Refueling Water Storage Tank" (RWST).
There is one RWST at BV1 with a capacity of 446,035 Gallons. There is about 6,000 unusable gallons below the Quench Spray pump suction. There are approximately 8483 gallons/ft. in the RWST. (see attached tank curve).
RWST level signal is the average of 3, 2 or a single value depending on the deviation between values. LT-1QS-100A, B and C sense level in the BWST at the 736' 6" elevation. Zero point reference: the bottom of BWST is at 735' 6" elevation and the suction line for Quench Spray pumps is at 736' 3" elevation.
1-54
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CL-TEMP-1A T0406A RCLA WR TCOLD STM GEN A OUTLET TEMPERATURE A
DEGF N/A 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Reactor Coolant Loop A Cold Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant computer. TRB-RC-410 is located between RC-P-1A discharge and the A Loop Stop Valve. Ref:
Op Manual Chapter 6; RM-406-1 LOW ALARM = 541 DEGF (Modes 1 and 2); 350 DEGF (Mode 3); 190 DEGF (Mode 4); 0 DEGF (Modes 5 and 6)
HIGH ALARM = 560 DEGF (Modes 1 and 2); 550 DEGF (Mode 3); 350 DEGF (Mode 4); 200 DEGF (Mode 5); 140 DEGF (Mode 6)
Also alarms on redundant tolerance 1-55
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC HL-TEMP-1A T0419A RCLA WR THOT STM GEN A INLET TEMPERATURE A
DEGF N/A 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Reactor Coolant Loop A Hot Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant computer. TRB-RC-413 is located between A Loop Stop Valve and Coolant Inlet to SG A. Ref:
Op Manual Chapter 6; RM-406-1 LOW ALARM = 541 DEGF (Modes 1 and 2); 350 DEGF (Mode 3); 200 DEGF (Mode 4); None (Modes 5 and 6)
HIGH ALARM = 650 DEGF (Modes 1 and 2); 550 DEGF (Mode 3); 350 DEGF (Mode 4); 200 DEGF (Mode 5); 140 DEGF (Mode 6)
Also alarms on redundant tolerance 1-56
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CL-TEMP-2B T0426A RCLB WR TCOLD STM GEN B OUTLET TEMPERATURE A
DEGF N/A 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Reactor Coolant Loop.B Cold Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant computer. TRB-RC-420 is located between RC-P-1B discharge and the B Loop Stop Valve. Ref:
Op Manual Chapter 6; RM-406-1 LOW ALARM = 541 DEGF (Modes 1 and 2); 350 DEGF (Mode 3); 190 DEGF (Mode 4); none (Modes 5 and 6)
HIGH ALARM = 560 DEGF (Modes 1 and 2); 550 DEGF (Mode 3); 350 DEGF (Mode 4); 200 DEGF (Mode 5); 140 DEGF (Mode 6)
Also alarms on redundant tolerance 1-57
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC HL-TEMP-2B T0439A RCLB WR THOT STM GEN B INLET TEMPERATURE A
DEGF N/A 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Reactor Coolant Loop B Hot Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant computer. TRB-RC-423 is located between B Loop Stop Valve and Coolant Inlet to SG B. Ref:
Op Manual Chapter 6; RM-406-1 LOW ALARM = 541 DEGF (Modes 1 and 2); 350 DEGF (Mode 3); 200 DEGF (Mode 4); None (Modes 5 and 6)
HIGH ALARM = 650 DEGF (Modes 1 and 2); 550 DEGF (Mode 3); 350 DEGF (Mode 4); 200 DEGF (Mode 5); 140 DEGF (Mode 6)
Also alarms on redundant tolerance 1-58
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CL-TEMP-3C T0446A RCLC WR TCOLD STM GEN C OUTLET TEMPERATURE A
DEGF N/A 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Reactor Coolant Loop C Cold Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant computer. TRB-RC-430 is located between RC-P-1C discharge and the C Loop Stop Valve. Ref:
Op Manual Chapter 6; RM-406-1,
LOW ALARM = 541 DEGF (Modes 1 and 2); 350 DEGF (Mode 3); 190 DEGF (Mode 4); none (Modes 5 and 6)
HIGH ALARM = 560 DEGF (Modes 1 and 2); 550 DEGF (Mode 3); 350 DEGF (Mode 4); 200 DEGF (Mode 5); 140 DEGF (Mode 6)
Also alarms on redundant tolerance 1-59
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC HL-TEMP-3C T0459A RCLC WR THOT STM GEN C INLET TEMPERATURE A
DEGF N/A 0
700 N/A N/A.
S 1
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A Reactor Coolant Loop C Hot Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant computer. TRB-RC-433 is located between C Loop Stop Valve and Coolant Inlet to SG C. Ref:
Op Manual Chapter 6; RM-406-1 LOW ALARM = 541 DEGF (Modes 1 and 2); 350 DEGF (Mode 3); 200 DEGF (Mode 4); None (Modes 5 and 6)
HIGH ALARM = 650 DEGF (Modes 1 and 2); 550 DEGF (Mode 3); 350 DEGF (Mode 4); 200 DEGF (Mode 5); 140 DEGF (Mode 6)
Also alarms on redundant tolerance 1-60
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
6/2/2009 BV1 IPC EXTRA20 U1000 CONTAINMENT PRESS 1/2/3 AVG CONTAINMENT PRESSURE A
PSIG N/A
-10 55 N/A N/A P
3 SAVG ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD NO ALARMS IN ANY MODE N/A N/A LOW N
N/A U1000 receives inputs from all three pressure transmitters and can be the average of three, two, or a single value depending on the deviation of values.
PT-1 LM-1 OOA, B, & C sense containment pressure at a pressure tap located between TV-LM-100A1 and A2 (containment isolation valves) and containment. Ref: Op Manual Chapter 12 1-61
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
6/13/2007 BV1 iPC SUB-MARGIN1 U0094 SUBCOOL (AVG 5 HI T/C) ICCM AVG SATURATION TEMP - HIGHEST CET A
DEGF N/A
-35 200 N/A N/A P
53.
FROM TRAIN A & TRAIN B ICCM SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A LOW N
N/A The average of Train A and Train B ICCM subcooling (AVG 5 HI T/C) points.
The ICCM computes subcooling based on the average of the 5 hottest Incore T/Cs and sends these calculated values to the "IPC" as 1 to 5 volt outputs from the ICCM Demultiplexer. The two "IPC" points are then averaged together to produce U0094.
LOW ALARM = 15 DEGF (Mode 1)
LO-LO ALARM = 10 DEGF (Mode 1)
LOW ALARM = -35 DEGF (Modes 2 thru 4)
HIGH ALARM = 200 DEGF (Modes 1 thru 4)
No alarms in Modes 5 and 6 1-62
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC TMP-CORE-EX1 U0093 IN CORE T/C 5 HOTTEST AVG HIGHEST TEMPERATURE AT CORE EXIT A
DEGF N/A 32 2300 N/A N/A P
51 U0091 PA09 OUTPUT SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 2300; LO ALM @ 32 [ALL MODES]
N/A N/A LOW N
N/A The "IPC" computer produces U0093 as part of its PA09 calculation of U0091. The PA09 calculation computes the average temperature, maximum temperature, the relative index of the highest temperature thermocouple and the average of the 5 highest Incore Thermocouples.
1-63
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
7/22/1996 BV1 IPC CTMNT-TEMP U1008 AVG OF 5 TS CNMT AIR TEMPS CONTAINMENT TEMPERATURE A
DEGF N/A 0
300 N/A N/A P
5 AVERAGE SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A HIGH N
N/A U1008 is the average of all five temperature inputs. T-LM100-4 senses temperature at 744' in the Pressurizer Cubicle; T-LM100-7 senses temperature at 799' on the Operating Floor NE of the Crane Wall; T-LM100-10 senses temperature at 850' in the NNE Containment Dome; T-LM100-15 senses temperature at 730' in the SSE Annulus; T-LM-100-16 senses temperature at 701' 6" in the ENE Annulus (see attached dwg.)
LOW ALARM = 77 DEGF (Modes 1 thru 4); 32 DEGF (Modes 5 and 6)
HIGH ALARM = 111 DEGF (Modes 1 thru 6) 1-64
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC EXTRA 18 Y0705A COMP COOLING/RECIRC SPRAY HX RW RADIOACTIVITY OF RELEASED LIQUID A
CPM N/A 10 1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1RW-100 samples for activity (Co-60 and Cs-137) at the discharge of the Reactor Plant Component Cooling Water Heat Exchangers. Following a CIB signal the HHSI Pump Oil Cooler and the Recirculation Spray Heat Exchanger discharge is also monitored. High activity is indicative of a heat exchanger leak. A gamma scintillation detector monitors the combined river water discharge manifold downstream of the Reactor Plant Component Cooling Water / Recirculation Spray Heat Exchangers. Ref: Op Manual Chapter 43; RM-430-3 1-65
BEAVER VALLEY POWER STATION
.ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec.Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC EFF-LIQ-RAD2 Y0717A LIQUID WASTE CONTAINMENT DN EFF RADIOACTIVITY OF RELEASED LIQUID A
CPM N/A 10 1E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1LW-116 continuously monitors the activity (Co-60 and Cs-137) of the effluent down stream of the Liquid Waste Contaminated Drains Filter. A High-High activity will automatically close the isolation valves to terminate flow. A gamma scintillation detector monitors the activity of liquid waste contaminated drains effluent down stream of the Contaminated Drains Filter.
Ref: Op Manual Chapter 43; RM-417-1 1-66
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply"Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/16/1999 BV1 IPC EXTRA19 Y0735A REACTOR CONTAINMENT L/R RADIATION LEVEL IN CONTAINMENT A
MR/HR N/A 0.1 10000 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD SEE UNIT 1 RMS SETPOINT LOG N/A N/A LOW N
N/A RM-1RM-202 monitors the radiation level inside Containment and warns personnel of an increase in the radiation level. A geiger-mueller detector monitors radiation level inside the Containment Crane Wall opposite the personnel access. Ref: Op Manual Chapter 43 1-67
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS WIND-SPEED1 XM006 WIND SPEED 35' ELEVATION WIND SPEED AT THE REACTOR SITE A
MPH N/A 50 50 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments, as ground level speed.
Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-68
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
- PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1
.ARERAS WIND-SPEED2 XM026 WIND SPEED 500' ELEVATION WIND SPEED AT THE REACTOR SITE A
MPH N/A 0
50 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is the 15 minute average value for primary sensor. Redundant sensor substituted if primary bad or missing. Sensors are same quality/calibration.
Value is dose assessments as elevated wind speed. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-69
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS WIND-DIR1 XM051 WIND DIRECTION 150' ELEVATION WIND DIRECTION AT REACTOR SITE A
DEGFR N/A 0
360 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments as ground level direction. Wind direction 0 is North., Wind direction is direction from which wind is coming. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-70
BEAVER VALLEY POWER STATION ERDS'DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS WIND-DIR2 XM061 WIND DIRECTION 500' ELEVATION WIND DIRECTION AT REACTOR SITE A
DEGFR N/A 0
360 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments as ground level direction. Wind direction 0 is North. Wind direction is direction from~which wind is coming. Ref: Calculation Package ERS-SFL-92-024; CR 04/05484 1-71
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig S tates:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:.
Unique System Desc.:
11/14/1992 BV1 ARERAS STAB-CLASS1 XM083 STABILITY-GROUND LEVEL A*IR STABILITY AT REACTOR SITE A
STABI N/A 1
7 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N.
N/A Point is based on 15 minute average Delta-T for 35' and 150' temperature sensors. Based on redundant sensorif primary bad or missing. Sensors are same quality/calibration. Stability classes 1 thru 7 correspond to stability classes A to G. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-72
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS STAB-CLASS2 XM087 STABILITY-ELEVATED AIR STABILITY AT REACTOR SITE A
STABI N/A 1
7 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is based on 15 minute average Delta-T for 35' and 500' temperature sensors. Based on redundant sensor if primary bad or missing. Sensors are same quality/calibration. Stability classes 1 thru 7 correspond to stability classes A thru G. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-73
BEAVER VALLEY POWER.STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS EXTRA11 XR001 1RM-MS-101 RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 0.01 4E4 N/A N/A P
2 CALCULATED SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A RM-1MS-101 monitors the activity in one of the two exhaust lines of the turbine driven auxiliary feed pump. High activity alarms alert the operator to abnormal conditions. Monitor is a gamma scintillation detector. Ref: Op Manual Chapter 43; RM-421-1; Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-74
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
EngrUnits/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS EXTRA12 XR002 1RM-MS-100A RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 0.01 4E4 N/A N/A P
2 CALCULATED
.SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A RM-1MS-100A monitors the activity in the discharge path of Main Steam Relief Loop A when the Atmospheric Dump Valve or Main Steam Safety Valves discharge to the environment. Detector located in discharge piping downstream of the lowest lift setpoint Main Steam Safety Valve and the Atmospheric Dump Valve on Main Steam Relief Loop A. Ref: Op Manual Chapter 43; RM-421-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-75
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BVl ARERAS EXTRA13 XR003 1RM-MS-100B RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 0.01 4E4 N/A N/A P
2 CALCULATED SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A RM-1MS-100B monitors the activity in the discharge path of Main Steam Relief Loop B when the Atmospheric Dump Valve or Main Steam Safety Valves discharge to the environment. Detector located in discharge piping downstream of the lowest lift setpoint Main Steam Safety Valve and the Atmospheric Dump Valve on Main Steam Relief Loop B. Ref: Op Manual Chapter 43; RM-421-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-76
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS EXTRA14 XR004 1 RM-MS-1 OOC RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 0.01 4E4 N/A N/A P
2 CALCULATED SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A RM-1MS-100C monitors the activity in the discharge path of Main Steam Relief Loop C when the Atmospheric Dump Valve or Main Steam Safety Valves discharge to the environment. Detector located in discharge piping downstream of the lowest lift setpoint Main Steam Safety Valve and the Atmospheric Dump Valve on Main Steam Relief Loop C. Ref: Op Manual Chapter 43; RM-421-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-77
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
12/4/1992 BVl ARERAS EFF-GAS-RAD 1 XR005 1RM-VS-109 CH5 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=1.24E7 CPM/uCl/cc 1.0 1.2E6 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 879 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to 10 CFR 20 Limits at most restrictive receptor per ODCM. RM-1VS-109 monitors for low range noble gases at the discharge of the Auxiliary Building shielded area exhaust fans and at the discharge of the Containment Refueling and Purge Exhaust Fan (during refueling). Provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-78
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
12/4/1992 BV1 ARERAS EFF-GAS-RAD2 XR006 1RM-VS-109 CH7 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=3.54E2 CPM/uCl/cc 1.0 1.2E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH <= 669 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to a General Emergency for eight hours.
RM-1VS-109 Channel 7 monitors for mid range noble gases at the discharge of the Auxiliary Building Shielded Area Exhaust Fans and at the discharge of the Containment Refueling and Purge Exhaust Fan (during refueling). This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-79
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
12/4/1992 BV1 ARERAS EFF-GAS-RAD3 XR007 1RM-VS-109 CH9 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=3.95 CPM/uCl/cc 1.0 1.2E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD 13.2 N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. RM-1VS-109 Channel 9 monitors for high range noble gases at the discharge of the Auxiliary Building Shielded Area Exhaust Fans and at the discharge of the Containment Refueling and Purge Exhaust Fan (during refueling). This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data.
Ref: Op Manual Chapter 43; RM-416-1; Calculation Package ERS-SFL 024; CR 04-05484 1-80
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS EFF-GAS-RAD4 XR009 1RM-VS-110 CH5 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=1.33E7 CPM/uCl/cc 1.0 1.2E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 2030 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to 10 CFR 20 Limits at most restrictive receptor per ODCM. RM-IVS-110 Channel 5 monitors for low range noble gases at the discharge of the Leak Collection Area Exhaust Fans before the Elevated Release Vent. This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-81
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS EFF-GAS-RAD5 XR010 1RM-VS-110 CH7 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=3.01E2 CPM/uCI/cc 1.0 1.2E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH <- 798 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCI/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to a General Emergency if the release continues 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. RM-1VS-110 Channel 7 monitors for mid range noble gases at the discharge of the Leak Collection Area Exhaust Fans before the Elevated Release Vent. This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 1-82
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS EFF-GAS-RAD6 XR01 1 1RM-VS-110 CH9 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=4.87 CPM/uCl/cc 1.0 1.2E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD 22.8 N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. RM-1VS-110 Channel 9 monitors for high range noble gases at the discharge of the Leak Collection Area Exhaust Fans before the Elevated Release Vent. This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data.
Ref: Op Manual Chapter 43; RM-416-1; Calculation Package ERS-SFL 024; CR 04-05484 1-83
-BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:,
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS EXTRA15 XR013 1RM-GW-109 CH5 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=1.26E7 CPM/uCI/cc 1.0 1.2E6 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 3.6E5 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected anddecay period. Alarm setpoint corresponds to 10 CFR 20 Limits at most restrictive receptor per ODCM. RM-1GW-109 Channel 5 monitors for low range noble gases at the discharge of the gaseous waste disposal blowers. This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-419-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-84
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:. 11/14/1992 Reactor Unit:
BV1 Data Feeder:
ARERAS NRC ERDS Parameter:
EXTRAI6 Point ID:
XR014 Plant Spec Point Desc.:
1RM-GW-1 Generic/Cond Desc.:
RADIOACT Analog/Digital:
A Engr Units/Dig States:
CPM Engr Units Conversion:
Xe133=3.0(
Minimum Instr Range:
1.0 Maximum Instr Range:
1.2E6 Zero Point
Reference:
N/A Reference Point Notes:
N/A PROC or SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Location:
SEE UNIQI Alarm/Trip Set Points:
N/A NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
Point is 1 m 09 CH7 IVITY OF RELEASED GASSES
)E2 CPM/uCI/cc UE SYSTEM DESCRIPTION FIELD ON FAILURE MODE minute average. Site dose assessment varies CPM to uCl/cc depending on which default source term was selected and decay
-1GW-109 Channel 7 monitors for mid range noble gases at the f the gaseous waste disposal blowers. This SPING monitor arms to warn the operator of abnormal releases and provides input integrated release data. Ref: Op Manual Chapter 43; RM-419-1; Package ERS-SFL-92-024; CR 04-05484 1-85
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV1 ARERAS EXTRA17 XR015 1RM-GW-109 CH9 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=3.95 CPM/uCI/cc 1.0 1.2E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 1.83E5 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to a General Emergency if the release continues for eight hours. RM-1GW-109 Channel 9 monitors for High Range noble gases at the discharge of the Gaseous Waste Disposal Blowers. The monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-419-1; Calculation Package ERS-SFL-92-024; CR 04-05484 1-86
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/20/2007 BV2 PCS CORE-FLOW1 F0400A RCL A FLW RCS-FT414 REACTOR COOLANT LOOP A FLOW A
FLOW 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 100, LO ALM.@ 95 N/A N/A LOW N
N/A 2RCS-FT414 senses RCS Loop A flow and provides a signal to the computer, SSPS, and the Main Control Board. The Reactor Coolant Pump design flow rate is 95,230 GPM at 542F and 2250 PSIG. 100% flow in Loop A is approximately 3.5E7 LBM/HR. 2RCS-FT414 senses flow at the Reactor Coolant Pipe Elbow at SG A Outlet. Ref: 10080-TLD-006-045; RM-406-1; RM-406-3; 2BVT 1.6.1.
2-01
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
3/20/2007 BV2 PCS CORE-FLOW2 F0421A RCL B FLW RCS-FT425 REACTOR COOLANT LOOP B FLOW A
FLOW 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIALM@100, LOALM@95 N/A N/A LOW N
N/A 2RCS-FT425 senses RCS Loop B flow and provides a signal to the computer, SSPS, and the Main Control Board. The Reactor Coolant Pump design flow rate is 95,230 GPM at 542F and 2250 PSIG. 100% flow in Loop B is approximately 3.5E7 LBM/HR. 2RCS-FT425 senses flow at the Reactor Coolant Pipe Elbow at SG B Outlet. Ref: 10080-TLD-006-062; RM-406-1; RM-406-3; 2BVT 1.6.1.
2-02
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
3/20/2007 Reactor Unit:
BV2 Data Feeder:
CORE-FLOW3 Point ID:
F0442A Plant Spec Point Desc.:
RCL C FLW RCS-FT436 Generic/Cond Desc.:
REACTOR COOLANT LOOP C FLOW Analog/Digital:
A Engr Units/Dig States:
Engr Units Conversion:
FLOW Minimum Instr Range:
0 Maximum Instr Range:
120.
Zero Point
Reference:
N/A Reference Point Notes:
N/A PROCor SENS:
S Number of Sensors:
1 How Processed:
N/A Sensor Location:
SEE UNIQUE SYSTEM DESCRIPTION FIELD Alarm/Trip Set Points:
HI ALM @ 100, LO ALM @ 95 NI Detector Power Supply Cut-Off Power Level:
N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
LOW Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
2RCS-FT436 senses RCS Loop C flow and provides a signal to the computer, SSPS, and the Main Control Board. The Reactor Coolant Pump design flow rate is 95,230 GPM at 542F and 2250 PSIG. 100% flow in Loop C is approximately 3.5E7 LBM/HR. 2RCS-FT436 senses flow at the Reactor Coolant Pipe Elbow at SG C Outlet. Ref: 10080-TLD-006-079; RM-406-1; RM-406-3; 2BVT 1.6.1.
2-03
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Pr6cessed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS REAC-VES-LV3 UPS013 RVLIS FULL RANGE LEVEL TRAIN A REACTOR VESSEL WATER LEVEL A
PSMS RVLIS ALGORITHM 0
120
-TAF TAF=729'3"(276 FROM BOT RX VESS)=62.5%
P 1
PSMS RVLIS ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW Y
WET Connections to the Reactor Vessel Head and Incore InstrumentatiOn Tube
- 20 at the Seal Table are the sensing points. Reference line tubing runs from these points to High'Volume Sensors which isolate the RCS from the remainder of the RVLIS tubing. Capillary tubing runs from the High Volume Sensors through the Containment Wall to hydraulic isolators. RTDs are installed on capillary lines for Containment temperature compensation.
PSMS receives transmitter output. Reading is invalid if RCPs are running.
2RCS-LT1 311 senses Reactor Vessel level between the top of the Reactor Vessel Head elevation 746'6" to Thimble Guide Tube #20 elevation 705' 9".
2-04
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS REAC-VES-LV1 UPS017 RVLIS DYNAMIC RANGE TRAIN A REACTOR VESSEL WATER LEVEL A
N/A 0
120 N/A N/A P
1 PSMS RVLIS ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW Y
WET Connections to the Reactor Vessel Head at the Incore Instrumentation Tubes sense Reactor Vessel core and internal DP. Reference line tubing runs from the instrument tubes to High Volume Sensors which isolate the RCS from the remainder of the RVLIS tubing. Capillary tubing runs from the High Volume Sensors through the Containment Wall to hydraulic isolators. RTDs are installed on capillary lines for containment temperature compensation. PSMS receives transmitter output. Reading is invalid unless RCPs are running.
2RCS-LT1312 senses DP across Reactor Vessel core and internals when any RCPs are running. Normal DP is 110-112%.
2-05
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS REAC-VES-LV4 UPS014 RVLIS FULL RANGE LEVEL TRAIN B REACTOR VESSEL WATER LEVEL A
PSMS RVLIS ALGORITHM 0
120 TAF TAF=729'3"(276" FROM BOT RX VESS)=62.5%
P 1
PSMS RVLIS ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW Y
WET Connections to the Reactor Vessel Head and Incore Instrumentation Tube
- 20 at the Seal Table are the sensing points. Reference line tubing runs from these points to High Volume Sensors which isolate the RCS from the remainder of the RVLIS tubing. Capillary tubing runs from the High Volume Sensors through the Containment Wall to hydraulic isolators. RTDs are installed on capillary lines for Containment temperature compensation.
PSMS receives transmitter output. Reading is invalid if RCPs are running.
2RCS-LT1321 senses Reactor Vessel Head between the top of the Reactor Vessel Head elevation 746' 9" to Thimble Guide Tube #20 elevation 705' 9".
2-06
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS REAC-VES-LV2 UPS018 RVLIS DYNAMIC RANGE TRAIN B REACTOR VESSEL WATER LEVEL A
N/A 0
120 N/A N/A 1
PSMS RVLIS ALGORITHM SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW Y
WET Connections to the Reactor Vessel Head and Incore Instrumentation Tubes sense Reactor Vessel core and internal DP. Reference line tubing runs from the instrument tubes to High Volume Sensors which isolate the RCS from the remainder of the RVLIS tubing. Capillary tubing runs from the High Volume Sensors through the Containment Wall to hydraulic isolators. RTDs are installed on capillary lines for Containment temperature compensation.
PSMS receives transmitter output. Reading is invalid unless RCPs are running. 2RCS-LT1322 senses DP across Reactor Vessel core and internals when any RCPs are running. normal DP is 110-112%.
2-07
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:.
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CTMNT-SP-NR1 L0100A" CNMT SUMP LVL DAS-LT220 CTMNT SUMP NARROW RANGE LEVEL A
INCHES LINEAR 0
12 TNKBOT N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 3.0 IN N/A N/A LOW N
N/A Containment Sump Narrow Range level measures the 12 Inch floor recess (2DAS-TK204) located at the East side of Containment adjacent to the wall on elevation 692' 11". The sump has a volume of 258 Gallons or 21.5 Gallons/Inch. 2DAS-LE220 located in the East side of Containment adjacent to the wall at elevation 692' 11" (2DAS-LT222 located in the Service Building 730' elevation). Zero reference: tank bottom.
Ref: Op Manual Chapter 9, 10080-TLD-009-032.
2-08
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CTMNT-SP-NR2 LO102A CNMT SUMP LVL DAS-LT222 CTMNT SUMP NARROW RANGE LEVEL A
INCHES LINEAR 0
12 TNKBOT N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 3.0 IN N/A N/A LOW N
N/A Containment sump Narrow Range level measures the 12 Inch floor recess (2DAS-TK204) located at the East side of Containment adjacent to the wall on elevation 692' 11". The sump has a volume of 258 Gallons or 21.5 Gallons/Inch. 2DAS-LE222 located in the East side of Containment adjacent to the wall at elevation 692' 11" (2DAS-LT222 located in the Service Building 730' elevation). Zero reference tank bottom.
Ref: Op Manual Chapter 9, 10080-TLD-009-045.
2-09
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:,
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS SG-LEVEL-1A L0403A SG 21A WR LVL FWS-LT477 STEAM GENERATOR A WATER LEVEL A
LINEAR 0
100 UTUBES SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH ALM @ 65 %/LO ALM @ 43 %
N/A N/A LOW N
N/A 2FWS-LT477 provides SG A Wide Range Level indication at the Main Control Board, Shutdown Panel, Alternate Shutdown Panel and at the Feedwater Control Valves. 2FWS-LT477 senses level in SG A from 789' 11 11/16" (upper tap) to 742' 1/16" (lower tap). Top of SG A U-Tubes is at 775' 9 1/16" with normal water level at 783' 2". Ref: Op. Manual Chapter 24A; RK-313R; TLD-24A-051.
2-10
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
9/16/2006 BV2 PCS SG-LEVEL-2B L0423A SG 21B WR LVL FWS-LT487 STEAM GENERATOR B WATER LEVEL A
LINEAR Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
0 100 UTUBES SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A
.SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH ALM @ 65 %/LO ALM @ 43 %
N/A N/A LOW N
N/A 2FWS-LT487 provides SG B Wide Range Level indication at the Main Control Board, Shutdown Panel, Alternate Shutdown Panel and at the Feedwater Control Valves. 2FWS-LT487 senses level in SG B from 789' 11 1/16" (upper tap) to 741' 11 7/8" (lower tap). Zero
Reference:
Top of SG B U-Tubes is at 775' 8 7/8" with normal water level at 783' 1 3/4". Ref: Op. Manual Chapter 24A; RK-313V; TLD-24A-059.
2-11
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS SG-LEVEL-3C L0443A SG 21C WR LVL FWS-LT497 STEAM GENERATOR C WATER LEVEL A
LINEAR 0
100 UTUBES SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH ALM @ 65 %/LO ALM @ 43 %
N/A N/A LOW N
N/A 2FWS-LT497 provides SG C Wide Range Level indication at the Main Control Board, Shutdown Panel and at the Feedwater Control Valves. 2FWS-LT497 senses level in SG C from 790' 5 1/2" (upper tap) to 742' 1/8" (lower tap).
Zero
Reference:
Top of SG C U-Tubes is at 775' 9 1/8" with normal water level at 783' 2". Ref: Op. Manual Chapter 24A; RK-313Z; TLD-24A-066.
2-12
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
Nl-Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/21/2007 BV2 PCS BWST-LEVEL1 L0500A RWST LVL QSS-LT1 OA BORATED WATER STORAGE TANK LEVEL A
INCHES LINEAR 0
730 COMPLX SEE UNIQUE SYSTEM DESCRIPTION FIELD
'S 1
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD LO ALM @ 716.5 IN / HI ALM @ 721 IN N/A N/A LOW N
N/A The BWST at BV2 is referred to as "Refueling Water Storage Tank" (RWST).
There is one RWST at BV2 with a capacity of 911,000 Gallons. There are 31,823 unusable Gallons below the Quench Spray Pump suction. There are approximately 1250 Gallons/Inch in the RWST. (see attached tank curve).
2QSS-LT100A senses level 12" from the bottom of the tank and 14" below the top of the Quench Spray Pump suction line. Zero reference 12" from bottom of BWST. Ref: MSP-2-13.11-1; 10080-TLD-13B-001; LSK-27-9D; LSK-29-6B; RK-325R.
2-13
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
8/21/2007 BV2 PCS BWST-LEVEL2 L0501A RWST LVL QSS-LT100B BORATED WATER STORAGE TANK LEVEL A
INCHES LINEAR 0
730 COMPLX SEE UNIQUE SYSTEM DESCRIPTION FIELD S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD LO ALM @ 716.5 IN / HI ALM @ 721 IN N/A N/A LOW N
N/A The BWST at BV2 is referred to as "Refueling Water Storage Tank" (RWST).
There is one RWST at BV2 with a capacity of 911,000 Gallons. There are 31,823 unusable Gallons below the Quench Spray Pump suction. There are approximately 1250 Gallons/Inch in the RWST. (see attached tank curve).
2QSS-LT100B senses level 12" from the bottom of the tank and 14" below the top of the Quench Spray Pump suction line. Zero reference 12" from bottom of BWST. Ref: MSP-2-13.11-1; 10080-TLD-13B-002; LSK-27-9D; LSK-29-6B; RK-325Q.
2-14
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CTMNT-SP-WR1 L0750A RX CNMT SUMP LVL RSS-LT151A CTMNT SUMP WIDE RANGE LEVEL A
INCHES LINEAR 0
225 CNTFLR SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 35 IN N/A N/A LOW N
N/A 2RSS-LT151A measures Containment Sump level from the floor to a height of 709' 10 3/8". 2RSS-P21A thru D suction lines are at the 692' 11" level in containment. At 695' the Containment Air Recirculation A and C Fans trip.
2RSS-LT151A measures level from the Containment Floor at elevation 691' 1 3/8" to a height of 709' 10 3/8". Zero reference: Containment Floor (691' 1 3/8"). Ref: MSP-2-13.09, 10080-TLD-13A-003; RK-6M; Op. Manual Chapter 13.
2-15
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CTMNT-SP-WR2 L0751A RX CNMT SUMP LVL RSS-LT151B CTMNT SUMP WIDE RANGE LEVEL A
INCHES LINEAR 0
225 CNTFLR SEE UNIQUE SYSTEM DESCRIPTION FIELD S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 35 IN N/A N/A LOW N
N/A 2RSS-LT151B measures Containment Sump level from the floor to a height of 709' 10 3/8". 2RSS-P21A thru D suction lines are at. the 692' 11" level in containment. At 695' the Containment Air Recirculation B and C Fans trip.
2RSS-LT151B measures level from the Containment Floor at elevation 691' 1 3/8" to a height of 709' 10 3/8". Zero reference: Containment Floor (691' 1 3/8"). Ref: MSP-2-13.09, 10080-TLD-13A-003; RK-6M; Op. Manual Chapter 13.
2-16
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr IRange:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS NI-SOURC-RNG N0031A SOURCE RNG DET I FLUX-LOG NM31F NUCLEAR INSTRUMENTSSOURCE RANGE A
CPS eA(2.763102E-03
- mv) 1 1 E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A in mode 1, mode 2 = 9.OE+03 1/21NTRNG>IE-10 2/21NTRNG<IE-10 LOW N
N/A The Source Range provides power level indication from about 1OE-10% to 1OE-4%. Source Range power level is calibrated from 1 to 1.0E6 Counts per Second. 2NMS-NE31 (see attached NIS detector location dwg) Ref: Op Manual Chapter 2; 10080-TLD-02-001.
2-17
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS EXTRA5 N0032A SOURCE RNG DET 2 FLUX-LOG NM32F NUCLEAR INSTRUMENTS,SOURCE RANGE A
CPS eA(2.763102E-03
- mv) 1 1E6 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A in mode 1, mode 2 = 9.OE+03 1/21NTRNG>IE-10 2/21NTRNG<IE-10 LOW N
N/A The Source Range provides power level indication from about 1OE-10% to 10E-4%. Source Range power level is calibrated from 1 to 1.0E6 Counts per Second. 2NMS-NE32 (see attached NIS detector location dwg) Ref: Op Manual Chapter 2; 10080-TLD-02-002.
2-18
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
1/7/2008 BV2 PCS NI-INTER-RNG N0035A INT RNG DET 1 FLUX-LOG NM35B NUCLEAR INSTRUMENTS, INT RANGE A
AMP EU=eA[(3.684138E-03 *mv)+(-2.532840E+01) 1E-11 1 E-3 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI =9.5E-04 2/4 PWRRNG >10%
3/4 PWRRNG <10%
LOW N
N/A Intermediate Range level indication from 1.0E-1 1 to 1.OE-3 Amps corresponds to about 1OE-6% to 10E2% full rated power.. Power Range level indication will not come on scale until the Reactor power rises to about 1OE-5 Amps Intermediate Range level (- 1% full power). 2NMI-NE35 (see attached NIS detector location dwg). Ref: Op Manual Chapter 2; 10080-TLD-02-003.
2-19
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
1/7/2008 BV2 PCS EXTRA4 N0036A INT RNG DET 2 FLUX-LOG NM36B NUCLEAR INSTRUMENTS, INT RANGE A
AMP EU=eA[(3.684138E-03 *mv)+(-2.532840E+01) 1E-11 1 E-3 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI = 9.5E-04 2/4 PWRRNG >10%
3/4 PWRRNG <10%
LOW N
N/A Intermediate Range level indication from 1.OE-1 1 to 1.OE-3 Amps corresponds to about 1OE-6% to 10E2% full rated power. Power Range level indication will not come on scale until the Reactor power rises to about 10E-5 Amps Intermediate Range level (- 1% full power). 2NMI-NE36 (see attached NIS detector location dwg). Ref: Op Manual Chapter 2; 10080-TLD-02-004.
2-20
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS NI-POWER-RNG N0049A PWR RNG CHAN 1 FLUX NM41F NUCLEAR INSTRUMENTS, POWER RANGE A
LINEAR 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 101%/LO ALM @ 0.1%
N/A N/A LOW N
N/A Power Range level is calibrated from a secondary plant calorimetric calculation to provide full rated power level. Power Range level is an average of the upper and lower detector flux levels. 2NMP-NE41A and B (see attached NIS detector location dwg). Ref: Op Manual Chapter 2; 10080-TLD-02-005.
2-21
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS EXTRA1 N0050A PWR RNG CHAN 2 FLUX NM42F NUCLEAR INSTRUMENTS, POWER RANGE A
LINEAR 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 101%/LO ALM @ 0.1%
N/A N/A LOW N
N/A Power Range level is calibrated from a secondary plant calorimetric calculation to provide full rated power level. Power Range level is an average of the upper and lower detector flux levels. 2NMP-NE42A and B (see attached NIS detector location dwg). Ref: Op Manual Chapter 2; 10080-TLD-02-006.
2-22
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
9/16/2006 BV2 PCs EXTRA2 N0051A PWR RNG CHAN 3 FLUX NM43F NUCLEAR INSTRUMENTS, POWER RANGE A
LINEAR 0
120 N/A N/A S
1 How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 101%/LO ALM @ 0.1%/o N/A N/A LOW N
N/A Power Range level is calibrated from a secondary plant calorimetric calculation to provide full rated power level. Power Range level is an average of the upper and lower detector flux levels. 2NMP-NE43A and B (see attached NIS detector location dwg). Ref: Op Manual Chapter 2; 10080-TLD-02-007.
2-23
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS EXTRA3 N0052A PWR RNG CHAN 4 FLUX NM44F NUCLEAR INSTRUMENTS, POWER RANGE A
LINEAR 0
120 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 101%/LO ALM @ 0.1%
N/A N/A LOW N
N/A Power Range level is calibrated from a secondary plant calorimetric calculation to provide full rated power level. Power Range level is an average of the upper and lower detector flux levels. 2NMP-NE44A and B (see attached NIS detector location dwg). Ref: Op Manual Chapter 2; 10080-TLD-02-008.
2-24
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS COND-AE-RAD1 R0001A AIR EJ DISCHARGE 2ARC-RQ100 COND AIR EJECTOR RADIOACTIVITY A
uCI/CC N/A 0
1.0 N/A N/A P
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2ARC-RQ100 monitors the gaseous effluent from the Condenser Air Ejector discharge for Xe-1 33 before the Charcoal Delay Beds. An alarm indicates a primary to secondary leak. Detector output is sent to digital radiation monitor system (DRMS) which transmits value and measurement condition once per minute to the PCS. A beta scintillation detector monitors the Condenser Air Ejector discharge upstream of the Charcoal Delay Beds. Ref: Op Manual Chapter 43, RM-419-2, TLD-43-056.
2-25
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
.Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS RCS-LTD-RAD2 R0002A RX CLNT LTDN LO RNG 2CHS-RQ101A RAD LEVEL OF RCS LETDOWN LINE A
uCl/CC N/A 0
1.0E2 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2CHS-RQ101A monitors the gross activity of the reactor coolant (Cs-1 37) by drawing samples from the Reactor Coolant Letdown Line and delaying them to permit sufficient decay of the N-16 isotope before they pass by the detectors. This is an indication of fission products present in the reactor coolant. This radiation monitor provides the Low Range indication. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A detector monitors gross activity of the reactor coolant at Reactor Coolant Letdown Line.
2-26
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS RCS-LTD-RAD1 R0003A RX CLNT LTDN HI RNG 2CHS-RQ101B RAD LEVEL OF RCS LETDOWN LINE A
uCIlCC N/A 0.0 1.0E5 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2CHS-RQ101B monitors the gross activity of the reactor coolant (Cs-137) by drawing samples from the Reactor Coolant Letdown Line and delaying them to permit sufficient decay of the N-1 6 isotope before they pass by the detectors. This is an indication of fission products present in the reactor coolant. This radiation monitor provides the High Range indication. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A detector monitors gross activity of the reactor coolant at Reactor Coolant Letdown Line.
2-27
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
AnaloglDigital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCs COND-AE-RAD2 R0010A AIR EJ DELAY BED 2GWS-RQ102 COND AIR EJECTOR RADIOACTIVITY A
uCI/CC N/A 0
1.0 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2GWS-RQ102 monitors the gaseous effluent from the Air Ejector Charcoal Bed for Xe-1 33. An alarm indicates a primary to secondary leak and a possible malfunction of the Charcoal Delay Beds. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A beta scintillation detector monitors Air Ejector Charcoal Bed gaseous effluent.
Ref: Op Manual Chapter 43; RM-443-17; TLD-43-062.
2-28
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minirrium Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS SG-BD-RAD-1A R0079A SG BLOWDOWN 2SSR-RQ100 STM GEN A/B/C BLOWDOWN RAD LEVEL A
uCl/CC N/A 0.0 1.0 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2SSR-ROI100 monitors the activity of the Steam Generator Blowdown for Cs-137. Samples aretaken from a common header which acts as a manifold from the three Steam Generators. A High Alarm isolates the sample lines.
The sampling valve arrangement permits the operator to determine the source of the high activity. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator monitors the activity of the Steam Generator Blowdown effluent in a common header from all three Steam Generators.
2-29
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig'States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CTMNT-RAD1 R0086A IN-CNMT HI RNG AREA 2RMR-RQ206 RADIATION LEVEL IN CONTAINMENT A
R/HR N/A 0.0 1E9 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2RMR-RQ206 monitors the radiation levels inside Containment and provides both local and Control Room alarms and indication. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. An ion chamber detects High Range area radiation levels inside Containment. Ref: Op Manual Chapter 43; TLD-43-017.
2-30
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip-Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CTMNT-RAD2 R0087A IN-CNMT HI RNG AREA 2RMR-RQ207 RADIATION LEVEL IN CONTAINMENT A
R/HR N/A 0.0 1E9 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2RMR-RQ207 monitors the radiation levels inside Containment and provides both local and Control Room alarms and indication. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmitsvalue and measurement condition once per minute to the PCS. An ion chamber detects High Range area radiation levels inside Containment. Ref: Op Manual Chapter 43; TLD-43-018.
2-31
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS MAIN-SL-1A R0088A MAIN STM ACTIVITY 2MSS-RQ101A STM GEN A STEAM LINE RAD LEVEL A
uCl/CC N/A 0.0 1.0E4 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2MSS-RQ101A monitors the activity (Kr-88) following an accident in which the Power-Operated Dump Valves or Main Steam Safety Valves may be used as a discharge path to the environment. This monitor is activated by a Safety Injection Signal. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator detects activity in the Main Steam Line between SG A and the Main Steam Trip Valves upstream of the Safety Valve tie-in. Ref: Op Manual Chapter 43; TLD-43-071; RM-421-2.
2-32
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS MAIN-SL-2B R0089A MAIN STM ACTIVITY 2MSS-RQ101B STM GEN B STEAM LINE RAD LEVEL A
uCI/CC N/A 0.0 1.0E4 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2MSS-RQ101B monitors the activity (Kr-88) following an accident in which the Power-Operated Dump Valves or Main Steam Safety Valves may be used as a discharge path to the environment. This monitor is activated by a Safety Injection Signal. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator detects activity in the Main Steam Line between SG B and the Main Steam Trip Valves upstream of the Safety Valve tie-in. Ref: Op Manual Chapter 43; TLD-43-075; RM-421-2.
2-33
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS MAIN-SL-3C R0090A MAIN STM ACTIVITY 2MSS-RQ101C STM GEN C STEAM LINE RAD LEVEL A
uCI/CC N/A 0.0 1.0E4 N/A N/A P
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2MSS-RQ101C monitors the activity (Kr-88) following an accident in which the Power-Operated Dump Valves or Main Steam Safety Valves may be used as a discharge path to the environment. This monitor is activated by a Safety Injection Signal. Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator detects activity in the Main Steam Line between SG C and the Main Steam Trip Valves upstream of the Safety Valve tie-in. Ref: Op Manual Chapter 43; TLD-43-076; RM-421-2 2-34
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS EFF-LIQ-RAD1 R0094A LIQ WST EFFLUENT 2SGC-RQ100 RADIOACTIVITY OF RELEASED LIQ A
uCI/CC N/A 0.0 1.OE-1 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A 2SGC-RQ100 receives an auto-start signal and monitors the activity (Cs-137) in the Liquid Waste Process System when flow is detected. Upon detection of High radiation a valve is closed to prevent the release of this discharge.
Detector output is sent to Digital Radiation Monitor System (DRMS) which transmits value and measurement condition once per minute to the PCS. A gamma scintillator detects activity in the discharge from the Liquid-Waste Process System. Ref: Op Manual Chapter 43; TLD-43-048 2-35
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CL-TEMP-1A T0406A RCL A WIDE RANGE TCOLD RCS-TE410 STM GEN A OUTLET TEMPERATURE A
DEGF LINEAR 0
700 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH ALM @ 630; LO ALM @ 530 N/A N/A LOW N
N/A Reactor Coolant Loop A Cold Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant and PSMS computers. 2RCS-TE410 is located between 2RCS-P21A discharge and the A Loop Stop Valve. 10080-TLD-06-040; RM-75A.
2-36
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS HL-TEMP-1A T0419A RCL A WIDE RANGE THOT RCS-TE413 STM GEN A INLET TEMPERATURE A
DEGF LINEAR 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 650; LO ALM @ 541 N/A N/A LOW N
N/A Reactor Coolant Loop A Hot Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant and PSMS computers. 2RCS-TE413 is located between A Loop Stop Valve and Coolant Inlet to SG A. 10080-TLD-06-044; RM-75A.
2-37
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CL-TEMP-2B T0426A RCL B WIDE RANGE TCOLD RCS-TE420 STM GEN B OUTLET TEMPERATURE A
DEGF LINEAR 0
700 N/A N/A S
I N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH ALM @ 630; LO ALM @ 530 N/A N/A LOW N
N/A Reactor Coolant Loop B Cold Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant and PSMS computers. 2RCS-TE420 is located between 2RCS-P21B discharge and the B Loop Stop Valve. 10080-TLD-06-056; RM-75A.
2-38
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr. Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS HL-TEMP-2B T0439A RCL B WIDE RANGE THOT RCS-TE423 STM GEN B INLET TEMPERATURE A
DEGF LINEAR 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 650; LO ALM @ 541 N/A N/A LOW N
N/A Reactor Coolant Loop B Hot Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant and PSMS computers. 2RCS-TE423 is located between B Loop Stop Valve and Coolant Inlet to SG B. 10080-TLD-06-060; RM-75A.
2-39
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
.Reactor. Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CL-TEMP-3C T0446A RCL C WIDE RANGE TCOLD RCS-TE430 STM GEN C OUTLET TEMPERATURE A
DEGF LINEAR 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 630 DEGF; LO ALM @ 530 DEGF N/A N/A LOW N
N/A Reactor Coolant Loop C Cold Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant and PSMS computers. 2RCS-TE430 is located between 2RCS-P21C discharge and the C Loop Stop Valve. 10080-TLD-06-072; RM-75A.
2-40
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
.'Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS HL-TEMP-3C T0459A RCL C WIDE RANGE THOT.
RCS-TE433 STM GEN C INLET TEMPERATURE A
DEGF LINEAR 0
700 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 650; LO ALM @ 541 N/A N/A LOW N
N/A Reactor Coolant Loop C Hot Leg temperature signal is sent to the Main Control Board, Remote Shutdown Panel, and the plant and PSMS computers. 2RCS-TE433 is located between C Loop Stop Valve and Coolant Inlet to SG C. 10080-TLD-06-076; RM-75A.
2-41
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant SpecPoint Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CTMNT-TEMP T1002A RX CNMT TEMP LMS-TE100-2 CONTAINMENT TEMPERATURE A
DEGF LINEAR 0
300 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 121.3 DEGF; LO ALM @ 80.7 DEGF N/A N/A HIGH N
N/A 2LMS-TE100-2 measures Containment temperature inside the Crane Wall.
See attached drawing for detector locations in Containment. 2LMS-TE100-2 senses Containment temperature at 801' 6" elevation inside the Crane Wall.
Ref:10080-TLD-12B-007; RK-14A.
2-42
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS EXTRA12 T1008A RX CNMT TEMP LMS-TE100-8 CONTAINMENT TEMPERATURE A
DEGF N/A 50 130 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 106.3 DEGF; LO ALM @ 79.5 DEGF N/A N/A HIGH N
N/A 2LMS-TE100-8 measures Containment temperature inside the Crane Wall.
See attached drawing for detector locations in Containment. 2LMS-TE100-8 senses temperature in Containment at 743' elevation inside theCraneWall.
Ref:10080-TLD-12B-013; RK-14A.
/
2-43
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS EXTRA13 T1013A RX CNMT TEMP LMS-TE100-13 CONTAINMENT TEMPERATURE A
DEGF LINEAR 0
300 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 123.9 DEGF; LO ALM @ 83.4 DEGF N/A N/A HIGH N
N/A 2LMS-TE100-13 measures Containment temperature inside the Crane Wall.
See attached drawing for detector locations in Containment. 2LMS-TE100-13 senses temperature in Containment at 802' elevation inside the Crane Wall.
Ref:10080-TLD-12B-018; RK-14A.
2-44
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc,:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
1/25/2007 BV2 PCS EXTRA14 T1014A RX CNMT TEMP LMS-TE100-14 CONTAINMENT TEMPERATURE A
DEGF LINEAR 0
300 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 93.8 DEGF; LO ALM @ 74.9 DEGF N/A N/A HIGH N
N/A 2LMS-TE100-4 measures Containment temperature outside the Crane Wall.
See attached drawing for detector locations in Containment. 2LMS-TE100-14 senses temperature in Containment at 701' 6" elevation outside the Crane Wall. Ref:10080-TLD-12B-019, RK-14A.
2-45
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/DigitaiL Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:'
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS EXTRA 15 T1015A RX CNMT TEMP LMS-TE100-15 CONTAINMENT TEMPERATURE A
DEGF LINEAR 0
300 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 132.4 DEGF; LO ALM @ 80.0 DEGF N/A N/A HIGH N
N/A 2LMS-TE100-5 measures Containment temperature outside the Crane Wall.
See attached drawing for detector locations in Containment. 2LMS-TE100-15 senses temperature in Containment at 777' 4" elevation outside the Crane Wall. Ref:10080-TLD-12B-020; RK-14A.
2-46
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply.Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS MN-FD-FL-1A U0410 LOOP A CORR FW FLW AVG 1+2 STM GEN A MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0000 N/A N/A P
2 REF SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This value is the average of two flow signals sensed from the venturi flow element 2FWS-FE476. There are two, half capacity, Main Feed Pumps which have a design flow rate of 15,200 GPM at 1,694 ft. Total Design Head (TDH) each. 2FWS-FT476 and 2FWS-FT477 sense flow to SG A between the Main Feed Pump discharge and the Main Feed Regulating Valve. 10080-TLD-24A-052; 10080-TLD-24A-050; RM-45A.
2-47
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS MN-FD-FL-2B U0430 LOOP B CORR FW FLW AVG 1+2 STM GEN B MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0000 N/A N/A P
2 REF SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This value is the average of two flow signals sensed from the venturi flow element 2FWS-FE486. There are two, half capacity, Main Feed Pumps which have a design flow rate of 15,200 GPM at 1,694 ft. Total Design Head (TDH) each. 2FWS-FT486 and 2FWS-FT487 sense flow to SG B between the Main Feed Pump discharge and the Main Feed Regulating Valve. 10080-TLD-24A-057; 10080-TLD-24A-058; RM-45A.
2-48
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS MN-FD-FL-3C U0450 LOOP C CORR FW FLW AVG 1+2 STM GEN C MAIN FEEDWATER FLOW A
MLB/HR N/A 0
5.0000 N/A N/A P
2 REF SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This value is the average of two flow signals sensed from the venturi flow element 2FWS-FE496. There are two, half capacity, Main Feed Pumps which have a design flow rate of 15,200 GPM at.1,694 ft. Total Design Head (TDH) each. 2FWS-FT496 and 2FWS-FT497 sense flow to SG C between the Main Feed Pump discharge and the Main Feed Regulating Valve. 10080.
TLD-24A-064; 10080-TLD-24A-065; RM-45A.
2-49
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant-Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS HPSI-FLOW1 UF1011 HI SI FLOW TOTAL HIGH PRESS SAFETY INJECTION FLOW A
GPM N/A 0
2000 N/A N/A P
2 ADD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N'
N/A This value is the total flow through the Train A and B High Pressure Safety Injection Lines. The Charging Pumps (2CHS-P21A, B and C) provide the HHSI flow. 2SIS-FT940 (Train A) and 2SIS-FT943 (Train B) sense flow at the discharge of 2CHS-P21A, B and C prior to the header connection to the Hot and Cold Legs of Reactor Coolant Loops A, B and C. 10080-TLD-1 1A-038; 10080-TLD-11A-039; RM-407-1; RM-411-1.
2-50
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS RCS-CHG-MU UF1013 TOTAL CHARGING FLOW PRIMARY SYSTEM CHG OR MU FLOW A
- GPM N/A 0
195 N/A N/A P
4 ADD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A Total Charging Flow is computed on the Plant Computer by adding the CHG LINE FLW CHS-FT122 (F0128A), and the three RCP SEAL INJECTION flows (FO131A, RCP 21A SEAL INJ FLOW CHS-FT130; F0129A, RCP 21B SEAL INJ FLOW CHS-FT127; and F0127A, RCP 21C SEAL INJ FLOW CHS-FT124).
2-51
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:,
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS LPSI-FLOW1 UF1014 LO SI FLOW TOTAL LOW PRESS SAFETY INJECTION FLOW A
GPM N/A 0
10000 N/A N/A P
2 ADD SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This value is total flow through Train A and B Low Pressure Safety Injection Header or Safety Injection Flow from Recirculation Spray Pumps to Reactor Coolant Loops A, B and C. Pumps 2SIS-P21A and B have a design flow rate of 3000 GPM at 240 PSIG with a shutoff head of 350'. The Recirculation Pumps Pumps (2RSS-P21A, B, C and D) have a design flow rate of 3500 GPM at 280f and 266 FT. 2SIS-FT945 (Train A) and 2SIS-FT946 (Train B) sense flow at the discharge of the LHSI Pumps (2SIS-P21A and B) between the Recirculation Spray Pump connection to the injection header and the header connection to the Hot and Cold Legs for Reactor Coolant Loops A, B and C.
2-52
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS AX-FD-FL-1A UF3000 AFW FLOW TO SG A STM GEN A AUXILLIARY FW FLOW A
GPM N/A 0
400 N/A N/A P
2 DAVE SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This value is the average of two flow signals sensed from the same flow element located before the A Auxiliary Feed Line Containment Penetration.
The Auxiliary Feedwater system consists of two half size Motor Driven Feed Pumps (375 GPM at 2760 TDH) and one full size'Turbine Driven Feed Pump (750 GPM at 2760 TDH) which take a suction on the 152,000 Gallon Primary Plant Demineralized Water Storage Tank. 2FWE-FT100A and 2FWE-FT100A1 sense flow between the Auxiliary Feedwater Throttle Valves and SG A. The Auxiliary Feedwater Line taps into the Main Feed Line between the Feedwater Isolation Valve and SG A.
2-53
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS AX-FD-FL-2B UF3001 AFW FLOW TO SG B STM GEN B AUXILLIARY FW FLOW A
GPM N/A 0
400 N/A N/A P
2 DAVE SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A, LOW N
N/A This value is the average of two flow signals sensed. from the same flow element located before the B Auxiliary Feed Line Containment Penetration.
The Auxiliary Feedwater system consists of two half size Motor Driven Feed Pumps (375 GPM at 2760 TDH) and one full size Turbine Driven Feed Pump (750 GPM at 2760 TDH) which take a suction on the 152,000 Gallon Primary Plant Demineralized Water Storage Tank. 2FWE-FT100B and 2FWE-FT100B1 sense flow between the Auxiliary Feedwater Throttle Valves and SG B. The Auxiliary Feedwater Line taps into the Main Feed Line between the Feedwater Isolation Valve and SG B.
2-54
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Tuarn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS AX-FD-FL-3C UF3002 AFW FLOW TO SG C STM GEN C AUXILLIARY FW FLOW A
GPM N/A 0
400 N/A N/A P
2 DAVE SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This value is the average of two flow signals sensed from the same flow element located before the C Auxiliary Feed Line Containment Penetration.
The Auxiliary Feedwater system consists of two half size Motor Driven Feed Pumps (375 GPM at 2760 TDH) and one full size Turbine Driven Feed Pump (750 GPM at 2760 TDH) which take a suction on the 152,000 Gallon Primary Plant Dernineralized Water Storage Tank. 2FWE-FT100C and 2FWE-FT100C1 sense flow between the Auxiliary Feedwater Throttle Valves and SG C. The Auxiliary Feedwater Line taps into the Main Feed Lirie between the Feedwater Isolation Valve and SG C.
2-55
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument FailureMode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS PRZR-LEVEL U0483 AVERAGE PZR LEVEL (1/2/3)
PRIMARY SYSTEM PRESSURIZER LEVEL A
N/A 0
100 TOPHTR SEE UNIQUE SYSTEM DESCRIPTION FIELD P
3 CHAU SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A, LOW N
N/A The indicated level can be the average of three, two or one level transmitter signal depending on the deviation between values. See attached curve of %
level vs Pressurizer volume in Gallons. 2RCS-LT459, 460 and 461 sense Pressurizer level from 748' 3 3/4" (lower transmitter tap) to 780' 10 9/16" (upper transmitter tap). Zero reference: minimum water level (top of Heaters) is at 752' 1 5/8" or approximately 12%. Ref: Op Manual Chapter 6; 2004.150-001-010; RK-326R; RK-326S; RK-326T.
2-56
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS CTMNT-PRESS UP1000 CNMT PRESS AVG CONTAINMENT PRESSURE A
PSIA N/A 0
180 N/A N/A P
2 DAVE SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This signal is an average of two Containment pressure signals. The design pressure of the BV2 Reactor Containment is 8 PSIG to 45 PSIG. 2LMS-PT106A and 2LMS-PT106B sense Containment pressure from an open tap in Containment. Ref: 10080-TLD-12B-034; 10080-TLD-12B-035; RK-321 H; RK-321K.
2-57
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS RCS-PRESSURE UPS026 RCS WIDE RANGE PRESSURE REACTOR COOLANT SYSTEM PRESSURE A
PSIG N/A 0
3000 N/A N/A P
3 INPUT FROM PSMS SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This signal is an average of three Wide Range RCS pressure signals. 2RCS-PT440 and 442 senses pressure at Loop A Hot Leg RVLIS tap located between Loop A Hot Leg Isolation Valve and the Reactor Vessel. 2RCS-PT441 senses pressure at Loop B Hot Leg RVLIS tap located between the Loop B Hot Leg Isolation Valve and the Reactor Vessel. 10080-TLD-06-004; 10080-TLD-06-005; 10080-TLD-05D-008; RK-25G; RK-25E.
ý 2-58
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
- Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS SG-PRESS-1A U0414 STM GEN A STM OUT P BELV 1 2+3 STEAM GENERATOR A PRESSURE A
PSIG N/A 0
1200 N/A N/A P
3 CHAU SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This signal is an average of the three Main Steam Line pressure sensors.
The Atmospheric Steam Dump Valves trip open at 1060 PSIG. The Main Steam Safety Valves begin lifting at 1075 PSIG. 2MSS-PT474, 2MSS-PT475 and 2MSS-PT476 sense pressure at SG A Main Steam Line between the Safety Relief Valves and the Main Steam Line Isolation Valves. 10080-TLD-21A-010; RM-421-1.
2-59
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS SG-PRESS-2B U0434 STM GEN B STM OUT P BELV 1 2+3 STEAM GENERATOR B PRESSURE A
PSIG N/A 0
1200 N/A N/A P
3 CHAU SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This signal is an average of the three Main Steam Line pressure sensors.
The Atmospheric Steam Dump Valves trip open at 1060 PSIG. The Main Steam Safety Valves begin lifting at 1075 PSIG. 2MSS-PT484, 2MSS-PT485 and 2MSS-PT486 sense pressure at SG B Main Steam Line between the Safety Relief Valves and the Main Steam Line Isolation Valves. 10080-TLD-21A-011; RM-421-1.
2-60
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
-Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS SG-PRESS-3C U0454 STM GEN C STM OUT P BELVI 2+3 STEAM GENERATOR C PRESSURE A
PSIG N/A 0
1200 N/A N/A P
3 CHAU SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This signal is an average of the three Main Steam Line pressure sensors.
The Atmospheric Steam Dump Valves trip open at 1060 PSIG. The Main Steam Safety Valves begin lifting at 1075 PSIG. 2MSS-PT494, 2MSS-PT495 and 2MSS-PT496 sense pressure at SG C Main Steam Line between the Safety Relief Valves and the Main Steam Line Isolation Valves. 10080-TLD-21A-020; RM-421-1.
2-61
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS SUB-MARGIN1 UPS012 TSAT MARGIN (SUBCOOLING)
SATURATION TEMP - HIGHEST CET A
DEGF N/A
-200 35.0 N/A N/A P
0 INPUT FROM PSMS SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A This point is received by the PCS from Plant Safety Monitoring System (PSMS) as PCS point UPS012.
2-62
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS TMP-CORE-EX1 UPS001 HIGHEST T/C TEMPERATURE HIGHEST TEMPERATURE AT CORE EXIT A
DEGF N/A 100 2200 N/A N/A P
51 EXTR SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A LOW N
N/A PCS accepts the inputs of the compensated Core Exit Thermocouples (51 total) via data link from the Plant Safety Monitoring System (PSMS). This value is computed in PSMS and transmitted to the PCS via data link.
2-63
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS H2-CONC1 Y0752A CNMT H2 CONC TRN A HCS-HA100A CONTAINMENT HYDROGEN CONC A
N/A 0
10 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 0.5 %
N/A N/A LOW N
N/A Containment gas is sampled and analyzed at the Hydrogen Analyzer (2HCS-HA100A) with the results transmitted to 2HCS-PNL100A where % hydrogen is calculated. 2HCS-HA100A senses hydrogen at the 801' level in Containment. 10080-TLD-46-001; RK-317C; RM-446-1.
2-64
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 PCS EXTRA 16 Y0753A CNMT H2 CONC TRN B HCS-HA100B CONTAINMENT HYDROGEN CONC A
N/A 0
10 N/A N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HI ALM @ 0.5 %
N/A N/A LOW N
N/A Containment gas is sampled and analyzed at the Hydrogen Analyzer (2HCS-HA100B) with the results transmitted to-2HCS-PNL100B where % hydrogen is calculated. 2HCS-HA100B senses hydrogen at the 802' level in Containment. 10080-TLD-46-002; RK-317C; RM-446-1.
2-65
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS WIND-SPEED1 XM006 WIND SPEED 35' ELEVATION WIND SPEED AT THE REACTOR SITE A
MPH N/A 0
50 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments, as ground level speed.
Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 2-66
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS WIND-SPEED2
.XM026 WIND SPEED 500' ELEVATION WIND SPEED AT THE REACTOR SITE A
MPH N/A 0
50 N/A N/A P
2 FAILOVER. SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is the 15 minute average value for primary sensor. Redundant sensor substituted if primary bad or missing. Sensors are same quality/calibration.
Value is dose assessments as elevated wind speed. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 2-67
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS WIND-DIR1 XM051 WIND DIRECTION 150' ELEVATION WIND DIRECTION AT REACTOR SITE A
DEGFR N/A 0
360 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments as ground level direction. Wind direction 0 isNorth. Wind direction is direction from which wind is coming. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 2-68
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS WIND-DIR2 XM061 WIND DIRECTION 500' ELEVATION WIND DIRECTION AT REACTOR SITE A
DEGFR N/A 0
360 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is the 15 minute average value for primary sensor. Redundant sensor value substituted if primary bad or missing. Sensors are same quality/calibration. Value used in dose assessments as ground level direction. Wind direction 0 is North. Wind direction is direction from which wind is coming. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 2-69
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS STAB-CLASS 1 XM083 STABILITY-GROUND LEVEL AIR STABILITY AT REACTOR SITE A
STABI N/A 1
7 N/A N/A P
2 FAILOVER SUBSTITUTION.
SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is based on 15 minute average Delta-T for 35' and 150' temperature sensors. Based on redundant sensor if primary bad or missing. Sensors are same quality/calibration. Stability classes 1 thru 7 correspond to stability classes A to G. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 2-70
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:.
Unique System Desc.:
11/14/1992 BV2 ARERAS STAB-CLASS2 XM087 STABILITY-ELEVATED AIR STABILITY AT REACTOR SITE
'A STABI N/A 1
7 N/A N/A P
2 FAILOVER SUBSTITUTION SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is based on 15 minute average Delta-T for 35' and 500' temperature sensors. Based on redundant sensor if primary bad or missing. Sensors are same quality/calibration. Stability classes 1 thru 7 correspond to stability classes A thru G. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484 2-71
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON PowerLevel:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS EXTRA 15 XR013 1RM-GW-109 CH5 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=1.26E7 CPM/uCl/cc 1.0 1.2E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 3.6E5 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to 10 CFR 20 Limits at most restrictive receptor per ODCM. RM-1GW-109 Channel 5 monitors for low range noble gases at the discharge of the gaseous waste disposal blowers. This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-419-1; Calculation Package ERS-SFL-92-024; CR 04-05484 2-72
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS EXTRA16 XR014 1RM-GW-109 CH7 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=3.00E2 CPM/uCl/cc 1.0 1.2E6 N/A N/A S
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD N/A N/A N/A DEPENDS ON-FAILURE MODE N
N/A Point is 1 minute average. Site doseassessment varies CPM to uCI/cc conversion depending on which default source term was selected and decay period. RM-1GW-109 Channel 7 monitors for mid range noble gases at the discharge of the gaseous waste disposal blowers. This SPING monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-419-1; Calculation Package ERS-SFL-92-024; CR 04-05484 j
2-73
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS EXTRA 17 XR015 1RM-GW-109 CH9 RADIOACTIVITY OF RELEASED GASSES A
CPM Xe133=3.95 CPM/uCl/cc 1.0 1.2E6 N/A N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 1.83E5 CPM >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A Point is 1 minute average. Site dose assessment varies CPM to uCl/cc conversion depending on which default source term was selected and decay period. Alarm setpoint corresponds to a General Emergency if the release continues for eight hours. RM-1GW-109 Channel 9 monitors for High Range noble gases at the discharge of the Gaseous Waste Disposal Blowers. The monitor provides alarms to warn the operator of abnormal releases and provides input to compute integrated release data. Ref: Op Manual Chapter 43; RM-419-1; Calculation Package ERS-SFL-92-024; CR 04-05484 2-74
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
11/14/1992 BV2 ARERAS EFF-GAS-RAD 1 XR041.
2HVS-RQI101A RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 5.6E-1 1 5.6E-5 0
N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 1.67E-5 uCi/cc >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQI101A monitors the airborne activity between the discharge of the Leak Collection Normal Exhaust Fans and the Ventilation Vent. A High activity signal will isolate the Purge System and indicate to the operator the need to divert flow through the Filter Banks.
Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Op Manual Chapter 43; TLD-43-068; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484 2-75
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 ARERAS EFF-GAS-RAD2 XR042 2HVS-RQI101 B RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 3.7E-7 0.37 0
N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 1.81 E-4 uCi/cc >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQI101B monitors the airborne activity between the discharge of the Leak Collection Normal Exhaust Fans and the Ventilation Vent. A High activity signal will isolate the Purge System and indicate to the operator the need to divert flow through the Filter Banks.
Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Op Manual Chapter 43; TLD-43-068; RM-416-1; Calculation Package ERS-SFL-92-024; CR 04-05484.
2-76
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr.Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 ARERAS EFF-GAS-RAD3 XR045 2HVS-RQI109A RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 3.3E-1 1 3.3E-5 0
N/A S
N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 9.84E-6 uCi/cc >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. 2HVS-RQI109A monitors the airborne activity between the discharge of the Leak Collection Filter Exhaust Fans and the Elevated Release Exhaust Line. This sample is composed of effluent from the Auxiliary and Fuel Buildings, after it has passed through Main Filter Banks in the SLCRS system before being discharged to atmosphere. Note:
The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due. to minor dynamic changes to the monitor conversion factor. Ref: Op Manual Chapter 43; TLD-43-068; RM-416-2; Calculation Package ERS-SFL-92-024; CR 04-05484.
2-77
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
9/16/2006 BV2 ARERAS EFF-GAS-RAD4 Point ID:
XR046 Plant Spec Point Desc.:
Generic/Cond Desc.:
2HVS-RQI109 RADIOACTIVITY OF RELEASED GASSES Analog/Digital:
A Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
uCi/cc N/A 2.45E-7 1.OE+5 0
N/A P
1 N/A Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 1.77E3 uCi/SEC N/A NI Detector Power Supply Turn-ON Power Level:
N/A Instrument Failure Mode:
DEPENDS ON FAILURE MODE Temperature Compensation for DP Transmitters:
N Level Reference Leg:
N/A Unique System Desc.:
1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. This is a multi-range monitor. Lowest onscale channel report. 2HVS-RQI109B, C and D monitors the gaseous activity between the discharge of the leak collection filter exhaust fans and the elevated release exhaust line. This sample is composed of effluent from the Auxiliary and Fuel Buildings, after it has passed through the Main Filter Banks in the SLCRS system before being discharged to atmosphere. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.
2-78
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply TurnmON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 ARERAS EXTRA9 XR053 2MSS-RQI101A RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 2.5E-3 2.5E3 0
N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 3.9E-2 uCi/cc >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.
2-79
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
AnaloglDigital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 ARERAS EXTRA10 XR054 2MSS-RQI101B RADIOACTIVITY OF RELEASED GASES A
uCi/cc N/A 2.5E-3 2.5E3 0
N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 3.9E-2 uCi/cc >BACKGROUND N/,A N/A.
DEPENDS ON FAILURE MODE N
N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.
2-80
BEAVER VALLEY POWER STATION ERDS DATA POINT LIBRARY Date:
Reactor Unit:
Data Feeder:
NRC ERDS Parameter:
Point ID:
Plant Spec Point Desc.:
Generic/Cond Desc.:
Analog/Digital:
Engr Units/Dig States:
Engr Units Conversion:
Minimum Instr Range:
Maximum Instr Range:
Zero Point
Reference:
Reference Point Notes:
PROC or SENS:
Number of Sensors:
How Processed:
Sensor Location:
Alarm/Trip Set Points:
NI Detector Power Supply Cut-Off Power Level:
NI Detector Power Supply Turn-ON Power Level:
Instrument Failure Mode:
Temperature Compensation for DP Transmitters:
Level Reference Leg:
Unique System Desc.:
9/16/2006 BV2 ARERAS EXTRA 11 XR055 2MSS-RQI101C RADIOACTIVITY OF RELEASED GASSES A
uCi/cc N/A 2.5E-3 2.5E3 0
N/A P
1 N/A SEE UNIQUE SYSTEM DESCRIPTION FIELD HIGH 3.9E-2 uCi/cc >BACKGROUND N/A N/A DEPENDS ON FAILURE MODE N
N/A 1 minute average data. Site dose assessment assigns correction factors to the uCi/cc to correct for source term differences depending on selected default source term and decay period. Only read if release ongoing. Density corrected to atmospheric pressure. Note: The instrument ranges provide nominal values based on a default monitor conversion factor. Therefore, the "Minimum Instr Range" and "Maximum Instr Range" may not reflect the actual instrument ranges due to minor dynamic changes to the monitor conversion factor. Ref: Calculation Package ERS-SFL-92-024; CR 04-05484.
2-81