IR 05000220/2003008

From kanterella
(Redirected from IR 05000410/2003008)
Jump to navigation Jump to search
IR 05000220-03-008, IR 05000410-03-008, on 05/05/2003 - 05/08/2003, Nine Mile Point Nuclear Station Unit 1 and Unit 2, Temporary Instruction 2515/148, Inspection of Nuclear Reactor Safeguards Interim Compensatory Measures
ML031680007
Person / Time
Site: Nine Mile Point  
(DPR-063, NPF-069)
Issue date: 06/16/2003
From: Lanning W
Division of Reactor Safety I
To: Conway J
Nine Mile Point
References
TI 2515/148, Rev 1 IR-03-008
Download: ML031680007 (3)


Text

June 16, 2003

SUBJECT:

NINE MILE POINT NUCLEAR STATION, LLC - INSPECTION OF NUCLEAR REACTOR SAFEGUARDS INTERIM COMPENSATORY MEASURES, TEMPORARY INSTRUCTION 2515/148, REVISION 1, INSPECTION REPORT NOS. 50-220/03-008, 50-410/03-008

Dear Mr. Conway:

On May 8, 2003, the U.S. Nuclear Regulatory Commission (USNRC) completed a special inspection at the Nine Mile Point Nuclear Station (NMPNS), in accordance with Temporary Instruction 2515/148, Revision 1, Inspection of Nuclear Reactor Safeguards Interim Compensatory Measures. The enclosed report documents the inspection findings which were discussed on May 8, 2003, with Mr. Bill Byrne, Security Director, and other members of your staff.

This inspection examined activities conducted under your license as they relate to safety and to compliance with the Commissions rules and regulations, and with the conditions of your license. The specific purpose of this inspection was to verify that NMPNS effectively implemented the interim compensatory measures (ICMs) imposed by the Order Modifying License issued February 25, 2002; and that the ICMs were successfully incorporated into your site physical protection strategy and security program. Additionally, the objective of the inspection was to ensure that relevant procedures were developed and implemented, and that interface agreements with offsite organizations were developed and coordinated, as required.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection, no findings of significance were identified. The inspection team verified and confirmed that NMPNS had effectively implemented the specifications of the Order Modifying License issued February 25, 2002.

Mr. John In accordance with 10 CFR 2.790 of the NRCs "Rules of Practice," a copy of this letter, without enclosure will be made available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

/RA/

Wayne D. Lanning, Director Division of Reactor Safety Docket Nos.

50-220, 50-410 License Nos. DPR-63, NPF-69 Enclosure:

NRC Inspection Report Nos. 50-220/03-08, 50-410/03-08 (CONTAINS (SGI))

w/Attachment: Supplemental Information cc w/o encl w/o SGI:

M. J. Wallace, President, Nine Mile Point Nuclear Station, LLC M. Wetterhahn, Esquire, Winston and Strawn J. M. Petro, Jr., Esquire, Counsel, Constellation Power Source, Inc.

P. D. Eddy, Electric Division, NYS Department of Public Service C. Donaldson, Esquire, Assistant Attorney General, New York Department of Law J. V. Vinquist, MATS, Inc.

P. Smith, Acting President, New York State Energy Research and Development Authority Supervisor, Town of Scriba C. Adrienne Rhodes, Chairman and Executive Director, State Consumer Protection Board T. Judson, Central NY Citizens Awareness Network

Mr. John