Responds to Violations Noted in Insp Rept 50-389/92-07. Corrective Actions:On 920421,Main Steam Safety Valve Testing Stopped & Gauge Calibr Data Sheets Reviewed & Containment Pressure Sensing Lines Will Be Labeled
ML17227A492
Person / Time
Site: Saint Lucie 
Issue date: 06/26/1992
From: GOLDBERG J H
FLORIDA POWER & LIGHT CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
L-92-172, NUDOCS 9207060170
Download: ML17227A492 (7)


Text

ACCELERATEDDISTMBUTIONDEMONSTPWTIONSYSTEMREGULATORYINFORMATIONDlSTRIBUTIONSYSTEM(RIDS)Jl~~~~~CESSIONNBR:9207060170DOC.DATE:92/06/26NOTARIZED:NOCIL:50-369St.LuciePlant,Unit2,FloridaPower&LightCo.AUTH.NAMEAUTHORAFFILIATIONGOLDBERG,J.H.FloridaPower&LightCo.RECIP.NAMERECIPIENTAFFILIATIONDocumentControlBranch(DocumentControlDesk)

SUBJECT: RespondstoviolationsnotedinInspRept50-389/92-07.Correctiveactions:on920421,mainsteamsafetyvalvetestingstopped&gaugecalibrdatasheetsreviewed&containmentpressuresensinglineswillbelabeled.DISTRIBUTIONCODE:IEOIDCOPIESRECEIVED:LTRQENCLjSIZE:TITLE:General(50Dkt)-InspRept/NoticeofViolationResponseNOTES:DOCKET05000389RECIPIENTIDCODE/NAMEPD2-2PDINTERNAL:ACRSAEOD/DEIIBDEDRONRR/DLPQ/LHFBPTNRR/DOEA/OEABNRR/DST/DIR8E2NUDOCS-ABSTRACTOGC/HDS3RGN2FILE01EXTERNAL:EG&G/BRYCE,J.H.NSICCOPIESLTTRENCL112211111111111111111111RECIPIENTIDCODE/NAMENORRISPJAEODAEOD/DSP/TPABNRRMORISSEAUPDNRR/DLPQ/LPEB10NRR/DREP/PEPB9HNRR/PMAS/ILRB12EGFILE02NRCPDRCOPIESLTTRENCL11111111111111111111NOTETOALL"RIDS"RECIPIENTS:PLEASEHELPUSTOREDUCEW~!CONTACTTHEDOCUMENTCONTROLDESK,ROOMPI-37(EXT.20079)TOELIMINATEYOURNAMEFROMDISTRIBUTIONLISTSFORDOCUMENTSYOUDON'TNEED!TOTALNUMBEROFCOPIESREQUIRED:LTTR23ENCL23 P.O.Box14000,JunoBeach,FL33408-0420FPLJUN263992L-92-17210CFR2.201U.S.NuclearRegulatoryCommissionAttn:DocumentControlDeskWashington,D.C.20555Re:St.LucieUnit2DocketNo.50-389ReplytoNoticeofViolationInsectionReort92-07FloridaPowerandLightCompany(FPL)hasreviewedthesubjectinspectionreportandpursuantto10CFR2.201theresponsetothe~~~~noticeofviolationisattached.Verytrulyyours,J.H.GoldbergPresident-NuclearDivisionJHG/JWH/kwAttachmentcc:StewartD.Ebneter,RegionalAdministrator,USNRCRegionIISeniorResidentInspector,USNRC,St.LuciePlantDAS/PSL8713-929207060170920626PDRADOCKOS0003896PDRanFPLGroupcompanygYpg~(l Re:St.LucieUnit2DocketNos.50-389ReplytoNoticeofViolationInsectionReort92-07VIOLATION(A):Unit2TechnicalSpecification(TS)6.8.1.crequiredthatwrittenproceduresshallbeestablished,implemented,andmaintainedcoveringsurveillanceandtestactivitiesofsafety-relatedequipment.TS4.7.1.1andassociatedtable4.7-0,SteamLineSafetyValves,requiredthatfourspecificsafetyvalvesperSGbeverifiedtobesetat1000psia+/-onepercentt10psi],andthattheotherfourbesetat1040psia+/-onepercent.LicenseeprocedureGMP-0705,Rev17,MainSteamSafetyValveMaintenanceandSetpressureTesting,implementedtheserequirements.GMP-0705section8.0,MaterialandEquipmentRequired,plainlyspecifiedthatalltestgagesshallhaveanaccuracyof0.5~offullscale.Contrarytotheabove,onApril21,1992,thelicenseefailedtoimplementGMP-0705section8.0,MaterialandEquipmentRequired,byusing200poundpersquareinchgageM-201whichhadalargeonepercentcalibrationlabelonitssideandwasalsoaccompaniedbyacalibrationrecordshowingthatitactuallyvariedoveraonepercentrange.Anothergageinusethathadnotbeenquestionedalsohadalargeonepercentcalibrationlabelbutthecalibrationrecordshowedthatiswasactuallysatisfactoryforthistest.VIOLATION(B):Unit2TechnicalSpecification(TS)3.3.2andincludedTable3.3-3requiredthatEngineeringSafetyFeaturesActuationSystem(ESFAS)instrumentationbeOPERABLEfortheContainmentSprayfunctioninoperationalModes1,2,or3;includingaminimumofthreeofthefourchannelsofContainmentPressure-High-High.ActionStatement17requiredthat,withthreeofthefourchannelsOPERABLE,theinoperablechannelmustbeplacedinthetrippedconditionwithin48hours.ActionStatement17furtherstatedthatoneadditionalchannelmaybebypassedforuptotwohoursforsurveillancetesting.Unit2TS3.3.2andincludedTable3.3-3alsorequiredthatESFASinstrumentationbeOPERABLEfortheSafetyInjection,ContainmentIsolation,andMainSteamLineIsolationfunctionsinoperationalModes1,2,or3;includingaminimumofthreeofthefourchannelsofContainmentPressure-High.ActionStatement13requiredthat,withthreeofthefourchannelsOPERABLE,poweroperationmaycontinueprovidedthattheinoperablechannelisplacedinthebypassedortrippedconditionwithinonehour.ActionStatement14requiredthat,withtwoofthefourchannelsinoperable,poweroperationmaycontinueprovidedthatoneoftheinoperablechannelshasbeenbypassedandtheotherinoperablechannelisplacedinthetrippedconditionwithinonehou St.LucieUnit2DocketNos.50-389ReplytoNotice-ofViolationInsectionReort92-07VIOLATION(B)(continued)Unit2TS3.3.1andincludedTable3.3-1requiredthat.reactorprotectivesystem(RPS)instrumentationbeOPERABLEinoperationalModes1or2,includingaminimumofthreeofthefourchannelsofContainmentPressure-High.ActionStatement2.arequiredthat,withthreeofthefourchannelsOPERABLE,poweroperationmaycontinueprovidedthattheinoperablechannelisplacedonthetrippedorbypassedconditionwithinonehour.ActionStatement2.brequiredthat,withtwoofthefourchannelsOPERABLE,poweroperationmaycontinueprovidedthatoneoftheinoperablechannelshasbeenbypassedandtheotherinoperablechannelisplacedinthetrippedconditionwithinonehour.Contrarytotheabove,ContainmentPressureChannelC(HighandHigh-High)wasinoperableatleastduringthepreviousoperatingcyclefromabout.December,1990toApril22,1992,becauseitsinstrumentsensinglineinsidecontainmentwascapped,andContainmentPressureChannelCwasnotplacedinthetrippedorbypassedconditionasrequired.Duringmostofthistime,St.LucieUnit2wasoperatedinMode1or2.Additionally,withContainmentPressureChannelCinoperable,anotherchannelofcontainmentpressurewasplacedinbypassonApril19,1992,foratotalofapproximately3hours,whiletheunitwasoperatedinMode1ol2~

St.LucieUnit2DocketNos.50-389ReplytoNoticeofViolationInsectionReort92-07RESPONSE(A)1~2~ThereasonfortheviolationwaspersonnelerroronthepartofMaintenanceSupervision.SupervisiondidnotverifytheproceduralrequirementsforTestGaugeCalibrationaccuracyweremet.Afactorcontributingtothispersonnelerrorwasthattherequirementsforgaugeaccuracywerenotspecifiedinallapplicablesectionsofthemaintenanceprocedure.CorrectiveStesTakenandResultsAchieved3~OnApril21,1992,MainSteamSafetyValvetestingwasstoppedandgaugecalibrationdatasheetswerereviewed.Gaugef201wasdeterminednottomeetthe.54accuracyrequirementandwasreplacedwithanewgaugemeetingthe.54accuracystandard.TheMainSteamSafetieswhichhadbeentestedwithGaugef201wereretestedusingthenewgaugeanddeterminednottorequireadjustment.Allpersonnelinvolvedweremadeawareoftheinfractionandtheneedforproceduralcompliance.CorrectiveStestoAvoidFurtherViolationsa)AmemowasissuedtoallProductionSupervisorsandForementostresstheimportanceofproceduralcompliance.4~b)DisciplinaryactionwasadministeredtotheMaintenanceSupervisioninvolvedinthisevent.c)MaintenanceprocedureGMP-0705willberevisedtospecifythegageaccuracyrequirementsinallapplicablesectionsoftheprocedureandincludegaugeaccuracyrequirementsaspartoftheQCholdpointtoverifyM&TEofpressuregauges.d)MechanicalMaintenancewillreviewallsafetyandreliefvalvetestprocedurestoensuretestgaugeranges,type,andaccuracyrequirementsareadequatelyspecified.FullcompliancewasachievedonApril21,1992,uponcompletionofcorrectiveactioninparagraph2.Maintenanceprocedurereviews/revisionswillbecompletedbyAugust21,199 Re:St.LucieUnit2DocketNos.50-389ReplytoNoticeofViolationInsectionReort92-07RESPONSE(B)~1.ThereasonfortheviolationwaspersonnelerrorwhichresultedintheinadvertentcappingofthehighpressuresensinglinetothecontainmentpressuretransmitterPT-07-2C.2~CorrectiveStesTakenandResultsAchieveda)ThecapattachedtothesensinglinewasremovedonMay7,1992restoringtheoperabilityoftheinstrumentchannel.b)Anexaminationofmaintenanceandoperatinghistorywasperformedtodeterminetheperiodofinoperabilityandtheworkauthorizedonthisinstrument.Documentedevidenceindicatesthatnorelatedworkwasauthorizedonthisinstrument.TheevidencealsoindicatesthattheinstrumentwaslastverifiedtobeoperableonApril13,1989,whenthesensinglineswereproventobeunobstructed.c)AnengineeringanalysisandaPRAwereperformedtoidentifythepotentialconsequencesofthisinstrumentchannelbeinginoperable.Theconclusionofthisanalysisestablishedthatneitheracontainmentbreachnoradditionalcoredamagewouldresultfromthissensinglinebeingcapped.d)ApressurizedairtestwasperformedonallotherUnit1andUnit2containmentpressuretransmittersensinglineswhichverifiedallsensinglineswereunobstructed.ThiswasperformedonMay7,1992.3~CorrectiveStestoAvoidFurtherViolationsa)ContainmentpressuresensinglinesonUnit1and2willbelabeledtopreventinadvertentcappingutilizingtheestablishedplantlabelingprocedures.Unit2willbecompletedpriortoMode4duringthe1992refuelingoutage.Unit1willbecompletedduringthe1993Springrefuelingoutage.b)PlantdrawingsonUnit2willberevisedasnecessarytoidentifyrequiredsensinglinecapconfigurationbyOctober14,1992.Unit1drawingswillberevisedbyAugust1,199 ~~Re:St.LucieUnit2DocketNos.50-389ReplytoNoticeofViolationInsectionReort92-07c)Anewcontainmentatmospherepenetrationinspectionprocedure(I&CProcedureNo.1400205)hasbeenwrittentoverifyselectedcontainmentinstrumentationpipingpenetrationswhichsensethecontainmentopenvolumeatmospherearefreeofobstructions.ThisinstrumentationincludesprocessinputsintotheContainmentHydrogenAnalyzer,ContainmentAtmosphereRadiationMonitoring,EngineeredSafetyFeaturesActuationSystem,ReactorProtectionSystem,andContainmentDifferentialPressureInstrumentation.Thisprocedurewillbeperformedpriortoareactorstartupfollowingeachrefuelingoutage.d)Mud-daubercaps(insectend-covers)havebeeninstalledonUnit2containmentpressuresensinglinestoprecludepersonnelfromcappingthem.Unit1installationwilloccurduringthe1993Springrefuelingoutage.4.FullcompliancewasachievedonMay7,1992,uponcompletionofcorrectiveactioninparagraph2.a).fCorrectiveAction3aforUnit2willbecompletedpriortoheatuptomode4duringthe1992refuelingoutage.CorrectiveAction3aforUnit1willbecompletedduringthe1993Springrefuelingoutage.CorrectiveAction3bforUnit2willbecompletedbyOctober14,1992.CorrectiveAction3bfor.Unit1willbecompletedbyAugust1I1993'orrectiveAction3dforUnit1willbecompletedduringthe1993Springrefuelingoutage.