ACCELERATED DISTMBUTION DEMONST$&TION SYSTEM REGULATORY INN'ORATION DISTRIBUTION SYSTEM (RIDS)

ACCESSION NBR:9011200038 DOC.DATE: 90/11/09 NOTARIZED: NO FACIL:50-387 Susquehanna Steam Electric Station, Unit 1, Pennsylva 50-388 Susquehanna Steam Electric Station, Unit 2, Pennsylva AUTH.NAME AUTHOR AFFILIATION OYNER,J.H.

Region 1 (Post 820201)

RECIP.NAME RECIPIENT AFFILIATION KEISERPH.W.

Pennsylvania Power

& Light Co.

SUBJECT:

Forwards Insp Repts 50-387/90-14 6 50-388/90-14 on 900731-0802.Violations:

DISTRIBUTION CODE:

IEISD COPIES RECEIVED:LTR g ENCL i SIZE:

TITLE: Fitness for Duty Program Inspection Report NOTES:LPDR

cy Transcripts.

LPDR 1 cy Transcripts.

DOCKET 05000387 05000388 f/W S

05000387 05000388 /

A RECIPIENT ID CODE/NAME PDl-2 LA THADANI,M COPIES LTTR ENCL

1

1 RECIPIENT ID CODE/NAME PD1-2 PD COPIES LTTR ENCL

1 D

D INTERNAL: NRR/DRIS/RSGB REG FILE

EXTERNAL: NRC PDR TES:

1

1

1

2 NSIC

1

@UBOCS~

TRACT

1 RGM.

FI-ErB ~

1 D

NOTE TO ALL"RIDS" RECIPIENTS:

PLEASE HELP US TO REDUCE WASTE! CONTACTTHE DOCUMENT CONTROL DESK, ROOM Pl-37 (EXT. 20079) TO ELIMINATEYOUR NAMEFROM DISTRIBUTION LISTS FOR DOCUMENTS YOU DON'T NEED!

A D

D TOTAL NUMBER OF COPIES REQUIRED:

LTTR

ENCL

I J

(N (

Docket Nos.

50-387 50-388 Pennsylvania Power

& Light Company ATTN:

Mr. Harold W. Keiser Senior Vice President Nuclear 2 North Ninth Street Al 1 entown, Penn syl vani a 18101 Gentlemen:

Subject:

Combined Inspection Nos. 50-387/90-14 and 50-388/90-14 This letter refers to the initial inspection of the Fitness-For-Duty Program for the Susquehanna Steam Electric Plant, Units 1 and 2.

The inspection was conducted on July 31 August',

1990, by Messrs.

R. Albert and A. Della Ratta of this office, and observed by Messrs.

L. Bush, Office of Nuclear Reactor Regulation, and E. King, Region I.

Areas examined during the inspection are described in the inspection report which is enclosed with this letter.

Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspectors.

Based on the results of this inspection, we found that the development and implementation of your FFD program are responsive to both the spirit and intent of the NRC's FFD rule.

In particular, you are commended for your proactive approach in handling personnel with infrequent site access.

We under stand that you reduced your infrequent-access roll from over 1,000 personnel to about

personnel, and that you are prepared to reduce that number further if that number presents random testing problems.

However, within the scope of this inspection, it appears that one of your activities was not conducted in full compliance with the requirements of 10 CFR 26 as set forth in the Notice of Violation enclosed herewith as Appendix A.

The violation has been categorized by severity level in accordance with the

"General Statement of Policy and Procedure for NRC Enforcement Actions,"

CFR Part 2, Appendix C (Enforcement Policy).

You are required to respond to this letter, and in preparing your response, you should follow the instructions in Appendix A.

In addition, three unresolved items were identified during the inspection.

In your response to this letter, we would appreciate receiving a

summary of the current status of the items identified as unresolved in'the enclosed inspection report.

9011200039 901109 PDR ADOCK 05000387

PNU OFFICIAL RECORD COPY CIR SUS 90-14 - 0001.0.0 11/07/90

Pennsylvania Power

& Light Co.

ItOV 00 1990 The responses requested by this letter are not subject to the clearance procedures of the office of management and budget as required by the paperwork reduction act of 1980, PL 96-511.

In accordance with 10 CFR 2.790(a),

a copy of this letter and the enclosure will be placed in the NRC Public Document Room.

Your cooperation with us is appreciated.

Sincerely, Original Sign.d By:

James H. Joyner James H. Joyner, Chief Facilities Radiological Safety and Safeguards Branch Division of Radiation Safety and Safeguards Enclosure:

NRC Region I Combined Inspection Report Numbers 50-387/90-14 and 50-388/90-14 cc w/encl:

A.

R. Sabol, Manager, Nuclear Quality Assurance J.

M. Kenny, Licensing Group Supervisor R.

G.

Bryam, Superintendent of Plant-SSES S.

B. Ungerer, Manager, Joint Generation Projects Department J.

D. Decker, Nuclear Services Manager, General Electric Co.

B. A. Snapp, Esquire, Assistant Corporate Counsel H.

D. Woodeshick, Special Office of the President J.

C. Tilton, III, Allegheny Electric Cooperative, Inc.

C. Sprunk, Director, Corporate Security Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

K. Abraham, PAO (2) All Inspection Reports NRC Resident Inspector Commonwealth of Pennsylvania OFFICIAL RECORD COPY CIR SUS 90-14 - 0002.0.0 08/20/90

Pennsylvania Power

& Light Co.

bcc w/encl NOV 0g gg0 Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o encl)

J. Joyner, DRSS P. Swetland, DRP R. Blough, DRP P.

Kaufman, DRP M. Thandani, NRR/PD 1-2 K. Abraham, PAO (20)

SALP Report and (2) All Inspection Reports J. Caldwell, EDO D. McGuire, Region II J.

Creed, Region III C. Cain, Region IV M. Schuster, Region V

B. Grimes, NRR/DRIS P.

McKee, NRR/RSGB L. Bush, NRR/RSGB G.

McPeek, NRR/RSGB Albert pi~!/O7I90 RI:D S

Kei

~j7/90 b

RI:DRSS oyner

/g/90 ll OFFICIAL RECORD COPY CIR SUS 90-14 0003.0.0 08/20/90