December 18, 2019

SUBJECT:

LASALLE COUNTY STATION, UNITS 1 AND 2 - MATERIAL CONTROL AND ACCOUNTING PROGRAM INSPECTION REPORT 05000373/2019412 AND 05000374/2019412

Dear Mr. Hanson:

On November 22, 2019, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at LaSalle County Station, Units 1 and 2. On December 4, 2019, the NRC inspectors discussed the results of this inspection with Mr. D. Mearhoff, Regulatory Assurance Manager, and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with 10 CFR 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely,

/RA/

Kenneth R. Riemer, Chief Branch 1 Division of Reactor Projects

Docket Nos. 05000373 and 05000374 License Nos. NPF-11 and NPF-18

Enclosure:

As stated

Inspection Report

Docket Numbers:

05000373 and 05000374

License Numbers:

NPF-11 and NPF-18

Report Numbers:

05000373/2019412 and 05000374/2019412

Enterprise Identifier: I-2019-412-0023

Licensee:

Exelon Generation Company, LLC

Facility:

LaSalle County Station, Units 1 and 2

Location:

Marseilles, IL

Inspection Dates:

November 11, 2019 to November 22, 2019

Inspectors:

J. Havertape, Resident Inspector

Approved By:

Kenneth R. Riemer, Chief

Branch 1

Division of Reactor Projects

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a material control and accounting program inspection at LaSalle County Station, Units 1 and 2, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Unless otherwise noted, baseline security inspections were conducted in accordance with the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter 2201, Security Inspection Program for Commercial Nuclear Power Reactors. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards. Publicly available IPs are located at:

http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html.

SAFEGUARDS

71130.11 - Material Control and Accounting (MC&A)

An NRC inspector evaluated the Material Control and Accountability program at the LaSalle County Generating Station through completion of the following IP elements:

Material Control and Accounting (MC&A) (15 Samples)

(1) Special Nuclear Material Records (3 Samples)
(2) Material Control and Accounting Programs and Procedures (2 Samples)
(3) Physical Inventory of Special Nuclear Material (8 Samples)
(4) Special Nuclear Material Reports (1 Sample)
(5) Problem Identification and Resolution (1 Sample)

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

  • On December 4, 2019, the inspectors presented the material control and accounting program inspection results to Mr. D. Mearhoff, Regulatory Assurance Manager, and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

71130.11

Corrective Action

Documents

AR 4054981

RM - Results of L2C16 Failed Fuel Bundle Inspection

09/21/2017

AR 4092307

2019 Material Control and Accountability SNM Inspection

Self-Assessment

10/24/2018

AR 4138175

2018 Supply Fleet Warehouse Self-Assessment

05/16/2018

AR 4187325

MC&A SA Deficiency: SNM Documentation Issues

10/24/2018

AR 4231717

SNM Program Enhancements

03/21/2019

AR 4259412

NOS ID: Incorrect Date for Beginning the 2018 SNM

Inventory

06/25/2019

Miscellaneous

NF-AB-309

Pages 333-335 of 2018, L2R17 Fuel Receipt #4

01/07/2019

NF-AB-309

Pages 354-356 of 2018, L2R17 Fuel Receipt #11

01/08/2019

NF-AB-309

Pages 395-396 of 2018, LPRM Receipt for L2R17

01/16/2019

NF-AB-309

Pages 357-394 of 2018, Pre L2R17 B5b #2

2/18/2019

NF-AB-309

Pages 24-26 of 2019, L2R17 Fuel Inspections

03/03/2019

NF-AB-309

Pages79-151 of 2019, L2R17 Shuffle 2

03/18/2019

NF-AB-309

Pages 232-236 of 2019, Load MPC-585

06/14/2019

NF-AB-309

Pages 242-246 of 2019 Load MPC-598

07/18/2019

NF-AB-309

Pages 252-256 of 2019 Load MPC-600

08/14/2019

NF-AB-309

Pages 262-266 of 2019 Load MPC-602

09/16/2019

Unit 1 SFP Map

11/01/2019

Unit 2 SFT Map

11/01/2019

Procedures

NF-AA-30

Special Nuclear Material Control Process Description

005

NF-AA-300

Special Nuclear Material Control and Accountability

2

NF-AA-310

Special Nuclear Material and Core Component Movement

23

NF-AA-330

Special Nuclear Material Physical Inventories

015

Shipping Records NF173428

Transmittal of DOE NRC Form 741 for LaSalle Unit 1 Cycle

NF Transaction 133 YLJZSB133,

11/27/2017

NF173472

Transmittal of DOE NRC Form 741 for LaSalle Unit 2 Cycle

NF Transaction 138 YLJZSB138

2/18/2017

NF184333

Transmittal of DOE NRC Form 741 for LaSalle Unit 2 Receipt

of Fuel Assemblies for Cycle 18 New Fuel Transaction

YLJZSS120

11/20/2018

Inspection

Procedure

Type

Designation

Description or Title

Revision or

Date

NF184364

Transmittal of DOE NRC Form 741 for LaSalle Unit 2 Receipt

of Fuel Assemblies Cycle 18 New Fuel Transaction

YLJZSS126

2/10/2018

NF184368

Transmittal of DOE NRC Form 741 for LaSalle Unit 2 Receipt

of Fuel Assemblies Cycle 18 New Fuel Transaction

YLJZSS130

2/20/2018

Work Orders

WO 1609201-01

2016 Serial Number Inventory of Nuclear Fuel

06/30/2016

WO 1938239-01

2017 Annual SNM Inventory

06/30/2017

WO 4645981-01

Inspection of Failed Fuel Assembly

09/21/2017

WO 4661503-01

2018 Annual SNM Inventory

06/28/2018

WO 4802413-01

2019 Annual SNM Inventory

06/27/2019