p# R$!og UNITED STATES 4'

NUCLEAR REGULATORY COMMISSION y

REGION il

!

,

g j

101 MARIETTA STREET,N.W.

f

ATLANTA, GEORGI A 30323 i

%, *. * *,,o

Report.Nos.: 50-348/85-38 and 50-364/85-38

'

' ll Licensee': Alabama Power Company

'

.000 Horth 13th Street Birmingham,.AL 35291 Docket Nos.,: '50-348 and 50-364 License Nos.:

NPF-2 and NPF-8

.pacilityName: 'Farley 1 and 2 Inspection Conducted: September 11 - October 10, 1985 Inspection'at Farley site near Doth'an, Alabama

~

//!/ ff

, Inspectors:

N f f 4 i.c f 4'

Dat6 Signed W. H.~Bradford

[

"

muAV22

"Nes B. RT Bonser

~ ~ "/// /

Date ' Signed

, Approved by:

d,

//[//

F. S. Cantrell-, Sectio %

Dats Signed Division'of Reactor Project-SUMMARY Scope: This routine, unannounced inspection entailed-150 inspector-hours on site in the areas of monthly surveillance observation,' monthly maintenance observa-

.

tion, operational safety verification, and engineered safety. system inspection.

Results: Within.the areas inspected, no violations or deviations were identi-fled.

x

.,

_

,x

'!./

>;~

8511140107 851101 PDR ADOCK 05000348

-

.G

_

PDR-i n

.

^

.

.

.

.

-.s

.

.

REPORT DETAILS 1.

' Licensee Employees Contacted:

J. D. Woodard, Plant Manager 0. N.' Morey, Assistant Plant Manager W. D. Shipman, Assistant Plant Manager R. D. Hill, Operations Superintendent

.C. D. Nesbitt, Technical Superintendent R. G. Berryhill, Systems Performance and Planning Superintendent L. A. Ward, Maintenance Superintendent L. W. Enfinger, Administrative ~ Superintendent

'J. E. Odom,. Operations Sector Supervisor B. W. Vanlandingham, Operations Sector' Supervisor T. H. Esteve, Planning Supervisor J. B. Hudspeth, Document Control Supervisor

,

L. K. Jones, Matarial Supervisor

'. H. Marlow, Technical Supervisor

-

L. M. Stinson, Plant Modification Supervisor W. G. Ware, Supervisor, Safety Audit Engineering Review Other licensee employees contacted included technicians, operations personnel, maintenance and I&C personnel, security force members, and office personnel.

2.

Exit Interview The inspection scope and findings

. ere summarized during management w

interviews throughout the report period and on September 15, 1985, with the plant manager and selected members of his staff. The inspection findings were discussed -in detail. The licensee did not identify-as proprietary any material reviewed by the inspector during this inspection.

3.

Licensee Action on Previous Enforcement Matters-(92702)

~

Not inspected.

4.

. Monthly Surveillance Observation (61726)'

The 1 inspectors observed and reviewed Technical Specification required surveillance testing and verified that testing was performed in accordance with-adequate procedures;- that test instrumentation was calibrated; that limiting conditions were met; that test results met; acceptance criteria and were reviewed by personnel other than the individual directing.the. test; that any deficiencies identified 'during -the testing were properly reviewed

.and. resolved, by appropriate management personnel; and '.that personnel.

conducting the tests were qualified.

.The' inspectors' witnessed / reviewed portions ofL he following test activities:

t

-

-

'A

-

-

g

-

.

.

a FNP-2-STP-7.0 Quadrant Power Tilt Ratio Calculation.

-

-FNP-1-STP-33.0 B - Solid State Protection _ System Operability Test.

FNP-1-STP-33.1 B - Safeguards Test Gabinet Train Functional Test.

FNP-1-STP-14.0'

Containment Integrity Verification Test.

-

FNP-2-STP-22

- Auxiliary Feedwater Normal Flow Path Verification.

FNP-2-STP-22.18 Auxiliary Feedwater Automatic Valve Position

-

Verification.

FNP-2-STP-21.3 Turbine Driven Auxiliary Steam Supply Valve

-

Inservice Test.

FNP-1/2-STP-70.0 - Containment Sump Surveillance.

Containment Cooling System Train A (B) Operability -

FNP-2-STP-17.0

-

Test.

-FNP-1/2-STP-1 Operations Daily and Shift Surveillance Requirement.

-

FNP-2-STP-80.1

- Diesel Generator 2B Operability Test.

FNP-1-STP-11.10 RHR Pump 1B Monthly Operability Check.

-

FNP-0-STP-154.0 - Diesel Generator Air Dryer Operation Verification.

FNP-1-STP-134

- Fire Doors and Dampers Functional Inspection.

Within the areas inspected _ no violations or deviations were identified.

5.

Monthly Maintenance Observation (62703)

Station maintenance activities of safety-related systems and components were observed / reviewed to ascertain that they were conducted in accordance with approved procedures, regulatory guides, industry codes 'and standards, and were in conformance with Technical Specifications.

'The following items were considered during the review: limiting conditions for operations were met while components - or systems were removed from service; approvals were obtained prior to initiating the work; activities were accomplished using approved procedures.and were inspected as appli-cable; functional testing and/or calibrations ~.were performed prior to-returning components or systems to service; quality control' records were-maintained; activities were accomplished by qualified personnel; parts _ and

materials were properly certified; radiological controls were implemented; and fire prevention controls were implemented.

Work requests were reviewed t'o determine the statuI of outstanding jobs to assure that priority was assigned to safety-related equipment-maintenance which may affect system performance. The following maintenance activities-were observed / reviewed:

.IB charging pump reduction gear-oil cooler.

-

Unit 2 letdown-relief valve.

-

'2B post LOCA hydrogen recombiner.

--

PCN SE 81-909 diesel generator controls modification to prevent

-

motoring diesel generators 1-2A, 18, IC,'and'2C.

1-2A diesel generator.

-

2A inverter diagnostic test gear. checkout and installatien.

-

~2B diesel generator starting air compressor.

-

.

.

'

s Within the areas inspected no violations or deviations were identified.

Operational Safety Verification (71707)

a.

The inspectors observed control room operations, reviewed applicable logs and conducted discussions with control room operators during the report period.

The inspectors verified the operability of selected emergency systems, reviewed tagout records, and verified prcper return to service of affected components. Tours of "e auxiliary, diesel, and turbine ouildings were conducted _to observe piant equipment conditions, including fluid leaks and excessive vibrations.

b.

The ' inspectors verified compliance with _ selected Limited Condition for Operations. (LCO) and _.results of selected surveillance tests.

.The

' verifications-were, accomplished by direct observation of monitoring

-

instrumentation, valve positions, _ switch positions and review' of completed logs, records, and chemistry-results.

The licensee's compliance with LCO action statements were reviewed as they happened.

The'following systems and components were observed / verified opera-

.

tional:

,

-

Station electrical boards in the control room and various elec-trical boards throughout the plant for proper electrical align-ment.

Certain accessible hydraulic snubbers.

-

Accessible portions of service water and component cooling water-

-

systems.

.

Units 1 and 2_ suction. and. discharging piping and valves on

-

auxiliary feedwater system.

,

Diesel generators and support systems.

-

Certain accessible portions ~ of.CVCS piping and valves to and from

-

.the charging /high_ head safety injection pumps.

-

.

Certain portions of RHR'and containment' spray systems.

-

Portions of various. other systems -(safety-related and. nonsafety -

-

related).

c.

The inspectors ' routinely attended meetings 'with 'certain -licensee

~

~

management and observed-various sh'.ft turnovers 'between shift super-visors,- shift ' foremen, and licensed operators.

These meetings and -

' discussions provided a. daily status of plant operating, maintenance,-

i-and. testing-' activities in -progress-as well as discussions of

,

significant problems.

i

.(

_

'

.

_

l

'

d.

The inspector verified.by observation and interviews with security l

force members that measures taken to assure the physical protection of

'

the facility met current requirements.

Areas inspected included the organization of the security force; the establishment and maintenance of gates, doors, and isolation zones; that access control and badging were proper; and procedures were followed.

e.

The Resident inspectors observed plant security guard firearms requalification at the on-site firing range on 10-1-85. Security guard requalification consisted of firing a 38 caliber revolver and 12 guage shotgun at silhouette targets for score and other familiarization exercises such as firing at night. and running 50 yards drawing and firing.

Security guard supervision was also observed requalifying with the appropriate weapons.

The requalification course was run safely and competently by' Alabama Power Company instructors.

f.

During an inspection of Unit I auxiliary feedwater system the inspec-tor found a damaged flexible conduit on the turbine driven auxiliary feedwater pump trip throttle valve MOV-3406. The conduit connected limit switches on one side of the valve to other controls on.the opposite side. The conduit formed a loop and was resting on the hot bonnet of the valve.

The outer covering of the conduit had deterio-rated away to expose the metal' flex of the conduit. The metal flex was also deteriorating. The inspector informed the Unit 1-Shift Supervisor who immediately initiated corrective action to get the conduit off the hot valve bonnet.

The flexible conduit has been replaced with new conduit and reroJted to not contact the hot portion of the valve.

Unit 2 does not have this problem.

g.

On September 24, 1985 Unit I annunciator on. "C" reactor coolant pump indicated a low oil level alarm.

The licensee isolated the alarm to the lower oil reservoir.

Unit.. load was decreased to 37% power and a

~

'

containment entry was made to verify the level-'was low. Oil was added

,

to the reservoir to return' it to normal level. The location of the oil leak could not be determined although there was an oilL film present.

The' unit was returned to full power operation.

.

Within the areas inspected no violations.or deviations were identified.

7.-

Engineered Safety Systems Inspection (71710)

- The inspectors performed various _ system ~-inspections during.the inspection period.

These. inspections: were performed by the sinspectors observing ~ four system -operators over a.two day period in their ' assigned. work area per-forming their operating duties in the radiation controlled areas of the Unit-1 and. Unit ;2 auxiliary buildings.

Overall plant conditions were assessed with - particular. attention to equipment condition, radiological control s,-

security, safety, adherence to-technical specification requirements, systems

,

.

,

--

e y

r-p a-

-

.

+

-,

..... -

1-valve alignment, and locked valve verification.

Major components were

-

checked for leakage and any general conditions that would degrade perform-

'ance or, prevent fulfillment of functional requirements.

The inspectors-verified that approved procedures and up-to-date drawings were used.

. Surveillance testing, valve line-ups and maintenance tagging operations were observed to be in accordance :with procedures - and administrative controls.

>

Portions of the following systems were observed for proper operation, valve alignment and valve verefication:

Auxiliary feedwater systems.

-

Chemical volume ~ control systems.

>

--

Service water systems.

-

-

. Boric acid transfer system.

-

Containment spray system, including chemical additive system.~

F

. Residual heat removal system.

-

Within the - areas ~ inspected no violations or ' deviations were identified.

4'

s i

+

,..,j-

.

r

-

p

,

,,

-

.

~

,

,-.-#