IR 05000329/1973003

From kanterella
Jump to navigation Jump to search
Insp Repts 50-329/73-03 & 50-330/73-03 on 730524-25.No Noncompliance Noted.Major Areas Inspected:License Audit Checklist,Shop Tour of Mfg Plant,Welding Area,Matl Storage, Internal Hardware & Steam Generator Matls
ML19344A232
Person / Time
Site: Midland
Issue date: 06/21/1973
From: Hayes D, Vandel T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML19344A229 List:
References
50-329-73-03, 50-329-73-3, 50-330-73-03, 50-330-73-3, NUDOCS 8008060596
Download: ML19344A232 (10)


Text

1 G

'

D *

D D ^T

.

p

,.

A

"

we

-

- -

-

.

!

,em () t.. /,...

l.j

}

UNITED STATES e

l ATOMIC ENERGY COMMISSION I.

,

\\

DIRECTORATE OF REGULATORY OPERATIONS

'

.

REGION lil

'8 8 @

799 ROOSEVELT ROAD m

GL. s4 ELLYN. ILLINOIS Sol 37 (312) 858-2800 d

June 21, 1973

,

i.

!

,

. Consumers Power Company N,ctet No. 50-229

'

ATTN:.'Mr. Stephen H. Howell Docket No. 50-330

.Vice President-

212 West Michigan Avenue

~ Jackson, Michigan 49201'

I

-

i j

Gentlemen:

i This refers to the inspection conducted by Mr. T. E. Vandel of this

.

office on May 24 - 25, 1973, at the Babcock and Wilcox Company j

located in Barberton, Ohio, relative to construction activities.at the Midland site authorized by AEC Construction Permits No. CPPR-81 i

'

and No. CPPR-82 and to the discussion of.our findings at the

!

conclusion of the inspection with Mr. A. J. Eirkle of your staff.

!

j The area examined during the inspection is identified in the enclosed i

inspection report. Within this area, the inspection consisted _of an i

examination of the procedures and techniques used during the audit, l'

observations by the inspector, and an interview with Mr. Birkle at

!

the conclusion,2f the inspection.

i l

No violations of AEC requirements were identified within the area l-examined during this inspection.

. By way of this letter, we.wish to establish our understanding with regard to certain steps you plan to take, as follows:

l.

Conduct s' follow-up audit to assure yourselves that documentation

'

is obtained for certain internals material that establishes that proper grain size was determined and that the material was properly

,

heat treated.

j 2; Determine that a nont mformance relative to lack of cladding

.

bond is controlled, properly dispositioned, and the final

+

-correction documented.'

-

f.

3.

Perform further evaluation relative to the compliance of electro-slag welding;to the recommended requireraants of Safety Guide 16.

p 31_(Regulatory Guide No. 1.34).

i- (

~

Wo.will a-ine your actions relative to these matters during our next

routine inspecticm.

,

i 1 0 0 8 0'6 0

.

.. _.

-.-____ - __

- ___ __ - __. __-__-

.

<

.

om o'

D

-

-.

,

< -

oo w

.

2 2-June 21, 1973 Consumers Power Company

-

,

,

A copy of our report of this inspection is enclosed and, in accordance with Section 2.790 of the AEC's " Rules of Practica", Part 2, Title 10,

$

Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the AEC's Public Document Room.

'

If.the inspection report contains information which you or your con-t tractors believe to be proprietary, it is necessary that you submit a written application to this office, within 20 days of the date of this letter, requesting.that such information be withheld from public dis-

.

closure. If such an application is submitted, it must identify the basis for which information is. claimed to be proprietary and should be prepared so that proprietary information identified is contained in a separate

.part of the document, since the application, excluding this separate part, will also be placed in the Public Document Room.

If we do not receive an application to withhold information, or are not otherwise i-contacted within the specified time period, the enclosed report will i

be placed in the Public Document Room with a copy of this letter.

i Unless you wish to make application to withhold information, no reply to this letter is necessary; however, should you have questions

,

concerning this inspection, we will be glad to discuss them with you.

,

i

Sincerely yours,

,

Boyce H. Grier Regional Director i

i

Enclosure:

RO Inspection Rpt No.

050-329/73-03 and No. 050-330/73-03

,

bec: R0 Chief, FS&EB RO:HQ-(4)

.

. Licensing (4)

'

nu % e, e1 m ac Regions I & 11 i

PDR Local PDR NSIC'

DTIE OGC, Beth, P-506A l

k (

.,

.

-.

,,#.

.,,, -

v,--

y

- -..

,,,, -,,,.

-

-s,,,

,,,,,

. -

-

8...

.

,

- '

~

"c

'~*

- ' -.-

' ~

^

=2:.:

.

LJ

,

,

_

.

-

-

,

.

.

.

,7

,

-...,-.

..g

,,,.

.

' '

r"

+

'

N..S. ATOMIC ENERGY-- COMMISSION -

,

i

"

l DIRECTORATE OF REGULATORY ~ OPERATIONS

'

,

REGION III

Report.of Construction Inspection

,

,

,

i RO-Inspection:ReportlNo. 050-329/73-03-i'

R0; Inspection =Rsport No'.;050-330/73-03 c

Licensee:

Consumers-Power Company

- 212 West Michigan Avenue Jackson, Michigan 49201

.

.

- Midland Units l'and-No. 2 License No. CPPR-81

'

'-Midland, Michigan and No. CPPR-82

.

Category: A

-

. Type of Licensee:

PWR -(B&W) - 818 Mwe

!.

Type ~of: Inspection:

, Licensee Vendor Audit Surveillance Inspection Babcock & Wilcox Company, Barberton,_ Ohio

' Dates of Inspection:

May 24 - 25, 1973

-

~

Date of Previous' Inspection: -April 17, 1973

5 nag ent Meeting).

efer#

,

.

.

Principal Inspector:

T.'E. Vandel-

-)/- 7f ~

(Date) ^

.

A

REGION lli

  1. stgg e 799 ROOSEVELT ROAD t

g

,

GLEN ELLYN. ILLINO:s 60137 (312) ass-teso -

A.

RO Inspection Report No.

050-329/73-04'and No. 050-330/73-04

'

Transmittal Date

June'29, 1973

"

Distribution:

Distribution:

RO Chief, FS&EB RO Chief, FS&EB RO:HQ (5)

.

RO:HQ '(4)

DJLCentral Files L:D/D for Fuel & Materials Regulatory Standards (3)

DR Central Files Licensing (13)

B.

RO Inquiry Report No.

N Transmittal Date

Distribution:

Distribution-RO Chie f, FS&EB.

RO Chief, FS&EB-l RO:HQ (5)'

RO:HQ i

DR Central Files DR Central Files Regulatory Standards (3)

Licensing (13)

,

C.

Incident Notification From:

(Licensee & Docket No. (or License No.)

i i

Transmittal Date

Distribution:

Distribution:

R0 Chief, FS&EB RO Chie f, FS&EB

RO
HQ (4)

RO:HQ (4)

, Licensing (4)

L:D/D for Fuel & Materials DR Central Files DR Central Files

.

'

~( /

_.