Forwards DOE Radiological & Environ Science Lab Analyses of Sr-89,Sr-90,gamma Spectrometry,Gross Alpha,Gross Beta & Tritium from Insp Rept 50-320/83-18,per ASLB Request
ML20206K024
Person / Time
Site: Crane 
Issue date: 11/14/1988
From: Lewis S
NRC OFFICE OF THE GENERAL COUNSEL (OGC)
To: Bloch P, Bright G, Paris O
Atomic Safety and Licensing Board Panel
References
CON-#488-7521 87-554-OLA, OLA, NUDOCS 8811290230
Download: ML20206K024 (5)


Text

,

,s u p l

l

%

V86tTE38TATEs

[,

n NUCLEAR REOULATCRY COMMISSION

,

j

!

WASMINGTON D. C. 20646 l

\\......

NOV 141918 T.7

,

W WI 18 P3:11 i

v:0

,.

,

[

Peter B. Bloch. Esq., Chairman Dr. Oscar H. Paris Ch y' "-

.a Administrative Judge Administrative Judge

"

'

l Atome Safety and Licensing Atomic Safety and Licensing l

Board Panel Board Panel r

'

l U.S. Nuclear Regulatory Comission U.S. Nuclear Regulatory Commission l

Washingtor. D.C.

20555 Washington D.C.

20555 Glenn 0. Bright Ahtnistrative Judge

-

Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission f

Washington. D.C.

20555 r

!

In the Matter of

!

GENERAL PUBLIC UTILITIES NUCLEAR I

l CORPORATION ET AL.

(Three Mile Island NucleaT Tfation. Unit 2)

!

Docket No. 50 320 OL A.

ASLBP No.87-554 0LA l

Dear A kinistrative JuJ;es:

i Staff Exhibit 7. for identification, states that a split Itould radwaste sample l

taken durinq Inspection 83-18 was sent to the NRC's reference laboratory. DOE l

Radiologica'

and Environmental Science Laboratory (RESL). for the following analyses: Sr-89. Sr 90. Gama si,ectrometry, gross alpha, gross beta, and tritium. The Licensing Board requested that the $taff provide documentation I

of the results of the RESL analyses of this sample. Attached are the results

!

of the RE5L snalyses and NRC Region l's comparison of the RESL results with L

the Licensee's results.

l To assist in interpretation of these tables, the Staff provides the following explanation of tems and concepts used. The radionuclides analyzed and

!

reported on page 1 e l hted in the first column.

The results reported or

[

page 2 are fror wim spectrometry analysis. RE5L has set forth in a footnote

'

at the bottoes w mr page an explanation of the criteria used to determine i

,

(

$$MNb

4 Y

e

.

,

,

-2-whether the results for each of the analyses are considered to be "detection" of the radionuclide. Applying those criteria, the analysis results for the following radionuclides exceed the stated criteria for detection: Gross Beta.

H-3, Sr-90, Co-60, Cs-134, Cs-137, and Sb-125. On page 3 "R" stands for

"Resolution," "A" for "Agreement" and "D" for "Disagreement." Under the

"Criteria for Comparing Analytical Results" now used by the Staff, ratios falling outside the "Agreement" bounds listed in Attachment 1 to Table 1 of Staff Exhibit 7 are deemed to be "Disagreements."

Sincerely, s(

.

Stephen H. Lewis Senior Supervisory Trial Attorney Enc 1: As stated, cc w/ enc 1:

Service list.

.

,, _,, _ -

~.--.

-.,_

_-

. - _ - -. _ - _ - -,. - - -. -. -

-

--..

.

-

-

-

Page 1

.

.

<

UNITM SYSTES DEPARTPENT CF ECERET

_I3AMO CPERATIOh5 OFFICE

,

RADICLOGICAL ANS KNVIR0mRENTAL SCIENCES LAEONATORY

.

. _ _ _.

.

_

_.

SAa9tE AECCas Sas&T-- -

-

-

SEAI AL -he.

--M21i A- - "

BSC OSLT

-

N0h NRC eeeeeeeeeeea**ese

-

.... 2 e......

50.

  • URGENT
  • CNSITE

l tevrta05 s

FATE WEEDED

~'RCUTINE X ~NCnROUTINE'

__

C'/ FSIT E X _._*_ Q n

      • o***********

,

l (~DATE_11/94/83 _

_ _. _ _3AP?LE SEWT_.. _

_

--

-- - - - - -

'

_.

11/23/E3 ANALYIED BY: RSRsRK8sTT,

l

' -SAWit NOUS 1530 PST SAPPLE RECEIVEp T1/28/83

} p AaIZATIch kRC1 7.53LYSI3 CGPPLETED 03/12/84 CRIGIKAL SIGHED SY: L.Z. BOCRAR 9 b i@SSSERT5:

,

3 f 'TWI WAIT 2, 101 MCL (PAPER 7ULF) ADDEt, CCLLECTED EV J. JAhG

'

g 2001st REss:LTs SUESTIchABLEJ NC EISULFITE. J.PCFE

",

+

.

  • ~ * * * * "

'237.

CUAETITT GATE CGUMT G' CSS EKGD RESULTS +/- 15;T*

LNITS f.

FOR USED USES COUhTED TIME CGtNTS CCUNTS

' Sa055 A 5 PL 01/24/64 1000

8 (

5 +/-

2; 2 1E -9 UCI/PL

  • Y EROSS EE7A BW

$ PL G'/23/84

21362

( 4.4 +/- C.2IC.2 )E -4 UCI/PL N-3 LS 10 ML 63fC6/C4

900CCD 36C C d.14 +/- 0.C2:0.02 3E -2 UCI/ML wx M. 5R-89 20C PL 01/C6/84

c7044e

(-C.1 +/- 1.GI1.0 ) E -5 UCI/PL

.

3R-90 20C ML 01/12/$4 2C 596331

( 2.25 +/- 0.09IO.09 3E -4 UCI/PL

-

m..

N

-

N is m

  • ESTI*ATEC rah 00R UNCERTAINTY DEPCRTED IS CNE STAh ARD deb!ATICh, IS.

SPALL hEGATIVE AhD OTHEN

  • g RESU:.TS LESS THAh OR ECUAL TC 25 ARE INTERPRETEC BY RESL AS INCLUDINC "ZERO" OR AS NCT DETECTEO.

q FOR EESULTS GREATER THAN 25 EUT LESS THAk OR E;UAL TC 35, DETECTIch IS CUESTIChASLE.

RESULYS O

GREATER TkAk 35 IhDICATE DETECTICh.

T IS THE ESTIPATED TCTAL UNCERTAINTY.

_ _ _ _ _ _ _ _ - _

_.

- _ _ _ _

-

_ ____ - __

____ _

_ _ _ _ _.

__ _ _. _

_

-

,,

-

Paga 2

.

fo:

g--

LEITED STATES DEPARTFECT OF ENERCY

r 100C3 CPECSTIchs CFFICE RADICLCGICAL AND ENVIROMPENTAL SCIENCES LARORATORY

'

SAMPLE RECORt $NEET SERIAL 60.

132114 V ^-

-

-

-.--

. - _.. _ _

{-

BRC C&LY N06 N RC eeeeeeeeeeeeeeeeeee eeeeeeeeeeeemse

-

W 380 30.

  • URGEMT
  • CNSITE

E -45VIR0h e

RATE DEEBES

  • CFFSITE R *
  • eeseeeeeeeeeemee

. _.

EcuTIME 1 NotROUTINE

,

...

. -...

.

.

A E 5 ATF 11/08/83~

1ARPLE-SENT ---11/ 23 / 23-


A NALVIED BY a - J. -S.-NORTCN-

. _ _ - -

.

% SASPLE NDet 1530 PST SAPfic AECEIhED 11/2E/83 i GSGANIIATICS

%RC1 ANALTSIS COPFLETED C3/12/84 ORIGINAL SIGHED BY: L.Z. 20CNAR

COWSENTS:

THE UNIT 2, 101 NCL (PAPER PULP) ADDED, COLLECTED ET J. JAhG 10 SINE REstLTS QUESTI0kARLE; NC RISULFITE. D. POPE

.

COLLECTION RATE:

11/08/83 ANALT315 07TE:

01/2C/84 DECAY TIPE 73. NAYS *

7 ISL'MT TIME 62 min-DEYECTSR HUMMED

SdFFLE SIZE 4.COE+02 RL

?

TOTAL GRCSS BEGD MInCR MET ISCTSPE RESULTS +/- 15;T**

C0thT COURT C0tMT COUNT COUNT C/F C/n C/5 C/F UCI/PL fhf

  • 78 2.87 2.57 CC (C ( 1.73 +/- 0.14;0.14 )E -6 228 3.48 3.66 CS 1!4 ( 1.69 + /- C.16 ; 0.16 JE -6

.

i

.4&3 78.76 78.76 CSD137 C 2.85 +/- C.C9;C.C9 )E -5

-

"

C.55 0.06 0.49 PA

!*

( I.3 +/- C.S;C.! )E -7 E

1.24 1.2c RUD1C6 ( 4.2 +/- 1.6;1.6 ) E -6

~

29983 483.63 423.60 SE 125 C 3.4c +/- C.1C;0.10 )E -4 n0

  • SECAY CCENECTION CF hATUSAL CHAIk OAUGHTE9S PER LCPGEST LIVED PARENT o* ESTIPATEC RAhDOM UNCERTAfkTY REPCRTtD IS ChE STJhDARC DE%IATIch, 15.

SMALL hEGATIVE AND OTHER g

s SESULTS LESS THAh OR ECUAL TC 25 ARE INTERPRETE) EY RESL AS INCLL3ING "ZEE 0" OR AS NCT DETECTED.

R FOR RESULTS GREATER TNAN 25 EUT LESS THA.* OR 2^U8L TC 35, CETECTIOh ~5 QUESTIONABLE.

RESULTS O

GREATER TNAh 35 lhDIC ATE OETECTICN.

T iS THE 131IPATED TOTAL Uf. CERTAINTY.

_-

.

.

.

P.g3 8 M* M C

.

,

,

,

P. 4,, !!) Cl.1*.AK 1:)*(:11LA70RY CMIM1 SS1 ON

,

t erTJ t t. 01 114.)'l.( s 10;; ASin 1:$FNCE!11 lfi

'

1:F:G101; )

i

-

.

-

(

<.

l-A_t*61 Y11 cal. 1.W(iR ATO,RY,1. l:!st pSill.T.';

i

_

r 1., e s il-I s* t.1 s'ill b1 "' 1

!I8 I C hI,s...:.itsigg

.

-..

.,,.......... s.........., x ge s <_.

..

-

i

.

.

.....

._

(

'4 3.e

. i f

't.< f.1

V. t i l l t Hl. l un (

S ~~)

E.i j8 *.I'i.3 i i.Y_.

$..)

..

1 n r.js t-rim

!,

,,,q,

,

.

...

.

..

....,}.n p),a nt, h T

, y g.c n f !....;il e : t:i.. ori.. <l (

)

E1 Ilureit (

)

A, i ncil (

4-l' a i', l a.i.t..< is t ill (

)

,

.

l I.

_ _...

.

of/4f[

h R a t.i t'

.,..,,,,3

. t.
ta r.o l t r. i ii units i,i,

,

--

.

'

..c... i i. : i n.o

! i... ) y.. l i.

14HC Ks.Ielcaire Lab.

1.ab beinl: Tentcp R

Lie /Ref Art e a c. n

"

i

]

~~~

g3-/73/7

% #pQ (L*J-2.6-7.,__... _<.. 3..'1.f'

_.,,3._

--

-

.

.

~~

g;/ t i

_ _. _. _.. -

_ _ _

................. _.....

... _

..

_ _ _...

stn Gmn&4 (YY*o.1).E...'/

M.r*o.r)a.9 z.'2-. oa.fe._. _, D. _

'

.

.

.

ur /< N. //

.

... _..

.......

-..

_

'8,, Ca n

.!H-..

C. e._I n...c. @ e - v_-y"~._ a w_

,.,3. _. _,

,

,

-

-

- - _.

-

_

...

SJff//hY

.

.

.. _..

-...

.-

_. _.

.

S. - PO.. - Q.t.s.*._o.. e.M.....e.__ '-/ _

pf*1)e..y.l. n_.>.__: a. _ a. D.

_

.-

..

.

l l

_

___

.

-

..

.....

.

..

C -Go (l.u *o.l'Q.E-6

< /. 2. e. s~ l yg _. _ - ~,,, _ _-.

-

-

,

.

.

. < e. t..E 6

!...i l l

.

.

_

Cs -/JY (l.69*o.lb) c.- 6

.'

--

_

Cs -/37 (2. Gs- * 00D E-3-'.,(:),.3.do. 4. ).E_. h_.

.

. 3 2,_.) p.t _./.2

.

.

.

'

h.rY (p. 3 s.s).e.7.

....... _ ~.

_3_'.

.

o

.

_.

. -... _ _

_

...

.

......

_

..

.

6 /c6 (4 &d /.t.) c-6.._ )l.s c 9 er.,-y _

_.,3.

. - _,...-

.

$h -t2.s~ (3.%s.10) E. l-l Q. o. +o. 2.).5.- y.I.f....q. Q1....ll

.o p

.

.

.

,

.

... _ _.

.

.

.

,

..

...

..

_

.

... _ _...

... _ _......

_.

_

._.

s

...u.

}

'

I

'

.

..

_.....

...

I

.

,

I j

l

.

.

...

.~.___...

_.

I

_

_ _ _ _ - _ _ _ _ _ _ - _

i