IR 05000317/1982022

From kanterella
Jump to navigation Jump to search
Corrected IE Safeguards Insp Repts 50-317/82-22 & 50-318/82-18 on 820726-30.Noncompliance Noted:Vital Area Keys & Lock Nut Changed According to Security Plan.Details Withheld (Ref 10CFR73.21)
ML20028A350
Person / Time
Site: Calvert Cliffs  
Issue date: 10/05/1982
From: Gody A, Mckeown L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
Shared Package
ML20028A326 List:
References
50-317-82-22, 50-318-82-18, NUDOCS 8211180409
Download: ML20028A350 (1)


Text

{{#Wiki_filter:r C w.- U.S. NUCLEAR REGULATORY COMMISSION

REGION I

50-317/82-22 Report No.

50-318/82-18 50-317 DPR-53 Docket No.

50-318 License No. DPR-69 Safeguards Group IV Licensee: Baltimore Gas and Electric Company P.O. Box 1475 Baltimore, Maryland 21203 Facility Name: Calvert Cliffs Nuclear Power Plant, Units 1 and 2 . Inspection at: Lusby, Maryland Inspection conducted: July 26-30, 1982 Date of Last Physical Protection Inspection: April 12-16, 1982 Type of Inspection: Routine, Unannounced Physical Protection hMW) [/ [[ d u sern Inspectors:Liha/M. McKeown, Ph sical Protection Inspector date / /o/s /,e32_ Approved by: / dp{e . T. Godf, Thi e feguards Section, Technical Progr Branch Inspection Summary: Routine, unannounced physical protection inspection on July 26 - 30, 1982 (Combined Inspection No. 50-317/82-22 and 50-318/82-18).

Areas Inspected: Included a review of the following areas: Locks *, Keys and Combinations; Physical Barriers (Protected and Vital Areas); Security System Power Supply; Assessment Aids; Access Controls (Personnel, Packages and Vehicles); Detection Aids (Protected and Vital Areas); Alarm Stations and - Communications. Also included a followup to previously identified inspector followup items.and an unresolved item.

The inspection involved 36 inspector hours onsite by one NRC region-based inspector.

The inspection was initiated during regular duty hours; 4 inspection hours were performed during offshift periods.

Results: The licensee was found to be in compliance with NRC regulations except for the following violation: 1) Locks, Keys and Combinations: Failure to change vital area keys and locks in accordance with Security Plan requirements.

K Okhd ~ PDR }}