IR 05000315/1979001

From kanterella
Jump to navigation Jump to search
IE Insp Repts 50-315/79-01 & 50-316/79-01 on 790130-0201.No Noncompliance Noted.Major Areas Inspected:Radiological Environ Protection Program
ML17317B019
Person / Time
Site: Cook  
Issue date: 02/13/1979
From: Essig T, Greer R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML17317B018 List:
References
50-315-79-01, 50-315-79-1, 50-316-79-01, 50-316-79-1, NUDOCS 7903220482
Download: ML17317B019 (7)


Text

U.

S.

NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT

REGION III

Report No. 50-315/79-01; 50-316/79-01 Docket No. 50-315; 50-316 License No. DPR-58; DPR-74 Licensee:

American Electric Power Service Corp.

Indiana and Michigan Power Company 2 Broadway New York, NY 10004 Facility Name:

Donald C.

Cook Nuclear Power Plant Inspection At: Donald C.

Cook Site, Bridgman, MI

+l la% P Inspection Conducted:

January 30 February 1, 1979

~d.A Approved By:

T. H.

Es ig, Chief Environmental and Special Projects Section

~Sumamr Ins ection on Januar 30-Februar

1979 (Re ort No.

50-315/79-01'0-316/79-01)

Areas Ins ected:

Routine, unannounced radiological environmental protection inspection including review of program management; review of program results; and inspection of proper installation and operability of selected sampling stations.

The inspection involved 20 inspector-hours on site by one NRC inspector.

Results:

For the three areas inspected, no items of noncompliance or deviations were found.

'F 9 0 3 2 2 0 4 EZ-

i

)I N

DETAILS Persons Contacted

  • B. Svensson, Assistant Plant Manager
  • E. Smarella, Technical Supervisor
  • J. Stietzel, Quality Assurance Supervisor
  • T. Kriesel, Environmental Coordinator
  • D. Palmer, Plant Radiation Protection Supervisor W. Ketchum, Radiation Protection Technician
  • K. Baker, NRC Resident Inspector-

%

  • Denotes those present at exit interview.

2.

General This inspection consisted of an examination of the licensee's radiological environmental protection program; sample stations and locations; and program results.

The licensee's Appendix B Technical Specifications were utilized as the primary inspection criteria.

The inspector reviewed the results of the licensee's monitoring program for the period from July 1, 1977 to June 30, 1978.

3.

Licensee Action on Previous Ins ection Findin s a

~

(Closed) Infraction (050-315/77-20)

Collection of fish and sediment samples.

The inspector determined that fish and sediment samples were collected and analyzed as required from July 1, 1977 to June 30, 1978.

b.

(Closed) Infraction (050-315/77-20)

Sampling of background stations for milk.

The inspector determined that Amendment Nos.

26 and 8, for Units 1 and 2, dated November 8, 1978, have been issued to allow fewer than three background stations to be sampled for milk if fewer than three are available.

4.

Environmental Pro ram Mana ement Management controls for the radiological portion of the environ-mental protection X~ogram remain as described in a previous inspection report.

1/ IE Inspection Report No. 50-315/77-20 and No. 50-316/77-2 't P

a

~

l,

5.

Pro ram Results The inspector reviewed the contractor's reports of analytical results for the period of July 1, 1977 through June 30, 1978.

The inspector noted that reasons for missing samples were documented.

Except for certain samples not taken because of weather conditions and results discussed below, all samples required were taken and properly analyzed.

The inspector noted and discussed with the licensee several

unusual sample results.

However, no results in excess of.

regulatory limits were noted.

The inspector discussed the sampling of aqu'atic organism~/with the licensee.

As noted in a previous inspection report, aquatic organisms have not been naturally available in suffi-cient quantity to sample.

However, the licensee stated that algae were sampled from the riprap for the first time during the last half of 1978.

The inspector noted that a few sample results are missing.

Results of analyses for Sr-89 and Sr-90 for the last quarterly composite of particulate filters during 1977 were not reported.

Results of Sr-89 and Sr-90 quarterly analyses of lake water samples for July 1977 June 1978 were also not reported.

Various analytical results of milk samples for Sr-89 and Sr-90 during October-December 1977 were not reported.

This area will be reviewed during a future inspection to ensure that the missing sample results discussed above have been reported as required by Environmental Technical Specification 4.2.

This item is considered unresolved.

6.

Air Sam lin Stations The inspector discussed anomalous air volumes reported for various air sampling stations.

The licensee stated that some of the problems were caug~d by the previous sample collector, as discussed previousl Others were caused by a leaky diaphragm in the dry gas meter.

The meters are now being replaced as problems appear.

The inspector visited selected air monitoring stations.

Equip-ment appeared to be functioning, and calibrations were completed as required.

2/ Ibid.

3/ Ib.

Unresolved Items 8.

Unresolved items are matters about which more information is required in order to ascertain whether they are. acceptable items, items of noncompliance, or deviations.

An unresolved item disclosed during the inspection is discussed in Paragraph 5.

Exit Interview The inspector met with licensee representatives (denoted in Paragraph 1) at the conclusion of the inspection on February 1,

1979.

The inspector summarized the purpose, scope, an'd findings of the inspection.

The licensee acknowledged the missing sample results and stated that they will be included in the next annual repor a

\\

I ~

/

4~