IR 05000305/2008005
| ML20199B996 | |
| Person / Time | |
|---|---|
| Site: | Kewaunee |
| Issue date: | 10/18/1985 |
| From: | Wiedeman D NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | BAXTER TRAVENOL LABORATORIES, INC. |
| Shared Package | |
| ML20199B999 | List: |
| References | |
| SSD, NUDOCS 9901140179 | |
| Download: ML20199B996 (4) | |
Text
p.
'
$/11 CS
.
[T OCT 1 s 1985 Baxter Labs:
Baxter Parkway Deerfield, IL 60015 Gentlemen:
As a result of the inspection conducted on March 5 to August 5, 1985, a Form NRC-591, SAFETY INSPECTION,.is issued for your NRC general license.
You
- f6 will note.that this form indicates that no item of noncompliance was found.
It is not necessary that you acknowledge receipt of this form.
-
The enclosed copy of our inspection report identifies areas examined during
- the inspection.
Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and telephone interviews with your personnel.
s i
If you have any questions or require clarification on any of the information stated above, you may contact us at (312) 790-5616.
Thank you for your cooperation.
Sincerely, c
p
- T^
,
,
D. G. Wiedeman, Chief
'
Nuclear Materials Safety Section 1 Enclosures:
As stated bec w/ enclosures:
~
L. Cobb, OIE
.
.S.-Baggett, NMSS
.
\\
9901140179 851018-PDR RC
SSD PDR i, of
$
h
[c2-RIII
,
Wiedeman/1d 10/16/85,
_
. - _.. _
- _.. _.... _ _..... _ _ _ _. _ _. -. - _. _. _. -... _ _ _ _ _. _ __
. _. _.. _
,
,
_
$
%
.
,3.-r Q
GENERAL' LICENSE GAUGE DATA COLLECTION FORM I
' 1. -
Name and Acaress of. General Licensee:
. Baxter Labs (Now Travenol Laboratories, Inc.)
.
l Baxter Parkway-
'-
,
Deerfield..IL 60015
'
,
E j
(312).948-4248
2.-
-Principal Business of Licensee:
.
Manufacturer of various. laboratory supplies.
3.
~ Purpose for which_ gauge (s) are used (e.g., measurement of level, density,
.
flow, thickness,etc.):
'
I-Thickness control.
!
. 4.
Gauge Specifics:
'
a.
Manufacturer:
LFE Corporation b..
Model Number:
SN-78 Source Serial Number 8274 I
.SN-78 Source Serial Number 8295 l
c.
Isotope / Activity:
Both sources are krypton-85/1200 millicuries
,
d.
Date Received:
April 1970 and November 1970 e.-
Date Replaced:
N/A. JVs /Ite'/W
,
.
l5.
Name of specific licensee that installed gauge:
p.
Unknown.
.
6.~
DoesthegaugehaveLadura5Ie,'legibleandvisiblelabel:
-
Unknown.
+
i
' 7.
Was an Initial Radiation Survey performed at time of installation and do they have a record (list results) NOTE:
records only required for 2 year. period:
U.
Unknown.
-
- 8.
Leak Tests:
.
L a.'. -Have the tests been performed (list results):
Unknown.:
.
j b.
Name of firm / person conducting test:
}
Unknown.
'
!.
![
,
'
~
,
-
,.
-
-
,_
-
.
.., -
.
-
- - -.
.
-... -
__ -. -
l'
i
.
q.
'
iQ-
.
c.
Are~ records available of tests (list date of last test):
].
NOTE:
records only maintained for 2 years
$
No test records available.
.
9.-
Operational Test of Gauge:
)
- a.
Have any tests been performed of the on/off mechanism:
!
$
Unknown, except that LFE Corporation serviced the unit in Belgium in 1975.
,
!
b.
Name of firm / person who performed test:
l iL Unknown, except LFE Service in 1975 on the unit in Belgium.
i
.
.
'
l c.
Are records maintained'of tests (list dates):
I No records available as per phone call from Iris'Kanter, August 5, l
1985.
j 10.
Has the gauge been moved from it's original location? If so, by whom:
Gauge SN-78 with Source Serial Number 8274 was returned to LFE Corporation in August 1980.* Gauge SN-76 with Source Serial Number 8295 was shipped directly to Belgium in November 1970, serviced by LFE Corporation at Travenol Labs in Belgium in 1975 and is still in use there currently.
11.
Does the licensee have personnel who are responsible for assuring compliance with the General License Conditions (10 CFR 31, 31.5(c)
(1 through 10):
Yes, Iris Kanter, Corporate. Industrial Hygienist 12.
Has the. licensee made any transfers of gauges:
Yes, Gauge SB-7N with Source-Serial Number 8274 was returned to LFE Corporation in August, 1980.
13.
Name and Address of Gauge Manufacturer:
LFE Corporation 55 Green Street Clinton, MA 01510
.(617) 365-4511
Mr. Bill Prendergast of LFE Corporation stated in a telephone conversation
(September 12,1985) that the gauge was received on October 21, 1980.
i
. _ _. _. _ _ _ _..
_. _.. _. _ _. _ _ _. _ _ _. _ _ _.. _
..... _ _. _ _ _ _ _. _. _... _ _
_
..
.
...
4 h f
14.
Onsite inspection of gauge (s) (list observations / measurements):
Notes:
Iris Kanter, Corporate Industrial Hygienist for Travenol Labs, Inc. of Deerfield (formerly Baxter Labs) indicated to me by phone on August 5, 1985 that she had no test records on the unit being used in Belgium and that this unit was not subject to NRC control but rather subject to the Laws of Belgium.
15.
Name of ORAU Reviewe
'l
-"2 dddiy
[NYf
_
.
'/
'
Date 16.
Signature and Date of NRC Reviewer
,
4 :^^
/ov7ff
.
.
'/
Date
<
l
..
3