IR 05000295/2012011

From kanterella
Jump to navigation Jump to search
IR 05000295-12-011(DNMS); 05000304-12-011(DNMS) for Zion Nuclear Power Station
ML13046A140
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 02/13/2013
From: Christine Lipa
NRC/RGN-III/DNMS/MCID
To: Daly P
ZionSolutions
Slawinski W
References
IR-12-011
Download: ML13046A140 (4)


Text

February 13, 2013

SUBJECT:

NRC INSPECTION REPORT 05000295/12011(DNMS); 05000304/12011(DNMS) -

ZION NUCLEAR POWER STATION

Dear Mr. Daly:

On January 15, 2013, the U.S. Nuclear Regulatory Commission (NRC) completed inspection activities for the fourth calendar quarter of 2012 at the permanently shut-down Zion Nuclear Power Station in Zion, Illinois. The purpose of the inspection was to determine whether decommissioning activities were conducted safely and in accordance with NRC requirements.

The enclosed report presents the results of this inspection, which were discussed onsite with Messrs. Thurman and Beckman on February 6, 2013.

During the inspection period, the NRC inspectors reviewed aspects of the radiation protection program; radioactive waste processing and transportation including the shipment of irradiated hardware in the NRC approved Type B cask; and the associated measures to meet the requirements imposed by NRC Order EA-05-006 for increased control of certain quantities of radioactive material during transport. In addition, the inspectors evaluated your staffs performance and subsequent critique during a planned emergency preparedness exercise.

The inspection consisted of an examination of activities at the site as they relate to safety and compliance with the Commissions rules and regulations. Areas examined during the inspection are identified in the enclosed report. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observation of work activities, independent radiation measurements, and interviews with personnel.

Based on the results of this quarterly inspection, no violation of NRC requirements was identified.

In accordance with Title 10 of the Code of Federal Regulations (CFR) 2.390 of the NRC's

"Rules of Practice," a copy of this letter will be made available electronically for public inspection in the NRC's Agencywide Document Access and Management System (ADAMS), accessible

The Enclosure Contains Sensitive Unclassified Non-Safeguards Information. When separated from the enclosure, this transmittal letter is decontrolled. SECURITED RELATED INFORMATION

from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. Since the enclosed inspection report contains security related information and must be protected from unauthorized disclosure, the enclosure will not be made available for public inspection.

We will gladly discuss any questions you may have regarding this inspection.

Sincerely,

/RA/

Christine Lipa, Chief Materials Control, ISFSI, and Decommissioning Branch Division of Nuclear Materials Safety

Docket Nos. 050-00295; 050-00304 License Nos. DPR-39; DPR-48

Enclosure:

Inspection Report No. 05000295/12011(DNMS);

05000304/12011(DNMS) (Non Public)

cc w/encl: Patrick Thurman, ZionSolutions, LLC

Gary Bouchard, ZionSolutions, LLC

Alan Parker, EnergySolutions

John Christian, EnergySolutions

cc w/o encl: Suzi Schmidt, Illinois General Assembly

JoAnn D. Osmond, Illinois General Assembly

Barry A. Burton, Lake County Administrator

Mark C. Curran, Jr., Lake County Sheriff

Laurie Cvengros, Village Clerk, Village of Beach Park, Illinois

Willard R. Helander, Lake County Clerk

Jana Lee, Village Clerk, Village of Winthrop Harbor, Illinois

Judy L. Mackey, City Clerk, City of Zion, Illinois

Irene T. Pierce, Lake County, Illinois

Kent McKenzie, Lake County Emergency Management Agency SECURITY RELATED INFORNMATION Attachment from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. Since the enclosed inspection report contains security related information and must be protected from unauthorized disclosure, the enclosure will not be made available for public inspection.

We will gladly discuss any questions you may have regarding this inspection.

Sincerely,

/RA/

Christine Lipa, Chief Materials Control, ISFSI, and Decommissioning Branch Division of Nuclear Materials Safety

Docket Nos. 050-00295; 050-00304 License Nos. DPR-39; DPR-48

Enclosure:

Inspection Report No. 050-00295/12-011(DNMS);

050-00304/12-011(DNMS) (Non Public)

cc w/encl: Patrick Thurman, ZionSolutions, LLC

Gary Bouchard, ZionSolutions, LLC

Alan Parker, EnergySolutions

John Christian, EnergySolutions

cc w/o encl: Suzi Schmidt, Illinois General Assembly

JoAnn D. Osmond, Illinois General Assembly

Barry A. Burton, Lake County Administrator

Mark C. Curran, Jr., Lake County Sheriff

Laurie Cvengros, Village Clerk, Village of Beach Park, Illinois

Willard R. Helander, Lake County Clerk

Jana Lee, Village Clerk, Village of Winthrop Harbor, Illinois

Judy L. Mackey, City Clerk, City of Zion, Illinois

Irene T. Pierce, Lake County, Illinois

Kent McKenzie, Lake County Emergency Management Agency

DISTRIBUTION w/encl:

See next page

ADAMS Accession Number: ML13046A140 DOCUMENT NAME: G:\\DNMSIII\\Work in progress\\IR - ZION Insp Rpt 2012-011 DNMS CoverLTR.docx Publicly Available Non-Publicly Available Sensitive Non-Sensitive To receive a copy of this document, indicate in the concurrence box "C" = Copy without attach/encl "E" = Copy with attach/encl "N" = No copy OFFICE RIII DNMS

RIII DNNMS

RIII DNMS

RIII DNMS

NAME WJSlawinski:ps*WJS JTapp*WJS for LRodriguez*WJS for CLipa*CAL DATE 02/13/13 02/13/13 02/13/13 02/13/13 OFFICIAL RECORD COPY SECURITY RELATED INFORNMATION

2 Letter to Patrick Daly from Christine A. Lipa dated February 13, 2013

SUBJECT: NRC INSPECTION REPORT 050-00295/12-011(DNMS); 050-00304/12-011(DNMS) -

ZION NUCLEAR POWER STATION

DISTRIBUTION w/encl:

Bruce Watson John Hickman Anne Boland Jared Heck Harral Logaras Alan Barker Carol Ariano Linda Linn Tammy Tomczak MCID Branch