Forwards Reactive Insp Rept 50-289/89-17 on 890815-16 & Notice of Violation
ML20247P695
Person / Time
Site: Crane 
Issue date: 09/19/1989
From: Ronald Bellamy
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Hukill H
GENERAL PUBLIC UTILITIES CORP.
Shared Package
ML20247P701 List:
References
NUDOCS 8909270252
Download: ML20247P695 (2)


Text

- _ - - _ _

b

.

.

SEp j 9 1999 Docket No. 50-289 GPU Nuclear Corporation-ATTN: Mr. H.D. Hukill Vice President and Director of TMI-l P.O. Box 480

'Middletown, Pennsylvania 17057 Gentlemen:

,

Subject: Inspection Report No. 50-289/89-17 This refers to the reactive inspection conducted by Dr. Jason C. Jang of this office on August 15-16 1989 of activities authorized by NRC License No.

DPR-50 at the Three Mile Island Nuclear Station, Unit 1 and to the discussions of our findings held by Dr. Jang with Mr. R. Shaw and other members of your staff at the conclusion of the inspection, and to a subsequent telephone discussion between Drs. Bores and Jang of'this office with Mr. Hae.sler and other members of your staff on September 7, 1989.

Areas examined during this inspection are described in the NRC Region I Inspection Report, which is enclosed with this letter. The inspection consisted of an examination of corrective actions for the unresolved item relative to representative' iodine sampling identified during a previous inspection conducted in November, 1988 (50-289/88-30). One portion of that item remains unresolved and you are requested to review that portion and respond within 30 days of the date of this letter on actions planned.

it appears that one of your Based on the results of this inspection, liance with NRC requirements, as set activities was not conducted in full comp forth in the Notice of Violation, enclosed herewith as Appendix A.

This violation has been categorized by severity level in accordance with the 10 CFR Part 2, Appendix C (y and Procedure for NRC Enforcement Actions",

" General Statement of PolicEnforcement Policy). This notice is sent to you

)ursuant to the provisions of Section 2.201 of the NRC's " Rules of Practice,"

) art 2, Title 10, Code of Federal Regulations. Although Section 2.201 requires you to submit to this office, within 20 days of your receipt of this notice, a written statement of explanation, we note that this violation had i

been corrected and those actions were reviewed during this inspection.

~

Therefore, no response with respect to this matter is required.

'

The resnonse requested by this letter is not subject to the clearance procedures uf the Dffice of Management and Budget as required by the Paperwork Reduction M b b!!k N b h b F

h

ha y*, f g

,

8909270252 890919 hh

.

"

FDR ADOCK 05000289 I

Q FDC

-

g.,-_,--

- - - - - - -

- _ _ _

_

_

_

-_,

'4',

-

.

.. "

-

SEP19;ggg GPU'Nuc1ea'r Corporation

Act of 1980, PL 96-511. Your cooperation with us in this matter is

-

appreciated.

Sincerely,

.J;id?.QnedCy:

hcald R. Dimy Ronald R. Bellamy, Chief Facilities Radiological Safety and Safeguards Branch Division of Radiation Safety and Safeguards Enclosures: 1. Appendix A, Notice of Violation 2. NRC Region I Inspection Report No. 50-289/89-17 cc w/ encl:

T. G. Broughton, Operations and Maintenance Director, THI-1

'C. W. Smyth, Manager, TMI-l Licensing R. J. McGoey, Manager, PWR Licensing E. L. Blake, Jr., Esquire T. F. Demmitt, Deputy Director TMI-2 J.1J.Byrne, Manager,gandNuclearSafetyDirector R. E. Rogan,.Licensin TMI-2 Licensing W. ' J. Marschall Manager, Plant Operations S. Levin,DefuelingDirector

.J. B. Lieberman G.A.Kuehn,TMIEsquire 2 Site Operations Director TMI-Alert (TMIA)

Susquehanna Valley Alliance (SVA)

Public Document Room (PDR) (LPDR)

local Public Document Room Nuclear Safety Information Center (NSIC)

-

NRC Resident Ins)ector

' -

Commonwealth of Pennsylvania

.bec w/ encl:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o enc 1)

DRP Section Chief R.- Hernan, PM, NRR'

K. Abraham, PA0 S. Lewis, 0GC Michael Hasnik, PM, TMI 2

-

M DRSS:

Dn : I DRSS:RI JANG BORES BELLAf1Y

l'

9/ /(

9/ 1 8 /89 9/19 /89

"DiffiA!!!!Cfli!B 89Y"

_

- _ - - -