IR 05000269/2006007

From kanterella
Jump to navigation Jump to search
NRC Inspection Report 05000269/2006007, 05000270/2006007, and 05000287/20060007 - SGI Removed
ML062140293
Person / Time
Site: Oconee  Duke Energy icon.png
Issue date: 07/07/2006
From: Brian Bonser
Division of Reactor Safety II
To: Brandi Hamilton
Duke Energy Carolinas, Duke Power Co
References
IR-06-007
Download: ML062140293 (4)


Text

uly 7, 2006

SUBJECT:

OCONEE NUCLEAR STATION - NRC INSPECTION REPORT 05000269/2006007, 05000270/2006007, AND 05000287/20060007

Dear Mr. Hamilton:

On June 9, 2006, the U. S. Nuclear Regulatory Commission (NRC) completed the onsite portion of an inspection at your Oconee Nuclear Plant. Portions of inspection procedures 71130.01, Access Authorization, and 71130.08, Fitness for Duty, were completed at the Duke Energy Corporate Office on January 13, 2006. The enclosed report documents the inspection findings, which were discussed with Mr. P. Fowler, at the corporate office, on January 13, 2006, and with Mr. D. Baxter, at the Oconee Nuclear Plant and other members of your staff on June 8, 2006.

This inspection examined activities conducted under your license as they relate to security and compliance with the Commissions rules and regulations and with the conditions of your license.

The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel.

Based on the results of this inspection no findings of significance were identified.

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system, ADAMS. ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). However, because of the security-related concerns contained in the enclosure, and in accordance with 10 CFR 2.390 a copy of this letters enclosure will not be available for public inspection.

DOCUMENT CONTAINS ENCLOSURE CONTAINS UPON SEPARATION THIS PAGE IS DECONTROLLED

DEC 2 DOCUMENT CONTAINS Should you have any questions concerning this letter, please contact us.

Sincerely,

/RA/

Brian R. Bonser, Chief Plant Support Branch Division of Reactor Safety Docket No.: 50-269, 50-270, 50-287 License No: DPR-38, DPR-47, DPR-55 Enclosure: NRC Inspection Report No. 05000269/2006007, 05000270/2006007 And 05000287/2006007 w/Attachment: Supplemental Information (Safeguards Information)

cc w/encl:

B. G. Davenport Compliance Manager (ONS)

Duke Energy Corporation ON03RC 7800 Rochester Highway Seneca, SC 29672 cc w/o encl:

Lisa Vaughn Associate General Counsel Duke Energy Corporation 526 South Church Street-EC07H Charlotte, NC 28202 Timika Shafeek-Horton Assistant General Counsel Duke Energy Corporation 526 South Church Street-EC07H Charlotte, NC 28202 (cc w/o encl contd - See page 3)

DOCUMENT CONTAINS ENCLOSURE CONTAINS UPON SEPARATION THIS PAGE IS DECONTROLLED

DEC 3 DOCUMENT CONTAINS (cc w/o encl contd)

David A. Repka Winston & Strawn LLP 1400 L Street, NW Washington, D. C. 20005 Beverly Hall, Acting Director Division of Radiation Protection N. C. Department of Environmental Health & Natural Resources 3825 Barrett Drive Raleigh, NC 27609-7721 Henry J. Porter, Assistant Director Div. of Radioactive Waste Mgmt.

S. C. Department of Health and Environmental Control 2600 Bull Street Columbia, SC 29201 County Supervisor of Oconee County 415 S. Pine Street Walhalla, SC 29691-2145 Lyle Graber, LIS NUS Corporation 2650 McCormick Drive Clearwater, FL 34619-1035 R. L. Gill, Jr., Manager Nuclear Regulatory Issues and Industry Affairs Duke Energy Corporation 526 S. Church Street Charlotte, NC 28201-0006 (cc w/encl contd - See page 4)

DOCUMENT CONTAINS ENCLOSURE CONTAINS UPON SEPARATION THIS PAGE IS DECONTROLLED

DEC 4 DOCUMENT CONTAINS (cc w/o encl contd)

Peggy Force Assistant Attorney General N. C. Department of Justice P. O. Box 629 Raleigh, NC 27602 Charles Brinkman Director, Washington Operations Westinghouse Electric Company 12300 Twinbrook Parkway, Suite 330 Rockville, MD 20852 DOCUMENT CONTAINS ENCLOSURE CONTAINS UPON SEPARATION THIS PAGE IS DECONTROLLED