November 21, 2002
SUBJECT:
MONTICELLO NUCLEAR GENERATING PLANT USNRC INITIAL LICENSE EXAMINATION REPORT 50-263/02-301(DRS)
Dear Mr. Forbes:
On October 18, 2002, U.S. Nuclear Regulatory Commission (USNRC) examiners completed initial operator licensing examinations at your Monticello Nuclear Generating Plant. The enclosed report documents the results of the examination which were discussed on October 18, 2002, with you and other members of your staff.
The USNRC examiners administered an initial license examination operating test during the week of October 14, 2002. A written examination was administered by Monticello Plant training personnel on October 18, 2002. One Reactor Operator (RO) and two Senior Reactor Operator (SRO) applicants were administered license examinations. The results of the examinations were finalized on November 4, 2002. Two applicants passed all sections of their respective examinations and were issued applicable operator licenses. One SRO applicant failed the written examination and was issued a proposed license denial letter.
In accordance with 10 CFR Part 2.790 of the USNRCs "Rules of Practice," a copy of this letter and its enclosures will be available electronically for public inspection in the USNRC Public Document Room or from the Publicly Available Records (PARS) component of USNRCs document system (ADAMS). ADAMS is accessible from the USNRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room). We will gladly discuss any questions you have concerning this examination.
Sincerely,
/RA/
Roger D. Lanksbury, Chief Operations Branch Division of Reactor Safety Docket No. 50-263 License No. DPR-22
Enclosures:
1.
Operator Licensing Examination Report 50-263/02-301(DRS)
2.
Simulation Facility Report 3.
Written Examinations and Answer Keys (RO & SRO)
REGION III==
Docket No:
50-263 License No:
DPR-22 Report No:
50-263/02-301(DRS)
Licensee:
Nuclear Management Company, LLC Facility:
Monticello Nuclear Generating Plant Location:
2807 West Highway 75 Monticello, MN 55362 Dates:
October 14 through October 18, 2002 Examiners:
D. McNeil, Reactor Engineer C. Phillips, Reactor Engineer Approved by:
Roger Lanksbury, Chief Operations Branch Division of Reactor Safety
SUMMARY OF FINDINGS
ER 05000263-02-301(DRS); Nuclear Management Company, LLC; on 10/14-18/02; Monticello
Nuclear Generating Plant. Initial License Examination Report.
The announced operator licensing initial examination was conducted by regional USNRC examiners in accordance with the guidance of NUREG-1021, Operator Licensing Examination Standards for Power Reactors, Revision 8, Supplement 1.
Examination Summary:
- Two applicants passed all sections of their respective examinations and were issued applicable operator licenses. One Senior Reactor Operator applicant failed the written examination and was issued a proposed license denial letter (Section 4OA5.1).
REPORT DETAILS
OTHER ACTIVITIES (OA)
4OA5 Other
.1 Initial Licensing Examinations
a. Examination Scope
The USNRC examiners conducted an announced operator licensing initial examination during the week of October 14, 2002. The plants training staff used the guidance established in NUREG-1021, Operator Licensing Examination Standards for Power Reactors, Revision 8, Supplement 1, to prepare the examination outline and to develop the written examination and operating test. The USNRC examiners administered the operating test during the weeks of October 14, 2002. Monticello Plant training staff members administered the written examination on October 18, 2002. One Reactor Operator and two Senior Reactor Operator applicants were examined.
b. Findings
Written Examination The licensee developed the written examination. During the initial review of the examination, the examiners determined that the examination, as submitted by the licensee, was within the range of acceptability expected for a proposed examination.
During examination validation the week of July 29, 2002, changes agreed upon between the USNRC and the licensee were incorporated according to the guidance contained in NUREG-1021.
The licensee graded the examination on October 18, 2002, and conducted a review of each question to determine accuracy and validity of the examination questions. The licensee had no post examination comments on the written examination.
Operating Test The USNRC examiners determined that the operating test, as originally submitted by the licensee, was within the range of acceptability expected for a proposed examination.
Examination changes made during the validation of the operating test were agreed upon between the USNRC and the licensee, and were made according to NUREG-1021.
Examination Results One Reactor Operator applicant and two Senior Reactor Operator applicants were administered written examinations and operating tests for initial operator licensing. Two applicants passed all sections of their respective examinations and were issued applicable operator licenses. One Senior Reactor Operator applicant failed the written examination and was issued a proposed license denial letter. The applicant will have approximately 20 days to appeal the proposed denial.
.2 Examination Security
a. Examination Scope
The examiners reviewed and observed the licensees implementation of examination security requirements during the examination preparation and administration.
b. Findings
The licensees implementation of examination security requirements during examination preparation and administration were acceptable and met the guidelines provided in NUREG 1021, Operator Licensing Examination Standards for Power Reactors. No violations of 10 CFR 55.49 occurred during the examination preparation and administration.
4OA6 Meetings
Exit Meeting The chief examiner presented the examination team's preliminary observations and findings on October 18, 2002, to Mr. Forbes and other members of the Operations and Training Department staff. The chief examiner asked the licensee whether any materials examined during the inspection should be considered proprietary. No proprietary information was identified.
KEY POINTS OF CONTACT Licensee J. Forbes, Site Vice President G. Allex, Examination Developer W. Cheever, General Supervisor Operations Training J. Grubb, Operations Manager K. Markling, Control Room Supervisor J. Shriver, Principle Engineering Analyst - Simulator J. Windschill, Training Manager NRC D. Kimble, Resident Inspector, Monticello Plant ITEMS OPENED, CLOSED AND DISCUSSED Opened None Closed None Discussed None LIST OF ACRONYMS USED ADAMS Agency-Wide Document Access and Management System DRS Division of Reactor Safety USNRC U.S. Nuclear Regulatory Commission PARS Publicly Available Records RO Reactor Operator SRO Senior Reactor Operator LIST OF
DOCUMENTS REVIEWED
None
SIMULATION FACILITY REPORT
Facility Licensee:
Monticello Plant
Facility Docket No.:
50-263
Operating Tests Administered:
October 14 - 17, 2002
The following documents observations made by the USNRC examination team during the initial
operator license examination. These observations do not constitute audit or inspection findings
and are not, without further verification and review, indicative of non-compliance with 10 CFR
55.45(b). These observations do not affect USNRC certification or approval of the simulation
facility other than to provide information which may be used in future evaluations. No licensee
action is required in response to these observations.
During the conduct of the simulator portion of the operating tests, the following items were
observed:
ITEM
DESCRIPTION
None
WRITTEN EXAMINATIONS AND ANSWER KEYS (RO/SRO)
RO/SRO Initial Examination ADAMS Accession # ML023180427