IR 05000259-06-012, on 05/30/2006-06/02/2006, for Browns Ferry Nuclear Plant Unit 1, Licensee Engineering Activities Associated with the Unit 1 Recovery Special Program for Fire Protection and the Special Program for Cable Installation and
ML061950179
Person / Time
Site: Browns Ferry 
Issue date: 07/13/2006
From: Payne D
NRC/RGN-II/DRS/EB2
To: Singer K
Tennessee Valley Authority
References
IR-06-012
Download: ML061950179 (21)


Text

July 13, 2006

SUBJECT:

BROWNS FERRY NUCLEAR PLANT UNIT 1 RECOVERY - NRC INSPECTION REPORT 05000259/2006012

Dear Mr. Singer:

On June 2, 2006, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection associated with recovery activities at your Browns Ferry Unit 1 reactor facility. The enclosed inspection report documents the inspection results, which were discussed on June 2, 2006, with Mr. M. Bajestani and other members of your staff.

This inspection examined activities conducted under your Unit 1 license as they relate to safety and compliance with the Commissions rules and regulations and with the conditions of your license and also with fulfillment of Unit 1 Regulatory Framework Commitments. The inspection focused on the Special Program for Fire Protection. The inspectors reviewed selected procedures and records, observed activities, walked-down facilities, and interviewed personnel.

Based on the results of this inspection, no violations or findings of significance were identified.

However, the report includes one unresolved item related to the intended use of an extensive number of local operator actions during implementation of fire response procedures.

Additionally, this report contains the final disposition of the May 12, 2006, cable installation and separation inspection. The inspection identified a non-cited violation of 10 CFR 50, Appendix B, Criterion III for failure to assure that the design change measures for relocating 480 Volt Diesel Auxiliary Board B Division II cables met divisional separation requirements. However, because the violation was entered into your corrective action program, the NRC is treating the violation as an NCV consistent with Section VI.A of the NRC Enforcement Policy. If you contest any non-cited violation or finding in the enclosed report, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the United States Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington DC 20555-0001; with copies to the Regional Administrator, Region II; the Director, Office of Enforcement, United States Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC Senior Resident Inspector at the Browns Ferry Nuclear Plant.

TVA

In accordance with 10 CFR 2.390 of the NRCs Rules of Practice, a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system (ADAMS).

ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

D. Charles Payne, Chief Engineering Branch 2 Division of Reactor Safety Docket No. 50-259 License No. DPR-33

Enclosure:

Inspection Report 05000259/2006012 w/Attachment: Supplemental Information

REGION II==

Docket No:

50-259 License No:

DPR-33 Report No:

05000259/2006012 Licensee:

Tennessee Valley Authority (TVA)

Facility:

Browns Ferry Nuclear Plant (BFNP), Unit 1 Location:

Corner of Shaw and Nuclear Plant Roads Athens, AL 35611 Dates:

May 30 - June 2, 2006 Inspectors:

G. MacDonald, Senior Reactor Inspector Region II (RII) -

Team Leader R. Bernhard, Senior Reactor Analyst, RII R. Gallucci, Senior Fire Probabilistic Risk Assessment Engineer, Office of Nuclear Reactor Regulation (NRR)

L. Mellen, Senior Project Engineer, Browns Ferry Unit 1 Restart, RII P. Qualls, Fire Protection Engineer, NRR N. Staples, Reactor Inspector, RII Approved by:

D. Charles Payne, Chief Engineering Branch 2 Division of Reactor Safety

ii

EXECUTIVE SUMMARY

Browns Ferry Nuclear Plant, Unit 1

NRC Inspection Report 05000259/2006012 This inspection included aspects of licensee engineering activities associated with the Unit 1 Recovery Special Program for Fire Protection and the Special Program for Cable Installation and Separation. The inspection program for the Unit 1 Restart Program is described in NRC Inspection Manual Chapter 2509. Information regarding the Browns Ferry Unit 1 Recovery and NRC Inspections can be found at http://www.nrc.gov/NRR/OVERSIGHT/ASSESS/bf1-recovery.html.

Inspection Results - Engineering

  • A Severity Level IV non-cited violation (NCV) of 10 CFR 50, Appendix B, Criterion III was identified for failure to assure that the design change measures, for relocating 480 Volt Diesel Auxiliary Board B Division II cables to a separate terminal block six inches from Division I cables, were correctly translated into work instructions. This resulted in the as-built configuration for cables PL2817-II and PL2824-II (in the plant) deviating from design drawings. Due to the need to inspect additional examples for external and internal separations, additional inspections will be required to determine if this Special Program is being implemented satisfactorily. (Section E1.4)
  • The team reviewed the Browns Ferry Nuclear Plant (BFNP) licensing basis for 10 CFR 50, Appendix R,Section III.G.2 post-fire operator manual actions (OMAs) to accomplish safe shutdown (SSD) in Section III.G.2-designated fire areas. No exemption requests were granted for Section III.G.2 post-fire OMAs so the licensee should consider the OMAs as compensatory measures and follow the clarifications regarding OMAs as delineated in the March 6, 2006 Federal Register Notice. BFNP has identified those post-fire SSD OMAs which are performed outside the main control room (MCR) in Section III.G.2 fire areas for BFNP Units 1, 2 and 3 and placed them in the corrective action program (CAP). Therefore, unresolved item (URI)05000259/2005016-01 is closed. (Section E1.1)
  • The team determined that BFNP had performed a risk evaluation of the fire areas employing 10 CFR 50, Appendix R, post-fire operator manual actions (OMAs) outside the MCR to achieve SSD using the guidance of NRC IMC 0609, Appendix F, Fire Protection Significance Determination Process. The risk evaluation was not complete as it did not address the risk contribution of transient combustible fires, the risk impact of potential fire induced spurious equipment operation, or consider the potential for common OMAs (i.e., the same or very similar OMAs used in multiple fire areas, or in the same fire area, but in response to different fire initiators) to be risk significant. The team determined that the risk evaluation also needed to document the deviations from the fire protection SDP process. Problem Evaluation Report (PER) 104418 was initiated for tracking the incomplete risk evaluation. (Section E1.2)

iii

REPORT DETAILS

II. Engineering E1 Conduct of Engineering E1.1 Review of Browns Ferry Nuclear Plant Post-Fire Operator Manual Actions for Safe Shutdown in 10 CFR 50, Appendix R,Section III.G.2 Fire Areas (37550)

a. Inspection Scope

The team reviewed the BFNP Fire Protection design and licensing basis documents to determine if post-fire OMAs to achieve Safe Shutdown (SSD) for a fire in 10 CFR 50, Appendix R,Section III.G.2 fire areas were approved by the NRC. NRC URI 05000259/2005016-01, Use of Local Operator Actions to Achieve Safe Shutdown, was reviewed. The team reviewed the BFNP operating license relative to the Unit 1 Fire Protection Program and examined the actions Browns Ferry has taken regarding fire protection OMAs. Documents reviewed are listed in the Attachment.

b. Observations and Findings

The team determined that BFNP still relied on OMAs to accomplish post-fire SSD for fires in Appendix R, III.G.2 fire areas for Units 1, 2, and 3. BFNP has identified the post-fire SSD OMAs performed outside the main control room (MCR) in Section III.G.2 fire areas for BFNP Units 1, 2, and 3. The Section III.G.2 post-fire SSD OMAs performed outside MCR have been entered into the BFNP site corrective action program (CAP) as PER 101631, Appendix R Section III.G.2 Operator Manual Actions.

Through a review of BFNP Fire Protection licensing basis documents, the team determined that no exemption requests for Section III.G.2 post-fire SSD OMAs outside the MCR were submitted or approved for BFNP Units 1, 2, or 3. NRC Safety Evaluation Report (SER), Safety Evaluation Of Post-Fire Safe Shutdown Capability And Issuance Of Technical Specification Amendments For The Browns Ferry Nuclear Plant Units 1, 2 and 3 dated November 2, 1995, described manual actions both inside and outside the MCR necessary for SSD of Units 2 and 3 for a fire in any location except fire area 16 (a 10 CFR 50, Appendix R,Section III.G.3 area). While the November 2, 1995, SER described the principal post-fire OMAs necessary for SSD in Section III.G.2 fire areas for combined operation of BFNP Units 2 and 3, the OMAs outside the MCR are still considered unapproved because no exemption requests have been granted to accept these actions. A Federal Register Notice (FRN) dated March 6, 2006, discusses use of unapproved post-fire local OMAs for SSD in Section III.G.2 fire areas. The FRN indicates that unapproved post-fire OMAs, which are feasible and reliable, should be considered as compensatory measures and do not comply with Section III.G.2. The FRN discusses enforcement discretion regarding the Section III.G.2 OMAs, and outlines that licensees must identify the Section III.G.2 OMAs, place them in the CAP within six months of the FRN date and implement an approved Section III.G.2 SSD method within three years of the FRN date, (March 6, 2006).

Because the BFNP Section III.G.2 post-fire OMAs are not approved within the BFNP licensing basis, URI 05000259/2005016-01 will be closed with no violation as BFNP will be able to follow the industry-wide post-fire OMA guidance in the March 6, 2006, FRN notice regarding discretion for resolution of Section III.G.2 post-fire OMAs.

The current BFNP fire protection program describes compensatory measures to be implemented for fire protection program impairments. The current approved compensatory measure is a fire watch. The FRN indicates that the Section III.G.2 post-fire SSD OMAs should themselves be considered compensatory measures, if shown to be feasible and reliable. The BFNP fire protection program needs to be revised to allow the use of OMAs as an approved compensatory measure.

c. Conclusions

The team reviewed the BFNP licensing basis for Appendix R,Section III.G.2 post-fire OMAs to accomplish SSD in Section III.G.2 fire areas. BFNP has identified the post-fire SSD OMAs performed outside the MCR in Section III.G.2 fire areas for BFNP Units 1, 2 and 3 and placed them in the CAP. No exemption requests have previously been granted for III.G.2 post-fire OMAs. Thus the licensee needs to treat the OMAs as compensatory measures and follow the clarifications regarding OMAs provided in the March 6, 2006, Federal Register Notice. URI 05000259/2005016-01 is closed.

E1.2 Review of Significance Determination Process (SDP) Evaluation of Fire Scenarios in 10 CFR 50 Appendix R,Section III.G.2 Areas at Browns Ferry Nuclear Plant Units 1, 2 and (37550)

a. Inspection Scope

The team reviewed the BFNP risk assessment of Section III.G.2 fire areas which utilized post-fire OMAs outside the MCR to achieve SSD, to determine if the risk evaluation was performed pursuant to the guidance of NRC Inspection Manual Chapter (IMC) 0609, Appendix F, Fire Protection Significance Determination Process. Fire areas/fire zones 1-1, 1-5, and 25 were selected for review. The team performed walkdowns of the three selected fire areas and reviewed the risk assessment methodology, assumptions and data. Documents reviewed are listed in the Attachment.

b. Observations and Findings

The team determined that BFNP performed the risk evaluations in accordance with the guidance of NRC IMC 0609, Appendix F, with some deviations. The licensees evaluation concluded that all the areas evaluated appeared to be of very low risk significance.

The team concluded that the risk evaluation was not complete because it did not address the risk contribution of transient combustible fires and did not address the risk impact of potential fire-induced spurious equipment actuation. Additionally, the evaluation did not consider the potential for common OMAs (i.e., the same or very similar OMAs used in multiple fire areas, or in the same fire areas, but in response to different fire initiators) to be risk significant. The team noted that the risk evaluation also needed to document the deviations from the fire protection SDP process. These deviations included: the basis for excluding some of the fixed combustible sources from the ignition frequencies; the cabinet counting method used in ignition frequency calculations; the comparison of BFNP conditional core damage probabilities (CCDPs) to the CCDPs based on the NRC SDP Notebook; and the conservatism of the use of a cable damage probability of 0.5 as a surrogate for the probability of non-suppression in the SDP. BFNP initiated PER 104418 for tracking of the incomplete risk assessment of the fire areas with Section III.G.2 OMAs.

c. Conclusions

The team determined that BFNP had performed a risk evaluation of the fire areas employing 10 CFR 50, Appendix R,Section III.G.2. post-fire OMAs outside the MCR to achieve SSD using the guidance of NRC IMC 0609, Appendix F. The risk evaluation was not complete as it did not address the risk contribution of transient combustible fires, the risk impact of potential fire induced spurious equipment operation, or consider the potential for common OMAs (i.e., the same or very similar OMAs used in multiple fire areas, or in the same area, but in response to different fire initiators) to be risk significant. The team determined that the risk evaluation also needed to document the deviations from the fire protection SDP process. PER 104418 was initiated for tracking of the incomplete risk assessment.

1.3 Review of the Feasibility of Post-Fire 10 CFR 50, Appendix R,Section III.G.2 Operator_Manual Actions (37550)

a. Inspection Scope

The team reviewed the BFNP feasibility and reliability of post-fire,Section III.G.2 OMAs in fire area/fire zones 1-1, 1-5, and 25. The inspection included a timed walkdown of all OMAs that were required to be completed in less than 25 minutes. The team also reviewed the licensees analytical basis for the required completion time for OMAs. The team examined MCR staffing for selected dates to ensure sufficient staff availability to implement SSD using the Safe Shut-down Instructions (SSIs). Documents reviewed are listed in the Attachment.

b. Observations and Findings

The team determined that BFNP had identified the post-fire SSD OMAs required to be performed outside the main control room in Section III.G.2 fire area/fire zones 1-1, 1-5, and 25. However, the licensee provided three different definitions of the starting time for these OMAs - at the entry into the procedure, when the reactor tripped, or when the procedural attachments were handed out. For the purposes of the NRC walkdown, the team started the clock for the OMAs from a location directly outside the main control room. The team noted that this start time will need to be adjusted for the analytically-based start time that TVA later determines to be correct. Regardless, using this starting time, the licensee was unable to demonstrate that all of these actions could be completed within the procedurally required times The team also found many labeling issues associated with OMAs. Additionally, the team identified several minor problems with the procedural instructions for OMAs.

c. Conclusions

Until TVA revises their procedural attachments, and provides and implements an analytically-based definition for the start time for OMAs, the team could not reach a conclusion on the feasibility and reliability of post-fire 10 CFR 50, Appendix R,Section III.G.2 OMAs in the selected fire area/fire zones. This is identified as URI 05000259/2006012-01, Feasibility and Reliability of Local Operator Manual Actions to Achieve Safe Shutdown. PER 104575 was initiated for tracking and resolution of this issue.

E1.4 Special Program Activities - Cable Installation and Cable Separation (37550 and 37551)

a. Inspection Scope

The programs for investigating and resolving the issues of cable installation and cable separation are described in TVAs letter to the NRC dated May 10, 1991. This letter describes programs as essentially the same as described in the Browns Ferry Nuclear Performance Plan which outlined the corrective actions to be implemented before restart of Unit 2, and repeated for restart of Unit 3. NRC IMC 2509, Browns Ferry Unit 1 Restart Project Inspection Program, endorses the licensee Special Programs utilized on Units 2 and 3 as sufficient to address corresponding issues on Unit 1, if implemented in the same manner. BFN-50-728, Physical Independence of Electrical Systems, was reviewed to verify design requirements for the physical and electrical separation of electrical equipment and circuits for those systems whose operation is essential to the safe shutdown and isolation of the reactor.

This inspection focused on the corrective actions that were being implemented by TVA to resolve the cable separations of concern for the Unit 1 Restart. This inspection included a review of BFN 50-728 and separation issues addressed in EDQ 0999-910078 External Cable Separation Analysis and EDQA 19992-003061, Internal Cable Separation

Analysis.

EDQ 0999-910078 primarily pertains to cables routed in cable raceways, conduits, and cable trays. EDQA 19992-003061 primarily pertains to separation issues related to cables and wires located within panels.

The inspection was conducted by reviewing work order records, design basis documents, corrective actions, exceptions, and drawings, and by conducting walkdown inspections of methods used for achieving divisional separation or functional redundancy for Unit 1. Documents reviewed are listed in the Attachment.

b.

Observations External Issues:

TVA identified instances where the electrical separation requirements have not been met at BFNP. These discrepancies were discovered while implementing design changes and conducting reviews as part of the BFNP Unit 2 restart effort and have been documented by the issuance of Licensee Event Report (LER) No. 05000259, 05000260, 05000296/1988-032-00, dated October 21, 1988, and subsequent Condition Adverse to Quality reports. During this inspection, selected Design Change Notices (DCN) related to Engineered Safeguards (ES), Core Spray (CS) and Residual Heat Removal (RHR)systems were reviewed. The inspectors also reviewed closure of PERs pertaining to cable separation for appropriate resolution.

The inspectors reviewed Design Criteria Document BFN-50-728, calculations, and walkdown reports of areas in the cable vault and tunnel, auxiliary instrument room, and MCR focusing on external cable separation. The inspectors reviewed criteria for spatial separation, functional redundancy, and other construction requirements to verify that as-built configurations were consistent with standards and requirements for cables, cable routes, and cable trays. The inspectors verified that field installations met divisional separation or functional redundancy separation, and maintained compliance with the single failure criteria in accordance with design criteria. The inspectors also verified that cables/circuits which did not meet divisional separation requirements, nor complied with functional redundancy separation, were appropriately dispositioned. This included a review of exceptions and any supporting information that formed the acceptance criteria for the exceptions. The exceptions reviewed were EX-BFN-728-33 and EX-BFN-50-728-37.

The inspectors also reviewed exception EX-BFN-50-728-34, which established the deviation for field installations of raceways, to verify if some cable trays that have less than the required thickness (as defined in BFN-50-728) were conservatively protected.

Cable trays affected by this deviation were primarily located in the MCR and auxiliary instrument room. The inspectors verified that design basis events had been considered and were conservatively accounted for in the justification for the deviation. The inspectors performed walkdowns of selected abandoned, rerouted, retagged, and newly pulled cables to verify that implementation was in accordance with the respective DCN.

The DCNs selected for the review were: 51211, 51216, and 51081.

Another aspect of the inspection focused on criteria for the top hat region of panels (1-PNLA-009-0015, 0017, 0042, 0043) in the auxiliary instrument room. The top hat region is an enclosed area, located in the upper region of the panels used for cable ingress and egress. The top hat region of panels and associated divisional and non-divisional

TVA cables were inspected and reviewed for compliance with the requirements of BFN-50-728. Requirements for cables in the top hat region are not clearly defined in BFN-50-728, but the licensee conservatively addressed the top hat region in the external separations section in BFN-50-728. The inspectors verified that the top hat region maintains compliance of raceway criteria as defined for the cable trays.

The inspectors performed additional walkdowns and sample checks via the Integrated Cable and Raceway Design System (ICRDS) to verify that no conditions existed which would allow cables from opposite divisions to violate spatial requirements in the top hat region. The cables reviewed for the external issues section of BFN-50-728 are listed in the Attachment.

Internal Issues:

BFNPs initial design for internal panel circuitry failed to observe divisional separation within panels. This was documented in response to Atomic Energy Commission questions and a functional redundancy evaluation performed during 1972-1973. The initial evaluation in 1972-1973 was for Unit 1 and reviewed approximately 42 panels or boards. Prior to Unit 1 restart, verification of the existing original installed equipment and a new baseline effort for internal panel separation was undertaken. The new baseline effort was documented in Electrical Calculation EDQ1999 19992-003061. The Unit 1 internal separation analysis reviewed approximately 106 panels or boards that contained redundant divisional intruder cables. Also, included in the evaluation were the Primary Containment Isolation Valve circuits.

The inspectors reviewed criteria for spatial separation, connection details, and other construction requirements to verify that as-built configurations were consistent with standards and requirements for wires, cable routing, and panels. The inspectors conducted walkdown inspections of panels 1-PNLA-009-0015, 1-PNLA-009-0017, 1-PNLA-009-0023, 1-PNLA-009-0032, 1-PNLA-009-0033, 1-PNLA-009-0042, and 1-PNLA-009-0043, to verify that the separation requirements in the as-found configuration were consistent with calculations, design criteria and drawings. The inspectors selected the referenced DCN packages to assess the adequacy of the licensees internal cable separations program. The cables reviewed for the internal issues section of BFN-50-728 are listed in the Attachment.

The inspector identified a violation of 10 CFR 50, Appendix B, Criterion III, Design Control for a failure to assure that the design change measures, for relocating Division II cables to a separate terminal block six inches from Division I cables in panel 1-PNLA-009-0023, were correctly translated into work instructions. This resulted in the as-built configuration for cables PL2817-II and PL2824-II deviating from design drawings. BFN-50-728 specifies, in part, that divisional separation for cables located within panels would be maintained by a minimum spatial separation of six inches. The cables, located in panel 1-PNLA-009-0023, Bay 8, in the MCR for the 480V Diesel Auxiliary Board B Division II cables were to be removed from the existing terminal block, routed in flexible conduit, and terminated onto a different terminal block located a minimum six inches from the Division I cables. The inspectors found that installed Division II cables PL2817-II and PL2824-II were not terminated onto a different terminal block six inches from Division I cables, PL2816-I and PL2823-I as illustrated on wiring drawings. The design change to relocate cables PL2817-II and PL2824-II was originally issued in DCN 51090, Stage 73, on 08/07/03. The licensee separated stage 73 into four separate stages in PIC No. 65340 to DCN 51090, consisting of stages 81, 82, 83, and 84. Stages 83 and 84 were issued on 11/02/05, and added design guidance for routing cable PL2817-II in flexible conduit and relocating the wires to a separate terminal block six inches from Division I cables. The licensee used PIC No. 65340, Work Orders (WO) 04-720414-52 and -53 to incorporate the changes on 03/06/06, for Stages 83 and 84 respectively.

The craft correctly implemented WO 04-720414-52 which reinstalled the cables in conduit. However, the craft did not correctly implement WO 04-720414-53, which relocated the cables onto a separate terminal block that was a minimum of six inches away from the Division I cables within panel 1-9-23 Bay 8. The licensee later closed DCN 51090, Stages 83 and 84, on 03/07/06, on the basis that the WO and PIC were completed. The inspectors identified cable PL2817-II for a walkdown review to verify that the as-found installation matched the drawings and documents of DCN 51090.

After the cables were identified for inspection by the NRC, the licensee performed a pre-walkdown of the cables and determined that the as-found installations were not consistent with the drawings. The licensee issued PER 101868 to document the finding.

The inspectors performed an independent walkdown to verify that the as-built configuration was not consistent with the as-constructed drawing Wiring Diagram 0-55N627-5. Subsequently, the licensee performed an extent of condition evaluation (PER 102752). This effort identified five similar discrepancies between as found installations and plant records.

10 CFR 50, Appendix B, Criterion III, Design Control, requires that measures be established to ensure that applicable regulatory requirements and the design basis are correctly translated into specifications, drawings, procedures, and instructions. Contrary to the above, on April 5, 2006, measures were not adequate to assure that the design changes (PIC 65340) for routing cables in flexible conduit and relocating the cables to a separate terminal block six inches from Division I cables were correctly translated into work instructions. As a result, DCN 51090, Stages 83 and 84, and PIC 65340 were incorrectly implemented and closed, and the as-constructed drawings issued, without the criteria for divisional separation being met. A Severity Level IV Violation was identified against the criteria in Supplement II, Facility Construction, of the NRC Enforcement Policy. This violation is being treated as an NCV, consistent with Section VI.A of the NRC Enforcement Policy, NCV 05000259/2006012-02, Measures Were Not Adequate to Assure that Cables for 480-V MOV Boards 1A and 1B in Panel 1-9-23 Bay 8 Were Separated. This issue was documented by the licensee in PER 101868.

c. Conclusions

A Severity Level IV NCV was identified for failure to comply with 10 CFR 50, Appendix B, Criterion III, in that, measures were not adequate to ensure that the design change output documents for relocating Division II cables to a separate terminal block six inches from Division I cables in Panel 1-9-23 Bay 8 were correctly translated into work instructions. This resulted in the as-built terminal block configuration of the plant deviating from design drawings. Based on the above violation, in addition to the small sample of completed activities in these areas, additional inspections will be required to determine if the Cable Separation Issues Special Program is being implemented satisfactorily.

Corrective Actions The inspectors performed walkdowns related to the following PERS: 102771 (Cable jacket damage and LB condulet) and 102329 (Cable installation on improper side).

The inspectors identified no significant examples in which the corrective action program has not been effective at identification and resolution of issues related to cable separation issues.

V. Management Meetings X1

Exit Meeting Summary

On May 12, 2006, the inspectors presented the cable installation and separation inspection results to Mr. Phil Gilbert and other members of his staff, who acknowledged the results presented.

On June 2, 2006, the lead inspector presented the remaining inspection results to Mr. M. Bajestani and other members of the BFNP and TVA staff, who acknowledged the findings.

The inspectors confirmed that proprietary information which was examined during the inspection was not retained and is not included in this inspection report.

SUPPLEMENTAL INFORMATION

KEY POINTS OF CONTACT

Licensee personnel

R. Abbas, BFNP Engineering
B. Aukland, BFNP Plant Manager U2/3
S. Austin, BFNP Site Licensing
M. Bajestani, BFNP U1 Vice President
M. Bali, Design Engineering, Bechtel
R. Baron, BFNP Nuclear Assurance Manager
D. Beckley, Design Engineer, Bechtel
M. Bennett, Quality Engineer, TVA
C. Boschetti, BFNP U2/3 Design Engineering Electrical / Instrumentation & Controls
J. Boykin, Quality Engineer, TVA
D. Burrell, BFNP, U1 Electrical Engineering Lead
J. Burton, BFNP U2/3 Design Engineering
P. Byron, BFNP U1 Licensing
R. Chadwell, BFNP Operations Superintendent
T. Elms, BFNP U2/3 Operations Manager
K. Groom, BFNP System Engineer / Mechanical Nuclear Design
E. Hayden Smith, BFNP Fire Operations
M. Heatherly, BFNP Corporate Engineering (CE) / Mechanical Nuclear / Fire Protection &

Appendix R

S. Kammer, BFNP U1 Engineering
D. Kehoe, BFNP Nuclear Assurance Supervisor
J. Kovach, Field Engineer, Bechtel
D. Langley, BFNP Site Licensing Supervisor
G. Little, BFNP Unit 1 Restart Manager
J. McCarthy, BFNP U1 Licensing Supervisor
J. McCrary, BFNP U1 Operations Support
R. Moll, BFNP U1 System Engineer Lead
N. Nelson, BFNP U1 Project Planning Manager
A. Robinson, BFNP CE / Mechanical Nuclear/ Probabilistic Safety Assessment
J. Schlessel, BFNP U1 Maintenance Supervisor
J. Valente, BFNP U1 Engineering Manager
J. Wallace, BFNP Site Licensing

NRC personnel

W. Bearden, Senior Resident Inspector, Unit 1
R. Bernhard, RII Senior Reactor Analyst
H. Christensen, Deputy Director, Division of Reactor Safety, Region II
E. Christnot, Resident Inspector, Unit 1
R. Gallucci, NRR Senior Fire Probabilistic Risk Assessment Engineer
A. Klein, NRR Senior Fire Protection Engineer
E. Lea, RII Acting Chief, Engineering Branch (EB) 2, Division of Reactor Safety (DRS)
G. MacDonald, RII Senior Reactor Inspector, EB 2
L. Mellen, RII Senior Project Engineer BFNP U1 Restart, Division of Reactor Projects (DRP)
P. Qualls, NRR Fire Protection Engineer
C. Stancil, BFNP Resident Inspector, Unit 1
S. Weerakkody, NRR Fire Protection Branch Chief
M. Widmann, RII Chief, Project Branch 6, DRP

N.Staples, RII, Reactor Inspector, EB2

INSPECTION PROCEDURES USED

IP 37550 Engineering

IP 92701 Followup

LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED

Opened

05000259/2006012-01 URI Feasibility and Reliability of Local Manual Operator Actions to Achieve Safe Shutdown (Section E1.3)
05000259/2006012-02 NCV Measures Were Not Adequate to Assure that Cables for 480-V MOV Boards 1A and 1B in Panel 1-9-23 Bay 8 Were Separated (Section E1.4)

Closed

05000259/2005016-01 URI Use of Local Manual Operator Actions to Achieve Safe Shutdown (Section E1.1)

LIST OF DOCUMENTS REVIEWED