IR 05000220/2015301
| ML15126A555 | |
| Person / Time | |
|---|---|
| Site: | Nine Mile Point (DPR-063) |
| Issue date: | 05/06/2015 |
| From: | Diane Jackson Operations Branch I |
| To: | Orphanos P Exelon Generation Co |
| Jackson D | |
| References | |
| ER 2015301 | |
| Download: ML15126A555 (10) | |
Text
May 6, 2015
SUBJECT:
NINE MILE POINT NUCLEAR STATION, UNIT 1 - NRC INITIAL
OPERATOR LICENSING EXAMINATION REPORT 05000220/2015301
Dear Mr. Orphanos:
March 12, 2015
SUBJECT:
NINE MILE POINT NUCLEAR STATION, UNIT 1 - NRC INITIAL
OPERATOR LICENSING EXAMINATION REPORT 05000220/2015301
Dear Mr. Orphanos:
On March 12, 2015, the U.S. Nuclear Regulatory Commission (NRC) completed an examination at Nine Mile Point Nuclear Station, Unit 1. The enclosed report documents the examination findings, which were discussed on April 28, 2015, with Mr. J. Gerber, Training Manager, and other members of your staff.
The examination included the evaluation of eight applicants for reactor operator licenses, nine applicants for instant senior operator licenses, and one applicant for an upgrade senior operator license. The written and operating examinations were developed using NUREG-1021,
"Operator Licensing Examination Standards for Power Reactors," Revision 9, Supplement 1.
The license examiners determined that all applicants satisfied the requirements of 10 CFR Part 55, and the appropriate licenses were issued on April 28, 2015.
No findings were identified during this examination.
In accordance with 10 CFR 2.390 of the NRC's "Rules of Practice," a copy of this letter and its enclosure will be available electronically for public inspection in the NRC Public Document Room or from the Publicly Available Records (PARS) component of NRCs document system Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams/web-based.html (the Public Electronic Reading Room).
Sincerely,
/RA/
Donald E. Jackson, Chief Operations Branch
Division of Reactor Safety
Distribution: See Next Page
DOCUMENT NAME: G:\\DRS\\Operations Branch\\FISH\\Exam 15-NMP1 Mar 2 (U01905)\\EXAM 2015 REPORT.docx ADAMS PKG: ML14238A301
ADAMS ACCESSION NO.: ML15126A555 SUNSI Review
Non-Sensitive Sensitive
Publicly Available Non-Publicly Available
OFFICE RI/DRS/OB RI/DRS/OB
NAME TFish DEJackson
DATE 05/5/15 05/6/15
OFFICIAL RECORD COPY cc w/encl: Distribution via ListServ
Docket No. 50-220 License No. DPR-63
Enclosure:
NRC Initial Operator Licensing Examination Report 05000220/2015301 w/Attachment: Supplemental Information Distribution w/encl: (via E-mail)
D. Dorman, RA (R1ORAMAIL Resource)
D. Lew, DRA (R1ORAMAIL Resource)
H. Nieh, DRP (R1DRPMAIL RESOURCE)
M. Scott, DRP (R1DRPMAIL RESOURCE)
R. Lorson, DRS (R1DRSMAIL RESOURCE)
J. Trapp, DRS (R1DRSMAIL RESOURCE)
D. Schroeder, DRP S. McCarver, (Actg) DRP A. Siwy, DRP K. Kolaczyk, DRP, SRI G. Stock, DRP, RI M. Paulus, DRP, AA K. MorganButler, RI OEDO RidsNrrPMNineMilePoint Resource RidsNrrDorlLpl1-1 Resource ROPReports Resource
i Enclosure EXAMINATION REPORT
U.S. NUCLEAR REGULATORY COMMISSION
REGION I
Docket:
50-220
License:
Report :
Licensee:
Exelon Generation Company, LLC
Facility:
Nine Mile Point, Unit 1
Location:
P.O. Box 63 Lycoming, NY 13093-0063
Dates:
March 2-10, 2015 (Operating Test Administration)
March 12, 2015 (Written Examination Administration)
March 19 and April 2, 2015 (Licensee Submitted Post Exam Package)
March 12-April 10, 2015 (NRC Examination Grading)
April 28, 2015 (Licenses Issued)
Examiners:
T. Fish, Chief Examiner, Operations Branch J. DAntonio, Sr. Operations Engineer B. Fuller, Sr. Operations Engineer C. Lally, Operations Engineer
Approved By:
Donald E. Jackson, Chief Operations Branch Division of Reactor Safety
ii Enclosure
SUMMARY OF FINDINGS
ER 05000220/2015301; March 2-10, 2015, and March 12, 2015; Nine Mile Point Nuclear
Station, Unit 1; Initial Operator Licensing Examination Report.
NRC examiners evaluated the competency of eight applicants for reactor operator licenses, nine applicants for instant senior operator licenses, and one applicant for an upgrade senior operator license at the Unit 1 facility. The facility licensee developed the examinations using NUREG-1021, "Operator Licensing Examination Standards for Power Reactors," Revision 9,
Supplement 1. The written examination was administered by the facility on March 12, 2015.
NRC examiners administered the operating tests on March 2-10, 2015. The license examiners determined that all applicants satisfied the requirements of 10 CFR Part 55, and the appropriate licenses have been issued.
No findings were identified.
REPORT DETAILS
OTHER ACTIVITIES (OA)
4OA5 Other Activities (Initial Operator License Examination)
.1 License Applications
a. Scope
The examiners reviewed all license applications submitted by the licensee to ensure the applications reflected that each applicant satisfied relevant license eligibility requirements. The applications were submitted on NRC Form 398, Personal Qualification Statement, and NRC Form 396, Certification of Medical Examination by Facility Licensee. The examiners also audited six of the license applications in detail to confirm that they accurately reflected the subject applicants qualifications. This audit focused on each applicants experience and on-the-job training, including control manipulations that provided significant reactivity changes.
b. Findings
No findings were identified.
.2 Operator Knowledge and Performance
a. Examination Scope
On March 12, 2015, the licensee proctored the administration of the written examinations to all applicants. The licensee staff graded the written examinations, analyzed the results, and presented their analysis to the NRC on March 19, 2015.
The NRC examination team administered the various portions of the operating examination to all applicants on March 2-10, 2015. The eight applicants for reactor operator licenses participated in at least two dynamic simulator scenarios, in a control room and facilities walkthrough test consisting of 11 system tasks, and an administrative test consisting of four administrative tasks. The nine applicants seeking an instant senior operator license participated in at least two dynamic simulator scenarios, a control room and facilities walkthrough test consisting of 10 system tasks, and an administrative test consisting of five administrative tasks. The applicant for an upgrade senior operator license participated in two dynamic simulator scenarios, a control room and facilities walkthrough test consisting of five system tasks, and an administrative test consisting of five administrative tasks.
b. Findings
All of the applicants passed all parts of the operating test and the written examination.
For the written examinations, the reactor operator applicants average score was 88.33 percent and ranged from 80.00 to 92.00 percent; the senior operator applicants average score was 89.60 percent and ranged from 83.00 to 92.00 percent. The text of the examination questions and the licensees examination analysis may be accessed in the ADAMS system under the accession numbers noted in Attachment 1. In accordance with current NRC policy, the release of this written examination in ADAMS to the public will be delayed for 2 years.
Chapter ES-403 and Form ES-403-1 of NUREG 1021 require the licensee to analyze the validity of any written examination questions that were missed by half or more of the applicants. The licensee conducted this performance analysis for nine questions that met this criterion and submitted the analysis to the chief examiner.
The licensee also submitted five post-examination questions comments on March 19, 2015, and provided additional information on April 2, 2015. The NRC reviewed the facilitys post-exam comment submittal package and accepted facility recommendations on all five questions. The answer key was changed accordingly. The text of the examination questions and the licensees post-examination comments with the NRC resolutions may be accessed in the ADAMS system under the accession numbers noted in the Attachment 1.
.3 Initial Licensing Examination Development
a. Examination Scope
The facility licensee developed the examinations in accordance with NUREG-1021, Revision 9, Supplement 1. All licensee facility training and operations staff involved in examination preparation and validation were listed on a security agreement. The facility licensee submitted both the written and operating examination outlines on December 12, 2014. The chief examiner reviewed the outlines against the requirements of NUREG-1021, and provided comments to the licensee. The facility licensee submitted the draft examination package on January 16, 2015. The chief examiner reviewed the draft examination package against the requirements of NUREG-1021, and provided comments to the licensee. The NRC conducted an onsite validation of the operating examinations and provided further comments during the week of February 2, 2015. The licensee satisfactorily completed comment resolution on February 24, 2015.
b. Findings
The NRC approved the initial examination outline and advised the licensee to proceed with examination development.
The examiners determined that the written and operating examinations initially submitted by the licensee were within the range of acceptability expected for a proposed examination.
No findings were identified.
.4 Simulation Facility Performance
a. Examination Scope
The examiners observed simulator performance with regard to plant fidelity during the examination validation and administration.
b. Findings
No findings were identified.
.5 Examination Security
a. Examination Scope
The examiners reviewed examination security for examination development and during both the onsite preparation week and examination administration week for compliance with NUREG-1021 requirements. Plans for simulator security and applicant control were reviewed and discussed with licensee personnel.
b. Findings
No findings were identified.
4OA6 Meetings, Including Exit
The chief examiner presented the examination results to Mr. J. Gerber, Training Manager, and other members of the licensee's management staff on April 28, 2015. The licensee acknowledged the findings presented.
The licensee did not identify any information or materials used during the examination as proprietary.
Supplemental Information A-1
SUPPLEMENTAL INFORMATION
KEY POINTS OF CONTACT
Licensee Personnel
- J. Gerber, Training Director
ITEMS OPENED, CLOSED, AND DISCUSSED
None