Jr

-

y

, f _ '- ~

We q3

~

.

,e W

liDV 0 51993

,

Docket No. 50-213 Mr. John Executive Vice President - Nuclear Connecticut Yankee Atomic Power Company P.O. Box 270 Hartford, Connecticut 06141-0270

Dear Mr. Opeka:

SUBJECT: NRC INSPECTION REPORT NO. 50-213/93-17 This letter transmits the report of the resident safety inspection conducted by Mr. W. Raymond of this office during the period August 29,1993, to October 2,1993, at

the Haddam Neck Plant, Haddam Neck, Connecticut. The report covers activities authorized

'

'

by NRC License No. DPR-61. This inspection was focused on issues important to public-health and safety. Preliminary findings were discussed with Mr. J. Stetz of your staff at the conclusion of the inspection.

During this report period, we found Haddam Neck was operated in a safe and conservative manner. Operators performed very well to control the plant in response to degraded equipment conditions. The decision by the shift supervisor in response to the inoperable post i

accident sample system (PASS) valve showed a high regard for containment integrity and safe plant operations. There was good coordination and communication between several

_

'

plant groups to correct the valve problem. The plant operators, in particular, did a good job

to keep good oversight of the operability determinations and troubleshooting efforts, and demonstrated good " ownership" of plant status and the repair of its components.~

,

We appreciate your cooperation.

Sincerely,

,

A. Randolph Blough, Chief Projects Branch No. 4 Division of Reactor Projects Enclosure: NRC Region I Inspection Report No. 50-213/93-17

-

T 9311160054 931105

.

!

PDR ADOCK 05000213

-

V(f) l G

PDR:

-

l

.

...

WOV 0 51993

-

.

Mr. John