U. S. NUCLEAR REGULATORY COMMISSION

REGION V

Report N /85-36 Docket N License No. DPR-13 Licensee:

Southern California Edison Company P. 0. Box 800, 2244 Walnut Grove Avenue Rosemead, California 91770 Facility Name:

San Onofre Unit 1 Location:

.

Region V Office Walnut Creek, California Conference conducted:

November 1, 1985 Prepared by:

P. nson, Chief Date Signed React rojects Section No. 3 Approved by:

---

___1 P. H. J huson, Chief Date Signed-Reac oProjects Section No. 3 Summary:

Enforcement Conference on November 1, 1985 (Report No. 85-36),

The following matters were discussed: NRC concerns regarding inoperability of the Unit 1 turbine driven auxiliary feedwater pump on September 19, 198.

Licensee corrective action.

NRC enforcement polic This enforcement conference involved a total of 10 hours1.157407e-4 days <br />0.00278 hours <br />1.653439e-5 weeks <br />3.805e-6 months <br /> by eight NRC representative PDR ADOCK 05000206 PDR

ENFORCEMENT CONFERENCE Conference Attendees Southern California Edison Company (SCE)

H. B. Ray, Vice President, Site Manager K. P. Baskin, Vice President, Nuclear Engineering Safety and Licensing H. E. Morgan, Station Manager J. M. Curran, Quality Assurance Manager M. Wharton, Deputy Station Manager D. E. Schull, Maintenance Manager NRC Region V J. B. Martin, Regional Administrator B. H. Faulkenberry, Deputy Regional Administrator A. D. Johnson, Enforcement Officer A. E. Chaffee, Chief, Reactor Projects Branch P. H. Johnson, Chief, Reactor Projects Sectio F. R. Huey, Senior Resident Inspector, San ;Onofre P. P. Narbut, Project Inspector G. N. Cook, Public Affairs Officer Conference Summary The enforcement conference convened at

45p.m in the Region V conference room. Mr. Martin made opening remarks and discussed the purpose of the conferenc Mr. Huey then discussed the findings of the special inspection,.

involving failure of the-Unit: i turbine driven auxiliary feedwater pump following a reactor trip on September 19, 1985. Specific concerns were discussed, as identified in NRC Inspection Report No. 50-206/85-33. Apparent violations of NRC requirements were identifie Mr. Chaffee discussed NRC concerns related to the event and apparant causal factors as perceived based upon the NRC's inspection activities. The concerns addressed included the following:

o The licensee -missed a number of opportunities to identify and correct the inoperability of the auxiliary feedwater pum o-The modification made to the lubricating oil sight glass on the auxiliary feedwater pump was improper and was performed by a member of maintenance supervision without required authorization or documentatio Licensee procedures for documentation and correction of deficiencies were not followe Mr.. Ray then discussed corrective actions taken and being taken by SCE to address the identified weaknesses. This included an "Area Monitoring Program" which utilizes teams of Operations, technical, and maintenance supervisors t provide increased surveillance of safety related activities, and an "Enhanced Material Standard" to heighten awareness and increase sensitivity to the importance of individual system problems. Mr. Ray also stated that SCE would like to provide a written response to the special inspection report to further define actions being implemente In response to a question from Mr. A. Johnson, licensee representatives stated that.they had no questions regarding the NRC enforcement policy (as provided in 10 CFR 2, Appendix C).

Mr. Martin presented concluding remarks, and the conference adjoined at 2:55 p.m.