IR 05000029/1988001

From kanterella
Jump to navigation Jump to search
Forwards Safety Insp Rept 50-029/88-01 on 880120-0222.No Violations Noted.Concerns Identified Re Licensee Performance in Area of Dedicating Commercial Grade Components for Use in safety-related Sys
ML20150C499
Person / Time
Site: Yankee Rowe
Issue date: 03/15/1988
From: Wiggins J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Drawbridge B
YANKEE ATOMIC ELECTRIC CO.
Shared Package
ML20150C502 List:
References
NUDOCS 8803210017
Download: ML20150C499 (2)


Text

. _ - _.

s

.

%..

.

.

MAR 151988 Docket No. 50-29 Yankee Atomic Electric Company ATTN: Mr. Bruce L. Drawbridge Vice President and Manager of Operations-1671 Worcester Road Framingham, Massachusetts 01701 Gentlemen:

Subject:

Region I Inspection Report No. 50-29/88-01'

This refers to the routine resident safety inspection conducted by Mr. H. Eichenholz and Mrs. C. Carpenter of this. office on January 20 -

February 22,1988 at the Yankee Nuclear Power Station, Rowe, Massachusetts.

The inspection consisted of observation of activities, interviews with person-

-

nel, independent measurements and document reviews. The results of the inspec-tion are described in the NRC Region 1 inspection report enclosed with this letter and were discussed with Mr. N. St. Laurent of your staff at the. con-clusion of the inspection.

P Please note that the enclosed inspection report describes inspector concerns regarding observations of licensee performance in the area of dedicating commercial grade componer.ts for use in a safety-related system.

Similar NRC concerns in this area were. identified during the team inspection conducted'on January 10-15, 1988, as documented in Inspection Report No. 50-29/88-02. These observations warrant additional management attention.

Within the scope of this inspection, no violations were observed.

i Your cooperation with us is appreciated.

Sincerely, S'tnalBifMdD g

James T. Wiggins, Chief Reactor Projects Branch No. 3 Division of Reactor Projects Enclosure:

NRC Region I Inspection Report No. 50-29/88-01 l

g 0FFICIAL RECORD COPY IR YR 88-01 - 0001.0.0 g(

03/14/88 8803210017 880315

'E

/.

PDR ADOCK 05000029 C6

/

'

DCD g

-.

..

. - - - - - -..., - -..

.. - -

...-.

.... - -...

- -,,

- - _ - - - - _ -, -

.

.

s

.."

.-

,

.

Yankee Atomic Electric Company

  • MAR 15.1988 cc w/ encl:

J. E. Tribble, President N. N. St. Laurent, Plant Superintendent G. J. Papanic, Jr., Senior Project Engineer - Licensing P. W. Agnes, Assistant Secretary of Public Safety, Commonwealth of Massachusetts Public Document Room (PDR)

local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector Commonwealth of Massachusetts bec w/ encl:

Region I Docket Room (with concurrences)

M. Perkins, Management Assistant, DRMA (w/o encl)

D. Haverkamp, Section Chief, DRP-J. Kaucher, Project Engineer, DRP H. Eichenholz. '2RI - Yankee (w/ concurrences)

G. Grant, SRI - Vermont Yankee R. Bores, Technical Assistant, DRSS M. Fairtile, PM, NRR R. Summers, Project Engineer, DRP (See Section 12)

>

RI:DRP

DRP I:DRP

, g holz/mjd Dp mp JWiggins 3////88 3////88 3/h/88 0FFICIAL RECORD COPY IR YR 88-01 - 0002.0.0 03/14/88