IR 015000012/2025004

From kanterella
Jump to navigation Jump to search
Medical Outsourcing Solutions, NRC Forms 591M, and 592M, Inspection Report 15000012/2025004(DRSS)
ML25322A266
Person / Time
Site: 15000012, 015000012
Issue date: 11/14/2025
From: Ryan Craffey
NRC/RGN-III/DRSS/MIB
To: Skelton J
Medical Outsourcing Solutions
References
IR 2025004
Download: ML25322A266 (1)


Text

NRC FORM 591M (09-11-2024)

Materials Inspection Report U.S. NUCLEAR REGULATORY COMMISSION Page 1 of 1

Add Continuation Page Licensee/Location Inspected:

Medical Outsourcing Solutions 1735 DeKalb Avenue Sycamore, IL 60178 Location Inspected: Job site in Munster, IN Report Number(s) 2025-004 NRC/Regional Office Region III U. S. Nuclear Regulatory Commission 2056 Westings Avenue, Suite 400 Naperville, IL 60563-2657 Docket Number(s)

150-00012 License Number(s)

GL per 10 CFR 150.20 / IL-02186-01 Date(s) of Inspection September 26, 2025 LICENSEE:

The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows: Based on the inspection findings, no violations were identifie. Previous violation(s) closed. During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements, and were assessed at Severity Level IV, in accordance with the NRC Enforcement Policy. The following violation(s) is/are being cited in accordance with NRC Enforcement Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance with 10 CFR 19.1 (Violations and Corrective Actions)

Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identifie This statement of corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requested. The violation(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-identified, non-repetitive, corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy were satisfie (Non-cited violation(s) was/were discussed involving the following requirement(s)

TITLE NRC INSPECTOR PRINTED NAME SIGNATURE AND DATE LICENSEE'S REPRESENTATIVE (not required)

Ryan Craffey BRANCH CHIEF Rhex Edwards Digitally signed by RYAN CRAFFEY Date: 2025.11.14 13:03:12 -06'00'

Digitally signed by RHEX EDWARDS Date: 2025.11.14 14:10:04 -06'00'

NRC FORM 592M (10-04-2022)

U.S. NUCLEAR REGULATORY COMMISSION Materials Inspection Record Page 1 of 2 NRC Form 592M (10-04-2022) Licensee Name:

Medical Outsourcing Solutions Docket Number(s):

150-00012 License Number(s)

IL-02186-01 Report Number(s):

2025-004 Date(s) of Inspection:

September 26, 2025 Inspector(s):

Ryan Craffey Program Code(s):

02220 Priority:

3 Inspection Guidance Used:

IP 87130 1 Licensee Contact Name(s):

Jake Skelton - ARSO 1 Licensee E-mail Address:

jskelton@micmos.com 1 Licensee Telephone Number(s):

815-895-4381 1 Inspection Type:

Initial Routine Announced Non-Routine

Unannounced

1 Locations Inspected:

Hybrid Main Office Field Office Temporary Job Site

Remote 1 Next Inspection Date (MM/DD/YYYY):

TBD Normal Reduced Extended No change

1 Location(s) Inspected List:

Cardiovascular Consultants P.C. - 1730 45th Street, Munster, IN 1 Scope and Observations:

Medical Outsourcing Solutions, a medical services provider, was authorized by the State of Illinois to possess and administer diagnostic radiopharmaceuticals at numerous client locations across Illinois and at temporary job sites in State jurisdiction. The company performed work at temporary job sites in NRC jurisdiction per a reciprocity filing submitted in December 2024 for calendar year 2025. The scope of this inspection was limited to an evaluation of licensed activities (cardiac stress tests) at a client cardiology clinic in Munster, Indian The inspector visited the client's facility in Munster. Licensee staff adequately posted all areas of use, and maintained control and constant surveillance throughout the inspection. Independent surveys found no evidence of residual contamination, nor any ambient exposure readings above limits to the public in unrestricted areas. The inspector observed the preparation and administration of several diagnostic administrations of radiopharmaceuticals, which had been received by the licensee at its facility in Villa Park, Illinois, and transported by licensee staff to Munster. The inspector also observed functional checks of the licensee's survey instruments (a GM probe for exposure readings and an NaI probe for contamination). These were calibrated, operable, and appropriate for necessary survey tasks. Licensee staff were knowledgeable of radiation protection principles, wore personnel dosimetry as assigned, and utilized adequate ALARA practices to optimize occupational exposure The inspector also reviewed a selection of operational records, including diagnostic dose administration records, approved dose chart, instrument calibration and evaluation records, area survey results, package receipt results, shipping papers, and signed client agreemen No violations of NRC requirement were identified as a result of this inspectio Issuance of this report was delayed by the federal government shutdown from October 1 through November 12, 202 NRC FORM 592M (10-04-2022)

U.S. NUCLEAR REGULATORY COMMISSION Materials Inspection Record (Continued)

Page 2 of 2 NRC Form 592M (10-04-2022)

Signature and Date - Branch Chief Digitally signed by RHEX EDWARDS Date: 2025.11.14 14:09:29 -06'00'