ENS 57407
ENS Event | |
|---|---|
21:30 Oct 29, 2024 | |
| Title | Offsite Notification |
| Event Description | The following information was provided by the licensee via phone and email:
At 1730 [EDT], on 10/29/2024, Vistra authorized a report to the State of Ohio in accordance with NEI 07-07, 'Industry Groundwater Protection Initiative,' of a liquid spill to the plant's outdoor ground from an outdoor cask holding radioactive waste. This spill contained radionuclides cobalt-60 and manganese-54 with activities greater than the site procedural limits for state reporting. The outdoor cask has been removed from the onsite storage area; remediation and causal investigation activities are being performed. This exceedance did not exceed any NRC regulations or reporting criteria. There was no impact on the health and safety of the public or plant personnel. This notification is being made solely as a four-hour, non-emergency notification for a Notification of Other Government Agency. This event is reportable in accordance with 10 CFR 50.72(b)(2)(xi). The NRC Resident Inspector has been notified. The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance: No EPA limits were exceeded |
| Where | |
|---|---|
| Perry Ohio (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release | |
| Time - Person (Reporting Time:+-3.38 h-0.141 days <br />-0.0201 weeks <br />-0.00463 months <br />) | |
| Opened: | Robert Heil 18:07 Oct 29, 2024 |
| NRC Officer: | Rodney Clagg |
| Last Updated: | Oct 29, 2024 |
| 57407 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 574072024-10-29T21:30:00029 October 2024 21:30:00
[Table view]10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 572382024-07-24T14:46:00024 July 2024 14:46:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 569142024-01-05T20:52:0005 January 2024 20:52:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 565882023-06-23T19:21:00023 June 2023 19:21:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Environmental ENS 511982015-07-02T12:30:0002 July 2015 12:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Emergency Siren Actuation ENS 507182015-01-06T21:30:0006 January 2015 21:30:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Notification Made to Offsite Government Agency ENS 499872014-04-02T18:01:0002 April 2014 18:01:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Toxic Gas Release ENS 497462014-01-21T06:40:00021 January 2014 06:40:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Tritium Discovered in Groundwater ENS 487692013-02-19T18:03:00019 February 2013 18:03:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xii), Transport of a Contaminated Person Offsite Transport of Potentially Contaminated Worker and Subsequent Fatality ENS 480692012-07-03T21:38:0003 July 2012 21:38:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Emergency Siren Actuation ENS 479022012-05-07T16:33:0007 May 2012 16:33:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Emergency Siren Actuation ENS 479012012-05-06T13:35:0006 May 2012 13:35:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Made for Npdes Noncompliance ENS 473662011-10-21T21:20:00021 October 2011 21:20:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Fuel Oil Spill ENS 468032011-04-29T15:00:00029 April 2011 15:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Fatality of a Contract Employee ENS 463742010-10-28T21:51:00028 October 2010 21:51:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Sodium Hypochlorite Leak from Underground Piping ENS 457982010-03-28T04:00:00028 March 2010 04:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Press Release Due to Lube Oil Fire Affecting Reactor Feed Pump ENS 454232009-10-09T19:44:0009 October 2009 19:44:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to a Spill of Hydraulic Fluid ENS 441112008-03-31T19:50:00031 March 2008 19:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to Ohio Epa Concerning Non-Compliance with Hazardous Waste Removal Requirements ENS 436532007-09-19T19:25:00019 September 2007 19:25:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Unknown Discharge and 24 Hour Report Per Appendix B of Operating License ENS 432822007-04-05T04:00:0005 April 2007 04:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xii), Transport of a Contaminated Person Offsite Potentially Contaminated Person with a Back Injury Transported to Lake East Hospital ENS 426932006-07-08T13:18:0008 July 2006 13:18:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Exceeded Limit for Suspended Solids in Discharge ENS 426772006-06-30T19:18:00030 June 2006 19:18:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Non-Credible Security Threat Made Against Plant ENS 424762006-04-05T16:00:0005 April 2006 16:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to State and Local Officials Concerning Tritium Detection in Drain System ENS 423302006-02-11T20:15:00011 February 2006 20:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Alert Declared Due to a Fire in a Ventilation Fan ENS 423292006-02-10T18:45:00010 February 2006 18:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification 2024-07-24T14:46:00 | |