ENS 49987
ENS Event | |
---|---|
18:01 Apr 2, 2014 | |
Title | Unusual Event Declared Due to Toxic Gas Release |
Event Description | Release of toxic or flammable gas affecting the Protected Area boundary deemed detrimental to the safe operation of the plant.
Emergency Action Level entered: MU-1. The leak is Trichloroethylene (TCE) gas used in the Off-Gas building. The Off-Gas building ground and basement levels were evacuated due to the leak. There is no safe-shutdown equipment located in the Off-Gas building. The licensee is working to isolate the leak. The licensee informed the NRC Resident Inspector. The licensee notified the State of Ohio and the local counties. Notified DHS SWO, FEMA Ops Center, NICC Watch Officer, DOE Ops Center, USDA Ops Center, HHS Ops Center, and Nuclear SSA via email.
The licensee notified the following outside agencies: U.S. EPA National Response Center, Ohio EPA, Perry Township Fire Department, Lake County Emergency Planning Committee, and the U.S. Coast Guard. Notified R3DO (Passehl).
Unusual Event has been terminated on 4/5/2014 at 0059 EDT. The trichloroethylene leak has been stopped. Access has been restored to all normally accessible areas. Unit 1 remains in Mode 1 at 100% power. The licensee notified the NRC Resident Inspector and the Local and State emergency agencies. Notified the IRD MOC (Gott), R3DO (Passehl), and NRR EO (McGinty). Notified DHS SWO, DOE Ops Center, FEMA Ops Center, HHS Ops Center, NICC Watch Officer, USDA OPS Center, EPA EOC, FDA EOC, and Nuclear SSA via email. |
Where | |
---|---|
Perry ![]() Ohio (NRC Region 3) | |
Reporting | |
Emergency class: | Unusual Event |
10 CFR 50.72(a) (1) (i), Emergency Class Declaration 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release | |
Time - Person (Reporting Time:+-3.32 h-0.138 days <br />-0.0198 weeks <br />-0.00455 months <br />) | |
Opened: | Don Rogers 14:42 Apr 2, 2014 |
NRC Officer: | Jeff Rotton |
Last Updated: | Apr 5, 2014 |
49987 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 49987\u003C/a\u003E - \u003Ca href=\"/Perry\" title=\"Perry\"\u003EPerry\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EUnusual Event Declared Due to Toxic Gas Release\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 49987 - Perry\n","link":"","lat":41.79572777777778,"lon":-81.145375,"icon":"/w/images/a/ad/FirstEnergy_icon.png"}],"imageoverlays":null} | |
Unit 1 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
Perry ![]() | |
WEEKMONTHYEARENS 569142024-01-05T20:52:0005 January 2024 20:52:00
[Table view]10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 565882023-06-23T19:21:00023 June 2023 19:21:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Environmental ENS 511982015-07-02T12:30:0002 July 2015 12:30:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Emergency Siren Actuation ENS 507182015-01-06T21:30:0006 January 2015 21:30:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Notification Made to Offsite Government Agency ENS 499872014-04-02T18:01:0002 April 2014 18:01:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Toxic Gas Release ENS 497462014-01-21T06:40:00021 January 2014 06:40:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Tritium Discovered in Groundwater ENS 487692013-02-19T18:03:00019 February 2013 18:03:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xii), Transport of a Contaminated Person Offsite Transport of Potentially Contaminated Worker and Subsequent Fatality ENS 485422012-11-28T15:19:00028 November 2012 15:19:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Notification of Unusual Event Due to Toxic Gas in Radwaste Control Room ENS 480692012-07-03T21:38:0003 July 2012 21:38:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Emergency Siren Actuation ENS 479022012-05-07T16:33:0007 May 2012 16:33:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Inadvertent Emergency Siren Actuation ENS 479012012-05-06T13:35:0006 May 2012 13:35:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Made for Npdes Noncompliance ENS 473662011-10-21T21:20:00021 October 2011 21:20:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Fuel Oil Spill ENS 468032011-04-29T15:00:00029 April 2011 15:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Fatality of a Contract Employee ENS 463742010-10-28T21:51:00028 October 2010 21:51:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to Sodium Hypochlorite Leak from Underground Piping ENS 457982010-03-28T04:00:00028 March 2010 04:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Press Release Due to Lube Oil Fire Affecting Reactor Feed Pump ENS 454232009-10-09T19:44:0009 October 2009 19:44:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification Due to a Spill of Hydraulic Fluid ENS 441112008-03-31T19:50:00031 March 2008 19:50:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to Ohio Epa Concerning Non-Compliance with Hazardous Waste Removal Requirements ENS 436532007-09-19T19:25:00019 September 2007 19:25:00 Other Unspec Reqmnt, 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification of Unknown Discharge and 24 Hour Report Per Appendix B of Operating License ENS 432822007-04-05T04:00:0005 April 2007 04:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(b)(3)(xii), Transport of a Contaminated Person Offsite Potentially Contaminated Person with a Back Injury Transported to Lake East Hospital ENS 426932006-07-08T13:18:0008 July 2006 13:18:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification - Exceeded Limit for Suspended Solids in Discharge ENS 426772006-06-30T19:18:00030 June 2006 19:18:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Non-Credible Security Threat Made Against Plant ENS 426562006-06-20T20:30:00020 June 2006 20:30:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to a Seismic Event ENS 424762006-04-05T16:00:0005 April 2006 16:00:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification to State and Local Officials Concerning Tritium Detection in Drain System ENS 423302006-02-11T20:15:00011 February 2006 20:15:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release, 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Alert Declared Due to a Fire in a Ventilation Fan ENS 423292006-02-10T18:45:00010 February 2006 18:45:00 10 CFR 50.72(b)(2)(xi), Notification to Government Agency or News Release Offsite Notification ENS 411952004-11-12T20:00:00012 November 2004 20:00:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event ENS 411732004-11-04T15:54:0004 November 2004 15:54:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to a Toxic Gas Release Affecting Normal Operations ENS 408822004-07-20T07:44:00020 July 2004 07:44:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Alert Declared Due to High Offgas Effluent Alarm Pegged High and Unable to Confirm within 15 Minutes ENS 400632003-08-14T20:10:00014 August 2003 20:10:00 10 CFR 50.72(a)(1)(i), Emergency Class Declaration Unusual Event Declared Due to Loss of Offsite Power Greater than 15 Minutes. 2024-01-05T20:52:00 | |