The following information was provided by the licensee via e-mail:
NFS [Nuclear Fuel Services, Inc.] evaluated a degraded Item Relied On For Safety (IROFS) in accordance with the documented Integrated Safety Analysis. During this review, the event was determined to be NON-REPORTABLE as additional controls were available and performance criteria maintained. However, during the detailed review of past performance, when the IROFS that was available in this scenario failed, the redundant IROFS would have been degraded.
There were no actual radiological or other nuclear safety consequences to the public, workers, or the environment.
The Senior Resident Inspector and Region II staff were notified.
The following additional information was obtained from the licensee in accordance with Headquarters Operations Officers Report Guidance:
The plant was shutdown pending repair or implementation of compensating measures.