WEEKMONTHYEARENS 578802025-08-20T15:20:00020 August 2025 15:20:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Inoperable Containment Unit Coolers ENS 572522024-06-07T06:46:0007 June 2024 06:46:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Control Room Envelope Failed Surveillance ENS 561162022-09-19T06:32:00019 September 2022 06:32:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Safety System Inoperability ENS 548802020-09-04T01:48:0004 September 2020 01:48:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray Inoperable ENS 544702020-01-09T17:32:0009 January 2020 17:32:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor Loss of Chillers ENS 543482019-10-24T15:35:00024 October 2019 15:35:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Automatic Depressurization System Inoperable ENS 543382019-10-18T07:07:00018 October 2019 07:07:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident En Revision Imported Date 11/20/2019 ENS 536222018-09-25T05:00:00025 September 2018 05:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Control Building Chillers in Unanalyzed Condition ENS 533822018-05-04T16:29:0004 May 2018 16:29:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.72(b)(3)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Associated with Damaging Effects of Tornados ENS 533652018-04-26T20:31:00026 April 2018 20:31:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(2)(iv)(A), System Actuation - ECCS Discharge Inadvertent Injection of High Pressure Core Spray ENS 533242018-04-11T06:50:00011 April 2018 06:50:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Condition That Could Impair Function of Control Building Ac System ENS 529952017-09-27T15:00:00027 September 2017 15:00:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Accident Mitigation - Loss of Secondary Containment ENS 526312017-03-23T07:56:00023 March 2017 07:56:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray Declared Inoperable ENS 518992016-05-03T03:29:0003 May 2016 03:29:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray System Inoperable Due to a Control Room Chiller Trip ENS 517542016-02-24T17:00:00024 February 2016 17:00:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor Electrical Breaker Issue Identified During an Engineering Review ENS 516002015-12-11T10:16:00011 December 2015 10:16:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray Declared Inoperable ENS 515522015-11-19T13:24:00019 November 2015 13:24:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray Declared Inoperable ENS 515452015-11-18T05:55:00018 November 2015 05:55:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray Declared Inoperable ENS 510832015-05-21T08:09:00021 May 2015 08:09:00 10 CFR 50.72(b)(3)(v)(A), Loss of Safety Function - Shutdown the Reactor Dc Electrical Room Heat Load Calculations Not Updated After New Inverters Installed ENS 510282015-05-01T04:44:0001 May 2015 04:44:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray System Inoperable ENS 503372014-08-02T02:42:0002 August 2014 02:42:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray Declared Inoperable Due to Test Return Valve Leakage ENS 493622013-09-19T19:37:00019 September 2013 19:37:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Secondary Containment Inoperable Due to an Unattended Open Door ENS 463992010-11-07T15:23:0007 November 2010 15:23:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident High Pressure Core Spray Pump Oil Leak ENS 460482010-06-26T01:24:00026 June 2010 01:24:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Hpcs Inoperable ENS 451192009-06-09T23:52:0009 June 2009 23:52:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Door for Secondary Containment Boundary Left Open ENS 429212006-10-19T22:56:00019 October 2006 22:56:00 10 CFR 50.72(b)(2)(iv)(B), RPS System Actuation, 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(iv)(A), System Actuation, 10 CFR 50.72(b)(2)(iv)(A), System Actuation - ECCS Discharge Automatic Scram Following Spontaneous Feedwater Valve Closure ENS 422852006-01-25T01:32:00025 January 2006 01:32:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident Invalid High Pressure Core Spray (Hpcs) Initiation Signal During Surveillance Testing 2025-08-20T15:20:00
[Table view] |