ENS 52484
ENS Event | |
|---|---|
21:00 Jan 11, 2017 | |
| Title | Teflon Found in Containment Spray Pump Components |
| Event Description | On September 16, 2016, Comanche Peak reported an unanalyzed condition and potential loss of safety function per 10 CFR 50.72(b)(3)(ii)(B) and 10 CFR 50.72(b)(3)(v) related to Teflon (PTFE) installed in the pressure gauge diaphragm seal assemblies for all four of the Centrifugal Charging Pumps and both of the Positive Displacement Charging Pumps on Units 1 and 2 (EN#52244). On November 14, 2016, this event was subsequently retracted.
On December 12, 2016, during the ongoing extent of condition review, Teflon was also found to be installed in the suction and discharge pressure gauge diaphragm seal assemblies for the Unit 1 and 2 Containment Spray Pumps. On January 11, 2017 at approximately 1500 CDT, the reportability evaluation determined that reasonable assurance did not exist that the Containment Spray system would have been able to fulfill its design function of removing heat from the containment environment without impacting the applicable dose limits. Teflon (PTFE) is a restricted material normally prohibited from use in contact with reactor coolant or in radiation environments. Teflon (PTFE) is not radiation tolerant and degrades in a radiation environment. The Teflon (PTFE) used in these diaphragm seal assemblies could fail during a postulated Loss of Coolant Accident (LOCA) which could cause the Containment Spray Pumps on Units 1 and 2 to be inoperable, and exceed system leakage limits. This could challenge dose limits and in plant post-accident accessibility. This represents an unanalyzed condition. The pressure gauges and diaphragm seals for all of the Unit 1 and 2 Containment Spray Pumps have been isolated and the Unit 1 and 2 Containment Spray Pumps are operable. The Teflon (PTFE) has likely existed in these diaphragm seals since initial plant licensing. Luminant Power is continuing to investigate the extent of this condition and potential repair techniques. The NRC Resident Inspector has been notified. |
| Where | |
|---|---|
| Comanche Peak Texas (NRC Region 4) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition | |
| Time - Person (Reporting Time:+-4.07 h-0.17 days <br />-0.0242 weeks <br />-0.00558 months <br />) | |
| Opened: | Hunter Schill 16:56 Jan 11, 2017 |
| NRC Officer: | Donald Norwood |
| Last Updated: | Jan 11, 2017 |
| 52484 - NRC Website
Loading map... | |
Unit 1 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
Unit 2 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |
WEEKMONTHYEARENS 528172017-06-21T15:00:00021 June 2017 15:00:00
[Table view]10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Postulated Fire Event Could Adversely Impact Safe Shutdown Equipment ENS 526462017-03-29T00:57:00029 March 2017 00:57:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition for a Postulated Moderate Energy Line Break ENS 524842017-01-11T21:00:00011 January 2017 21:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Teflon Found in Containment Spray Pump Components ENS 522442016-09-15T20:40:00015 September 2016 20:40:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Potential Degradation of Eccs Pump Pressure Indicators ENS 522392016-09-13T22:30:00013 September 2016 22:30:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Involving Station Service Water Trains ENS 522172016-09-01T15:25:0001 September 2016 15:25:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition on Turbine Driven Auxiliary Feedwater Pump ENS 517512016-02-23T23:00:00023 February 2016 23:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Involving Normally Open Battery Room Doors ENS 508352015-02-19T22:00:00019 February 2015 22:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Involving Normally Closed Watertight Doors ENS 500432014-04-18T17:52:00018 April 2014 17:52:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Cable Routing Unanalyzed for Fire Safe Shutdown Barrier ENS 494192013-10-08T17:40:0008 October 2013 17:40:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Postulated Hot Short Fire Event That Could Adversely Impact Safe Shutdown Equipment ENS 477132012-03-01T23:05:0001 March 2012 23:05:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Battery Room Ventilation System Degraded ENS 473572011-10-20T01:02:00020 October 2011 01:02:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Due to Pressure Instruments Containing Aluminum Material ENS 473522011-10-18T20:45:00018 October 2011 20:45:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Aluminum Valve Discovered Installed in Containment ENS 470862011-07-21T16:53:00021 July 2011 16:53:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Vulnerability from a Potential Control Room Fire on "a" Safeguards Bus ENS 435622007-08-13T14:00:00013 August 2007 14:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Inadequate Fire Protection on Safety Chilled Water System Electrical Cables 2017-06-21T15:00:00 | |