ENS 52217
ENS Event | |
---|---|
15:25 Sep 1, 2016 | |
Title | Unanalyzed Condition on Turbine Driven Auxiliary Feedwater Pump |
Event Description | During a review of ongoing analyses related to postulated tornado missiles, a question was raised about the sentinel valve on the turbine driven auxiliary feedwater pump (TDAFW). The sentinel valve is designed as a warning system on steam equipment to warn personnel of increased back pressure. The valve is not an ASME component and its operation is not required to support TDAFW operation.
The draft analysis predicts the TDAFW exhaust stack could be partially crimped by a tornado missile and the resultant back pressure on the turbine would increase to approximately 40 psi. This is higher than the set point for the sentinel valve (nominally 27 and 29 psi for Units 1 and 2, respectively). Therefore, in a design basis tornado with a design basis tornado missile striking the TDAFW exhaust stack, and in a condition where the TDAFW is demanded to run, the sentinel valve is expected to lift and allow steam to flow into the room. Vendor correspondence indicates that at approximately 40 psi the sentinel valve will conservatively pass 600 lbm/hr. Thus, it is conservatively considered operation of the TDAFW under such conditions would create an adverse steam environment which would be beyond that which the TDAFW pump has been analyzed to operate. Actions planned to alleviate the above condition would eliminate the potential for adverse environmental conditions. The steam supplies to the TDAFW have been isolated to affect repairs, which are expected to be limited to removal of the sentinel valve from each Unit and installation of a plug. Said activities are expected to be completed within the Allowed Out-of-Service Time (AOT) of the TDAFW of seventy-two hours per Technical Specification 3.7.5. NRC Resident Inspector has been informed.
On 09/01/2016 Comanche Peak reported an ENS Report (no. 52217) related to unanalyzed conditions related to the sentinel valve on the turbine driven auxiliary feedwater pump (TDAFW) during postulated tornado-based scenarios and non-tornado based scenarios. The technical concern was the potential for the sentinel valve to release steam into the TDAFW room and result in adverse environmental conditions within the room and potentially external to the TDAFW room for both tornado-based and non-tornado based scenarios. Subsequent investigations by Engineering have determined the sentinel valve would not be demanded to open during tornado based scenarios and would not result in adverse environmental conditions internal or external to the TDAFW room in any design bases scenario. The licensee has notified the NRC Resident Inspector. Notified the R4DO (Farnholtz). |
Where | |
---|---|
Comanche Peak ![]() Texas (NRC Region 4) | |
Reporting | |
10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition | |
Time - Person (Reporting Time:+3.23 h0.135 days <br />0.0192 weeks <br />0.00442 months <br />) | |
Opened: | John Alexander 18:39 Sep 1, 2016 |
NRC Officer: | Steven Vitto |
Last Updated: | Oct 27, 2016 |
52217 - NRC Website
Loading map... {"minzoom":false,"maxzoom":false,"mappingservice":"leaflet","width":"350px","height":"250px","centre":false,"title":"","label":"","icon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"zoom":6,"defzoom":14,"layers":["OpenStreetMap"],"image layers":[],"overlays":[],"resizable":false,"fullscreen":false,"scrollwheelzoom":true,"cluster":false,"clustermaxzoom":20,"clusterzoomonclick":true,"clustermaxradius":80,"clusterspiderfy":true,"geojson":"","clicktarget":"","imageLayers":[],"locations":[{"text":"\u003Cb\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003E\u003Ca class=\"mw-selflink selflink\"\u003EENS 52217\u003C/a\u003E - \u003Ca href=\"/Comanche_Peak\" title=\"Comanche Peak\"\u003EComanche Peak\u003C/a\u003E\n\u003C/p\u003E\u003C/div\u003E\u003C/b\u003E\u003Cdiv class=\"mw-parser-output\"\u003E\u003Cp\u003EUnanalyzed Condition on Turbine Driven Auxiliary Feedwater Pump\n\u003C/p\u003E\u003C/div\u003E","title":"ENS 52217 - Comanche Peak\n","link":"","lat":32.29839166666667,"lon":-97.78532222222222,"icon":"/w/images/d/d7/Luminant_icon.png"}],"imageoverlays":null} | |
Unit 1 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
Unit 2 | |
---|---|
Reactor critical | Critical |
Scram | No |
Before | Power Operation (100 %) |
After | Power Operation (100 %) |
WEEKMONTHYEARENS 528172017-06-21T15:00:00021 June 2017 15:00:00
[Table view]10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Postulated Fire Event Could Adversely Impact Safe Shutdown Equipment ENS 526462017-03-29T00:57:00029 March 2017 00:57:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition for a Postulated Moderate Energy Line Break ENS 524842017-01-11T21:00:00011 January 2017 21:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Teflon Found in Containment Spray Pump Components ENS 522442016-09-15T20:40:00015 September 2016 20:40:00 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition, 10 CFR 50.72(b)(3)(v)(C), Loss of Safety Function - Release of Radioactive Material Potential Degradation of Eccs Pump Pressure Indicators ENS 522392016-09-13T22:30:00013 September 2016 22:30:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Involving Station Service Water Trains ENS 522172016-09-01T15:25:0001 September 2016 15:25:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition on Turbine Driven Auxiliary Feedwater Pump ENS 517512016-02-23T23:00:00023 February 2016 23:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Involving Normally Open Battery Room Doors ENS 508352015-02-19T22:00:00019 February 2015 22:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Involving Normally Closed Watertight Doors ENS 500432014-04-18T17:52:00018 April 2014 17:52:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Cable Routing Unanalyzed for Fire Safe Shutdown Barrier ENS 494192013-10-08T17:40:0008 October 2013 17:40:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Postulated Hot Short Fire Event That Could Adversely Impact Safe Shutdown Equipment ENS 477132012-03-01T23:05:0001 March 2012 23:05:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Battery Room Ventilation System Degraded ENS 473572011-10-20T01:02:00020 October 2011 01:02:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Unanalyzed Condition Due to Pressure Instruments Containing Aluminum Material ENS 473522011-10-18T20:45:00018 October 2011 20:45:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Aluminum Valve Discovered Installed in Containment ENS 470862011-07-21T16:53:00021 July 2011 16:53:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Vulnerability from a Potential Control Room Fire on "a" Safeguards Bus ENS 435622007-08-13T14:00:00013 August 2007 14:00:00 10 CFR 50.72(b)(3)(ii)(B), Unanalyzed Condition Inadequate Fire Protection on Safety Chilled Water System Electrical Cables 2017-06-21T15:00:00 | |