ENS 48038
ENS Event | |
|---|---|
21:00 Jun 19, 2012 | |
| Title | Degradation of Safety Equipment |
| Event Description | It was discovered at approximately 1700 EDT on 6/19/2012 that the moderation control in the gadolinia pellet press operation had been degraded. An operator error allowed a can containing approximately 14 kg of uranium powder to be processed without the required material move transaction, a process control that ensures the container and material type are allowed at the designated location.
This resulted in a temporary degraded item relied on for safety (IROFS) condition involving a criticality control. The press moderation control is one of four IROFS to prevent a criticality accident. The gadolinia press station material control system functioned as designed and prompted the operator of an error. The other criticality controls on geometry were maintained at all times. At no time was an unsafe condition present. The gadolinia pellet press operation has been shut down and additional corrective actions, extent of condition, and extent of cause are being evaluated. This event is being conservatively reported pursuant to 10 CFR 70, Appendix A (b) (2).
On 6/20/12, GNF-A conservatively made a 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> event notification (EN 48038) due to a single missed Fuel Business System (FBS) transaction on 6/19/12 at the gadolinia press operation. After further review of the identified condition, it has been determined to be not reportable to NRC and the event notification can be retracted. Notified R2DO (Blamey) and NMSS EO (Silva). |
| Where | |
|---|---|
| Global Nuclear Fuel Wilmington, North Carolina (NRC Region 2) | |
| License number: | SNM-1097 |
| Reporting | |
| Part 70 App A (B)(2) | |
| Time - Person (Reporting Time:+18.5 h0.771 days <br />0.11 weeks <br />0.0253 months <br />) | |
| Opened: | Scott Murray 15:30 Jun 20, 2012 |
| NRC Officer: | Eric Simpson |
| Last Updated: | Jul 11, 2012 |
| 48038 - NRC Website
Loading map... | |
Global Nuclear Fuel with Part 70 App A (B)(2) | |
WEEKMONTHYEARENS 562562022-12-02T20:30:0002 December 2022 20:30:00
[Table view]Part 70 App A (B)(2) Fuel Cycle Facility - Loss or Degradation of Safety Items ENS 533312018-04-12T23:00:00012 April 2018 23:00:00 Part 70 App A (B)(2) Potentially Degraded Items Relied on for Safety ENS 522512016-09-19T10:00:00019 September 2016 10:00:00 Part 70 App A (B)(2) Uf6 Scrubber Exhaust System Not Operating as Required ENS 516622016-01-19T02:00:00019 January 2016 02:00:00 Part 70 App A (B)(2) Accumulation of Uranium Oxide Powder in the Dry Scrap Recycle Furnace Off-Gas System ENS 499692014-03-28T17:30:00028 March 2014 17:30:00 Part 70 App A (B)(2), Part 70 App A (A)(4) Items Relied on for Safety Not Operable ENS 480382012-06-19T21:00:00019 June 2012 21:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 480572012-02-13T13:20:00013 February 2012 13:20:00 Part 70 App A (B)(2) Mass Control Limit Exceeded ENS 466692011-03-10T14:15:00010 March 2011 14:15:00 Part 70 App A (B)(2) Malfunctioning Valve Leads to a Loss of Defense in Depth ENS 464862010-12-16T15:44:00016 December 2010 15:44:00 Part 70 App A (B)(2) Both Hf Detectors in Ghs Test Loop Failed to Be Available and Operable ENS 462442010-09-10T14:00:00010 September 2010 14:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 461682010-01-25T13:50:00025 January 2010 13:50:00 Part 70 App A (B)(2) Degradation of an Item Relied on for Safety ENS 436372007-09-12T15:30:00012 September 2007 15:30:00 Part 70 App A (B)(2) Moderation Control Item Relied on for Safety Degradation 2022-12-02T20:30:00 | |