| Title | Degradation of Safety Equipment |
| Event Description | At approximately 1000 [EDT] on September 10, 2010 during normal operation of a Gad slugger feed hood in the Fuel Manufacturing Building, a connection between the powder hopper and the vibrating feeder was observed as being not properly secured. After starting the vibrating feeder a small amount of powder leaked from the vibrating feeder into the hood. The base of the hood is equipped with a photo-sensor that detected the powder accumulation and automatically shut down the vibrating feeder to stop the leak. A total of 2.2 kg of powder was removed from the hood. An investigation determined that a clamp on the feed tube had not been properly reinstalled following an equipment cleanout.
The two controlled parameters for criticality safety of this equipment are moderation and geometry and Items Relied on for Safety (IROFS) are established for both. With the clamp improperly installed, the geometry-related IROFS was in a degraded state. Additional IROFS on moderation remained available to perform their intended safety functions and were not challenged. Geometry control was maintained by the photo-sensor interlock; however this IROFS is not credited for this accident sequence in the ISA. Although, this event did not result in an unsafe condition and double contingency was maintained, the performance requirements could not be met when taking no credit for the degraded IROFS. As a result, this report is conservatively being made per 10CFR70 Appendix A (b)(2). The Gad slugger and similar equipment have been shutdown pending implementation of additional corrective actions. The licensee will notify the NRC Region 2 Office, the North Carolina Radiation Protection Section and the New Hanover County Emergency Preparedness Organization. |
| Where | |
|---|---|
| Global Nuclear Fuel Wilmington, North Carolina (NRC Region 2) | |
| License number: | SNM-1097 |
| Reporting | |
| Part 70 App A (B)(2) | |
| Time - Person (Reporting Time:+3 h0.125 days <br />0.0179 weeks <br />0.00411 months <br />) | |
| Opened: | Scott Murray 17:00 Sep 10, 2010 |
| NRC Officer: | Vince Klco |
| Last Updated: | Sep 10, 2010 |
| 46244 - NRC Website
Loading map... | |
Global Nuclear Fuel with Part 70 App A (B)(2) | |
WEEKMONTHYEARENS 562562022-12-02T20:30:0002 December 2022 20:30:00
[Table view]Part 70 App A (B)(2) Fuel Cycle Facility - Loss or Degradation of Safety Items ENS 533312018-04-12T23:00:00012 April 2018 23:00:00 Part 70 App A (B)(2) Potentially Degraded Items Relied on for Safety ENS 522512016-09-19T10:00:00019 September 2016 10:00:00 Part 70 App A (B)(2) Uf6 Scrubber Exhaust System Not Operating as Required ENS 516622016-01-19T02:00:00019 January 2016 02:00:00 Part 70 App A (B)(2) Accumulation of Uranium Oxide Powder in the Dry Scrap Recycle Furnace Off-Gas System ENS 499692014-03-28T17:30:00028 March 2014 17:30:00 Part 70 App A (B)(2), Part 70 App A (A)(4) Items Relied on for Safety Not Operable ENS 480382012-06-19T21:00:00019 June 2012 21:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 480572012-02-13T13:20:00013 February 2012 13:20:00 Part 70 App A (B)(2) Mass Control Limit Exceeded ENS 466692011-03-10T14:15:00010 March 2011 14:15:00 Part 70 App A (B)(2) Malfunctioning Valve Leads to a Loss of Defense in Depth ENS 464862010-12-16T15:44:00016 December 2010 15:44:00 Part 70 App A (B)(2) Both Hf Detectors in Ghs Test Loop Failed to Be Available and Operable ENS 462442010-09-10T14:00:00010 September 2010 14:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 461682010-01-25T13:50:00025 January 2010 13:50:00 Part 70 App A (B)(2) Degradation of an Item Relied on for Safety ENS 436372007-09-12T15:30:00012 September 2007 15:30:00 Part 70 App A (B)(2) Moderation Control Item Relied on for Safety Degradation 2022-12-02T20:30:00 | |