ENS 46168
ENS Event | |
|---|---|
13:50 Jan 25, 2010 | |
| Title | Degradation of an Item Relied on for Safety |
| Event Description | On January 25, 2010 during normal operation of a slugger press in the Fuel Manufacturing Building, a tube connecting the feed hood to the press became disconnected. After starting the vibrating feeder, an operator discovered the feed tube was slightly misaligned and some [uranium] powder had spilled into the hood. The operator immediately used the emergency stop button and the equipment was shutdown. A total of 6.9 kg was removed from the hood. An investigation determined that a clamp on the feed tube came loose, allowing the tube to separate from the fit up device.
The two controlled parameters for criticality safety for this equipment are moderation and geometry and Items Relied on for Safety (IROFS) are established for both. When the tube became misaligned, one geometry related IROFS became unavailable to perform its intended safety function. Additional lROFS on geometry and moderation remained available to perform their intended safety functions and were not challenged. Therefore, this did not result in an unsafe condition. GNF-A's [Global Nuclear Fuel-Americas] initial review determined this event was not reportable. However, during an inspection February 22 to 26, 2010, NRC evaluated the event and determined that during the period when the tube was misaligned, one IROFS was not available to perform its intended safety function. Therefore, facility performance requirements were not met and a report to the NRC was required. The NRC issued a notice of violation to GNF-A on March 26, 2010 (70-1113/2010-002-01) for failure to report the event pursuant to 10CFR70 Appendix A(b)(2). The event is now being reported retroactively to satisfy this reporting requirement. The licensee notified the NRC Region 2 Office, the North Carolina Radiation Protection Section and the New Hanover County Emergency Response Organization. |
| Where | |
|---|---|
| Global Nuclear Fuel Wilmington, North Carolina (NRC Region 2) | |
| License number: | SNM-1097 |
| Reporting | |
| Part 70 App A (B)(2) | |
| Time - Person (Reporting Time:+4753.92 h198.08 days <br />28.297 weeks <br />6.512 months <br />) | |
| Opened: | Scott Murray 14:45 Aug 11, 2010 |
| NRC Officer: | Vince Klco |
| Last Updated: | Aug 11, 2010 |
| 46168 - NRC Website
Loading map... | |
Global Nuclear Fuel with Part 70 App A (B)(2) | |
WEEKMONTHYEARENS 562562022-12-02T20:30:0002 December 2022 20:30:00
[Table view]Part 70 App A (B)(2) Fuel Cycle Facility - Loss or Degradation of Safety Items ENS 533312018-04-12T23:00:00012 April 2018 23:00:00 Part 70 App A (B)(2) Potentially Degraded Items Relied on for Safety ENS 522512016-09-19T10:00:00019 September 2016 10:00:00 Part 70 App A (B)(2) Uf6 Scrubber Exhaust System Not Operating as Required ENS 516622016-01-19T02:00:00019 January 2016 02:00:00 Part 70 App A (B)(2) Accumulation of Uranium Oxide Powder in the Dry Scrap Recycle Furnace Off-Gas System ENS 499692014-03-28T17:30:00028 March 2014 17:30:00 Part 70 App A (B)(2), Part 70 App A (A)(4) Items Relied on for Safety Not Operable ENS 480382012-06-19T21:00:00019 June 2012 21:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 480572012-02-13T13:20:00013 February 2012 13:20:00 Part 70 App A (B)(2) Mass Control Limit Exceeded ENS 466692011-03-10T14:15:00010 March 2011 14:15:00 Part 70 App A (B)(2) Malfunctioning Valve Leads to a Loss of Defense in Depth ENS 464862010-12-16T15:44:00016 December 2010 15:44:00 Part 70 App A (B)(2) Both Hf Detectors in Ghs Test Loop Failed to Be Available and Operable ENS 462442010-09-10T14:00:00010 September 2010 14:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 461682010-01-25T13:50:00025 January 2010 13:50:00 Part 70 App A (B)(2) Degradation of an Item Relied on for Safety ENS 436372007-09-12T15:30:00012 September 2007 15:30:00 Part 70 App A (B)(2) Moderation Control Item Relied on for Safety Degradation 2022-12-02T20:30:00 | |