ENS 46486
ENS Event | |
|---|---|
15:44 Dec 16, 2010 | |
| Title | Both Hf Detectors in Ghs Test Loop Failed to Be Available and Operable |
| Event Description | During a performance of internal procedure to verify functionality of installed HF detectors in the Test Loop (TL) Gas Handling System (GHS) room, it was discovered at about 1044 [EST on] 12/16/10, that both IROFS TL-HF-01 and IROFS TL-HF-02 failed to pass internal test requirements. At least one of these HF detector IROFS is required to be available and operable to meet 10 CFR 70.61 performance requirements.
The installed HF detector electrochemical sensors performance appears to have been degraded as a result of low room 'relative humidity' as a result of unusually cold outdoor conditions. The independent IROFS TL-HF-04 (an administrative control) remained intact, thus no unsafe condition existed. While one documented IROFS remained functional (TL-HF-04) to assure the consequence of chemical and radiological exposure is maintained low, TL-HF-04 could not alone meet 10 CFR 70.61 performance requirements. No loss of UF6 containment occurred in affected process equipment. The degradation of TL-HF-01 and TL-HF-02 was observed as part of the IROFS' periodic surveillance. This event is therefore being reported pursuant to the requirements of 10 CFR 70 Appendix A(b)(2) within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. The affected TL bench scale experiment equipment will remain shutdown pending further investigation and implementation of associated corrective actions. SAFETY SIGNIFICANCE OF EVENTS - Low safety significance - the discovery did not result in an unsafe condition. SAFETY EQUIPMENT STATUS - Required IROFS TL-HF-01 and TL-HF-02 functionality being re-established. STATUS OF CORRECTIVE ACTIONS - The affected TL process operation remains shutdown pending investigation and implementation of corrective actions. The licensee will be contacting NRC Region 2, state and local government agencies. |
| Where | |
|---|---|
| Global Nuclear Fuel Wilmington, North Carolina (NRC Region 2) | |
| License number: | SNM-1097 |
| Reporting | |
| Part 70 App A (B)(2) | |
| Time - Person (Reporting Time:+17.33 h0.722 days <br />0.103 weeks <br />0.0237 months <br />) | |
| Opened: | Julie Olivier 09:04 Dec 17, 2010 |
| NRC Officer: | John Knoke |
| Last Updated: | Dec 17, 2010 |
| 46486 - NRC Website
Loading map... | |
Global Nuclear Fuel with Part 70 App A (B)(2) | |
WEEKMONTHYEARENS 562562022-12-02T20:30:0002 December 2022 20:30:00
[Table view]Part 70 App A (B)(2) Fuel Cycle Facility - Loss or Degradation of Safety Items ENS 533312018-04-12T23:00:00012 April 2018 23:00:00 Part 70 App A (B)(2) Potentially Degraded Items Relied on for Safety ENS 522512016-09-19T10:00:00019 September 2016 10:00:00 Part 70 App A (B)(2) Uf6 Scrubber Exhaust System Not Operating as Required ENS 516622016-01-19T02:00:00019 January 2016 02:00:00 Part 70 App A (B)(2) Accumulation of Uranium Oxide Powder in the Dry Scrap Recycle Furnace Off-Gas System ENS 499692014-03-28T17:30:00028 March 2014 17:30:00 Part 70 App A (B)(2), Part 70 App A (A)(4) Items Relied on for Safety Not Operable ENS 480382012-06-19T21:00:00019 June 2012 21:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 480572012-02-13T13:20:00013 February 2012 13:20:00 Part 70 App A (B)(2) Mass Control Limit Exceeded ENS 466692011-03-10T14:15:00010 March 2011 14:15:00 Part 70 App A (B)(2) Malfunctioning Valve Leads to a Loss of Defense in Depth ENS 464862010-12-16T15:44:00016 December 2010 15:44:00 Part 70 App A (B)(2) Both Hf Detectors in Ghs Test Loop Failed to Be Available and Operable ENS 462442010-09-10T14:00:00010 September 2010 14:00:00 Part 70 App A (B)(2) Degradation of Safety Equipment ENS 461682010-01-25T13:50:00025 January 2010 13:50:00 Part 70 App A (B)(2) Degradation of an Item Relied on for Safety ENS 436372007-09-12T15:30:00012 September 2007 15:30:00 Part 70 App A (B)(2) Moderation Control Item Relied on for Safety Degradation 2022-12-02T20:30:00 | |