ENS 48009
From kanterella
Jump to navigation
Jump to search
ENS Event | |
|---|---|
08:00 Jun 10, 2012 | |
| Title | Hpci Declared Inoperable Due to Leakage |
| Event Description | On Sunday June 10, 2012 at 0112 (Central Time), a through-wall leak was discovered on a piping elbow upstream of the High Pressure Coolant Injection (HPCI) Inlet Drain Pot Inboard Drain valve to the Main Condenser, AOV 3-2301-29. This piping elbow is safety-related, ASME Code Class 2 piping. Dresden Technical Requirements Manual 3.4.a, Condition B requires the leak to be isolated which renders the HPCI system inoperable. The Unit 3 HPCI system was isolated and declared inoperable at 0300 (Central Time), and Technical Specification 3.5.1 Condition G has been entered. The HPCI system is a single train system.
The event is being reported pursuant to 10 CFR 50.72(b)(3)(v)(D), any event or condition that at the time of discovery could have prevented the fulfillment of the safety function of structures or systems that are needed to mitigate the consequences of an accident. The licensee notified the NRC Resident Inspector. |
| Where | |
|---|---|
| Dresden Illinois (NRC Region 3) | |
| Reporting | |
| 10 CFR 50.72(b)(3)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident | |
| Time - Person (Reporting Time:+2 h0.0833 days <br />0.0119 weeks <br />0.00274 months <br />) | |
| Opened: | David Carrick 10:00 Jun 10, 2012 |
| NRC Officer: | Dong Park |
| Last Updated: | Jun 10, 2012 |
| 48009 - NRC Website
Loading map... | |
Unit 3 | |
|---|---|
| Reactor critical | Critical |
| Scram | No |
| Before | Power Operation (100 %) |
| After | Power Operation (100 %) |