Pacific Gas and Electric Company February 8, 2010 James R. Becker Site Vice President Diablo Canyon Power Plant Mail Code 104/5/601 P 0. Box 56 Avila Beach, CA 93424 805.545.3462 Internal: 691.3462 Fax: 805.545.6445 PG&E Letter DCL-10-008 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, DC 20555-0001 Docket No. 50-323, OL-DPR-82 Diablo Canyon Unit 2 Inservice Inspection Report for Unit 2 Fifteenth Refueling Outage In accordance with ASME Section Xl, paragraph IWA-6240(b), enclosed is the Diablo Canyon Power Plant Unit 2 Fifteenth Refueling Outage (2R15) Inservice Inspection (ISI) Report. This report provides the results of the ISI examination of Class 1, 2, and 3 components and supports and Reactor Bottom Head Visual inspections.

Also included is a listing of the preservice inspection items and the NIS-2 reports for repair/replacement activities completed since the last Unit 2 refueling outage report submittal.

The Unit 2 reactor vessel upper head was replaced with an integrated head assembly (IHA) and was first placed in service during 2R15.

There are no new or revised regulatory commitments as defined by the Nuclear Energy Institute 99-04, "Guidelines for Managing NRC Commitment Changes,"

dated July 1999, in this report.

If you have any questions regarding the information enclosed, or other ISI program activities, please contact Mr. Patrick Nugent, Manager, Technical Support Engineering, at (805) 545-4701.

James R. Becker swh/469/50047566 Enclosure cc:

cc/encl:

Diablo Distribution Elmo E. Collins, NRC Region IV Michael S. Peck, NRC Senior Resident Alan B. Wang, NRC Project Manager State of California, Pressure Vessel Unit AOCU7 A

member of the STARS (Strategic Teaming and Resource Sharing)

Alliance Cattaway e Comanche Peak

  • Diabto Canyon
  • Palo Verde
  • San Onofre
  • South Texas Project e WolfCreek

-Enclosure PG&E Letter DCL-10-008 Diablo Canyon Power Plant Unit 2 USNRC Docket No. 50-323 Operating License No. DPR-82 Commercial Operation Date, Marclý 13,.1986 Prepared By Mrl1ý,

Thomas L. Alcott / Chris T. Beard, ISI Specialists Reviewed By:

JmsHill, Lead ISI Specialist Approved By:

Patrick Nugent, Manager hnical Support Engineering This report is submitted as required by ASME Boiler and Pressure Vessel Code,Section XI, to the United States Nuclear Regulatory Commission.

Document Date: 2/01/10 Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106 Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424 1

Enclosure PG&E Letter DCL-40-008 SECTION A.

B.

C.

TABLE OF CONTENTS TITLE Introduction ASME Code Report Form NIS-1 (Basis of Summary)

1.

Class 1

2.

Class 2 Class 1 Components

1.

Vessels

a. Reactor Vessel
b. Pressurizer
2.

Bolting

3.

Valves

4.

Piping

5.

Supports Class 2 & 3 Components

1.

Piping

2.

Integral Attachments

3.

Pumps

4.

Supports Containment (IWE) Exams System Pressure Tests Containment Penetration - Appendix J Preservice Inspection Items Repairs and Replacements

1.

ASME Code Report Form NIS-2 (Indexed by System)

(Manufacturers' Data Reports for 'New Items' are attached behind the applicable NIS-2)

D.

E.

F.

G.

H.

I.

2

Enclosure PG&E Letter DCL-10-008 SECTION A INTRODUCTION 3

f Enclosure PG&E Letter DCL-10-008 SECTION A INTRODUCTION Inservice inspection (ISI) of scheduled ASME Section XI Class 1, 2, and 3 components and their supports at Pacific Gas and Electric Company's Diablo Canyon Power Plant, (DCPP) Unit 2 was completed during the fifteenth refueling outage from October through November, 2009. The DCPP Unit 2 fifteenth refueling outage (2R15) was the second outage in the first period within the third 10-year ISI interval.

2R15 exams were scheduled and performed as required by ASME XI, 2001 Edition thru 2003 addenda, as modified by 10CFR 50.55a.

This report is submitted as required by ASME Section XI, paragraph IWA-6240(b), and is organized in several sections. This introduction is Section A. Section B contains the completed ASME Code Report Form NIS-1 for Class 1 and 2 components. Sections C, and D, detail the Class 1, 2 and 3 examinations performed, date of examination (for group items or for more than one type of examination performed, the date provided is the most recent examination date), any unusual conditions noted, corrective actions if required, and explanatory remarks.

Containment (IWE) exams are reported in section E System pressure tests on Class 1, 2, and 3 systems conducted during the period following 2R14, up to and through 2R15, are reported in Section F.

Appendix J, Containment penetration pressure tests are reported in Section G.

Preservice inspections were performed on certain components, as required after repairs or replacements. These items are detailed in Section H.

Section I of this report, Repairs and Replacements, contains the completed ASME Code Report Form NIS-2 for those 2R15 work packages closed prior to or on Dec 10, 2009 and for any pre-2R15 work packages closed after May 12, 2008. NIS-2 reports for 2R15 work packages that are closed after Dec 10, 2009 will be included in the next outage report. Corrective action and Order package documentation are on file at DCPP and are referenced by Order number in the NIS-2 reports.

The Unit-2 Reactor Vessel Upper Head was replaced during 2R15.

Manufacturers' Data Reports for 'New Items' are attached behind the applicable NIS-2.

continued.....

4

Enclosure PG&E Letter DCL-10-008 INTRODUCTION (continued)

In addition to the ASME Code examinations reported here, the following Reactor Vessel examinations were performed during 2R15:

Reactor Vessel Bottom Head Visual Examinations:

On September 10, 2008, the Federal Register published the Final Rule 10 CFR 50,55a(g)(6)(ii)(E)(1) establishing ASME Section XI Code Case N-722-1, with additional conditions stated in 1 OCFR, as the inspection requirement for reactor pressure vessel bottom heads at pressurized water reactor facilities.

In accordance with the requirements of ASME Section XI Code Case N-722-1, Category Item B315.80, the 58 reactor vessel bottom head penetrations were visually examined for evidence of pressure boundary leakage. This was accomplished by use of a robotically deployed inspection camera system whose resolution was confirmed to be equivalent to bare metal direct visual (VE) examination. The Unit 2 bottom head insulation package permits access with this equipment. All 58 bottom mounted instrumentation tube penetrations were examined with no limitations encountered. No evidence of pressure boundary leakage was detected.

5

Enclosure PG&E Letter DCL-10-008 SECTION B ASME CODE REPORT FORM NIS-1 6

Enclosure PG&E Letter DCL-10-008 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1.

Owner Pacific Gas & Electric Company, 77 Beale St., San Francisco, CA 94106

2.

Plant Diablo Canyon Power Plant, P.O. Box 56, Avila Beach, CA 93424

3.

Plant Unit Two

4. Owner Certificate of Authorization (if required)

N/A

5.

Commercial Service Date 03/13/86 6. National Board Number for Unit N/A

7.

Component Inspected ASME Code Class 1 Items Component or Manufacturer or Installer Manufacturer or State or Province National Board Appurtenance Installer Serial No.

No.

No.

Reactor'Vessel Combustion Engineering/

CE 68101 12962-85 21359 (Bottom Head)

Westinghouse Class 1 Pumps Westinghouse 711 N/A N/A RCP 2-1 Class 1 Supports M.W. Kellogg/ Pullman N/A N/A N/A Class 1 Valves Various N/A N/A N/A Class I Piping M.W. Kellogg/ Pullman N/A N/A N/A Pressurizer Safe AREVA N/A N/A N/A End Weld Overlays Pressurizer Westinghouse 1171 N/A 68-106 Reactor Vessel B&W / AREVA 700-0168-52 N/A N/A (Top Head)

Unit #2

  • 1-4

-I-

+

4 4

.1.

I

.1.

Note: Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

7

Enclosure PG&E Letter DCL-10-008 FORM NIS-1 (back)

8.

Examination Dates 10/09 to 11/09-

9.

Inspection Period Identification:

First

10.

Inspection Interval Identification:

Third

11.

Applicable Edition of Section XI 2001 Addenda 2003

12.

Date/Revision of Inspection Plan:

February 2007, Revision A

13.

Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for'current interval.

Refer to ISI Report

14.

Abstract of Results of Examinations and Tests.

Refer to ISI Report

15.

Abstract of Corrective Measures.

Refer to ISI Report We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code;Section XI, and, c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/

Date 2 L?

Signed PG&E By OwnerPatrick Nugent Engi ing Manager CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California and employed by HSB-CT of Harford, CT have inspected the components described in this Owners' Report during the period __

5/08 to 12/09

, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective -measures described in this Owners' Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and tests, and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions CA 1828, NB 9990 A.N.I.C.

pctor' SgNational Board, State, Province and, Endorsements.

Date

,1.-

'l -/o 8

Enclosure PG&E Letter DCL-10-008 FORM NIS-1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

  • 1.

2.

3.

5.

7.

Owner Pacific Gas & Electric Company, 77 Beale St., San Francisco, CA 94106 Plant Diablo Canyon Power Plant, P.O. Box 56, Avila Beach, CA 93424 Plant Unit Two

4. Owner Certificate of Authorization (if required) N/A Commercial Service Date 03/13/86 6. National Board Number for Unit N/A Components Inspected ASME Code Class 2 Items Component or Manufacturer or Installer Manufacturer or State or Province National Board Appurtenance Installer Serial No.

No.

No.

Class 2 Piping Various N/A N/A N/A Supports Class 2 Piping M.W. Kellogg/ Pullman N/A N/A N/A Class 2 Pumps Pacific Pumps 45611 N/A N/A CCP 2-1 U2 Containment Pittsburgh - Des Moines Steel Liner

& PG&E N/A N/A N/A U2 Containment Pittsburgh - Des Moines Steel Bolted Connections

& PG&E N/A N/A N/A Class 2 Vessel Engineers and Fabricators Co.

RHR HX 2-1 S-15588-C N/A 1112

+

I I

+/-

.3.

J

.6.

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 in. x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

9

Enclosure PG&E Letter DCL-10-008 FORM NIS-1 (back) 8..

Examination Dates 10/09 to 11/09

9.

Inspection Period Identification:

First

10.

Inspection Interval Identification:

Third

11.

Applicable Edition of Section XI 2001 Addenda.

2003

12.

Date/Revision of Inspection Plan:

February 2007, Revision A

13.

Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for current interval.

Refer to ISI Report

14.

Abstract of Results of Examinations and Tests.

Refer to ISI Report

15.

Abstract of Corrective Measures.

Refer to ISI Report We certify that a) the statements made in this report are correct, b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and, c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable)

N/A Expiration Date N/A Date

/2

-10 Signed PG&E By___ ___ ___ ___ ___

Owner Patrick Nugent / Enginee'ing Manager CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California and employed by HSB-CT of Harford, CT have inspected the components described in this Owners' Report'during the period 5/08 to 12/09

, and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in this Owners' Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and tests, and corrective measures described in this Owners' Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury l ppdamage or a loss of any kind arising from or connected with this inspection.

Commissions CA 1828, NB 9990 A.N.I.C.

Inspe!or's Signature/Kenny Kim National Board, State, Province and, Endorsements.

Date _ 4

-/0 10

Enclosure PG&E Letter DCL-10-008 SECTION C CLASS ONE COMPONENTS 11

Enclosure PG&E Letter DCL-10-008 PG&E DIABLO CANYON POWER PLANT - UNIT 2 THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

MAJOR ITEM: BOLTING ASME SECTION XI SYSTEMS - CLASS 1 PAGE 1 of 1 CATEGORY COMPONENT /

WELD OR EXAM EXAM ITEM DESCRIPTION LINE COMPONENT NO.

TYPE DATE COMMENTS RESULTS B-G-2 B7.20 Bolts <2" diam B7.60 RCP 2-1Lower Seal Bolts B7.70 RHR Pump 2-1 Inj CL I Pzr2 Manway Bolting Lower Seal Housing Bolts Pzr2 Manway Bolting VT-I 10-22-09 12 RCP Socket Head VT-I Screws 10-14-09 NRI NRI NRI 2S6-3844-6SPL+

2V-8818A Bonnet:

12 Studs & Nuts VT-I 10-13-09 12

Enclosure PG&E Letter DCL-10-008 PG&E DIABLO CANYON POWER PLANT - UNIT 2 THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

MAJOR ITEM: VALVES ASME SECTION XI SYSTEMS - CLASS 1 PAGE I of 1 CATEGORY COMPONENT /

WELD OR EXAM EXAM ITEM DESCRIPTION LINE COMPONENT NO.

TYPE DATE COMMENTS RESULTS B-M-2 B 12.50 Valve Interior 2S6-3846-6SPL+

2V-8818A Interior VT-3 10-13-09 NRI 13

Enclosure PG&E Letter DCL-10-008 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

ASME SECTION XI SYSTEMS - CLASS 1 CATEGORY COMPONENT /

WELD OR EXAM EXAM ITEM DESCRIPTION LINE COMPONENT NO.

TYPE DATE RI-ISI (RB)

DIABLO CANYON POWER PLANT - UNIT 2 MAJOR ITEM: PIPING PAGE 1 of 1 COMMENTS RESULTS Loop I Spray Line Charging Line Loop 4 Accumulator Injection Loop I Accumulator Injection Loop 4 Safety Inj Loop 3 Hot Leg Charging Line Loop 3 Safety Inj Loop 2 Hot Leg 2S6-13-4SPL 2S6-246-3SPL+

2S6-256-10SPL+

2S6-256-10SPL+

2S6-237-6SPL+

2S6-50-3SPL+

2S6-236-6SPL+

WIB-78 WIB-78A WIB-59B WIB-314 WIB-312 WIB-292 WIB-291 WIB-235 WIB-234 WIB-188 WIB-110 UT UT UT UT UT UT UT UT UT UT UT 10-20-09 10-20-09 10-14-09 10-14-09 10-14-09 10-18-09 10-15-09 10-7-09 10-7-09 10-20-09 10-8-09 NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI 14

Enclosure PG&E Letter DCL-10-008 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

ASME SECTION XI SYSTEMS - CLASS I CATEGORY COMPONENT /

WELD OR EXAM EXAM ITEM DESCRIPTION LINE COMPONENT NO.

TYPE DATE Alloy 600 Overlay Welds Pressurizer Surge 2*-16-14SPL WIB-439SE UT.

10-07-09 Line Pressurizer RV 2S6-729-6SPL WIB-369SE UT 10-08-09 8010A Inlet Pressurizer RV 2S6-728-6SPL WIB-423SE UT 10-08-09 8010B Inlet Pressurizer RV 2S6-727-6SPL WIB-359SE UT 10-08-09 8010C Inlet Pressurizer Relief 2S6-730-6SPL WIB-380SE UT 10-08-09 Line Pressurizer Spray 2S6-15-4SPL WIB-345SE UT 10-08-09 Line DIABLO CANYON POWER PLANT - UNIT 2 MAJOR ITEM: PIPING PAGE 1 of 1 COMMENTS RESULTS Overlay Exam (AREVA)

Overlay Exam (AREVA)

Overlay Exam (AREVA)

Overlay Exam (AREVA)

Overlay Exam (AREVA)

Overlay Exam (AREVA)

NRI NRI NRI NRI NRI NRI MRP-146 RCS Loop-I Crossover Drain Line-958-2SPL

, Base mat'l as per eng UT sketch 10-20-09 MRP-146 NRI 15

Enclosure PG&E Letter DCL-10-008 DIABLO CANYON POWER PLANT - UNIT 2 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

MAJOR ITEM: PIPING SUPPORTS ASME SECTION XI SYSTEMS - CLASS 1 PAGE 1 of I CATEGORY F-A SUPPORTS FI.10 TO F1.70 SUPPORT COMPONENTS The required inservice inspections were performed on 30 Class 1 hangers during the fifteenth refueling outage between the dates of 10/06/09 and 10/22/09.

All supports found acceptable. Data reports are on file.

LINE SUPPORT LINE SUPPORT LINE SUPPORT LINE SUPPORT 16 1-23V 246 7-8R 3844 92-40R RCP 2-1 Support Structure 16 1-24V 253 1-27R 13 2-34V 51 2212-20 727 989-17R 13 412-109R 51 2215-5 730 989-23V 13 92-23A 51 409-3A 1665 6-3V

  • 13 92-6V 51 78-363R 1665 6-5V 13 92-72V 51 898-3 1991 2734-36 13 92-8R 51 898-5 1991 2734-40 15 92-4V 235 2-28V 1995 7-33R 15 92-64V 235 412-129R 2575 412-157R 16

Enclosure PG&E Letter DCL-10-008 SECTION D CLASS TWO AND THREE COMPONENTS 17

Enclosure PG&E Letter DCL-I 0-008 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

ASME SECTION XI SYSTEMS - CLASS 2 DIABLO CANYON POWER PLANT - UNIT 2 MAJOR ITEM: PIPING PAGE 1 of 1 CATEGORY COMPONENT/

WELD OR EXAM EXAM ITEM DESCRIPTION LINE COMPONENT NO.

TYPE DATE COMMENTS RESULTS RI-ISI (RB)

Charging Injection Inlet Charging Injection Outlet RHR Injection to Hot Leg 1&2 Stm Gen 1 Feedwater Supply Stm Gen 3 Feedwater Supply Refueling Wtr Stg Tk Out Hdr Res Ht Exchanger 2 Outlet 2S6-2032-6111 2S6-2033-4111 2S1-985-1211P 2K16-554-16IV 2K16-557-161V 2S2-221-18 2S1-119-8111 WIC-1033 WIC-319A WIC-2033A WIC-149A WIC-149B WICG-01-1A WICG-102-1 RB-557-17 RB-221-7 RB-221-8 RB-119-1l UT UT UT UT UT UT UT UT UT

-UT UT 10-6-09 10-6-09 10-6-09 10-18-09 10-18-09 10-19-09 10-19-09 10-18-09 10-1-09 10-1-09 10-1-09 NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI Weld included per RIISI Weld included per RIISI Successive exam due to 2R14 indication -

64002462, reference AR #A0663750 18

Enclosure PG&E Letter DCL-10-008 DIABLO CANYON POWER PLANT - UNIT 2 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

MAJOR ITEM:

INTEGRAL ATTACHMENTS ASME SECTION XI SYSTEMS - CLASS 2 PAGE 1 of I CATEGORY COMPONENT /

WELD OR EXAM EXAM ITEM DESCRIPTION LINE COMPONENT NO.

TYPE DATE COMMENTS RESULTS C-C C3.10 Pressure Vessel welded attachment C3.20 RHR Pump 2-2 Welded Attach.

RHR Pp 2-2 Inj Welded Attach.

CCP 2-1 Disch.

Welded Attach.

Hx to 2V-8106 Welded Attach.

CCP 2-1: Welded Attachments RHR Heat Exchanger 2-1 Line 2S1-111-14111 Line 2S1-509-8111 Line 2S2-45-4 Line 2S6-48-3 Cent Chg Pp 2-1 Support Leg Attmnt Item no. 19 (front) 47-143A Attachment 8-55A Attachment 23-35R Attachment Lugs 949-19 1V Attachment Attachment Weld Items 3,4 PT 10-1-09 PT 10-11-09 PT 10-13-09 PT 10-11-09 PT 10-10-09 PT 10-12-09 NRI NRI NRI NRM NRI NRI 19

Enclosure PG&E Letter DCL-1 0-008 DIABLO CANYON POWER PLANT - UNIT 2 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

MAJOR ITEM: PIPING SUPPORTS ASME SECTION XI SYSTEMS - CLASS 2 PAGE 1 of 1 CATEGORY F-A SUPPORTS FI.10 TO F1.70 SUPPORT COMPONENTS The required inservice inspections were performed on 28 Class 2 hangers during the fifteenth refueling outage between the dates of 10/06/09 and 10/22/09.

All supports found acceptable. Data reports are on file.

LINE SUPPORT LINE SUPPORT LINE SUPPORT LINE SUPPORT 48 949-191V 224 48-22V 509 8-55A CFCU 2-1 Supports 53 23-42R 262 413-526V 572 413-303R SI Pump 2-1 Pp Pedestals and Base 54 564-13 263 413-527V 576 413-424R Steam Generator 2-1 Snub attach belly band 54 564-63 314 404-28R 746 49-112A Steam Generator 2-1 SG-02-01-NE 54 564-152 315 50-2V 927 6-2R Steam Generator 2-1 SG-02-01-NW 111 47-143A 319 8-4R 1466 923-44 Steam Generator 2-1 SG-02-01-SE 112 22-6R 320 414-28R 3844 92-53R Steam Generator 2-1 SG-02-01-SW 20

Enclosure PG&E Letter DCL-10-008 DIABLO CANYON POWER PLANT - UNIT*2 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

MAJOR ITEM: PIPING SUPPORTS ASME SECTION XI SYSTEMS - CLASS 3 PAGE I of 1 CATEGORY F-A SUPPORTS FI.10 TO F1.70 SUPPORT COMPONENTS The required inservice inspections were performed on 8 Class 3 hangers during the fifteenth refueling outage between the dates of 10/06/09 and 10/22/09. All supports found acceptable. Data reports are on file.

LINE SUPPORT LINE SUPPORT LINE SUPPORT LINE SUPPORT 103 413-126A 558 42-IOR 6159 414-789R ASW Pump 2-1 28-44R 127 414-5R 568 414-506V AFW Pump 2-1 Legs pedestal and base Letdown HX 2-1 2 Supports to Base 21

Enclosure PG&E Letter DCL-10-008 SECTION E CONTAINMENT EXAMS 22

Enclosure PG&E Letter DCL-10-008 PG&E DIABLO CANYON POWER PLANT - UNIT 2 THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

MAJOR ITEM: CONTAINMENT ASME SECTION XI SYSTEMS -

PAGE 1 of 1 CONTAINMENT CATEGORY COMPONENT /

WELD OR EXAM EXAM ITEM DESCRIPTION LINE COMPONENT NO.

TYPE DATE COMMENTS RESULTS E-A Containment Liner Containment Liner Containment Liner VT 10-23-09 No major degradation of liner. Paint chips, GEN-1 blistering or gouging and other liner surface discontinuities are listed in the exam report tracking sheets.

NRI E-G Bolted Connections Containment Equipment Hatch Equip Hatch bolting VT-1 (1/3) 11-2-09 NRI 23

Enclosure PG&E Letter DCL-10-008 SECTION F PRESSURE TESTS 24.

Enclosure PG&E Letter DCL-10-008 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

ASME SECTION XI SYSTEMS - CLASS 1, 2, & 3 TEST CLASS DESCRIPTION EXAM NO.

DATE DIABLO CANYON POWER PLANT - UNIT 2 MAJOR ITEM: PRESSURE TESTS PAGE 1 of 4 COMMENTS RESULTS Reactor Coolant System and Connected Piping Excess Letdown between 8166 & 8167 Auxiliary Pressurizer spray Alternate Charging RHR & SI to Cold Legs Charging Injection Inside Cont.

Safety Injection Inside Cont, From 8905A-D to 8949A-D RI-IR Between 8702 & 8701 Auxiliary Feedwater Pump X-1 Discharge RCS Loops 1 & 4 Hot Leg Sample Lines Pressurizer Sample Lines XS Ltdn HX & Piping from 8167 to HCV-123 11-08-09 11-08-09 11-08-09 11-08-09 A 1-08-09 11-08-09 11-08-09 11-08-09 11/11/09 11/09/09 11/09/09 11/09/09 Outage Frequency, STP-R8A Outage Frequency, STP-R8A Outage Frequency, STP-R8A Outage Frequency, STP-R8A Outage Frequency, STP-R8A Outage Frequency, STP-R8A Outage Frequency, STP-R8A Outage Frequency, STP-R8A.

Period-I Exam Period-I Exam Period-I Exam Period-I Exam NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI 2

2 2

25

Enclosure PG&E Letter DCL-10-008 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

ASME SECTION XI SYSTEMS - CLASS 1, 2, & 3 TEST CLASS DESCRIPTION EXA NO.

DAT DIABLO CANYON POWER PLANT - UNIT 2 MAJOR ITEM: PRESSURE TESTS PAGE 2 of 4 COMMENTS RESULTS M

E 7

8 10 11 14 15 i5a 16 19 21 23 24 RCP Hi Press Seal Water Out & XS Ltdn HX Outlet Piping Charging Pumps Discharge Piping Alt Charging Between 8483, 8147 & 8379A Charging Injection 8803A & B to 8801A & B Regenerative HX and Letdown Piping Boric Acid Pumps Disch Piping Boric Acid Pumps Disch Piping Between 8104 and 8445 Boric Acid Tanks to Pump Disch Iso Valves RWST &_Supply to RHR, Cont Spray, SI, Refueling Wtr Purification Pumps & Recirc Line to RHR HX Safety Injection Pump Discharge to 8802A & B and Cold Legs RHR Pumps and Discharge Piping RHR Hot Leg injection from 8703 to 8740A & B 11/09/09 11/09/09 11/09/09 10/28/09 11/09/09 10/31/09 11/04/09 10/29/09 11/02/09 11/09/09 10/26/09 11/08/09 Period-I Exam Period-I Exam Period-I Exam Period-I Exam Period-I Exam Period-I Exam Period-I Exam Period-i Exam Period-I Exam Period-I Exam Period-I Exam Period-I Exam NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI 26

Enclosure PG&E Letter DCL-10-008 I-PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

ASME SECTION XI SYSTEMS - CLASS 1, 2, & 3 TEST CLASS DESCRIPTION EXAM NO.

DATE DIABLO CANYON POWER PLANT - UNIT 2 MAJOR ITEM: PRESSURE TESTS PAGE 3 of 4 COMMENTS RESULTS 25 30 32 41 46 47 la 2

3 4

5 6

Spray Additive Tank and Unisolable piping CCW Supply & Return to Cont Fan Coolers, RCPs and XS Letdown Heat Exchanger RX Vessel Level Indication and Vent System Refueling Canal Water Inlet (pen 46)

RHR Suction from RCS Refueling Canal Water Outlet (pen 47)

Motor Driven Aux Feedwater Pumps Discharge Piping Cross Tie Turbine Driven Auxiliary Feedwater Pump Discharge Piping Condensate Storage Tank & Suction Lines to Auxiliary Feedwater

& makeup Water Pumps Turbine Driven Auxiliary Feedwater Pump Steam Supply Component Cooling Water System (Except Class 2 and Test 6)

Class 3 Component Cooling Water Inside Containment 10/25/09 10/31/09 11/09/09 10/21/09 11/04/09 10/21/09 11/08/09 11/11/09 11/19/09 11/11/09 10/31/09 11/01/09 Period-I Exam Period-i Exam Period-I Exam Period-1 Exam Period-i Exam Period-I Exam Period-I Exam Period-i Exam Period-I Exam Period-1 Exam Period-i Exam Period-i Exam NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI NRI 27

Enclosure PG&E Letter DCL-10-008 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

ASME SECTION XI SYSTEMS - CLASS 1, 2, & 3 TEST CLASS DESCRIPTION EXAM NO.

DATE DIABLO CANYON POWER PLANT - UNIT 2 MAJOR ITEM: PRESSURE TESTS PAGE 4 of 4 COMMENTS RESULTS 7

8 8a 9a 9c 12 13 14 15 16 17 Fire Water Transfer Tank Makeup Water Transfer Pumps Discharge to CCW & Spent Fuel Pit System Makeup Water Transfer Pumps Discharge to SFP (MU-803 to SFP)

ASW Train-i Supply to CCW Heat Exchanger ASW Train-2 Supply to CCW Heat Exchanger Raw Water Storage Reservoir to Auxiliary Feedwater Pumps Suction Raw Water Storage Reservoir to Auxiliary Feedwater Pumps from FCV-436 & 437 to FW-349 & 353 Refuel Water Purification Pump Suction & Discharge SFP to Refuel Water Purification Pump Suction SI Pump Recirc to the RWST RWST / Refueling Canal to Refuel Water Purif Pump Suction Bolted joints following insulation removal at zero pressure and containing Boric Acid.

3/15/09 10/28/09 12/15/09 10/26/09 10/26/09 10/11/09 10/11/09 1/21/10 11/02/09 11/09/09 10/21/09 Period-I Exam Period-1 Exam Period-1 Exam Period-1 Exam Period-1 Exam Period-1. Exam Period-1 Exam Period-I Exam Period-1 Exam Period-1 Exam Period-1 Exam NRI NRI NRI NRI NRI NRI MUI NRI NRI NRI NRI I &2 10/06 thru BA leakage reported on Notifications:

10/22/09 50273822, 50274424, 50276114 RI 28

Enclosure PG&E Letter DCL-10-008 SECTION G ILRT/Appendix J Containment Penetration Pressure Tests Note: All Appendix J penetrations were performed during 2R14.

the Appendix J penetrations listed here are only the penetrations that received an LLRT during 2R15.

29

Enclosure PG&E Letter DCL-10-008 PG&E DIABLO CANYON POWER PLANT - UNIT 2 THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT (2R15)

MAJOR ITEM: Containment Penetration Appendix J ASME SECTION XI SYSTEMS - CONTAINMENT PAGE 1 of I PEN STP Results EXAM PEN STP Results EXAM PEN STP Results EXAM NO.

NO.

DATE NO.

NO.

DATE NO.

NO.

DATE 19 V-619 Acceptable 10/6/09 63 V-663 Acceptable 9/17/09 21 V-621 Acceptable 10/8/09 68 V-668 Acceptable 10/18/09 22 V-623 Acceptable 10/8/09 69 V-668 Acceptable 10/18/09 23 V-623 Acceptable 10/8/09 76A V-676A Acceptable 10/10/09 30 V-630 Acceptable 10/7/09 76B V-676B Acceptable 10/10/09 45 V-645 Acceptable 10/19/09 52E V-678 Acceptable 10/20/09 51B V-651B Acceptable 10/8/09 52F V-678 Acceptable 10/20/09 56 V-656 Acceptable 11/2/09 78A V-678 Acceptable 10/20/09 57 V-657 Acceptable 10/11/09 78B V-678 Acceptable 10/20/09 59A V-659A Acceptable 10/6/09 81 V-681 Acceptable 10/9/09 59B V-659B Acceptable 10/10/09 82A V-682A Acceptable 10/9/09

-59C V-659C Acceptable 10/9/09 82B V-682B Acceptable 10/12/09 61 V-661 Acceptable 9/15/09 82C V-682B Acceptable 10/12/09 62 V-662 Acceptable 9/15/09 30

Enclosure PG&E Letter DCL-10-008 SECTION H PRESERVICE INSPECTION ITEMS 31

Enclosure PG&E Letter DCL-10-008 PG&E DIABLO CANYON POWER PLANT - UNIT 2 THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT MAJOR ITEM: PSI (2R15)

ASME SECTION XI SYSTEMS - CLASS 1, 2, & 3 PRESERVICE INSPECTION ITEMS PAGE 1 of 2 The required preservice inspections were performed on 20 components and 14 supports during the fifteenth refueling outage.

0Other Name of Work Order OteN CTGRSytm EaTyeIdent.

Notes Component System Exam Type No.

Line No B-G-1 New CETNA Housings and 07 VT-I 68006023-0020 RPV CETNAS IPHIAF Inst Port Head Adapter Flange IPHAF Threads B-G-2 RV-8010 SPARE 07 VT-1 60014607-0010 S/N U2SA RV-8010 SPARE 07 VT-1 60014608-0010 S/N U2SB RV-8010 SPARE 07 VT-1 60014609-0010 S/N U2SC RCS-2-8033A 07 VT-1 60002150-0100 LINE-14 RCS-2-8033C 07 VT-1 60006371-0100 LINE-13 RCS-2-8033D 07 VT-1 60006372-0100 LINE-13 RCS-2-8033B 07 VT-1 60006369-0100 LINE-14 CVCS-2-8379A 08 VT-1 60006365-0005 LINE-50 CVCS-2-8379B 08 VT-1 60006366-0005 L1NE-246 CVCS-2-8378A 08 VT-1 60006361-0005 LINE-50 CVCS-2-8378B 08 VT-1 60006363-0005 LINE-246 CVCS-2-LCV-460 08 VT-1 60002143-0100 LINE-24 CVCS-2-8148 08 VT-1 60020193-0100 LINE-4532 SI-2-8948C 09 VT-1 60003025-0200 LINE-255 SI-2-8949A 09 VT-1 60007926-0200 LINE-235 B-M-2 RV-8010 SPARE 07 VT 3-2 60014607-0010 S/N U2SA Converted to Steam Seat RV-8010 SPARE 07 VT 3-2 60014608-0010 S/N U2SB Converted to Steam Seat RV-8010 SPARE 07 VT 3-2 60014609-0010 S/N U2SC Converted to Steam Seat RV-8010 SPARE 07 VT 3-2 60013619-0010 S/N UIA Converted to Steam Seat 32

Enclosure PG&E Letter DCL-10-008 DIABLO CANYON POWER PLANT - UNIT 2 PG&E THIRD INTERVAL, FIRST PERIOD, SECOND REFUELING OUTAGE REPORT MAJOR ITEM: PSI (2R15)

ASME SECTION XI SYSTEMS - CLASS 1, 2, & 3 PRESERVICE INSPECTION ITEMS PAGE 2 of 2 Other C

E RName of Work Order Oden CATEGORY Component System Exam Type No.

Line No B-O CRD HOUSING 55 WELD 07 PT Control Rod Housing Selected ISI welds.

CRD HOUSING 73 WELD 07 PT Control Rod Housing CETNA HOUSING 74 WELD 07 PT CETNA Housing F-A 2216-144 09 VT-3 68005549 Modified a selected support SG 2-1, 2-2, 2-3, 2-4 LLS 07 VT-3 60014441 SG Lower Lateral, SGRP attachments.

Supports AFW Pump 2-1 Base Plate 03 VT-3 60020888-0010 AFW PP 2-1 Welded attachment to pump base plate.

SG02-01SL-SW 04 VT-3 60020038-0010 PAUL-MUNROE Replaced snubber control valve.

70-66SL 04 VT-3 60015127-0200 S/N 75 Replaced Snubber 78-293SL 04 VT-3 60014957-0200 S/N 53 Replaced Snubber 412-154SL 07 VT-3 64012707-0275 S/N 277 Replaced Snubber 413-224SL 07 VT-3 60020225-0200 S/N 138 Replaced Snubber 78-137SL 08 VT-3 60020159-0200 S/N 17 Replaced Snubber 78-419SL 08 VT-3 60015123-0200 S/N 79 Replaced Snubber 72-57SL 14 VT-3 60020226-0200 S/N 57 Replaced Snubber RPV Upper Most NDE performed in Indiana at B&W Head NDE by fabrication facility.

Replacement U2 Reactor Vessel Head 07 AREVA AREVA Traveler RPV Upper Head Omega Seal -weld, head vent piping and Project RVILIS piping NDE performed at DCPP.

Reports available at DCPP.

33

Enclosure PG&E Letter DCL-10-008 SECTION I REPAIRS AND REPLACEMENTS 34

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Date 1/25/10 Sheet I

of I

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Feedwater System (03)

5. (a) Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 (c) Addenda, Code Case N/A
6. Identification of components.

ASME Manufacturer National Other Corrected, O

Code Name of Name of M

Work Order Year C,

Serial Board Identification Removed, or g

Stamped Component Manufacturer No.N.No.

LieNBuilt Intle (Yso No.

No.

Line No Installed

.4 (Yes or No)

Line-566 PG&E N/A N/A C0210613 Line-566-1.5" 1985 Installed (1) 0 No Control FW-2-LCV-1 11 Components 12428-1-2 N/A 60002229 Line-576-3" 1985 Installed (2) 0 No Inc.

AFW PP 2-1 Borg-Warner (baseplate)

N/A 60020888 PP 2-1 1985 Installed (3)

El No baseplate

7. Description of Work (1) Replaced piping. (2) Replaced bonnet, bonnet bolting & internals. (3)Weld studs to baseplate.
8. Tests Conducted:

Hydrostatic E]

Pneumatic El Nominal Operating Pressure 0 Exempt El

. Other F1 Pressure see rmks PSIG Test Temp.

OF

9. Remarks (1) AFW pump 2-2 disch = 1480 psig.

(2) AFW pump 2-2 disch = 1490 psig.

CERTIFICATE OF COMPLIANCE I certify that the statements made'in the report are correct and that this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp N/A rtificte oth ation No.

N/A Expiration Date N/A Signed Engineering Manager

/2-2 1 0 (Owner or Owner'sDesignee)

Patrick Nugent (Title)

CERT1WICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT (g~ate) have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermpre, neitJr the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind a ror ennieted with this inspection.

Inspector

/-

Commissions CA 1828 - NB 9990 A.N.I.C Kenny b. Kim (Title)

(Date)

(State or Province, National Board)

Noteý-Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Date 1/25/10 Sheet 1

of 2

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Main Steam System (4)

5. (a) Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001,

ý03 (c) Addenda, Code Case N/A

6. Identification of components.

ASME.

Nameof Nameof Manufacturer National Work Order Other Year Corrected, Code Serial Board Identification i

Removed, or Stamped No.

No.

Line No Installed (Yes or No)

MS-2-PCV-20 Copes - Vulcan 6910.95009 N/A 60002166 Line-227-8" 1985 Installed (1)

El No MS-2-FCV-95 Velan Valve NF N/A 60006383 Line-760-4" 1985 Installed (2)

El No MS-2-FCV-38 Velan Valve NF 1

N/A 60006385 Line-594-4" 1985 Installed (2)

El No MS-2-PCV-20 Copes -Vulcan 6910.95009 N/A 60008942 Line-227-8" 1985 Installed (3)

El No MS-2-PCV-19 Copes-Vulcan 6910.95009 N/A 60010276 Line-228-8" 1985 Installed (2)(3)

El No

7. Description of Work (1) Replace one stud nut..(2) Replaced bonnet bolting. (3) Replaced internals.
8. Tests Conducted:

Hydrostatic El Pneumatic

[-'E Nominal Operating Pressure [

Exempt E

Other El Pressure

, 1000 PSIG Test Temp.

545

'F

9. Remarks Pressure and Temp are Main Steam in Mode-3 coming out of outage.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp N/A CelificateA uAthorAation No.

N/A Expiration Date N/A Signed 1.--- *4-)

V Z'

f Engineering Manager

/'2-h/

0u (Owner or Owner'sDesignee)

V Patiick Nugent (Title)

(Date)

CERT *(rCATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arilf r cnnected with this inspection.

Inspector

-- 4-/-

Commissions CA 1828-NB 9990 A.N.I.C Kenny D. Kim (Title)

(Date)

(State or Province, National Board)

Noe: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company Date 1/25/10 77 Beale Street, San Francisco, CA 94106 Sheet 2

of 2

2. Plant Diablo Canyon Power Plant Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Main Steam System (4)

Repair Org. P.O. No., Job No., etc.

5.' (a) Applicable Construction Code See Work Order 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 Addenda, Code Case N/A
6. Identification of components.

Name of Name of Manufacturer National Work Other Corrected, ASME Iaeo fa o

Yea CoMe Serial Board Order Identification Removed, or j

Code Component Manufacturer No.

No.

No.

Line No Built Installed Stamped

-(Yes or No)

Stm Gen 2-1 LLS SGT N/A N/A 60014441 Lower Lateral Spt 2008 Installed (4)

El No Stm Gen 2-2 LLS SGT N/A N/A 60014441 Lower Lateral Spt 2008 Installed (4)

El No Stm Gen 2-3 LLS SGT N/A N/A 60014441 Lower Lateral Spt 2008 Installed (4)

',D No Stm Gen 2-4 LLS SGT N/A N/A 60014441 Lower Lateral Spt 2008 Installed (4)

El No

-)

Anchor 78-293SL Darling 53 N/A 60014957 Line-1020-2" Unk Installed (10)

El Yes 70-66SLAnchor 70-66L Darling 75 N/A 60015127 Line-1041-2.5" Unk Installed (10)

El Yes MS-2-RV-224 NWS BN1750 N/A 60018712 Line-1065 1985 Installed (5)(6) 0 No Technologies NWS MS-2-RV-61 Technologies BM07857 N/A 60018773 Line-1066 1985 Installed (5) 0 No MS-2-RV-14 NWS BM7853 N/A 60018779 Line-226 1994 Installed (5) 0 No Technologies SG 2-1 SG02-01SL-SW Paul-Munroe 1697 N/A 60020038 snubber 1985 Installed (7)

El No snubber MS-2-5166 Anchor BD834 N/A 68000813 Line-593-4" 1990 Installed (8)(9) (N) 0 No MS-25166Darling Anchor MS-2-5167 Darling BD833 N/A 68000813 Line-594-4" 1990 Installed (8)(9) (N) 0 No 7Rmrc ino El El (7) Replaced snubber control valve. (8) Replaced valve. (9) Installed pipe flanges. (10) Replaced snubber.

(N) New item. Code Data Report attached.

'I X ~-

x1 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 2

Pg. 1 of

1. Manufactured and certified by Flowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N Certificate Holderl
2. Manufactured for Pacific Gas & Electric Company, P.O. Box 7760, San Frandsco, CA 94120-7760 (name and address of Purchaser)
3. Location of installation Diablo Canyon Power Plant, 800 Price Canyon Rd., Pisnmo Beach, CA 93449 (name and address)
4. Model No., Series No., or Type 600 DURABLA Drawingo7-45546-01 Rev. A.

CRN N/A

5. ASME Code,Section III, Division 1:

1989 NO 3

NIA (edition) laddenda date)

(class)

(Code Case no.)

6. Pump or valve Valve Nominal inlet size 4"

-Outlet size (in.)

(in.)

7. Material:

(a) valve Body SA216 WCB Bonnet NIA Disk SA479-316L Bolting N/A (b) pump Casing Cover Bolting (a)

Cert.

Holder's Serial No.

BD833 BD834 BD835 BD836 BD837 (b)

Nat'l Board No.

N/A N/A N/A N/A N/A (c)

Body/Casing Serial No.

CKYZ-1 C2IHR-2 Qn1HR_3 GCHR-4 C*NDF-5 (d)

Bonnet/Cover Serial No.

N/A N/A N/A N/A N/A (e)

Disk Serial

  • NO.,

27925-1 27925-2 27925-3 27925-4 27925-5

  • Supplemental information In the form of lists, sketches, or drawings may be used provided (1) size Is 81/2 x 11, (2) Information In Items 1 through 4 on this Date Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

2/

  • -1 2.

FORM NPV-1 (Back -

Pg. 2 of 2 Certificate Holder's Serialo 3.thru BD837

8. Design conditions 1085 psi 600

'F or valve pressure class 600 (pressure)

(temperature)

9. Cold working pressure 1480 psi at IO0*F 2251630
10. Hydrostatic test psi. Disk differential test pressure psi
11. Remarks: Seat Rinq, SA351-CF8M, HT Codes as follows: CMHP-1(BD833), CMRT-2IBD834). CMRT-3(BD835).

CMRT-4(BD836). CMRT-5(BD837)

SO 45546, Item 1, 4" Figure 600 DC Valve CERTIFICATION OF DESIGN, Design Specification certified by KJ.E.

State Reg. no.

CM-16690 Design Report certified by N/A RE. State N/A Reg. no.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1562 Expires 11;6-09 DaeY Name RFlowserve Corporation Signed r

Date 6h~

gName Sge IN Certificate Holderl iau ed represeni e)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid.commission issued by the National Board of Boiler and Pressure-Vessel Inspectors and the State or Province of NC and employed by HSB CT A

of Hartford, CT have inspected the pump, or valve, described in this Data Report on III'd/

Z L

.and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section Ill, Division 1.

By signing this certificate neither the inspector nor his employer makes any w4arranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date Q

s FA

-S igned

'*Commissions

________5-Y5______

Itho ed Nuclear lnspe r

[Nat'l. ad. (Incl. endorsements) and state or prow. and no.)

oo~o

,ooo

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106 Date 1/25/10 Sheet 1

of 3

Unit 2

2. Plant Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424
3. Work Performed by
4. Identification of System
Owner, See Above Reactor Coolant System (07)

Repair Org. P.O. No., Job No., etc.

5. (a) Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 (c) Addenda, Code Case N/A
6. Identification of components.

I ~

ASME Manufacturer National Other Corrected, I

Code Name of Name of Work Order Year Serial Board Identification Removed, or 2

Stamped Component Manufacturer No.

Built No.

No.

Line No Installed (Yes or No)

RCP 2-2 Westinghouse 712 C0220413 RCP 2-2 1985 Installed (1)

El No RCS-2-8033A Velan Valve N/A 60002150 Line-14-4" 1985 Installed (2)

El Yes RCS-2-8033B Velan Valve N/A 60006369 Line-14-4" 1985 Installed (2) jE Yes RCS-2-8033C Velan Valve N/A 60006371 Line-13-4" 1985 Installed (2)

El Yes RCS-2-8033D Velan Valve N/A 60006372 Line-14-4" 1985 Installed (2)

El Yes

7. Description of Work (1) Modify shim support plate (welding). (2) Replace bonnet bolting.
8. Tests Conducted:

Hydrostatic E]

Pneumatic E]

Nominal Operating Pressure Z Exempt

[1 Other

[

Pressure 2235 PSIG Test Temp.

547

'F

9. Remarks CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are corr. ct and that this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp i

of Authorization No.

N/A Expiration Date N/A.

Signed f--._3-I J

Engineering Manager

" /2/

/ t)

(Owner or Owner'sDesignee)

Pattak Nugent (Title)

(Date)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore$ neit e the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind aris*

niR ed with this inspection.

Inspector A-LI

- /0 Commissions CA 1828 - NB 9990 A.N.I.C Kenny D. Kim (Title)

(Daie)

(State or Province, National Board)

Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company Date 1/25/10 77 Beale Street, San Francisco, CA 94106 Sheet 2

of 3

2. Plant Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424 Unit 2
3. Work Performed by
4. Identification of System Owner See Above Reactor Coolant System (07)

Repair Org. P.O. No., Job No., etc.

-5. (a) Applicable Construction Code See Work Order 19 Edition Addenda, Code Cases N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

6. Identification of components.
2001, 03 Addenda, Code Case N/A

-3 ASME Manufacturer National Work Other Corrected, Code Serial Board Order Identification Removed, or ComoManufacturer

o.

No.

No.

Line No Built Installed Stamped C

(Yes or No)

RCS-2-9365B Flowserve 69BPE N/A 60007602 Line-2S6-3/4" 1984 Installed (3) (N)

El No RCS-2-PCV-455A Fisher Controls 6468369 N/A 60009352 Line-13-4" 1988 Installed (4)

El No RCS-2-PCV-455B Fisher Controls 6468371 N/A 60009353 Line-14-4" 1988 Installed (4)

El No RCS-2-8093 Flowserve 84BEW N/A 60012485 Lines-3102-3/4" 2009 Installed (3)(5) (N)

El No RCS-2-8093___

Flowserve_

84BEW N/A 60012485

& 7132-3/4" 2009 Intlld()()() _N Line-1469 PG&E N/A N/A 60013854 Line-1469-3/4" 2009 Installed (6)

El No 326-382A PG&E N/A N/A 60013854 Line-7132-3/4" 2009 Installed (7)

El No 326-383R PG&E N/A N/A 60013854 Line-7132-3/4" 2009 Installed (7)

El No 326-384R PG&E N/A N/A 60013854 Line-7132-3/4" 2009 Installed (7)

E No 326-385R PG&E N/A N/A 60013854 Line-7132-3/4" 2009 Installed (7)

El No 326-386R PG&E N/A N/A 60013854 Line-7132-3/4" 2009 Installed (7)

El No 326-387R PG&E N/A N/A 60013854 Line-7132-3/4" 2009 Installed (7)

El No Pzr RV Spare (8010A)

Crosby Valve U2SA Unk 60014607 S/C D957859 Unk Installed (8)(9)

El Yes Pzr RV Spare (8010B)

Crosby Valve U2SB Unk 60014608 S/C D957860 Unk Installed (8)(9)

El Yes Pzr RV Spare (8010C)

Crosby Valve U2SC Unk 60014609 S/C D957858 Unk Installed (8)(9)

El Yes Line-1674 PG&E N/A N/A 60014659 Line-2S6-3/4" 1986 Installed (10)

El No Line-1674 latteral tee PG&E N/A N/A 60014659 Line-2S6-3/4" 2009 Installed (11)

El No RPV Upper Head B&W 700-0168-52 N/A 60015238 RPV Upper Head 2009 Installed (15) 0 Yes 413-224SL Anchor Darling 138 N/A 60020225 Line-2999 Unk Installed (14)

El No Pressurizer Westinghouse 1171 68-106 60020504 Pzr Manway 1973 Installed (12)

El Yes RCS-2-RV-8010A Crosby Valve U2SA Unk 64002772 Line-729-6" 2007 Installed (13) 0I Yes RCS-2-RV-8010B Crosby Valve U2SB Unk 64002773 Line-728-6" 2007 Installed (13) 0 Yes RCS-2-RV-8010C Crosby, Valve U2SC Unk 64002774 Line-727-6" 2007 Installed (13) 0 Yes 4127154SL Anchor Darling 277 N/A 64012707 Line-1195-3" 1985 Installed (14)

El No

7. Remarks (continued),

(3) Replace valve & assoc piping. (4) Replace internals. (5) Install Pzr RV Loop drain piping.

(6) Cut and Cap Class-I pipe. (7) Installed new Class-I support. (8) Replaced internals (convert to steam seat). (9) Replace bolting.

(10) Relocate Class-I piping and thermowell (TW/TE-453).

(11) Bore lateral tee to fit thermowell. (12) Install helicoils for manway diaphragm locating screws. (13)Replaced RV. (14) Replaced snubber. (15) Replace Upper RPV head *

(N) New item. Code Data Report attached.

(*) Also see separate AREVA NIS2.

FORM NIS-2 OWNER'S REPORT OF REPAIROR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company Date 1/25/10 77 Beale Street, San Francisco, CA 94106 Sheet 3

of 3

2. Plant Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424 Unit 2
3. Work Performed by
4. Identification of System Owner See Above Reactor Coolant System (07)

Repair Org. P.O. No., Job No., etc.

5. (a) Applicable Construction Code See Work Order 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Co

2001, 03 de Cases N/A Addenda, Code Case N/A
6. Identification of components.

1 1ASME Name of Name of Manufacturer National Work Other Year Corrected, 2

  • Code Component Manufacturer Serial Board Order Identification Removed, or A

S No.

No.

No.

Line No Built Installed (Yes or No)

RVLIS / RVHVS AREVA N/A N/A 68004061 S6-3/4" & S6-1" 2009 Installed (16)

El No CRDM Omega Seals AREVA N/A N/A 68004325 Omega Seal welds 2009 Installed (17),

El No RVLIS/ RVHVS AREVA N/A N/A 68004329 S6-3/4" & S6-l" 2009 Installed (18)

El No Co Ell CETNA housing AREVA B0707016 N/A 68006023 Location 75 2009 Installed (19)

El No CETNA housing AREVA B0707017 N/A 68006023 Location 76 2009 Installed (19)

El No CETNA housing AREVA B0707018 N/A 68006023 Location 79 2009 Installed (19)

El No CETNA housing AREVA B0707020 N/A 68006023 Location 74 2009 Installed (19)

El No CETNA housing AREVA B0707021 N/A 68006023 Location 77 2009 Installed (19)

E.

No El El El

______El

______El

_El

_____El DIEl

7. Remarks (continued), (16) Track AREVA traveler; 50-9073920 *.(17) Track AREVA traveler; 50-9082 168 *

(18) Track AREVA traveler; 50-9073918 *. (19) Installed CETNA Housings for new RPV head.

()Also see separate AREVA N152.

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code.Section III, Division 1 2

Pg. 1 of

1. Manufactured and certified by Flowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N Certificate Holder)
2. Manufactured for Pacific Gas & Electric Company, P.O. Box 7760, San Francisco, CA 94120-7760 (name and address of Purchaser)
3. Location of installation
  • Diab)o Canyon Power Plant, 800 Price Canyon Rd., Pismo Beach, CA 93449 (name and address)
4. Model No., Series No., or Type 1878# GLOBE VALVE Drawing W9424267 Rev.

G CRN N/A

5. ASME Code,Section III, Division 1:

1986 NO 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6. Pump or valve Valve Nominal inlet size 3/4 Outlet size 3/4 (in.)

(in.)

7. Material:

(a) valve (b) pump A747-CB7-Cul-H1D100 Body SA351-CF8M Bonnet N/A Disk Bolting NIA Casing Cover Bolting (a)

Cert.

Holder's Serial No.

66BPE 67BPE 68BPE 69BPE 70BPE 71BPE 72BPE 73BPE 74BPE 7SBPE 76BPE 77BPE 78BPE 79BPE 80BPE 81BPE 82BPE 83BPE 84BPE 85BPE (b)

Nat'l Board.

No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (c)

Body/Casing Serial No.

P3448-11 P3448-12 P3448-13 N5522-10 N5522-11 N5522-12 N5522-13 N5522-14 N5522-15 N5522-16 P3448-14 P3448-15 P3448-16 P3448-17 P3448-18 P3448-19 P3448-20 P3448-21 P3448-22 P3448-23 Id)

Bonnet/Cover Serial No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (e)

Disk Serial No.

6992-51 6992-52 6992-53 j

6992-54 6992-55 6992-56 6992-57 6992-58

.6992-59 6992-60 6992-6

.6992-7 6992-8

-6992-9 6992-10 6992-46 6992-47 6992-48

'6992-49 6992-50

  • Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 81/2 x 11, 12) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

I FORM NPV-1 (Back-- Pg. 2 of 2 Certificate Holder's Serial No.

66BPE THRU 856PE

8. Design conditions 273psi or valve ressure class 1878 (pressure)

(temperature)

9. Cold working pressure 4507 psi at 100°F 6775 4960
10. Hydrostatic test psi.

Disk differential test pressure psi

11. Remarks: 'S.0. 53099-07 CERTIFICATION OF DESIGN Design Specification certified by Floyd-A. Bensinger P.E. State PA Reg. no. PE-31002-E Design Report certified by Ron S. Farrell RE. State NC Reg. no. 028656 -

CERTIFICATE OF COMPLIANCE We dertify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1562 Expires 11-26-09 Date e* a'S 0 Name Flowserve Corporation Signed (N Certificate Holder)

(

Zf 1resendve)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC_._

and employed by HSB CT.

  • of Hartford, CT have inspected the pump, or valve, described in this Data Report on A,

TZ9 Z _6 and state that to the best of my knowledge and belief, the Certificate Holder has constructed.this pump, or valve, in accordance with the ASME Code, Section I11, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date S )'")

Sign I

ACommissions e-7 s"ao ear Inspetor).

INatl. Bd. (incL. endorsements) and state or prov. and no.)

3

7, FORM NPV-1 N CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Div. I Pg. I of 2

1.

Manufactured by Flowserve Corporation, 1900 S. Saunders St.

Raleigh, NC 27603 2.

3.

(Name and Address of N Certificate Holder)

Manufactured for Pacific Gas and Electric PO Box 7760 San Francisco, CA 94120-7760 (Name and Address of Purchaser or Owner)

Location of Installation Diablo Canyon Power Plant 800 Price Canyon Rd. Pismo Beach, CA 93449 (Name and Address)

4.

Pump or Valve Valve Nominal Inlet Size 3/4" (inch)

Outlet Size 3/4" (inch)

(a) Model No.

Series No.

or Type (b) N Certificate Holders Serial, No.

(c) Canadian Registration

, No.

(d) Drawing No.

(f) Nat'l.

Bd. No.

(g) Year Built (e) Class 5

6 7

8

. (1) 1878#

_-'/

83BEW N/A W9424267 REV. E I

N/A 2006

' (2) 1878#

y 84BEW N/A W9424267 REV. E 1

N/A 2006 (3) 1878#

85BEW N/A W9424267 REV. E I

N/A 2006 (4) 1878#

86BEW N/A W9424267 REV. E 1

N/A 2006 (5) 1878#

87BEW N/A W9424267 REV. E 1

N/A 2006 (6) 1878#

t,,-"88BEW N/A W9424267 REV. E 1

N/A 2006

.(7) 1878#

89BEW N/A W9424267 REV. E 1

N/A 2006 (8) 1878# "

90BEW N/A W9424267 REV. E 1

N/A 2006 (9) 1878#

91BEW N/A W9424267 REV. E 1

N/A 2006 (10) 1878#

_92BEW N/A W9424267 REV. E 1

N/A 2006

%1"-1878 Globe Valve (Brief description of service for whidc e-oulpment was designed) 36699 Item 007 Design Conditions 2735 psi 680 OF or Valve Pressure Class 1878 (1)

(Pressure)

(Temperature)

Cold Working Pressure 4507 psi at 100 OF.

Pressure Retaining Pieces Mark No.

Material Spec. No.

Manufacturer Remarks N3317 SA351 CF8M Flowserve Body (b)

Forgings "

E3239 A747-Cb7-Cul-H1100 Deloro Disc L

I J

(1) For manually operated valves only

  • Supplemental sheets in form of lists, sketches or drawings may be used provided (1) size is 8-112. x 11",

(2) information in items 1, 2 and 5 on this Data Report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at top of this form.

FORM NPV-1 (Back)

Pg. 2 of 2 Valve S/N 83BEW through 92BEW Mark No.

Material Spec. No.

Manufacturer Remarks (c) Bolting (d) Other Parts

9.

Hydrostatic test 6775 psi.

Disk Differential test pressure 4960 Psi.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump, or valve, to the rules of construction conforms 1986 of the ASME Code for Nuclear Power Plant Components.

Section III, Div.

1.,

Edition Addenda No Code Case No, N/A Date

'Signed Flowserve Corp.

by (N Certiftcate Holder)

Our ASME Certificate of Authorization No.

N-1562 to use the N

symbol expires 11-26-06 4N)

(Date)

CERTIFICATION OF DESIGN Design information on file at Flowserve Corporation Raleigh, NC Stress analysis report (Class 1 only) on file at Flowserve Corporation Raleigh, NC Design specifications certified by (1)

Mark Cowell PE State PA Reg. No.

032082 Stress analysis certified by.(1)

R.S. Farrell PE State NC Reg. No.

028656 (1) Signature not required-List name only.

CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by

,HSB CT of Hartford Connecticut have inspected the pump, or valve, described in this Data Report on JfJ

,-A_

and state that, to the best of my knowledge and belief, the N Certificate Holder has constructed this pump, or valve, in accordance with ASME Code, Section I11.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this s Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this Inspection.

Date 9'

I g.._/

Signed

~ ~

(

Commissions Aj c Z/

/

(Inspector)

(Nat'l Sd., State, Prov. and No.)

7/

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St. San Francisco. CA 94105. USA Date November 4. 2009 Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56, Avila Beach CA 94354, USA Sheet 1

of 7

Unit 2

See Remarks Address

3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Road, Lynchbure VA 24501, USA Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A Reactor Coolant System (07)

Address

4. Identification of System Reactor Vessel (Class 1),

[

I

[

5. (a) Applicable Construction Code ASME

,II 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section Xl Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built Removed, or Stamped copoen Mnuacurr eralInstalled (Yes or No)

Reactor Babcock and 700-0168-N/A N/A 2009 Installed Yes Head Wilcox 52 Unit #2 Nuclear Operations Group CRDM-Rod Jeumont SA DBC 45 N/A 1/H8 2009 Installed No Travel Housing (CRDM-RTH)

CRDM-RTH Jeumont SA DBC 48 N/A 2/F8 2009 installed No CRDM-RTH Jeumont SA DBC 25 N/A 3/H10 2009 Installed No CRDM-RTH Jeumont SA DBC 39 N/A 5/K8 2009 Installed No CRDM-RTH Jeumont SA DBC 32 N/A 6/H6 2009 Installed No CRDM-RTH Jeumont SA DBC 30 N/A 7/F10 2009 Installed No CRDM-RTH Jeumont SA DBC 43 N/A 8/K10 2009 Installed No CRDM-RTH Jeumont SA DBC 53 N/A 9/K6 2009 Installed No CRDM-RTH Jeumont SA, DBC 51 N/A 10/F6 2009 Installed No CRDM-RTH Jeumont SA DBC 51 N/A 14/D8 2009 Installed No CRDM-RTH Jeumont SA DBC 44 N/A 14/D8 2009 Installed No CRDM-RTH Jeumont SA DBC 46 N/A 15/H812 2009 Installed No CRDM-RTH Jeumont SA DBC 35 N/A 16/M8 2009 Installed No

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure E, ExemptO Other 0 Pressure 2235 psi Test Temp. _

547_0 F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2 x ll in., (2) information in items I through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St. San Francisco. CA 94105. USA Date November 4, 2009 Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56, Avila Beach CA 94354, USA Sheet 2

of 7

Unit 2

See Remarks Address

3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Road, Lynchburg VA 24501, USA Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A Reactor Coolant System (07)

Address

4. Identification of System Reactor Vessel (Class 1")

I r

  • f *
  • i vI
5. (a) Applicable Construction Code ASME 111, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section Xl Code Cases -NoneI

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built

Removed, Stamped com onntor Installed (Yea or No)

CRDM-RTH Jeumont SA DBC 15 N/A 17/H4 2009 Installed No CRDM-RTH Jeumont SA DBC 26 N/A 30/C9 2009 Installed No CRDM-RTH Jeumont SA DBC 23 N/A 31/G13 2009 Installed No CRDM-RTH Jeumont SA DBC 11 N/A 32/J13 2009 Installed No CRDM-RTH Jeumont SA DBC 22 N/A 33/N9 2009 Installed No CRDM-RTH Jeumont SA DBC 27 N/A 34/N7 2009 Installed No CRDM-RTH Jeumont SA DBC 9 N/A 35/J3 2009 Installed No CRDM-RTH Jeumont SA DBC 14 N/A 36/G3 2009 Installed No CRDM-RTH Jeumont SA DBC 34 N/A 37/C7 2009 Installed No CRDM-RTH Jeumont SA DBC 41 N/A 38/D12 2009 Installed No CRDM-RTH Jeumont SA DBC 6 N/A 39/M12 2009 Installed No CRDM-RTH Jeumont SA DBC 16 N/A 40/M4 2009 Installed No CRDM-RTH Jeumont SA DBC 21 N/A 41/D4 2009 Installed No CRDM-RTH Jeumont SA DBC 18 N/A 42/Cll 2009 Installed No CRDM-RTH Jeumont SA DBC 47 N/A 43/E13 2009 Installed No

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic El Nominal Operating Pressure 0 ExemptO Other 0 Pressure 2235 psi Test Temp.

547__F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2/2 x 11 in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St. San Francisco. CA 94105. USA Date November 4, 2009 Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56, Avila Beach CA 94354, USA Sheet 3

of 7

Unit 2

See Remarks Address

3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Road, Lynchburg VA 24501, USA Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A Reactor Coolant System (074 Address

4. Identification of System Reactor Vessel (Class 1),
5. (a) Applicable Construction Code ASME III, 2001 Edition, 2003 Addenda, N/A Code Case

" Year (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section XI Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built

Removed, Stamped or Installed (Yes or No)

CRDM-RTH Jeumont SA DBC 12 N/A 44/L1-3 2009 Installed No CRDM-RTH Jeumont SA DBC 54 N/A 45/Nll 2009 Installed No CRDM-RTH Jeumont SA DBC 3 N/A 46/N5 2009 Installed No CRDM-RTH Jeumont SA DBC 40 N/A 47/L3 2009 Installed No CRDM-RTH Jeumont SA DBC 33 N/A 48/E3 2009 Installed No CRDM-RTH Jeumont SA DBC 2 N/A 49/C5 2009 Installed No CRDM-RTH Jeumont SA DBC 36 N/A 50/138 2009 Installed No CRDM-RTH Jeumont SA DBC 5 N/A 51/-14 2009 Installed No CRDM-RTH Jeumont SA DBC 42 N/A 52/P8 2009 Installed No CRDM-RTH Jeumont SA DBC 1 N/A 53/H12 2009 Installed No CRDM-RTH Jeumont SA DBC 49 N/A 54/310 2009 Installed No CRDM-RTH Jeumont SA DBC 7 N/A 55/F14 2009 Installed No CRDM-RTH Jeumont SA DBC 50 N/A 56/K14 2009 Installed No CRDM-RTH Jeumont SA DBC 38 N/A 57/P10 2009 Installed No CRDM-RTH Jeumont SA-DBC 17 N/A 58/P6 2009 Installed No CRDM-RTH Jeumont SA DBC 13 N/A 59/K2 2009 Installed No

7.

bescription of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic El Nominal Operating Pressure El ExemptO Other 0 Pressure 2235 psi Test Temp.

547__F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2/2 x 11 in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St. San Francisco. CA 94105. USA Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56, Avila Beach CA 94354, USA Date November 4, 2009 Sheet 4

of 7

Unit 2

See Remarks Address

3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Road, Lynchburg VA 24501, USA Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A -

Reactor Coolant System (07)

Address

4. Identification of System Reactor Vessel (Class 1),

r i

i

5. (a) Applicable Construction Code ASME III, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section XI Code Cases None

6. Identification of Components:

7

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 0 ExemptO Other 0l Pressure 2235 psi Test Temp.

547_ 0F NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 V2 x ItI in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As, Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St. San Francisco, CA 94105. USA Date November 4. 2009 Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56. Avila Beach CA 94354. USA Sheet 5

of 7

Unit 2

See Remarks Address

3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Road. 1.vnchhburg VA 24501. lSA Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A Reotnr Coolaint Sv~tem (0Th' 3315 Old Forest Road Lvnchburg VA 24501 USA Address

4. Identification of System Reactor Vessel (Class 1),

Reactor Coolant Svstem (071

5. (a) Applicable Construction Code ASME 111, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section XI Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code Manufacturer Serial No.

Board No.

Other Identification Built

Removed, Stamped component or Installed (Yes or No)

RVHVS piping AREVA NP 9082836-N/A N/A 2009 Installed Yes Sub assembly 003

-3 Reactor AREVA NP N/A N/A 2009 Installed Yes Vessel Level Indication System (RVLIS) piping subassembly-9091693-1 001 RVLIS piping AREVA NP N/A N/A 2009 Installed Yes subassembly-9091693-2 002 RVLIS piping AREVA NP N/A N/A 2009 Installed Yes subassembly-9091693-3 003 RVLIS piping AREVA NP N/A N/A 2009 Installed No subassembly-9091693-4 004 RVLIS piping AREVA NP N/A N/A 2009 Installed Yes subassembly-9091693-5 005

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Pressure 2235 psi Nominal Operating Pressure 0 ExemptO Test Temp. _

547 OF Other E0 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2/2 x 11 in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St. San Francisco. CA 94105. USA Date November 4, 2009 Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56, Avila Beach CA 94354, USA Address
3. Work Performed by AREVA NP, Inc.

Name 33l 5 Old Fnrett Rn~d IvncehhuircrVA 94*fl1 lISqA Sheet 6

of 7

Unit 2

See Remarks Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A actor Coolant System (07)

Address

4. Identification of System Reactor Vessel (Class 1),
5. (a) Applicable Construction Code ASME 111, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section XI Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built

Removed, Stamped comonntor Insalnled (Yesnor No)

Solenoid AREVA NP 9082837-N/A N/A 2009 Installed Yes Operated 001 Valve (SOV)Subass' embly -1 (SOV)Subass AREVA NP 9082837-N/A N/A 2009 Installed Yes embly -2 002 J

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Pressure 2235 psi Nominal Operating Pressure 0 ExemptEr Test Temp. __547_0 F Other 0 NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 V2 x 11 in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

Sheet 7 of 7 FORM NIS-2 (Back)

9.

Remarks: N-2 forms for the Reactor Vessel Head and CRDMs are attached. N-5 forms for RVHVS and, RVLIS are attached.

Applicable Manufacturer's Data Reports to be attached Other items installed are as follows:

See AREVA NP Documents 50-9073915-003, 50-9073916-003, 50-9073917-000, 0-9073918-003, & 50-9073920-003.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

N/A Signed Date 20 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ca.

and employed by.

HSB-CT_

of HartfordCT have inspected the components described in this Owner's Report during the period 5/13, 2008 to 12/10, 2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions CA 1828 - NB 9990 A.N.I.C SInspector's Signature National Board, State, Province, and Endorsements Date

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric, Name 77 Beale St, San Francisco, CA 94105, USA Address
2. Plant Diablo Canvon Power Plant Date November 4, 2009 Name P.O Box 56, Avila Beach CA 94354, USA Address
3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Roaid l.vnehhturs VA 924501 lISA Sheet 1

of.

7 Unit 2

See Remarks Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A Reactor Coolant System (07) 3315 Old Forest Road Lvinchburo VA 24501 USA Address

4. Identification of System Reactor Vessel (Class 1)
5. (a) Applicable Construction Code ASME III, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section XI Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built Removed, or Stamped

____________Installed Yes or No)

Reactor Babcock and 700-0168-N/A N/A 2009 Installed Yes Head Wilcox 52 Unit #2 Nuclear Operations Group CRDM-Rod Jeumont SA DBC 45 N/A 1/H8 2009 Installed No Travel Housing (CRDM-RTH)

CRDM-RTH Jeumont SA DBC 48 N/A 2/F8 2009 Installed No CRDM-RTH Jeumont SA DBC 25 N/A 3/H110 2009 Installed No CRDM-RTH Jeumont SA DBC 39 N/A 5/K8 2009 Installed No CRDM-RTH Jeumont SA DBC 32 N/A 6/H6 2009 Installed No CRDM-RTH Jeumont SA DBC 30 N/A 7/F10 2009 Installed No CRDM-RTH Jeumont SA 209N

\\

DBC 43 N/A 8/K10 2009 Installed No CRDM-RTH Jeumont SA N/A 2009 Installed No DBC 53 N/A 1/6 2009 Installed -No CRDM-RTH Jeumont SA DBC 51 N/A 10/D6 2009 Installed.

No CRDM-RTH Jeumnont SA 2009 Isald N

__________DBC 44 N/A 14/D8 I

09 Intlld N

CRDM-RTH Jeumont SA DBC 46 N/A 15/H12 2009 InstaIled No CRDM-RTH Jeumont SA DBC 35 N/A 16/M8 2009 Installed No

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 9/ ExemptO Other El Pressure 2235 psi Test Temp.

547 OF NOTE: Supplemental sheets in form of lists, sketches;or drawings may be used, provided (1) size is 8 V2 x 11 in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St, San Francisco, CA 94105, USA Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56. Avila Beach CA 94354. USA Date November 4. 2009 Sheet 2

of 7

Unit 2

See Remarks Address

3. Work Performed by AREVA NP, Inc.

Name '

3315 Old Forest Road. Lvnchbur, VA 2450 1. USA Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp

. N/A Authorization No.

N/A Expiration Date N/A Reactor Coolant System (07)

Address

4. Identification of System Reactor Vessel (Class 1)
5. (a) Applicable Construction Code ASME 111, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section Xl Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built

Removed, Stamped c or Installed (Yes or No)

CRDM-RTH Jeumont SA DBC 15 N/A 17/H4 2009 Installed

.No CRDM-RTH Jeumont SA DBC 26 N/A 30/C9 2009 Installed No CRDM-RTH Jeumont SA DBC 23 N/A 31/G13 2009 Installed No CRDM-RTH Jeumont SA DBC 11 N/A 32/J13 2009 Installed No CRDM-RTH Jeumont SA DBC 22 N/A 33/N9 2009 Installed No CRDM-RTH Jeumont SA DBC 27 N/A 34/N7 2009 Installed No CRDM-RTH Jeumont SA DBC 9 N/A 34/N7 2009 Installed No CRDM-RTH Jeumont SA DBC 9 N/A 35/J3 2009 Installed No CRDM-RTH Jeumont SA DBC 14 N/A 36/G3 2009 Installed No CRDM-RTH Jeumont SA DBC 34 N/A 37/C7 2009 Installed No CRDM-RTH Jeumont SA DBC 34 N/A 38/D12 2009 Installed No CRDM-RTH Jeumont SA DBC 16 N/A 39/M12 2009 Installed No CRDM-RTH Jeumont SA DBC 61 N/A 40/M4 2009 Installed No CRDM-RTH Jeumont SA DBC 16 N/A 41/Ml 2009 Installed No CRDM-RTH Jeumont SA DBC 21 N/A 42/E11 2009 Installed No CRDMV-RTH Jeumont SA DBC 47 N/A 43/E13 2009 Installed No

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure a"iExemptD Other 0 Pressure 2235 psi Test Temp.

547 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2/2 x 11 in., (2) information in items I through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St, San Francisco, CA.94105, USA Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56. Avila Beach CA 94354. USA Date November 4, 2009 Sheet 3

of 7

Unit 2

Address

3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Roadl.Lvnchburo VA 24501. USA See Remarks Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A actor Coolant System (07) 3315 Old Forest Road Lvnchburg VA 24501 USA Address

4. Identification of System Reactor Vessel (Class 1)
5. (a) Applicable Construction Code ASME 111, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section Xl Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section Xl Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built

Removed, Stamped or Installed lYes or No)

CRDM-RTH Jeumont SA DBC 12 N/A 44/L13 2009 Installed No CRDM-RTH Jeumont SA DBC 54 N/A 45/N1l 2009 Installed No CRDM-RTH Jeumont SA DBC 3 N/A 46/N5 2009 Installed No CRDM-RTH Jeumont SA DBC 40 N/A 47/L3 2009 Installed No CRDM-RTH Jeumont SA DBC 33 N/A 48/E3 2009 Installed No CRDM-RTH Jeumont SA DBC 2 N/A 49/C5 2009 Installed No CRDM-RTH Jeumont SA DBC 36 N/A 50/B8 2009 Installed No CRDM-RTH Jeumont SA DBC 5 N/A 51/H14 2009 Installed No CRDM-RTH Jeumont SA DBC 42 N/A 52/P8 2009 Installed No CRDM-RTH Jeumont SA DBC 1 N/A

'53/H2 2009 Installed No CRDM-RTH Jeumont SA DBC 49 N/A 54/B10 2009 Installed No CRDM-RTH Jeumont SA DBC 7 N/A 55/F14 2009 Installed No CRDM-RTH Jeumont SA DBC 50 N/A 56/K14 2009 Installed No CRDM-RTH Jeumont SA DBC 38 N/A 57/P10 2009 Installed No CRDM-RTH Jeumont SA DBC 17 N/A 58/P6 2009 Installed No CRDM-RTH Jeumont SA DBC 13 N/A 59/K2 2009 Installed No

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDMI i

i.

Nominal Operating Pressure r'/ExemptO

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Other E0 Pressure 2235 psi Test Temp.

547 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/2/2 x I t in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St, San Francisco, CA 94105, USA Address

2. Plant Diablo Canyon Power Plant November 4. 2009 Date Sheet Unit 4

of 7

2 Name P.O Box 56. Avila Beach CA 94354. USA See Remarks Address

3. Work Performed by AREVA NP. Inc.

Name 3315 Old Forest Road, Lynchburg VA 24501, USA Address

4. Identification of System Reactor Vessel (Class 1)

I Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp

'N/A Authorization No.

N/A Expiration Date, N/A Reactor Coolant System (07)

5. (a) Applicable Construction Code ASME III, 2001. Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section Xl Code Cases None

6. Identification of Components:

',7

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure ExemptO Other 0 Pressure 2235 psi Test Temp.

547 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (I) size is 8 1/2/2 x 11 in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Coderr Section XI

1. Owner Pacific Gas and Electric.

Name 77 Beale St, San Francisco, CA 94105, USA Date November 4, 2009 Sheet 5

of 7

Unit 2

Address

2. Plant Diablo Canyon Power Plant Name P.O Box 56, Avila Beach CA 94354, USA See Remarks Address
3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Road, Lynchburg VA 24501, USA Address

4. Identification of System Reactor Vessel (Class 1)

Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A Reactor Coolant Svstem (07)

5. (a) Applicable Construction Code ASME Ill, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section XI Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section XI Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built

Removed, Stamped e

Mor Installed (Yes or No)

RVHVS piping AREVA NP 9082836-N/A N/A 2009

!nstalled Yes Sub assembly 003

-3 Reactor AREVA NP N/A N/A 2009 Installed Yes Vessel Level Indication System (RVLIS) piping subassembly-9091693-1 001 RVLIS piping AREVA NP N/A N/A 2009 Installed Yes subassembly-9091693-2 002 RVLIS piping AREVA NP N/A N/A 2009 Installed Yes subassembly-9091693-3 003 RVLIS piping AREVA NP N/A N/A 2009 Installed No subassembly-9091693-4 004 RVLIS piping AREVA NP N/A N/A 2009 Installed Yes subassembly-9091693-.

5 005

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic 0 Pneumatic 0 Nominal Operating Pressure 3e//Exempto Other 0 Pressure 2235 psi Test Temp.

547 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 '/2 x 11 in., (2) information in items 1 through 6 of this reportis included on each sheet, and (3) each sheet-is numbered and number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT FOR REPAIR/REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code,Section XI

1. Owner Pacific Gas and Electric.,

Name 77 Beale St, San Francisco, CA 94105, USA Date November 4. 2009 Address

2. Plant Diablo Canyon Power Plant Sheet 6

of 7

Unit 2

Name P.O Box 56. Avila Beach CA 94354. USA See Remarks I

Address

3. Work Performed by AREVA NP, Inc.

Name 3315 Old Forest Road_ l~vnchbutr*VA 24501_ 11SA Repair/Replacement Organization P.O. Box, Job No., etc.

Type Code Symbol Stamp N/A Authorization No.

N/A Expiration Date N/A Reactor roolant Syvstem (07*

3315 Old Forest Road Lvnchburp VA 24501 USA Address

4. Identification of System Reactor Vessel (Class 1)

Reactor Coolant Svstem (07)

5. (a) Applicable Construction Code ASME 111, 2001 Edition, 2003 Addenda, N/A Code Case Year (b) Applicable Edition of Section X1 Utilized for Repair/Replacement Activity 2001 Ed. thru 2003 Addenda.

Year (c) Applicable Section Xl Code Cases None

6. Identification of Components:

Name of Name of Manufacturer National I

Year Corrected, ASME Code component Manufacturer Serial No.

Board No.

Other Identification Built

Removed, Stamped or Installed (Yes or No)

Solenoid AREVA NP 9082837-N/A N/A 2009 Installed Yes Operated 001 Valve (SOV)Subass embly -1 (SOV)Subass AREVA NP 9082837-N/A N/A 2009 Installed Yes embly -2 002

7.

Description of Work Installed new Reactor Head and Control rod Drive Mechanisms (CRDM).

8.

Tests Conducted:

Hydrostatic []

Pneumatic 0 Other El Pressure 2235 psi Nominal Operating Pressure I/ExemptO Test Temp.

547 OF NOTE: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8 1/22 x 11 in., (2) information in items 1 through 6 of this report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded at the top of this form.

Sheet 7 of 7 FORM NIS-2 (Back)

9.

Remarks: N-2 forms for the Reactor Vessel Head and CRDMs are attached. N-5 forms for RVHVS and, RVLIS are attached.

Applicable Manufacturer's Data Reports to be attached Other items installed are as follows:

See AREVA NP Documents 50-9073915-003. 50-9073916-003. 50-9073917-000. 0-9073918-003. & 50-9073920-003.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp N/A Certificate of Authorization No.

Signed06MA N/A

--. -,1.........

m.......

,1 -.

(Title)

Date f'rls "Z

20 11)

Patrick Nuqlnt (Title)

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of CA.

and employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13 2008 to 12/10

.2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XL.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Inspector Commissions CA 1828 - NB 9990 A.N.I.C Kenny

. Kim (Title)

(State or Province, National Board)

Date 4---

q

/0

B&W QADP Section IX Page 2 FORM Z2 CERTIFICATE HOLDER'S DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III Not to Exceed One Day's Production Pg. Iof 3

1. Manulactured and criilied by Babcock & Wilcox Nuclear Operations Group, 400 Old Hihway 69_SouthMt.Vernon, IN (USA)

(name

-nd address of NPTCerthifts Holder)

Pacific Gas & Electric Comp an PRG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

2. Manufactured tr (irme and addsrea of pidicasw)
3. Location of installah1on Diablo Canyon Power Plant Unit 92 P.O. Box 56, Avfla Beach, CA. 94354 (USA-(Tvine and aektieisi
4. Iype See Supplemental Page 3 See Supplemental Page 3 See Supplemental page 3 N/A 2009 (drawing no.)

(n*qeter.ll peo_ no.)

strel g oOrnlh (O)N)

(year Ibaki

5. ASKM Code,,ection III, Division 1 2001 2003 1

None i

loiS

( J, dd,*nsda1d

)

(1asm)

(Code rose no.)

U..Falricaled in amcordance with Corst. Spec. (Div. 2 only N/A Ilevision N/A Date N/A (noj

7. Remarks Fabrication performed in accordance with AREVA NP Inc., Certified Design Specification 08-9025240-003 with the exception of the Preservice examination, section 6.14, (performed by AREVA) and per Drawing 9023469E Rev. 006.

.1. Norn. lhickcaŽ,.

Min. design thickness 7,0 Diornelor ID _ --

_Lengithoverall 1S8.291" 9, When applicable, Certificate Holder's Data Heporis are attached lar each itemr of this report.

Paii ot Appurrtenance teilNamber 0 CC/0C0G2-CRcMHU01

()CC/DC002-CIRDMHUD2 13-CC/DCOO1-CIRDIVHU06 cc/ocoo2-cROM1,uo14 thru 06 CCIDC0O2-CRDMHU81-

15)

CC/D0c02-CR0IMlU08 7)CC/DC002-CRDMHU09 CC/DC002.CR0MHU82 CC/DCOO2-CRDMVHU1S (10) q!3002-CROMMU16 (I)CC/DCODI-CROMMU22 CC/trC002-CRoM~HU30thru 40 Nalional Board No-is Numerical Oider N/A N/A N/A N/A Par or Appurtrnaricu Serial Number N atio nal Bowic No.

in Niirnrie r Ort0 dor N/A N/A N/A N/A N/A N/A N/A N/A (20)

I28)

(33) 134)..

13PQ __

(37) ___________-

r131 CC/DCoo1-CRDM HU46 N/A CC/DCO02-CRDMHU65 thru 73

_N__A.

(16) CC/DCOO2-CROMHU82 thru 4 N/A (171 CC70C002-CRDMHU86 trN/A (18) CC/DC002-TCU74 thru 77 N/A

('a.) cc/DC002-TCU79 N/A (20__1 N/A 121)----------.................

(21)

'23)___

124)

,'25).

138)

(39)}

(401 __

(41)

(4?)

(43)

(44)

(45)

(46)

(47)

(4--)

(49)

70. D,.csigrr pressure 2485 PSIG

.Te5graime 650 Deg. F

  • Hydro..ist pies5(ile 3111 PSIG at lemp. 73.S De&. IF iwhen eprikstbie)
  • SuppiomeniJ info*imali0,r nm Ptei t(urm ot lists, sketches, er drawings may ba-us-d provided- (1) size is 8/2 " 11, (2) infuimlion in iterns2 and 3 on this Dala Repon rt is included on each sheet; and (3) each sheet i* nnubered and the number of.lirets is recorded at he top of thisforrn.

(011,00}

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

B&W QADP Section IX Page 3 FORM N-2 (Back -

Pg. 2 of 3_I Certificate HOlder's Serial Nos. 7OO-016852 Unittirough ___

N/A CERTIRCATION OF DESIGN Larry W. Davis P.F. Stale California Reg.

M33472 Design specifications ceitiied b___m____________.___._

(Pr7E N.

Stticebl M33816 Design reporlt cerlified by......

_.U_

E.Ki i...

_E.

State

_C__E-lifornla Reg. no.

M

(,*han a~pkhnaIe)

CERTIRCATE OF COMPLIANCE We cnrlity tat 1ha slatetrments made in ihis repolt are ocorrect and that this (these) Re.placement Reactor Vessel Closure Head conforms lo-31h. rules of coristr jcr ion or (he ASME Code,Section III, Divisimo 1.

NPT Certilicale I' Authorization No, N-3192-2 Expires MQ,,

4,20 at ___

Nanrm Babcock & Wilcox Nuclear Operations Signed (NPT Cerikd.ate Holdce) ta lho md

-es.n tat.)

CERTIRCATE OF INSPECTION t, theundcesigned, holding a valid t;ommission issued by 1.e National Board of Roiler and Pressure Vessel Inpectors and the State or Province nf

/AL".

and employed by L

ot-__

have inspected these items described in this Data Report on..

a -7 best ot my knowledge and belief, the Certificate Holder has labricaled these parts oi appurtenances in aurtordance with the ASME Code,Section II, Division 1. Each part listed has been authorized Iar stamping on the date shown above, By signing this cerlificate npirhe" the inspector nor his employer makes any warnanly, expressed or implied, concerning the equipment desi.rihed in this Dala Report. Furthermoro, neither the inspector nor his employer shall be liable in any manner for any personal injuiy or property damage or loss of any kind arising from or co,,nected with Ihis inspe.

Date Signed om s

1/ ~uionr~.agrnpeco~Moteioal Bd, O~i. andrs~or.-nm0li and Satae OF groCV.

arid no.)

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

B&W QADP Section IX Page 4 CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. 3_ of 3 Certificate Holder's Serial Nos., 700-0168-52 Unit #2 through N/A

1. Manufactured and certified by Babcock & Wilcox Nuclear Operations Group, Inc.

1400 Old Highway 69 South MI. Vernon. Indiana 47620 (Name and address of Certificate Holder)

2. Manufactured for Pacific Gas & Electric Company (PG&E) 77 Bcale Street. San Francisco CA 94105 (USA)

(Name and address of Purchaser)

3. Location of Installation Diablo Canyon Power Plant Unit #2 P.O. Box 56. Avila Beach, CA. 94354 fUSA)
4. Component or Part Part S/N 700-0168-52 Unit #2
5.

2009 (Year built)

NIA (CRN)

N/A (Nati Board No.)

Data Items by Line No.

4 Drawings No. 9023469E Rev. 006 Description Material Spec No.

Min. Tensile Strength Closure Head Forging SA 508 Grade 3 Class 1 80 ksi Lifting Lugs SA 533 Grade 2 Class 2 90 ksi IHA Support Lugs SA 533 Grade B Class 2 90 ksi Vent Nozzle SB 166 UNS N06690 92.08 ksi RVLIS Nozzle SB 166 UNS N06690 92.08 ksi VentRVLIS 90 deg. Elbow SA 403 Grade 304/304L 87 ksi Vent & RVLIS Pipe SA 376 TP 304 70 ksi Vent Flow Restrictor SA 479 Type 304/304L 87ksi At 68 dog. F At 650 Deg. F ILH Nozzles SA 479 Type 304/304L 75 ksi 59.2 kSi SB 167 UNS N06690 85 ksi 80 ksi Thermocouple Nozzles SA 479 Type 304/304L 75 kis 56.7 ksi SB 167 UNS N06690 85 ksi 80 ksi Date Name &4A) dw---

Signed (Certificate Holder)

.*uthorVed representative)

Date I P Signed._.t

      • n Commissions r

[Nat'l Board (Inc. Endorsements). State, Province and NoI AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

B&W QAIDP Section VII Page 890 CORRECTED FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL COPY NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code Section III 40 0 0 0 08 Not to Exceed One Day's Production Pg. 1 of 4 f

1. Manufactured and certified by AREVA NP Usine de Chalon/Saint Marcel (Name and address of Certificate Holder)

Zone Industrielle et Portuaire Sud - 71380 SAINT MARCEL - FRANCE

2. Manufactured for PACIFIC GAS& ELECTRIC COMPANY (PG&E)

(Name and address of Purchaser) 77 Beale Street, San Francisco, CA 94105, USA

3. Location of Installation Diablo Canyon Power Plant Unit 2, P.O. Box 56, Avila Beach, CA 94354, USA
4. Type (See supplementary pages 3 & 4)

N/A 2008 (drawing no.)

(matl spec no.)

(tensile strength)

(CRN)

(year built)

5. ASME Code,Section III, Division 2001 Addenda through 2003 1

N/A (edition)

(addenda)

(class)

(code case no.)

6. Fabricated In accordance with Const. Spec. (Div 2 only)

N/A Revision

/

Date

/

(no.)

7. Remarks:

Integrated Latch Housings (ILH) were welded onto CRDM nozzles by AREVA NP St Marcel.

ILH will be hydro-tested with the Replacement Reactor Vessel Closure Head.

CC/DC002 - CRDMHU83, CRDMHU84 and CRDMHU86 are spare parts. If they are fitted on the head, their length will be modified to the length of the ILH they will replace.

8. Nom. Thickness (in.)

N/A Min. des thickness (in.)

0.622" Dia. ID (ft & in.)

2.750" Length overall (ft & in.) (See supplementary pages 3 & 4)

9. When applicable, Certificate Holders' Data Reports are attached for each item on this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No.

Serial Number Board No.

in Numerical Order in Numerical Order

1. CC/DC002 - CRDMHU01 N/A
27. CC/DC002 - CRDMHU49 N/A
2. CC/DCO02 - CRDMHU04 N/A
28. CC/DC002 - CRDMHU5O N/A
3. CC/DC002 - CRDMHU05 N/A
29. CC/DC002 - CRDMHU51 N/A
4. CC/DC002 - CRDMHU06 N/A
30. CC/DC002 - CRDMHU52 N/A
5. CC/DC002 - CRDMHU08 N/A
31. CC/DC002 - CRDMHU53 N/A
6. CC/DC002 - CRDMHU09 N/A
32. CC/DC002 - CRDMHU54 N/A
7. CC/DC002 - CRDMHU15 N/A
33. CC/DC002 - CRDMHU55 N/A
8. CC/DC002 - CRDMHU16 N/A
34. CC/DC002 - CRDMHU56 N/A
9. CC/DC002 - CRDMHU30 N/A
35. CC/DC002 - CRDMHU57 N/A
10. CC/DC002 - CRDMHU31 N/A
36. CC/DC002 - CRDMHU58 N/A
11. CC/DC002 - CRDMHU32 N/A
37. CC/DC002 - CRDMHU59 N/A
12. CC/DC002 - CRDMHU33 N/A
38. CC/DC002 - CRDMHU60 N/A
13. CC/DC002 - CRDMHU34 N/A
39. CC/DC002 - CRDMHU61 N/A
14. CC/DC002 - CRDMHU35 N/A
40. CC/DC002 - CRDMHU66 N/A
15. CC/DC002 - CRDMHU36 N/A
41. CC/DC002 - CRDMHU67 N/A
16. CC/DC002 - CRDMHU37 N/A
42. CC/DC002 - CRDMHU68 N/A
17. CC/DC002 - CRDMHU38 N/A
43. CC/DC002 - CRDMHU69 N/A
18. CC/DC002 - CRDMHU39 N/A
44. CC/DC002 - CRDMHU70 N/A
19. CC/0C002 - CRDMHU40 N/A
45. CC/DC002 - CRDMHU71 N/A
20. CC/DC002 - CRDMHU42 N/A
46. CC/DC002 - CRDMHU72 N/A
21. CC/DC002 - CRDMHU43 N/A
47. CC/DC002 - CRDMHU73 N/A
22. CC/DC002 - CROMHU44 N/A
48. CC/DC002 - CRDMHU61 N/A
23. CC/UC002 - CRDMHU45 N/A
49. CC/DC002 - CRDMHU82 N/A
24. CC/DC002 - CRDMHU46 N/A
50. CC/DC002 - CRDMHU83 N/A
25. CC/DC002 - CRDMHU47 N/A
51. CCiDC002 - CROMHU84 N/A
26. CC/DC002 - CRDMHU48 N/A
52. CC/DC002 - CRDMHU86 N/A
10. Design Pressure 2485 pslg Temp. 650 Deg. F Hydro.Test Pressure @ Temp NO (refer to item 7)

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

  • A I B&W UAUIP Section VII Page 891 CORRECTED qCOPY FORM N-2 (Back - Pg 2 of 4) 400 0009 CC/DCO02 - CRDMHUO1, CRDMHU04 to CRDMHU06, CRDMHU08, CRDMHU09, Certificate Holders' Serial Nos CRDMHU15, CRDMHU16, CRDMHU30 to CRDMHU40, CRDMHU42 to CRDMHU61, CRDMHU66 to CRDMHU73, CRDMHU81 to CRDMHU84, CRDMHU86 CERTIFICATION OF DESIGN Design Specifications Certified by Larry W. DAVIS P.E. State CA Reg. No.

M-33472 Design Report Certified by Harry HARRISON III P.E. State CA Reg. No.

M-33812 CERTIFICATE OF COMPLIANCE We Certify that the statements made in this report are correct and that this (these)

CRDM adauters conforms to the rules of construction of the ASME Code,Section III Division 1 NPT Certification of Authorization No.

N-2772 Expires:

Jan.29,2009 Date Name AREVANP Signed CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of GEORGIA and employed by HSBCT of Hartford / CT have inspected these items described in this Data Report on "I 2oo>.

and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or Appurtenances in accordance with the ASME Code,Section III, Division 1. Each Part has been authorized for stamping on the date shown above; By signing this certificate, neither the Inspector nor his Employer makes any warranty expressed or implied concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his Employer shall be liable for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date;11+/-',Ve.. 1=

SignedQ

-c,:

Commissions A. ?J.

74-F6" (Authorized Nuclear Inspector)

(Nat'l Board Endsmts, State or Prov. and no.)

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

B&W QADP Section VII Page 892 AO0 0010 CORRECTED COPY CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. 3 of 4 CCiDC002

CRDMHU01, CRDMHU04 to
CRDMHU06, CRDMHU08,
CRDMHU09, CRDMHU15,
CRDMHU16, CRDMHU30 to
CRDMHU40, Certificate Holder's Serial Nos.

,CRDMHU42 to CRDMHU61, CRDMHU66 to CRDMHU73, CRDMHU81 to CRDMHU84, CRDMHU86

1. Manufactured and certified by AREVA NP Usine de Chalon/Saint Marcel (Name and address of Certificate Holder) 77n Beale Stree~ t, SanFrancisco Cud-7~A 94105, USAR.I-FAJ
2. Manufactured for -PACIFIC GAS & ELECTRIC COMPANY (PG&E)

(Name and address of Purchaser) 77 Beale Street, San Francisco, CA 94105, USA

3. Location of Installation Diablo Canyon Power Plant Unit 2, P.O. Box 56, Avila Beach, CA 94354, USA
4. Component or Part CRDM ADAPTER FOR REACTOR VESSEL CLOSURE HEAD
5.

2008 (Year built)

N/A (CRN)

N/A (Natl Board No.)

Data Items by Line No.

4 Drawings No.

Rev.

02-9040741 E 000 02-9044744D 000 BUHPDC/NCCO312 B

BUMPDC/NCC0401 A

BUHPDC/NCC0513 C

BUHPDC/NCC0514 F

Material Spec. No.

ASME material CRDM nozzles SB -167 UNS N06690 CRDM flanges with ILH SA-182 Grade F 304 Tensile Strength (min. SU - Note 1)

At 68°F At 650°F CRDM nozzles 85 ksi 80 ksi CRDM flanges with ILH 70 ksl 59.2 ksi Note 1 : Min. tensile strength value SU from ASME Code,Section III, Division 1, Appendices, Table 1-3.0 which refers to Section II, Part D, Subpart 1, Table U.

Date c 2,3 A,

Name AREVA NP Signed C-V"4.bJ- ' ;4E" l" (Certificate Holder)

Date Zý'Sewit.TP.,

(Authorized representative)

Signed Commissions AN.

G(A C74-.

(Authorized Nuclear Ilspector) i[NatI Board (Inc. Endorsements), State, Province and No]

AREVA NP Inc. QADP Doc. Id. 23-91165 0-00-Attichmin-t D"

B&W QADP Section VII Page 893 400 0011 CORRECTED COPY CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. _4C of _4_

CC/DC002

-CRDMHU01, CRDMHU04 to

CRDMHU06, CRDMHU08, CRDMHU09, :CRDMHU15,
CRDMHU16, CRDMHU30 to
CRDMHU40, Certificate Holder's Serial Nos.

CRDMHU42 to CRDMHU61, CRDMHU66 to CRDMHU73, CRDMHU81 to CRDMHU84, CRDMHU86

1. Manufactured and certified by AREVA NP Usine de Chalon/Saint Marcel (Name and address of Certificate Holder)

Zone Industrielle et Portuaire Sud - 71380 SAINT MARCEL - FRANCE

2. Manufactured for PACIFIC GAS & ELECTRIC COMPANY (PG&E)

(Name and address of Purchaser) 77 Beale Street, San Francisco, CA 94105, USA

3. Location of Installation Diablo Canyon Power Plant Unit 2, P.O. Box 56, Avila Beach, CA 94354, USA
4. Component or Part CRDM NOZZLE ADAPTOR FOR REACTOR VESSEL CLOSURE HEAD
5.

2008 N/A N/A (Year built)

(CRN)

(Natl Board No.)

Data Items by Lne No.

8 Serial number Length overall.

CRDMHU01 6' 7.069" CRDMHU04,05 6' 9.200" CRDMHU06,08,09,81 6' 11.121" CRDMHU82,15,16 7' 2.988" CRDMHU30,31,32,33,34,35,36,37 7' 8.017, CRDMHU38,39,40 7' 11.181" CRDMHU42,43,44,45,46,47,48,49 8' 0.265" CRDMHU50,51,52,53 8' 1.365" CRDMHU54,55,56,57,58,59,60,61 8' 3.617" CRDMHU66,67,68,69,70,71,72,73 8' 10.866" CRDMHU83,84,86 9' 6.099" (refer to item 7) 0 Date 0 q X '

Name AREVA NP Signed E

(Auh*orized representative)

.4...

Ii~J euI Date al-2

'L5dT.HEP1e Signed

.C C Commissions A.N.

A -'-(67L-(Authorized Nuclear Ihspector)

[Natl Board (Inc. Endorsements), State, Province and No]

AI*EVA-N-nc:.-ADPDoc. Id. 23-9116580-001 Attachment D

B&W QADP Section VII Page 102 FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code Section III Not to Exceed One Day's Production CORRECTED COPY 00 0008 Pg. 1 of 4

1. Manufactured and certified by AREVA NP Usine de Chalon/Saint Marcel (Name and address of Certificate Holder)

Zone Industrielle et Portuaire Sud - 71380 SAINT MARCEL - FRANCE

2. Manufactured for PACIFIC GAS & ELECTRIC COMPANY (PG&E)

(Name and address of Purchaser) 77 Beale Street, San Francisco, CA 94105, USA

3. Location of Installation Diablo Canyon Power Plant Unit 2, P.O. Box 56, Avila Beach, CA 94354, USA
4. Type (See supplementary pages 3 & 4)

N/A 2008 (drawing no.)

(marl spec no.)

(tensile strength)

(CRN)

(year built)

5. ASME Code, Section Il1, Division 2001 Addenda through 2003 1

N/A (edition)

(addenda)

(class)

(code case no.)

6. Fabricated in accordance with Const. Spec. (Div 2 only)

N/A Revision

/

Date

/

(no.)

7. Remarks:

- Inteorated Latch Housinas (OLHI were welded onto CRDM nozzles bv AREVA NP St Marcel.

- ILH will be hydro-tested with the Replacement Reactor Vessel Closure Head.

- ILH CC/DC001 - CRDMHU06, CRDMHU22 and CRDMHU46 were initially assigned to Diablo Canyon Power Plant Unit I replacement head, and have been transferred to Diablo Canyon Power Plant Unit 2 replacement head.

8. Nom. Thickness (in.)

N/A Min. des thickness (in.)

0.622" Dia. ID (ft & in.)

2.750" Length overall (ft & in.)

(See supplementary pages 3 & 4)

9. When applicable, Certificate Holders' Data Reports are attached for each item on this report:

Part or Appurtenance National Part or Appurtenance

-National Serial Number Board No.

Serial Number Board No.

in Numerical Order in Numerical Order_

1. CC/DC002 - CRD MHU02 N/A
2. CC/DCOO1 - CRD MHU06 N/A
3. CC/DCOO1 - CRDMHU22 N/A
4. CC/DCOO1 - CRDMHU46 N/A
10. Design Pressure 2485 psig Temp. 650 Deg. F Hydro.'est Pressure @ Temp NO (refer to item 7)

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

B&W QADP Section VII Page 103 GURRECILL)

CCPY FORM N-2 (Back - Pg 2 of 4)

A 00 0009 CC/DC002 - CRDMHU02 Certificate Holders' Serial Nos CC/DCOO0

- CRDMHU06, CRDMHU22, CRDMHU46 CERTIFICATION OF DESIGN Design Specifications Certified by LarryW. DAVIS P.F. State CA Reg. No.

M-33472 Design Report Certified by Harry HARRISON III P.E. State CA Reg. No. M-33812 CERTIFICATE OF COMPLIANCE We Certify that the statements made in this report are correct and that this (these) CRDM adaoters conforms to the rules of construction of the ASME Code,Section III Division 1 N-2772 U

NPT Certification of Authorization No.

DateA &a*L3.*

Name Pynirpq-Jan.29,2009 AREVA NP Signed *

.(f.

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NY' and employed by HSBCT of Hartford / CT have inspected these items described in this Data Report on and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or Appurtenances in accordance with the ASME Code,Section III, Division 1. Each Part has been authorized for stamping on the date shown above.

By signing this certificate, neither the Inspector nor his Employer makes any warranty expressed or implied concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his Employer shall be liable for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date _C_'____.__

igned Commissions (Authori uc ar Inspector)

(Nat'l Board Endsmts, State or Prov. and no.)

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

B&W QADP Section VII Page 104 CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III LUHNm-;IWu COPY Pg. 3 of 4 A 00 0010 Certificate Holder's Serial Nos.

CC/DC002 - CRDMHUO2 CC/DC001 - CRDMHU06, CRDMHU22, CRDMHU46

1. Manufactured and certified by AREVA NP Usine de Chalon/Saint Marcel ri (Name and address of Certificate Holder)

Zone Industrielle et Portuaire Sud - 71380 SAINT MARCEL - FRANCE

2. Manufactured for PACIFIC GAS & ELECTRIC COMPANY (PG&E)

(Name and address of Purchaser) 77 Beale Street, San Francisco, CA 94105, USA

3. Location of Installation Diablo Canyon Power Plant Unit 2, P.O. Box 56, Avila Beach, CA 94354, USA
4. Component or Part CRDM ADAPTER FOR REACTOR VESSEL CLOSURE HEAD
5.

2008 N/A N/A (Year built)

(CRN)

(Natt Board No.)

Data Items by Line No.

4 Drawings No.

Rev.

02-9040741 E 000 02-9044744D 000 BUHPDC/NCC0311 B

BUHPDC/NCC0312 B

BUMPDC/NCC0412 A

BUMPDC/NCC0401 A

BUHPDC/NCC0503 C

BUHPDC/NCC0513 C

BUHIPDC/NCC0504 D

BUHPDC/NCC0514 F

Material Spec. No.

ASME material CRDM nozzles SB -167 UNS N06690 CRDM flanges with ILH SA-182 Grade F 304 Tensile Strength (min. SU - Note 1)

At 68*F At 650°F CRDM nozzles 85 ksi 80 ksi CRDM flanges with ILH 70 ksi 59.2 ksi Note 1 : Min. tensile strength value SU from ASME Code,Section III, Division 1, Appendices, Table 1-3.0 which refers to Section II, Part D, Subpart 1, Table U.

Date 0

Name AREVA NP Signed C. * *

(ce-

  • Date OCI.
  • 'J (Certificate Hol Signed C"w Commissions (Authorized rspector) der)

(Authorized representative) 8 VY*_2 0,F

[Nat'l Board (Inc. Endorsements), State, Province and No]

AREVA NP Inc.,QADP Doc. Id. 23-9116580-001 Attachment D

B&W QADP Section VII Page 105 CUHHECTED CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET COPY As Required by the Provisions of the ASME Code Section III Pg. 4 of 4 00 0011 Certificate Holder's Serial Nos.

CC/DC002 - CRDMHU02 CC/DC001 - CRDMHU06, CRDMHU22, CRDMHU46

1. Manufactured and certified by AREVA NP Usine de Chalon/Saint Marcel (Name and address of Certificate Holder)

Zone Industrielle et Portuaire Sud - 71380 SAINT MARCEL - FRANCE

2. Manufactured for PACIFIC GAS & ELECTRIC COMPANY (PG&E)

(Name and address of Purchaser) 77 Beale Street, San Francisco, CA 94105, USA

3. Location of Installation Diablo Canyon Power Plant Unit 2, P.O. Box 56, Avila Beach, CA 94354, USA 0
4. Component or Part CRDM NOZZLE ADAPTOR FOR REACTOR VESSEL CLOSURE HEAD 2008 N/A N/A (Year built)

(CRN)

(NaVI Board No.)

Data Items by Line No.

8 Serial number Length overall CC/DC002 - CRDMHU02 6' 9.200" CC/DC001 - CRDMHU06 6' 9.200" CC/DC001 - CRDMHU22 7' 2.988" CC/DC001 - CRDMHU46 7' 11.181" i

Date A 3 1-Name AREVA NP Signed (9. -*f 49 (ZC (Authorized representative)

(Certificate Holder)

Date

(.L 9 ~

Signed (Authorized N arnspector)

IVY f2-AT Commissions

[Natl Board (Inc. Endorsements), State, Province and No]

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

(PG&E, Agreement No. 3500720877)

QADP 23-9094542-001, Page 60 of 1230 B&W QADP Section VII Page 4150 CO FORM N-2 CERTIFICATE HOLDERS' DATA REPORT FOR IDENTICAL NUCLEAR PARTS AND APPURTENANCES As Required by the Provisions of the ASME Code Section III Not'to Exceed One Day's Production A 0 0

'RRECTED

.Copy 0008 Pg. 1 of 3

1. Manufactured and certified by AREVA NP Usine de Chalon/Saint Marcel (Name and address of Certificate Holder).

Zone Industrielle et Portuaire Sud - 71380 SAINT MARCEL - FRANCE

2. Manufactured for PACIFIC GAS & ELECTRIC COMPANY (PG&E)

(Name and address of Purchaser) 77 Beale Street, San Francisco, CA 94105, USA

3. Location of Installation Diablo Canyon Power Plant Unit 2, P.O. Box 56, Avila Beach, CA 94354, USA
4. Type (See supplementary page 3)

N/A 2008 (drawing no.)

(matl spec no.)

(tensile strength)

(CRN),

(year built)

5. ASME Code,Section III, Division 2001 Addenda through 2003 1

N/A (edition)

(addenda)

(class)

(code case no.)

6. Fabricated in accordance with Const. Spec. (Div 2 only)

N/A -

Revision Date (no.)

7. Remarks:

- CETNA flanges were welded onto nozzles by AREVA NP St Marcel.

- CETNA will be hydro-tested with the Replacement Reactor Vessel Closure Head.

- CC/DCth 2 - TCU1 01 and TCU1 02 are spare parts. If they are ftieed on the head, their length will be modified to the length of the CETNA nozzle they will replace.

8. Nom. Thickness (in.)

N/A Min. des thickness (in.)

0.622" Dia. ID (ft & in.)

2.750" Length overall (ft & in.)

(See supplementary page 3)

9. When applicable, Certificate Holders' Data Reports are attached for each item on this report:

Part or Appurtenance National Part or Appurtenance National Serial Number Board No.

Serial Number Board No.

in Numerical Order in Numerical Order

1. CC/DC002 - TCU74 N/A
2. CC/DC002 - TCU75 N/A
3. CC/DC002 - TCU76 N/A
4. CC/DC002 - TCU77 N/A 51 CC/DC002 - TCU79 N/A
6. CC/DC002 - TCU101 N/A
7. CC/DC002 - TCU 102 N/A

~1~

I

+/-

I

10. Design Pressure 2485 psig Temp. '_650

. Deg. F Hydro.Test Pressure* @ Temp NO (refer to item 7ý AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

K (PG&E, Agreement No. 3500720877)

QADP 23-9094542-001, Page.61 of 1230 B&W QADP Section VII Page 4151 CORRECTED COPY FORM N-2(Back-Pg2of 3) 400 0009 CC/DC002 - TCU74, TCU75, TCU76, Certificate Holders' Serial Nos TCU77, TCU79, TCU101, TCU102 CERTIFICATION OF DESIGN Design Specifications Certified by Wells D. FARGO P.E. State CA Reg. No.

M-31209 Paul BLKESLE CAM-25887 Design Report Certified by Paul B. BLAKESLEE P.E. State CA Reg. No.

M-25887 CERTIFICATE OF COMPLIANCE We Certify that the statements made in this report are correct and that this (these) CETNA adaDters conforms to the rules of construction of the ASME Code,Section III Division 1 NPT Certification of Authorization No.

N-2772 Expires:

Jan.29,2009 Date o9ol 4 Name AREVANP Signed C.

rJ.'

E CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of.AI*.

and employed by HSBCT of Hartford/ CT have inspected these items described in this Data Report on

_1 O'?2 and state that to the best of my knowledge and belief, the Certificate Holder has fabricated these parts or Appurtenances in accordance with the ASME Code,Section III, Division 1. Each Part has been authorized for stamping on the date shown above.

By signing this certificate, neither the Inspector nor his Employer makes any warranty expressed or implied concerning the equipment described in this Data Report. Furthermore, neither the Inspector nor his Employer shall be liable for any personal injury or property damage or loss of any kind arising from or connected with this inspection.

Date (f"

  • f

-- Signed Commissions ___.-_--______

(Authoriz aes spector)

(Nat'l Board Endsmts, State or Prov. and no.)

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

(PG&E, Agreement No. 3500720877)

QADP 23-9094542-001, Page B&W QADP Section VII Page 4152 CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III CC/DC002 - TCU74, TCU75, TCU76, Certificate Holder's Serial Nos. TCU77, TCU79, TCU101, TCU102 62 efji3r-tr. I t.U COPY AP0 00103 Pg. 3 of 3

1. Manufactured and certified by AREVA NP UsineCd Chalon/Saint Marcel (Name and address of Certificate Holder)

Zone Industrielle et Portuaire Sud - 71380 SAINT MARCEL - FRANCE

2. Manufact ured for-PACIFIC GAS & ELECTRIC COMPANY (PG&E)

(Name and address of Purchaser) 77 Beale Street, San Francisco, CA 94105, USA 0

3. Location of Installation Diablo Canyon Power Plant Unit 2, P.O. Box 56, Avila Beach, CA 94354, USA
4. Component or Part CETNA ADAPTER FOR REACTOR VESSEL CLOSURE HEAD
5.

2008 N/A N/A (Year built)

(CRN)

(Nat'l Board No.)

Data Items by Line No.

4 Drawings No.

Rev.

02-9041346D 003 02-9052027C 001 BUHPDC/NCC0312 B

BUMPDC/NCC0522 B

BUHPDC/NCC0576 B

BUHPDC/NCC0577 F

Material Spec. No.

ASME material CETNA nozzles SB -167 UNS N06690 CETNA flanges SA-479 Grade F 304/304L Tensile Strength (min. SU - Note 1)

At 68*F At 650°F CETNA nozzles 85 ksi 80 ksi CETNA flanges 70 ksi 56.7 ksi Note 1 : Min. tensile strength value SU from ASME Code,Section III, Division 1, Appendices, Table 1-3.0 which refers to Section II, Part D, Subpart 1, Table U..

8 Serial number Length overall TCU74, 75, 76, 77, 79 6' 1.920' TCU101, 102 6' 6.459" Date AO o.5 AO Name AREVA NP Signed (I."Z o

-t 4I E V Date (Certificate Holder)

(Authorized representative)

Signed 4

Commissions

/V___

V_

(Authoriz le Inspector)

[Nat'l Board (Inc. Endorsements), State, Province and No]

AREVA NP Inc. QADP Doc. Id. 23-9116580-001 Attachment D

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 p9.p.1 of 3__

1. Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

3. Location of installation Diablo Canyon Power Plant Unit #2 P.O. Box 56, Avila Beach, CA. 94354 (USA)

Reactor Vessel Head Vent (name and address)

4. System identification System (RVHVS) Sub Assembly I 908283r,001 02-9082836E Rev 003 N/A NIA 2009 (system name)

(Cert. Holier's serial no.

(drawing no.)

(CRN)

(National ed. no.)

(year installed)

5. ASME Code,Section III, Division 1 2001 2003 Class 1 N-411-1 (edition)

(addenda date)

(class)

(Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (b) Name of (a) Comp. or Appurt.

Certificate Holder (c) Serial No.

(d) CRN No.

(e) National Bd. No.

N/A N/A N/A N/A N/A Piping and part installation (a) Piping or Part (b) Name of Subassembly Certificate Holder (c) Serial No.

(d) CRN No.

(e) National Bd. No.

N/A N/A N/A N/A N/A Support installation (f) Year Built N/A (f) Year Built-Parts N/A On ly (b) Name of la) SupoOrt No.

Certificate Holger N/A N/A Additional material excluding welding material

.(a) Name of Manufacturer (d) Design Rept./Load (c) Serial No.

Capac. Data Sheet (e) CRN No.

(f) National Bd. No.

(g) Year Built N/A N/A N/A N/A N/A (b) Material Spec. No.

(c) Dimensions-Overall See sheet 3 See sheet 3 See sheet 3

8. Installation in accordance with Procedure or Drawing No.

Prepared by 50-9073946 Rev 000 as modified by 30-9111840 Rev 000 and 30-9111840 Rev 001 DH Wood 02-9082836E Rev 003 DH Wood 02-9046308D Rev 007, and 02-9046310O Rev 005 DH Wood

9. Hydrostatic test pressure 3107 PSIG at temp.

67F System design pressure 2485 PSIG at temp.

650*F

10. Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial number in lieu of stamping

  • Supplemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 81/2 x 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

9082836-001 Certificate Holder's Serial No.

CERTIFICATION OF DESIGN FOR PIPING SYSTEM Design information on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design specification certified by Larry Davis P.E. State CA Reg. no.

M33472 Design report certified by James Richard Harrington.

RE. State CA Reg. no.

M33811 Design conditions of pressure piping 2485ps Temp.

650 F.

CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date N/A Name N/A Signed N/A (N or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Report on N/A and K

state that to the best of my knowledge and belief, the Certificate of Authorization Holder has performed this installation in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any Warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A--

Date Signed N/A Commissions N/A (Authorized Nuclear Inspector)

[Nat'l. 8d. Iincl. endorsements) and state or prey. and no.]

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Certificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement.

We certify that the statements made by this report are correct and that the piping system conforms to the rules for construction of the ASME Code, Section ItI, Division 1.

N Certificate of Authorization No.

N-1650 Expires June 12, 2012 Date

/

62-Name AREVA NP Inc.

Signed Vi/

    • J *

(N Certificate Holder)

' *authozed representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of

Virginia, and.employed by HSB-CT of Hartford, CT have inspected the piping system described in this Data Report on Zo F and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping system in accordance with the ASME Code, Section II1, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage' or a loss of any kind arising from or connected with this inspection.

Date 7 0 9 Signed

ýCommissions 55 BV,15

,i /

l AuthorizedNu*earlnsp cctor)

INationail d. Uci. endorsements), and state or pr... and no.)

(09/06)

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg._.3 of 3

)082836-001 Certificate Holder's Serial Nos.

S/N Attachment to ASME FORM N-5 for RVHVS Subassembly 1,

1. Installed and Certified by, AREVA NP, 3315 Old Forest Rd, Lynchbur-q VA, 24501
4. System Identification: RVHVS Subassembly 1, S/N 9082836-001, Drawing 02-9082836E Rev 003, CRN: N/A, National Board no: N/A, Year Built: 2009.

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, ANDAPPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of 3

1.

2.

3.

4.

5.

6.

7.

Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)

Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

Location of installation Diablo Canyon Power Plant Unit #2 P.O. Box 56, Avila Beach, CA. 94354 (USA)

Reactor Vessel Head Vent (name and address)

System identification System (RVHVS) Sub Assembly 3 9082836-003 02-9082836E Rev 003 N/A N/A 2009 (system name)

(Cerl. Holder's serial no.

(drawing no.)

(CRN)

(National Bd. no.)

(year Installed)

ASME Code,Section III, Division 1 2001 2003 class 1 N-411-1 (edition)

(addenda date)

(class)

(Code Case no.)

N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)

Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (b) Name of (a) Comp. or Appurt.

Certificate Holder (c) Serial No.

1' 1878 Globe Valve Flowserve Corp., 1900 S. Sanders 86BMY, 87BMY, 88BMY St.; Raleigh NC, 27603

89BMY, 3/8" 3HN Valve Swagelok Comp., 29500 Solon YU7348-001-0001 Rd., Solon, OH 44139 YU7348-001-0002 Piping and part installation (a) Piping or.Part (b) Name of Subassembly Certificate Holder (c) Serial No.

N/A NIA N/A Support installation (d) CRN No.

N/A (d) CRN No.

N/A (e) National Bd. No.

N/A (f) Year Built N/A (f) Year Built-Parts N/AOnly (e) National Bd. No.

N/A (a) Su3oDort No.

N/A (b) Name of Certificate Holder N/A (d) Design Rept./Load (c) Serial No.

Capac. Data Sheet (e) CRN No.

if) National Bd. No.

(g) Year Built N/A N/A N/A N/A N/A Additional material excluding welding material (a) Name of Manufacturer See sheet 3 (b) Material Spec. No.

See sheet 3 (c) Dimensions-Overall See sheet 3

8. Installation, in accordance with Procedure or Drawing No.

Prepared by 50-9073946 Rev 000 as modified by 30-9111840 Rev 000 and 30-9111840 Rev 001 DH Wood 02-9082836E Rev 003 DH Wood 02-9046308D Rev 007, and 02-9046310D Rev 005 DH Wood 3107 PSIG 68T 2485 PSIG 650T

9. Hydrostatic test pressure at temp.

8'System design pressure at temp.

10. Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial number in lieu of stamping

. Supplemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 81/2 x 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and 03) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

Certificate Holder's Serial No.

9082836-003 CERTIFICATION OF DESIGN FOR PIPING SYSTEM AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design information on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at Design specification certified by Larry Davis P.E. State CA Reg. no.

M33472 James Richard Harrington.

M33811 Design report certified by P.E. State CA Reg. no.

Design conditions of pressure piping 2485 psi. Temp.

  • 650

°F.

CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date N/A Name N/A Signed N/A (N or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Report on N/A and state that to the best of my knowledge and belief, the Certificate of Authorization Holder has performed this installation in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date Signed N/A Commissions N/A (Authorized Nuclear Inspector)

[Nat'l. Bd. (incl. endorsements) and state or prov. and no.)

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Certificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement.

We certify that the statements made by this report are correct and that the piping system conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1650 Expires June 12, 2012

-9 Date

/ " 09 Name AREVA NP Inc.

Signed ieý (N Certificate Holderi (auth zied representative)

CERTIFICATE OF INSPECTION I, the undersivned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSB-CT of Hartford, CT have inspected the piping system described in this Data Report on and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping system in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date

?

Sign ed

  • ý Aem m

io ns 5656 ABN, VA, 105R

/

i (Authorized Nuclear Inspector)

(National Bd. (incl. endorsements), and state or prav. and no.)

(09/06)

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. 3 of 3 Certificate Holder's Serial Nos.

SIN 9082836-003 Certificate Holder's Serial Nos.

Attachment to ASME FORM N-5 for RVHVS Subassembly 3,

1. Installed and Certified by: AREVA NP, 3315 Old Forest Rd, Lynchburg VA, 24501
4. System Identification: RVHVS Subassembly 3, S/N 9082836-003, Drawing 02-9082836E Rev 003, CRN: N/A, National Board no: N/A, Year Built: 2009.

RVHVS SUB-ASSEMBLY 3 - SIN 9082836-003 y

MOverall Description Heat #

Dimensions 01.32x3 01.32x5.6 01.32x1 3.9 Energy and Process 1" SCH 160 SEAMLESS PIPE, SA-376 TP 01.32x5.6 9PC Corporation 304 HT# 39131 01.32x16.8 01.32x52.6 01.32x13.72 01.32x14.1 I

01.32x8.2 1

Energy and Process Corporation 1 6000# 900 SW ELBOW, SA-182 F304/L HT# 0528 01.94xl.19x1.19 3

Energy and Process HT#

Corporation 1"Xl"X1" 6000# SW TEE, SA-182 F304/L 537694 2.38xl.94x2.5 2

Energy and Process 1" R.F. FLANGE #1500 SW SCH 160 BORE, HT# 9387H 0588x1.62 Corporation SA-182 F347 THD (Nut) 2 Swagelok 3/8" SWAGELOK TO TUBE UNION UHA 05/8xl.5 PIN SS-600-6W, TYPE 316 SS (Body)

SJY (Nut) 2 Swagelok SWAGELOK END PLUG #SS-600-P-0010, RPU 03/8x.75 TYPE 316 SS (Body)

SWAGELOK 1" PIPE TO 3/8" TUBE 2

Swagelok ADAPTER P/N SS-16-MPW-A-6TSW, TYPE SWF 01.32xl.4 316 SS AR Energy and Process iTUBING Corporationces 0.373 X.121" TO.125" WALL, SA-479 TP HT# 30828 316/1L 03/8x41ong

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 pg. 1 of 3

1. Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

3. Location of installation Diablo Canyon Power Plant Unit #2 P.O. Box 56, Avila Beach, CA. 94354 (USA)

Reactor Vessel Level Indication (name and address)

4. System identification System (RVLIS) Sub Assembly 1 9091693-001 02-9091693E Rev 001 N/A N/A 2009 (system name)

ICert. Holder's serial no.)

(drawing no.)

(CRN)

(National Bd. no.)

(year installed)

5. ASME Code,Section III, Division 1 2001 2003 Class 1 N-411-1 (edition)

(addenda date) iclass)

- (Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (b) Name of (a) Comp. or Appurt.

Certificate Holder (c) Serial No.

N/A N/A N/A Piping and part installation (a) Piping or Part (b) Name of Subassembly Certificate Holder (c) Serial No.

N/A N/A N/A Support installation (d) CRN No.

(e) National Bd. No.

N/A N/A (f) Year Built N/A (f) Year Built-Parts (d) CRN No.

(a) National Bd. No.

Only N/A N/A N/A (a) Support No.

NIA (b) Name of Certificate Holder N/A (d) Design Rept./Load (c) Serial No.

Capac. Data Sheet (e) CRN No.

(f) National Bd. No.

(g) Year Built N/A N/A N/A N/A N/A Additional material excluding welding material (a) Name of Manufacturer See sheet 3 (b) Material Spec. No.

See sheet 3 (c) Dimensions-Overall See sheet 3

8. Installation in accordance with Procedure or Drawing No.

Prepared by 50-9073945 Rev 000 as modified by 30-9111839 Rev 000 and 30-9111839 Rev 001 DH Wood 02-9091693E Rev 001

.DH Wood 02-9048971D Rev 007 DH Wood 3107 PSI G 67' 2485 PSIG 650T

9. Hydrostatic test pressure at temp.

6FSystem design pressure at temp.

10. Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial number in lieu of stamping

  • Supplemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 8 t/2 X 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

Certificate Holder's Serial No.

9091693-001 CERTIFICATION OF DESIGN FOR PIPING SYSTEM Design information on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design specification certified by Larry Davis P.E. State CA Reg. no. M33472 James Richard Harrington.

M33811 Design report certified by P.E. State CA Reg. no.

Design conditions of pressure piping 2485 psi. Temp.

650

.°F.

CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date N/A Name N/A Signed N/A IN or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Report on N/A and state that to the best of my knowledge and belief, the Certificate of Authorization Holder has performed this installation in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date Signed N/A Commissions N/A (Authorized Nuclear Inspector)

[Nat'l. Bd. (inel, endorsements) and state or prov. and no.1 CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Certificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement.

We certify that the statements made by this report are correct and that the piping system conforms to the rules for construction of the ASME Code, Section 11, Division 1.

N Certificate of Aut orization No.

N-1650 Expires June 12, 2012 Dt

?

AREVA NP Inc.

Signed Date

_Name Signed___

(N Certificate Holder) k (authorizerreresentative)

CERTIFICATE OF-INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by H SB-C;T of Hartford, CT have inspected the piping system described in this Data Report on and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping system in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected wit this inspection.

Date "Signed Commissions 5656 ABN, VA, 105R (Authorized NucleTa* Inspector)

[National ad. indc. endorsementsi, and state or prov. and no.]

(09/06)

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. 3 of 3 Certificate Holder's Serial Nos.

SIN 9091693-001 Attachment to ASME FORM N-5 for RVLIS Subassembly 1,

1. Installed and Certified. by: AREVA NP, 3315 Old Forest Rd, Lynchburg VA, 24501 4..System Identification: RVLIS Subassembly 1, S/N 9091693-001, Drawingq 02-9091693E Rev 001, CRN: N/A, National Board no: N/A. Year Built: 2009.

RVLIS SUB-ASSEMBLY I - SIN 9091693-001 Overall Qty Manufacturer Description Heat #

Dier son Dimensions AR Energy and Process 1" SCH 160 SEAMLESS PIPE, SA-376 TP HT# 39131 23x4x1.315 Corporation 304 Heat Code 1

Energy and Process 1" 6000# 900 SW ELBOW, SA-1 82 F304/L D83 Corporation HT# 0528 1.94xl.19xl.19

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 pg. 1 of 3

1. Installed andcertified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

3. Location of installation Diablo Canyon Power Plant Unit #2 P.O. Box 56, Avila Beach, CA. 94354 (USA)

Reactor Vessel Level Indication 9091693-002 (name and address)

4. System identification System (RVLIS) Sub Assembly2 02-9091693E Rev 001 N/A N/A 2009 (system name)

(Cert. Holder's serial no.)

(drawing no.)

(CRN)

(National Sd. no.)

(year installed)

5. ASME Code, Section II1, Division 1 2001 2003 Class 1 N-411-1 (edition)

(addenda date)

(class)

(Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (b) Name of (a) Comp. or Appurt.

Certificate Holder (c) Serial No.

(d) CRN No.

(e) National Bd. No.

1" 1878 Y Globe Valve Flowserve Corporation 97BMY N/A N/A 1900 South Sanders S.

Raleigh NC, 27603 (f) Year Built 2009 Piping and part installation (a) Piping or Part (b) Name of (f) Year Built-Parts Subassembly Certificate Holder (c) Serial No.

(d) CRN No.

(e) National Bd. No.

Only N/A N/A N/A N/A N/A N/A Support installation (a) Support No.

N/A (b) Name of Certificate Holder N/A (d) Design Rept./Load (c) Serial No.

Capac. Data Sheet (e) CRN No.

(f) National Bd. No.

(g) Year Built N/A N/A N/A N/A N/A Additional material excluding welding material (a) Name of Manufacturer See sheet 3 (b) Material Spec. No.

See sheet 3 (c) Dimensions-Overall See sheet 3

8. Installation in accordance with Procedure or Drawing No.

Prepared by 50-9073945 Rev 000 as modified by 30-9111839 Rev 000 end 30-9111839 Rev 001 OH Wood 02-9091693E Rev 001 D. H Wood 02-9048971D Rev 007 ODH Wood

9. Hydrostatic test pressure 3107 PSIG at temp.

6.F System design pressure 2485 PSIG at temp.

650T

10. Remarks P*iping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial number In lieu of stamping

.Supplemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 81/2 x 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -Pg.

2 of 3

J Certificate Holder's Serial No.

9091693-002 CERTIFICATION OF DESIGN FOR PIPING SYSTEM AREVA NP Inc.,3315 Old Forest Rd, Lynchburg VA, 24501 Design information on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at Larry DavisCAM37 Design specification certified by P.E. State CA Reg. no.

M33472 James Richard Harrington.

M3381 1 Design report certified by P.E. State A

Reg. no.

Design conditions of pressure piping 2485 psi. Temp.

650

-F.

CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance withthe documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date e

N/A Signed (N or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Report on N/A and state that to the best of my knowledge and belief, the Certificate of Authorization Holder has performed this installation in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date Signed N/A Commissions N/A (Authorized Nuclear Inspector)

INat'l. ed. (ind. endorsements) and state or prov. and no.]

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Certificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement.

Wecertify that the statements made by this report are correct and that the piping system conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of uthorization No.

N-1650 Expires June 12, 2012 ate Name AREVA NP Inc.

Signed IN Certificate Holder)

(authorized relresentative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of.Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSB-CT of Hartford. CT have inspected the piping system described in this Data Report on and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping system in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or,property damage or a loss of any kind arising from or connected with this inspection.

Date 7t-//-,

-Signed-ssions 5656 ABN, VA, 105R

/(Authorized Nuclear Inspector)

(Nationa Bd n endorsements and state or pr-vy and no.]

(09/061

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. 3 of 3 Certificate Holder's Serial Nos.

SIN 9091693-002 Attachment to ASME FORM N-5 for RVLIS Subassembly 2,

1. Installed and Certified by: AREVA NP, 3315 Old Forest Rd, Lynchburg VA, 24501
4. System Identification: RVLIS Subassembly 2, SIN 9091693-002, Drawing 02-9091693E Rev 001. CRN: N/A. National Board no: N/A. Year Built: 2009.

RVLIS SUB-ASSEMBLY 2 - S/N 9091693-002 Qty Manufacturer Description Heat#-

Overall Dimensions 01.32xl1 3pc Energy and Process 1" SCH 160 SEAMLESS PIPE, SA-376 TP HT# 39131 01.32x12 Corporation 304 01.32x12 01.32x12.38 Heat Code 1

Energy and Process 1" 6000# 90' SW ELBOW, SA-182 F304/L D83 Corporation HT# 0528 01.94x1.19x1.19 1"XI"XI" 6000# SW RESTRICTOR HT#

1 General Nuclear Corporation ORIFICE TEE 9049945 245765 3.12x2.0x2.5 Energy and Process 1" Y PATTERN GLOBE VALVE S/N 1

Energatnd ANCHOR DARLING #1878 97BMY Corporation TAG # RCS-2-603 97BMY

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 pg. 1, of 3_

1. Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for-Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

3. Location of installation Diablo Canyon Power Plant Unit #2 P.O. Box 56, Avila Beach, CA. 94354 (USA)

Reactor Vessel Level Indication 9091693-003 02-i (name and address) 209

4. System identification System (RVLIS) Sub Assembly 3 9091693E Rev 001 N/A NIA (system name)

(Ceat. Holder's serial no.)

ldrawing no.)

ICRN)

(National Sd. no.)

(year Instafled)

5. ASME Code, Section Il1, Division 1 2001 2003 class 1 N-411-1 (edition)

(addenda date)

(class)

(Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (a) Comp. or Appurt.

3/8" 3HN Valve Piping and part installati (b) Name of Certificate Holder Swagelok Company 29500 Solon Rd.

Solon, OH 44139 (c) Serial No.

YU7348-001-0004 YU7348-001-0003 Id) CRN No.

N/A (e) National Bd. No.

(f) Year Built N/A 2009 (a) Piping or Part (b) Name of (f) Year Built-Parts

,Subassembly Certificate Holder (c) Serial No.

(d) CRN No.

(e) National Bd. No.

Only N/A N/A N/A N/A N/A N/A Support installation (b) Name of (a) Suoport No.

Certificate Holder (c) Serial No.

N/A N/A N/A Additional material excluding welding material (a) Name of Manufacturer See sheet 3 See she (d) Design Rept./Load Capac. Data Sheet (e) CRN No.

(f) National Bd. No.

(g) Year Built N/A N/A N/A N/A (b) Material Spec. No.

et3 (c) Dimensions-Overall, See sheet 3

8. Installation in accordance with Procedure or Drawing No.

Prepared by 50-9073945 Rae 000 as modified by 30-9111839 Rev 000 and 30-9111839 Rev 001 DH Wood 02-9091693E Rev 001 OH Wood 02-9048971D Rev 007-ODH Wood

9. Hydrostatic test.pressure 3107 PSIG at temp.
6.

System design pressure 2485 PSIG at temp.

650`F

10. Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial number in lieu of stamping

  • Supplemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 81/2 x 11; (2) information in items 1 and 4 on this Data Report is includedon each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

Certificate Holder's Serial No.

9091693-003 CERTIFICATION OF DESIGN FOR PIPING SYSTEM Design information on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design specification certified by Larry Davis RE. State CA Reg. no.

M33472 James Richard Harrington.

.M31 Design report certified by JRE.

State C

Reg. no.

M33811 Design conditions of pressure piping 2485 psi. Temp.

650

-F.

CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date N/A Name N/A Signed N/A (N or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Report on N/A and state that to the best of my knowledge and belief, the Certificate of Authorization Holder has performed this installation in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty,. expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date N/A Signed N/A Commissions N/A (Authorized Nuclear Inspector)

INat'l. ad. lind. endorsements) and state oa prov. and no.)

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Certificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement.

We certify that the statements made by this report are correct and that the piping system conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1 650 Expires June 12, 2012 Date Name AREVA NP Inc.

Signed (N Certificate Holder) sauthorized representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSBCT of Hartford, CT have inspected the piping system described in this Data Report on f//-2'L

_7 and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping system in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected ith this inspection.

Date 7YI Signed a

Commissions 5656ABNVA, 105R (Authorized Nuclear Inspector)

INational ad. incd. endorsements), and state or prov. and no.]

(09/06)

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg._3 of 3 Certificate Holder's Serial Nos.

S/N 9091693-003 Attachment to ASME FORM N-5 for RVLIS Subassembly 3,

1. Installed and Certified by: AREVA NP, 3315 Old Forest Rd, Lynchburq VA, 24501
4. System Identification: RVLIS Subassembly 3, S/N 9091693-003, Drawinq 02-9091693E Rev 001. CRN: N/A. National Board no: N/A. Year Built: 2009.

RVLIS SUB-ASSEMBLY 3 - S/N 9091693-003 Qty Manufacturer Description Heat #

Overall Dimensions 2pc Dubose Energy TUBING.03/8" X.063 WALL SA-213 TP 316/L HT# 359120 03/8x481ong 03/8x51ong 1

Swagelok

  1. 3/8" SWAGELOK TO TUBE SW UNION THD (NUT) 05/8x1.5 SS-600-6-6W, TP 316 SS UHA (BODY) 5 1

wagelok SWAGELOK END PLUG SJY (Nut) wageo

  1. SS-600-P, TP 316 SS RPU (Body) 03/8x.75 1

Swagelok SWAGELOK 3/8 X 3/8 X 3/8 TEE SGL I

SS-6-TSW-3, TP 316 SS 2.4xl.2xO5/8

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 pg. 1 of 3

1. Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

Diablo Canyon Power Plant Unit #2 P.O. Box 56, Avila Beach, CA. 94354 (USA)

3. Location of installation Reactor Vessel Level Indication (name and address)
4. System identification system (RVLIS) Sub Assembly 5 9091693-005 02-9091693E Rev 001 N/A N/A 2009 (system name)

(Cert. Holder's serial no.)

(drawing no.)

(CRN)

(National ad. no.)

(year installed)

5. ASME Code,Section III, Division 1 2001 2003 Class I N411-1 (edition)

(addenda date)

(class)

(Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (b) Name of (a) Comp. or Appurt.

Certificate Holder (c) Serial No.

(d) CRN No.

(e) National Bd. No.

1* 1878 Y Globe Valve Flowserve Corporation 96eMY N/A N/A 1900 South Sanders St.

95BMY Raleigh NC, 27603 Piping and part installation (a) Piping or Part (b) Name of Subassembly Certificate Holder (c) Serial No.

(d) CRN No.

(I) National Bd. No.

N/A N/A N/A N/A N/A (f) Year Built 2009 (f) Year Built-Parts N/A Only Support installation (a) Support No.

N/A (b) Name of Certificate Holder N/A (d) Design Rept./Load Ic)

Serial No.

Capac. Data Sheet (el CRN No.*

(f) National Bd. No.

(g) Year Built N/A N/A N/A N/A N/A (b) Material Spec. No.

(c) Dimensions-Overall See sheet 3 See sheet 3 Additional material excluding welding material (a) Name of Manufacturer See sheet 3

8. Installation in accordance with Procedure or Drawing No.

Prepared by 9.

10.

50-9073945 Rev 000 as modifed by 30-9111839 Rev 000 and 30-9111839 Rev 001 DH Wood 02-9091693E Rev 001 OH Wood 02-9048971DRev.007 D:

OH Wood Hydrostatic test pressure 3107 PSIG at temp.

System design pressure 2485 PSIG at temp.

Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial number in lieu of stamping

  • Supplemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 81/2 X 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

Certificate Holder's Serial No.

9091693-005 CERTIFICATION OF DESIGN FOR PIPING SYSTEM Design information on file atAREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design specification certified by Larry Davis RE. State CA Reg. no. M33472 Design report certified by James Richard Harrington.

RE. State CA Reg. no.

M33811 Design conditions of pressure piping 2485 psi. Temp.

650 CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date N/A Name N/A Signed N/A IN or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a.valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Report on N/A and state that to the best of my knowledge and belief, the Certificate of Authorization Holder has performed this installation in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date Signed N/A Commissions N/A (Authorized Nuclear Inspector)

[Nat'l. Bd. [ncl. endorsements) and state or prov. and no.]

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Certificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement.

We certify that the statements made by this report are correct and that the piping system conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1650 Expires une 9 9012

-1 Date

'71 J -1 Name AREVA NP Inc.

Signed IN Certificate Holder)

(authorized representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSB-CT 4

of Hartford, CT have inspected the piping system described in this Data Report on ____________

and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping system in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date Signed Commissions 5656 ABN. VA. 105R

/

(Authorized NucTea r Inspector)

[National Bd. (incl. endorsements), and state or prov. and no.]

(09/06)

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section, Ill Pg. 3 of 3 Certificate Holder's Serial Nos.

S/N 9091693-005 Attachment to ASME FORM N-5 for RVLIS Subassembly 5,

1. Installed and Certified by: AREVARNP. 3315 Old Forest Rd, Lynchburq VA, 24501
4. System Identification: RVLIS Subassembly 5, S/N 9091693-005,. Drawinq 02-9091693E Rev 001, CRN: N/A. National Board no: N/A. Year Built: 2009.

RVLIS SUB-ASSEMBLY 5 - S/N 9091693-005 Overall Qty Manufacturer Description Heat #

Ovenson Dimensions 01.32xl1 3pc Energy and Process 1" SCH 160 SEAMLESS PIPE, SA-376 TP HT# 39131 01.32x13 Corporation 304 01.32x14

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 pg. 1 of 3

1. Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

3. Location of installation Diablo Canyon Power Plant Unit #2 P.O. Box 56, Avila Beach, CA. 94354 (USA)

O9082837-001 (name and address) 4.. System identification Sub Assembly SOV 1 02-9082837E Rev 002 N/A N/A 2009 (system name)

(Cert. Holder's serial no.)

(drawinA no.)

ICRN)

(National Bd. no.)

(year Installed)

5. ASME Code, Sectionlil, Division 1 2001 2003 Class 1 N-411-1 (edition)

(addenda date)

(class)

(Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (a) Comp. or Appurt.

1" Solenoid Operated Valve Model 081-1-001 Piping and part installati (a) Piping or Part Subassembly N/A (b) Name of Certificate Holder Target Rock 1966E Broadhollow Road E. Farmingdele, NY 11735 on (b) Name of Certificate Holder N/A (c) Serial No.

SIN: 8, S/N: 7 (d) CRN No.

N/A (e) National Bd. No.

N/A If) Year Built N/A (f) Year Built-Parts N/AOnly (c) Serial No.

N/A (d) CRN No.

N/A (e) National Bd. No.

N/A Support installation (a) Suoport No.

N/A (b) Name of Certificate Holder N/A (d) Design Rept./Load (c) Serial No.

Capac. Data Sheet (e) CRN No.

(f) National Bd. No.

(g) Year Built N/A N/A N/A N/A N/A Additional material excluding welding material (a) Name of Manufacturer See sheet 3 (b) Material Spec. No.

(c) Dimensions-Overall See sheet 3 See sheet 3

8. Installation in accordance with Procedure or Drawing No.

Prepared by 50-9073949 Rae 000 as modified by 30-9111841 Rev 0go DH Wood 02-9082837E Rev 002 DH Wood 02-9046308D Rev 007. and 02-9046310D Rev 005 OH Wood 3107 PSIG 68F 2485 PSIG 650T

9. Hydrostatic test pressure at temp.

System design pressure at temp.

10. Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial~number in lieu of stamping Supplemental Information in the form of lists, sketches, or drawings may be used provided: (1) size is 81/2 X 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

Certificate Holder's Serial No.

9082837-001 CERTIFICATION OF DESIGN FOR PIPING SYSTEM Design information on file at AREVA NP Inc., 3315 Old Forest Rd. Lynchburg VA. 24501 Design report on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Larry D~visCAM37 Design specification certified by P.E. State CA Reg. no.

M33472 James Richard Harrington.

M381 Design report certified by J

Ri. State CA Reg. no.

M33811 Design conditions of pressure piping 2485 psi. Temp.

650

-F.

CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in thii report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed irl accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date N/A Name N/A Signed N/A (N or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commidsion issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Repor( on N/A and state that to the best of my knowledge and belief, the Certificate of Authorization Holder has perforred this installation in accordance with the ASME Code, Section 1II, Division 1.

By signing this certificate neither the inspebtor nor his employer makes any warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date Signed N/A Commissions N/A (Authorized Nuclear Inspector)

INat'l. ad. lincl. endorsements) and state or prov. and no.]

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Cdrtificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement.

We certify that the statements made by this report are correct and that the piping system conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1650 Expires June 12, 2012 Date a

'7 Name AREVA NPlInc.

Signed (N Certificate Holder)

(authorized representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSB-CT of Hartford, CT have inspected the piping system described in this Data Report on and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping 6ystem in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

5656 ABN, VA, 105R Date Signed I*

rz enComm`rtissionsatoad_____no____s,_da_______d_.

(Authorizd Nuclear Inspector)

(National ad. (Inct. endorsements), and state or pray, and no.)

(09/06)

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. 3 of 3 Certificate Holder's Serial Nos.

S/N 9082837-0301 Certificate Holder's Serial Nos.

Attachment to ASME FORM N-5 for Subassembly SOV-1,

1. Installed and Certified by: AREVA NP, 3315 Old Forest Rd, Lynchburg VA, 24501
4. System Identification: Subassembly SOV-1, S/N 9082837-001, Drawinq 02-9082837E Rev 002, CRN: N/A, National Board no: N/A, Year Built: 2009.

SUB-ASSEMBLY SOV S/N 9082837-001 Qty Manufacturer Description Heat #

Overall Dimensions 01.32x6.75 3PC Energy and Process 1" SCH 160 SEAMLESS PIPE, SA-376 TP HT# 39131 01.32x10.5 Corporation 304 01.32x0.5 2

Energy and Process 1" R.F. FLANGE #1500 SW SCH 160 BORE, HT# 9387H 015.88x.62 Corporation SA-1 82 F347 9387HI

- 1 1.

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of 3

1. Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name end address of Purchaser)

3. Location of installation Diablo Canyon Power Plant Unit #2 P.O. Box 56, Avila Beach, CA. 94354 (USA)

(name and address)

4. System identification Sub Assembly SOV2 902837-002 029082837E Rev 002 N/A N/A2 (system name)

(Cert. Holder's serial no.)

(drawing no.)

ICRN)

(National Bd. no.)

(year installed)

5. ASME Code,Section III, Division 1 2001 2003 Class 1 N-411-1 (edition)

(addenda date) lclass)

(Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (a) Comp. or Appurt.

1". Solenoid Operated Valve Model 08H-001 Piping and part installati (a) Piping or Part Subassembly N/A (b) Name gf Certificate Holder Target Rock 1956E Broadhollow Road E. Farmingdale, NY 11735 on (b) Name of Certificate Holder N/A S(c) Serial No.

(d) CRN No.

(e) National Bd. No.

(f) Year Built S/N: 5, S/N: 6 N/A N/A N/A (c) Serial No.

(d) CRN No.

N/A N/A (f) Year Built-Parts (e) National Bd. No.

Only N/A N/A Support installation (a) Suoport No.

N/A Ib) Name of Certificate Holder N/A (d) Design Rept./Load (c) Serial No.

Capac. Data Sheet (e) CRN No.

(f) National Bd. No.

(g) Year Built N/A N/A N/A N/A N/A Additional material excluding welding material (a) Name of Manufacturer See sheet 3 (b) Material Spec. No.

See sheet 3 (c) Dimensions-Overall See sheet 3

8. Installation in accordance with Procedure or Drawing No.

Prepared by 50-9073949 Rev 000 as modified by 30-9111841 Rev 000 DH Wood 02-9082837E Rev 002 DH Wood 02-9046308D Rev 007, and 02-9046310D Ran 005 OH Wood

9. Hydrostatic test pressure 3107 PSIG at temp.

68T System design pressure 2485 PSIG at temp.

650TF

10. Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial number in lieu of stamping

  • SuppIemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 8 1/2 X 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

Certificaie Holder's Serial No.

9082837-002 CERTIFICATION OF DESIGN FOR PIPING SYSTEM Design information on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design specification certified by Larry Davis P.E. State CA Reg. no. M33472 James Richard Harrington.

M33811 Design report certified by P.E. State CA Reg. no.

Design conditions of pressure piping 2485 psi. Temp.

650

-F CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A N/A NAN/A Date N/A Name N/A Signed (N or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Reporton N/A and state that to the best of my knowledge and belief, the Certificate of Authorization Holder has performed this installation in accordance with the ASME Code, Section 111, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable inany manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date Signed N/A Commissions N/A (Authorized Nuclear Inspector)

INat'l. Bd. (incl. endorsements) and state or prov. and no.]

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Certificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement We certify that the statements made by this report are correct and that the piping system conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1650 Expires June 12, 2012 Date Name AREVA NP Inc.

Signed (N Certificate Holder) d(authrized representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSB-CT 71. If 0".y of Hartford, CT have inspected the piping system described in this Data Report on and state that to the best of my knowledge and; belief, the Certificate Holder has connected this piping system in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 7,/*6'#,

Signed Commissions 5656 ABN, VA, 105R Authorized Nuclear Inspector)

(National 8d.

,ncl.

endorsements), and state or prov. and no.]

(09/06)

A CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Certificate Holder's Serial Nos.

S/

Attachment to ASME FORM N-5 for Subassembly SOV-2, Pg. 3 of 3

/N 9082837-002

1. Installed and Certified by: AREVA NP, 3315 Old Forest Rd, Lynchburgq VA, 24501
4. System Identification: Subassembly SOV-2, S/N 9082837-002, Drawinq 02-9082837E Rev 002. CRN: N/A. National Board no: N/A. Year Built: 2009.

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 pg. 1 of 3

1. Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

3. Location of installation Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA. 94354 (USA)

(name and address)

4. System identification Sub Assembly SOV 5 9082B37-005 02-9082837E Rev 002 N/A N/A 2009 (system name)

(Cert. Holder's serial no.)

(drawing no.)

(CRN)

(National Bd. no.)

(year Installed)

5. ASME Code,Section III, Division 1 2001 2003 Class 1 N-411-1 (edition)

(addenda date)

(class)

(Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (b) Name of (a) Comp. or Appurt.

Certificate Holder (c) Serial No.

(d) CRN No.

(1) National Bd. No.

1" Solenoid Operated Valve Target Rock S/N: 10, S/N: 11 N/A N/A Model 08H-001 1966E Broadhollow Road E. Farmingdale, NY 11735 Piping and part installation (a) Piping or Part (b) Name of Subassembly Certificate Holder (c) Serial No.

(d) CRN No.

(e) National Bd. No.

N/A N/A N/A N/A N/A Mf) Year Built N/A (f) Year Built-Parts N/A Only Support installation (a) Support No.

N/A (b) Name of Certificate Holder N/A (d) Design Rept./Load (c) Serial No.

Capac. Data Sheet (1) CRN No.

(f) National Bd. No.

(g) Year Built N/A N/A N/A N/A N/A Additional material excluding welding material (a) Name of Manufacturer See sheet 3 (b) Material Spec. No.

See sheet 3 (c) Dimensions--Overall See sheet 3

8. Installation in accordance with Procedure or Drawing No.

Prepared by 50-9073949 Rev 000 as modified by 30-9111841 Rev 000 DH Wood 02-9082837E Rev 002 OH Wood 02-9046308D Rev 007, and 02-9046310D Rev 005 DH Wood 3107 PS(O 67T 2495 PSIG W

9. Hydrostatic test pressure at temp.

6FSystem design pressure at temp.

10. Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with serial-number in lieu of stamping This subassembly is a spare and can be used in Unit #1 or Unit #2.

  • Supplemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 81/2 X 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and (31 each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

9082837-005 Certificate Holder's Serial No.

CERTIFICATION OF DESIGN FOR PIPING SYSTEM AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design information on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at Design specification certified by

.Larry State CA Reg. no. M33472 James Richard Harrington.

M33811 Design report certified by RE. State C

Reg. no.

M33811 Design conditions of pressure piping 2485 psi. Temp.

650

-F.

CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and thatthis installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date N/A Name N/A Signed N/A IN or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province N/AN/

of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Report on N/A and state that to the best of my knowledge andi belief, the Certificate of Authorization Holder has perforrbed this installation in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any mannerfor any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date Signed N/A Commissions i

N/A (Authorized Nuclear Inspector)

ONati.

ad. (Incl. endorsements) and state or prov. and no.)

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBIUIrY Following completion of the above, the Certificate of Authorization Holder accepting overall responsibility for the piping system shall complete the following statement.

We certify that the statements made by this report are correct and that the piping system conformi to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1650 Expires June 12, 2012 Date Name AREVA NP Inc.

Signed IN Certificate Holder)

(authorized representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSB-CT of Hartford, CT have inspected the piping system described in this Data Report on and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping system in accordance with the ASME Code, Section Ill, Division I.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date

,7

/

Signed 6Comm4isiAons 5656 ABN, VA, 105R (Authorized Nuclear inspector)

INational ad. (incl. endorsements), and state or prov. aed no,)

(09/06)

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. 3 of.3, Certificate Holder's Serial Nos.

SIN 9082837-005 Attachment to ASME FORM N-5 for Subassembly SOV-5,

1. Installed and Certified by: AREVA NP, 3315 Old Forest Rd, Lynchburg VA, 24501
4. System Identification:

Subassembly SOV-5. S/N 9082837-005, Dlawinc 02-9082837E Rev 002, CRN: N/A. National Board no: N/A, Year Built: 2009.

SUB-ASSEMBLY SOV SIN 9082837-005 Overall Qty Manufacturer Description Heat DiOerall

________________________________Dimensions 01.32x6.75 3PC Energy and Process 1" SCH 160 SEAMLESS PIPE, SA-376 TP HT# 39131 01.32x10.5 Corporation 304 01.32x4.80 2

Energyand Process 1" R.F. FLANGE #1500 SW SCH 160 BORE, HT# 9387H 05.88x1.62 2._

Corporation SA-182 F347

FORM N-5 CERTIFICATE HOLDER'S DATA REPORT FOR INSTALLATION OR SHOP ASSEMBLY OF NUCLEAR POWER PLANT COMPONENTS, SUPPORTS, AND APPURTENANCES*

As Required by the Provisions of the ASME Code,Section III, Division 1 pg. 1 of 3

1. Installed and certified by AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address of N or NA Certificate Holder)
2. Installed for Pacific Gas & Electric Company (PG&E) 77 Beale Street, San Francisco, CA 94105, (USA)

(name and address of Purchaser)

3. Location of installation Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA. 94354 (USA)

,name and address)

4. System identification Sub Assembly SOV 6 9082937-006 02-9082837E Rev 002 N/A N/A 2009 (system name)

(Cert. Holder's serial no.)

(drawing no.)

(CRN-(National Bd. no.)

(year installed)

5. ASME Code,Section III, Division 1 2001 2003 Class 1 N-411-1 (edition)

(addenda date)

(class)

(Code Case no.)

6. N Certificate Holder having overall responsibility AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 (name and address)
7. Nuclear components, parts, appurtenances, and supports installed: (List each item and attach copies of N Certificate Holders' Data Reports and NPT Certificate Holder's Data Reports.)

Components (a) Comp. or Appurt.

1" Solenoid Operated Valve Model 08H-001 Piping and part installati (a) Piping or Part Subassembly N/A (b) Name of Certificate Holder Target Rock 1966E Broadhollow Road E. Farmingdale, NY 11735 on (b) Name of Certificate Holder N/A (c) Serial No.

(d) CRN No.

(e) National Bd. No.

(f) Year Built S/N:

9, SIN: 12 NIA NIA N/A (c) Serial No.

(d) CRN No.

N/A N/A (e) National Bd. No.

N/A (f) Year Built-Parts N/A Only Support installation (a) Support No.

N/A (b) Name of Certificate Holder, N/A (d) Design ReptJLoad (c) Serial No.

Capac. Data Sheet (e) CRN No.

(f) National Bd. No.

Ig) Year Built N/A N/A N/A N/A,

N/A Additional material excluding welding material (a) Name of Manufacturer See shoet 3 lb) Material Spec. No.

See sheet 3 (c) Dimensions-Overall See sheet 3.

8. Installation in accordance with Procedure or Drawing No.

Prepared by 50-9073949 Rev 000 as modified by 30-9111841 Rev 000 OH Wood 02-9082837E Rev 002 DH Wood 02-9046308D Rev 007, and 02-9046310D Rev 005 DH Wood 3107 PSIO 67TF 2485 PSI 60*

9. Hydrostatic test pressure at temp.

System design pressure at temp.

650)F

10. Remarks Piping subassemblies fabricated in accordance with AREVA Certified Design Specification 08-9044418-004.

Piping subassemblies marked with seriat number in lieu of stamping This subassembly is a spare and can be.used in Unit #1 or Unit #2.

  • Supplemental information in the form of lists, sketches, or drawings may be used provided: (1) size is 81/2 x 11; (2) information in items 1 and 4 on this Data Report is included on each sheet; and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(09/06)

FORM N-5 (Back -

Pg. 2 of 3

Certificaie Holder's Serial No.

9082837-006 CERTIFICATION OF DESIGN FOR PIPING SYSTEM Design information on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design report on file at AREVA NP Inc., 3315 Old Forest Rd, Lynchburg VA, 24501 Design specification certified by Larry Davis PE. State CA Reg. no. M33472 James Richard Harrington.

CAM33811 Design report certified by RE. State Reg. no.

Design conditions of pressure piping 2485 psi. Temp.

650

-F.

CERTIFICATE OF INSTALLATION COMPLIANCE We certify that the statements made in this report are correct and that this installation conforms to the rules for construction of the ASME Code,Section III, Division 1, and was performed in accordance with the documents listed in 8 above.

N or NA Certificate of Authorization No.

N/A Expires N/A Date N/A Name N/A Signed N/A IN or NA Certificate Holder)

(authorized representative)

CERTIFICATE OF INSTALLATION INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province N/A N/A___________________________________

of N/A and employed by N/A of N/A have inspected the installation of the items described in this Data Report on N/A and state that to the best of my knowledge and belief, the Certificate of Authorization Holder has perfor/hed this installation in accordance with the ASME Code, Section Il, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the installation described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

N/A Date Signed N/A Commissions N/A tAuthorized Nuclear Inspector)

INat'l. 8d. (incl. endorsements) and state or prov. and no.)

CERTIFICATE OF COMPLIANCE FOR OVERALL RESPONSIBILITY Following completion of the above, the Certificate of Authorization Holder accepting overall responribility for the piping system shall complete the following statement.

We certify that the statements made by this report are correct and that the piping system conform§ to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1650 Expires June 12, 2012 Name AR EVA NP Inc.

Date Nam Signed______________

IN Certificate Holder)

Sauthorized represeniignve)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Virginia and employed by HSB-CT of Hartford, CT have inspected the piping system described in this Data Report on and state that to the best of my knowledge and belief, the Certificate Holder has connected this piping system in accordance with the ASME Code,Section III, Division 1.

By signing this certificate, neither the inspector nor his employer makes any warranty, expressed or implied, concerning the piping system described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 7..

Signed Commissions 5656 ABN, VA, 105R S

&Authored Nuclear Inspector)

[National Bd. oncl. endorsements), and state or proy. and no.)

(09/06)

CERTIFICATE HOLDERS' DATA REPORT SUPPLEMENTARY SHEET As Required by the Provisions of the ASME Code Section III Pg. 3 of 3 Certificate Holder's Serial Nos.

S/N 9082837-006 Attachment to ASME FORM N-5 for Subassembly SOV-6,

1. Installed and Certified by: AREVA NP, 3315 Old Forest Rd, Lynchburp VA, 24501
4. System Identification:

Subassembly SOV-6. S/N 9082837-006, Drawina 02-9082837E Rev 002. CRN: N/A. National Board no: N/A, Year Built: 2009.

SUB-ASSEMBLY SOV S/N 9082837-006 Overall Qty Manufacturer Description Heat #

Die nson Dimensions Energy and Process 1" SCH 160 SEAMLESS PIPE, SA-376 TP HT# 39131 01.32x6.75 3PC Corporation 304 01.32x10.5 01.32x4.80 2

Energy and Process 1" R.F. FLANGE #1500 SW SCH 160 BORE, HT# 9387H 05.88x1.62 Corporation SA-182 F347 w

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company Date 1/25/10 77 Beale Street, San Francisco, CA 94106 Sheet 2

, of 2

2. Plant Diablo Canyon Power Plant Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Chemical and Volume Control System (08)

Repair Org. P.O. No., Job No., etc.

5. (a) Applicable Construction Code See Work Order 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 Addenda, Code Case N/A
6. Identification of components.

ASME Name of Name of Manufacturer National Work Other Corrected, Code Serial Board Order Identification Removed, or Component Manufacturer N

No Line No Built Installed,=

Stamped No (Yes or No)

CVCS-2-8378A Velan Valve NF N/A 60006361 Line-50-3 1985 Installed (3)

El Yes CVCS-2-8378B Velan Valve NF N/A 60006363 Line-246-3" 1985 Installed (3) 11 Yes CVCS-2-8379A Velan Valve NF N/A 60006365 Line-50-3" 1985 Installed (3)

El Yes CVCS-2-8379B Velan Valve NF N/A 60006366 Line-246-3" 1985 Installed (3) 0]

Yes CVCS-2-8382A Flowserve 61BEY N/A 60007435 Line-1478-2" 1985 Installed (2)** (N) 0 No CVCS-2-8403 Flowserve E-284A-1-1 N/A 60007438 Line-1312-3 1985 Installed (4)** (N) 0 No CVCS-2-8403 Flowserve E-284A-1-1 N/A 60007438 Line-1312-3 1985 Corrected (5)**

0 No CVCS-2-8364B Flowserve EBO18-3-7 /

N/A 60007600 Line-2534-3/4" 1985 Installed (2) (N)

El No 3535 CVCS-2-294 Flowserve 92BPA N/A 60007600 Line-2534-3/4" 1985 Installed (2) (N)

El No CVCS-2-8148 Copes-Vulcan NF N/A 60020193 Line-4532-2" 1985 Installed (3)

El No 78-419SL Anchor-Darling 79 N/A 60015123 Line-57-1.5" Unk Installed (6)

El Yes78-137SL Anchor-Darling 17 N/A 60020159 Lin'e-402 1985 Installed (6)

El Yes

7. Remarks (continued) (2) Replaced valve and assoc piping. (3) Replace bolting. (4) Replaced valve.

(5) Repair of Reject RI indication in new weld. (6) Replaced snubber.

(N) New item. Code Data Report attached.

DATA PACKAGE NO.

061026 FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES

1 of 2

1. Manufactured and certified by VELAN INC. 2125 WARD AVE,MONTREAL.QUEBEC CANADA H4M1T6 (name and address of N Certificate Holder)
2. Manufactured forPacific Gas&Electric Co.Diablo Canyon Power Plant,PO.box.56 Avila Beach,CA (name and address of purchaser)
3. Location of installation Diablo Canyon Power Plant 9 miles N.W of Avila Beach CA 93424 USA (name and address)
4.

Model No.,

Series No., or Type:

PISTON Drawing Pl-76800-N34 Rev A

CRN N/A

5.

ASME Code,Section III, Division 1:

1989 NONE 21 N/A (edition)

(addenda date)

(class)

(Code Case no.)

6.

Pump or valve VALVE Nominal inlet size 2

Outlet size 2

(in.)

7. Material: Body SA-182, F316 Bonnet SA-182, F316 Disk t-NS-N99644 (in.)

Bolting N/A (a)

Cert.

Holder s Serial No.

(b)

Nat 1 Board No.

Body Serial No.

(d)

Bonnet Serial

-No.,

(e)

Disk Serial NO.

061026-1 061026-2 061026-3

.061026-4 061026-5 061026-6

. 061026-7 N/A N/A N/A N/A N/A N/A N/A H/C.

MMRMUl H/C:

MMRMU1 H/C:

MHRMUl H/C:

MMRMU1 H/C:

MMRMtJ1 H/C:

MMRMU1 14/C:

HdMRMtJ1 H/C:

1DOA H/C:

1DOA H/C:

IDOA H/C:

lDOA H/C:

1DOA H/C:

lDOA H/C:

1DOA H/C:

2CDV H/C:

2CDV H/C:

2CDV H/C:

2CDV H/C:

2CDV H/C:

2CDV H/C:

2CDV Supplemental information in form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11, (2) information in items I through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form, (12/88)

This form (E00037) may be obtained from the Order Dept., ASME, 22 LAW DRIVE, Box 2300, Fairfield, NJ 07007-2300.

FORM NPV-1 (Back-Pg.

2 of 2

)

.o 9'

Certificate Holder's Serial No.

061026

8.

Design conditions 6430 psi (pressure)

9. Cold working pressure

.6430 100 (temperature) psi at 100OF OF or valve pressure class 2680 (1)

10. Hydrostatic test 9650 psi.

Disk differential test pressure 7075 psi

11. Remarks:

MATERIALS MEET ASME SECTION II EDITION: 1989 ADDENDA:

NONE CERTIFICATE OF DESIGN Design Specification certified by M. LAVIGNE P.E. State QUE Reg. no.

40052 Design report certified by S.

ISBITSKY P.E. State QUE Reg. no.

22115 CERTIFICATE OF COMPLIANCE We certify that the s tatements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-2797-1 Expires APR 20,2007 Date 2

Name VELAN INC.

Signed jP (N Certificate Holder)

(authorized representative)

CERTIFICATE OF INSPECTION I,

the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of QUEBEC and employed by REGIE DU BATIMENT of QUEBEC have inspected the pump, or valve, described in this Data Report on/VVflr *Q 2<v6, and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate,, neither -the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data-Report.

Furthermore, neither the inspector nor his, -

loyer shall be liable in any manner for any personal injury or property da age or a lo s f a y find arising from or connected with this inspection.

Date 3o-..7ý/6 signed

  • L..A Commissions QUEBEC

.C.

V no.)

(Nat'l. l3d. (incf-enY6,,'?&

il (1)

For manually operated valves only.

FORM NPV-1 N CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Div. 1 Pg. I of 2

1.

Manufactured by Flowserve Corporation, 1900 S. Saunders St.,

Raleigh, NC 27603 (Name end Address of N Cerlificate Holder).

2.

Manufactured for Pacific Gas and Electric PO Box 7760 San Francisco, CA 94120-7760 (Name and Address of Purchaser or Owner)

3.

Location of Installation

4.

Pump or Valve (a) Model No.

Series No.

or Type (Name and Address)

Valve, (b) N Certificate Holder's Serial No.

Nominal Inlet Size (c) Canadian Registration No:

2" (inch)

Outlet Size 2"

(inch) d) Drawing No.

(e) Class (f) Nat'l.

Bd. No.:

(g) Year Built (1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10) 1 O'¶*t V1 X7 X.T/ A

  • 31.10N*'t'JN'J:,*

l'}l*l.Y l*

I

"*T / A

-nat 10 10t.

0 O D I.L 1 V Y.O JU,J'7

.Jt V.J 2

. 1o'V lU

'1878#

59BEY N/A W8923035 REV. E 1

N/A 2006 1878#

60BEY N/A W8923035 REV. E 1

N/A 2006 1878#

61BEY N/A W8923035 REV. E 1

N/A 2006 1878#

62BEY N/A W8923035 REV. E 1

N/A 2006 1878#

63BEY N/A W8923035 REV. E 1

N/A 2006

5.

2"-1.878 Globe Valve (Brief description of service for which equipment was designed) 36699 Item 001

6.

Design Conditions 2735 psi

680, OF or Valve Pressure Class 1878 (1)

(Pressure)

(Temperature)

7.

Cold Working Pressure 4507 psi at 100 OF.

8.

Pressure Retaining Pieces Mark No.

Material Spec. No.

Manufacturer Remarks N2377 SA351 CF8M Flowserve Body (b) Forgings 21560 A747-Cb7-Cul-Hl100 Flowserve Disc 4..

4 4.

+/- __________________

2 __________________

2 __________________

(1) For manually operated valves only.

  • Supplemental sheets in form of lists, sketches or drawings may be used provided (I) size is 8-112" x 11",

(2) information in items 1, 2 and 5 on this Data Report is included on each sheet, and (3) each sheet is numbered and number of sheets is recorded'at top of this form.

1'2-

FORM NPV-1 (Back)

Pg. 2 of 2, Valve SIN 58BEY through 63BEY Mark No.

Material Spec. No.

Manufacturer Remarks (c) Bolting (d) Other Parts

9.

Hydrostatic test 6775 psi.

Disk Differential test pressure.

4960 Psi.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump, or valve, to the rules of construction conforms 1986 of the ASME Code, for Nuclear Power Plant Components.

Section III, Div.

1.,,

Edition Addenda No

'Code Case No.

N/A Date

  • -// d*?

Signed Flowserve Corp.

by (N Certificate Holder)

Our ASME Certificate of Authorization No.

N-1562 to use the N

symbol expires 11-26-06 (N)

(Date)

CERTIFICATION OF DESIGN Design information on file at Flowserve Corporation Raleigb, NC Stress analysis report (Class 1 only) on File at Flowserve Corporation Raleigh, NC Design specifications certified by (1)

Mark Cowell PE State PA Reg. No.

032082.

Stress analysis certified by (1)

R.S. Farrell PE State NC Reg. No.

028656 (1) Signature not required. List name only.

CERTIFICATE OF SHOP INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of North Carolina and employed by HSB CT of Hartford Connecticut have inspected the pump, or valve, described in this Data Report on 1

40, and state that, to the best of my knowledge and belief, the N Certificate Holder has constructed this pump, or valve, in accordance with ASME Code, Section IlLI By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the equipment described in this s Data Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury dr property damage or a loss of any kind arising from or connected with this Inspection.

Date Signed

/71*ý7 4;12/

Commissions W

( Inspector)

(Naft Bd*, State, Prov. and No,)

FORM NPV-1 CERmiFCAT1 HOLWRS DATA F

FOR NUCLEM R PUPS OR VALVES*

As Required by the Provisions of he A SM Code. Seedion UL DW

" I.

Po. -

of-BW/IP International, Inc. Valve Division 701 First Street, Williamsport, PA 17701 4 MwAtUnmW and certifted by "nan" urs Mamie of N CeeWiAM N~

2 MtawSUMW

,t, Pacific Gas & Electric Co.,

P.O.

Box 7760, San Francisco, CA 94120-7760

3.

LI Diablo Canyon Power Plane, 9 Miles NW of Avila Beach, Avila Beach, CA Y-Globe W98-25047 C

4. Model M.. knm M.. orTyp O-Gloe u

,. A" C.d SWUMno1. OieItA 1:

1989 No 2

N/A

6.

or vow Valve No""

3" ouea 3"

7.

M I

SA351-CF8M bImw SA479-316 SA479-S34700100 E2SA4A-1 -2 mi No.

N/A N/A leiy Mso Y84 3 Me.

z2 leig No.

I anVWCmR~m s mksdon*mb Urne. 121 eg., awe megMe &,d gm moer of -

ies,,

mae -at a* too o4 onI fwY..

(12AM

?Ne f m (30 S71 m wa be t

owne Om Ordr D =L. A RM. 22 Law Duly. 1 2300. Fobfl. I MJ 07007.2300.

-~4....

4

..~

~

A..~r!RW~

P.

  1. -YGB Globe Valve w/B320-10 B.G. Actuator 3" x 2" x 3"-1816
8. Ramarui t

2735 579 1816 Mo Coidwo kyahjp 4358 w a Ioo°,

1t.

"do*

s 6550..

L OWk~mm"ftM PRvMW 4794

.. i W

Kersi J. Dalal PACA Siim C-16690 OuiwfmaoeruI by e

The'ron'C. BArtlitt II P.LS S PA tgno.na 39T6777

-1 11MCAUý OF' SHOP-COWAMUNC VOWe Y*

awty GmUN uaimw "WNW hi"*#P WOm=RIM

-A osim m dft piump or valveo amifmuto 1

h now e ~tarcowStUnth Wf 9AISW Cede. Isedan W. Okelen 1.

N CAN*w t eeA.

hwwiad N&

A1712 4/1~5/01 I

I_ F-;?/- 1R w/lr Internationa+/-, inc.

ValveDivision,.

-U-

,~s cip N~..

1' ii 1PCTa OF 8"Om Room.on 1.*aunderulgne~dh

- eewsmJ

-%@Lod by dw~tie Nu&,. ed of aile owd Pemumw

,Veowe Inepectart and go so" mmmmme.

Wilnv'vzip.

o.,iouu rctia Unio~n Ins, Co.

~~ U~e up.,

Nrle 'inuba thii Uii m

Npn an OWsot h

t O mt of widg mand belef. doe Carif,= oesMdde hee auawddib ~p. a ~,a asemudom wid, ft ASM Cede.

eaI M. fiMeln 1.

d g*i aii mopdae nilme as WNW@~

e ter ai emlyer" mowe

  • ay Warrty. gispreege or FNpld. concameiq the onnewoaf deeribad in OWl Oem ReuJmmee nelie he aepeo ncr

~

Meeplyr be W"l hianyw manner far amy pale k*Ay ar prepauso wwew"ee~nyi

  • wlin fomr parIneteld ofth th Ineea.

77,vvPe~nnsylvania 2322 A )1A*S5 r4 INWI. md ow. WNWWerMM awm.

ew

"*.I (11 FW nsnUa7 ow V"www only.

r

3. Loostin of3S D be
m.

pdir: P

.1la

4. Model Ole. Seda e N., or Tmp Ai NIAn

.jZ2...Rv

11. AIMS Ceds, Section E. Okimn 1:

q...i........

.liL1M92.1.....

Wk....JL.

Qaý;ki WNW) icaft mc Am.)

6.

"wn or van... LXB....."....

manbn

7.

11 A/

00h~Ir

~."3 Crr 34-t.

/VV 7

./A ~

____In Ism;

&*O@WApgMminrbeoW in~~g

  1. amlu of Urn. mkdrnas ofwig IMW be urnd

'Aeim dii) m) jee x

ONO is

~~ai Itms4U~

andf Daftm~u Is w

vduatdm an aadrn dom. 131 sad' dies mnrnbmmi & Im Uns mw of shastais roesrfds atn go t of *ft fom.

(1RIM.

This form 30007) MaW be M eitmId from ft Oere DOOLt.

ASIAL 22 Law OWw. lift 3300, PiWf~IK NJ 0100.230.

)UOI WTA.

.Dl e'il l PkýA 11

~; ~

'No r"o fi 7A~~~ieVle~1!

i

~~~

r Sl A,

In

ý"~

z 1"

"4 q

11.~~~o iwmi a*"

g.

~.

iur e

~2.

K K-.

K.K, PA g-Me.

C IA 4746 Deip' ~

~

~

~

~

~

P N.Iee,3 y5 r2 eg o ____il I

oth.~i~gdmUOg~Eioni NZ

-tA I

A I

I l

-Wi-lliLAO-MW~fit WO

l.

-0 "inno L s Xi fto a

hb AM

=

od0 eaden w. "hlsion 1.

rn

-ftnsyvani a--2392-

~

.,,t..~ ~

2.2.

'2.2.,. A'...

- 44A 4.t

.*44A.2....Ii23422A.2.IAAfl.~i4;AA'32.4.2444.a441tt 2.4-42.44-43

/

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 P

2

g. 1 of
1. Manufactured and certified by Flowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N Certificate Holder)
2. Manufactured for Pacific Gas & Electric Company, P.O. Box 7760, San Francisco, CA 94120-7760 (name and address of Purchaser)
3. Location of installation Diablo Canyon Power Plant, 800 Price Canyon Rd., Pismo Beach, CA 93449 (name and address)
4. Model No., Series No., or Type 1878# GLOBE VALVE Drawing W9424267 Rev.

G CRN N/A 5.' ASME Code,Section III, Division 1:

1986 NO 1

NjA, (edition)

(addenda date)

(class)

(Code Case no.)

6..Pump or valve ValVe Nominal inlet size 3/4 Outlet size 3/4 (in.).

(in.)

7. Material:

(a) valve Body SA351-CFBM Bonnet N/A (b) pump Casing Cover A747-CB7-Cu 1-H 1100 Disk Bolting N/A Bolting (a)

Cert.

Holder's Serial No.

68BPA 69BPA 70BPA 71BPA 72BPA 73BPA 74BPA 75BPA 76BPA 77BPA 78BPA 79BPA 80BPA 81BPA 82BPA 83BPA 84BPA 85BPA 86BPA 87BPA 88BPA 89BPA 90BPA 91BPA 92BPA (b)

Nat')

Board No.

N/A N/A N/A N/A N/A N/A N/A.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (c)

Body/Casing Serial No.

P3448-1 P3448-2 P3448-3 P3448-4 P3448-S P3448-6 P3448-7 P3448-8 P3448-9 P3448-10 P3368-1 P3368-2 P3368-4 P3368-S P3368-6 P3368-7 P3368-8 P3368-9 P3368-10 P3368-11 P3368-12 P3368-13 P3368-14 P3368-15 P3368-16 (d)

Bonnet/Cover Serial No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (e)

Disk Serial No.

6992-11 6992-12 6992-13 6992-14 6992-15 6992-16 6992-17 6992-18 6992-19 6992-20 6992-41 6992-42 6992-43 6992-44 6992AS 6992-31 6992-32 6992-33 6992-34 6992-35 6992-36 6992-37 6992-38 6992-39 6992-40

  • Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 81/2 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

/

FORM NPV-1 (Back -

Pg. 2 of 2 68BPA THRU 92BPA Certificate Holder's Serial No.

2735 680

8. Design conditions psi

'F or valve pressure class 1878 (pressure)

(temperature)-

9. Cold working pressure 4S07 psi at 100°F 6775 4960
10. Hydrostatic test psi.

Disk differential test pressure psi

11. Remarks: S.O. 53099-05 CERTIFICATION OF DESIGN Design Specification certified by Floyd A. Bensinger RE. State PA Reg. no. PE-31002-E Design Report certified by Ron S. Farrell P.E. State NC Reg. no. 028656 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section I1l, Division 1.

N Certificate of Authorization No.

N-1562 Expires 11-26-09 Date Name Flowserve Corporation Signed (N Certificate Holder)

Sae

-r eresentadve CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB CT of Hartford, CT have inspected the pump, or valve, described in,this Data Report on I* 2*S/

, and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in acco dance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 2dQ Signed Commissions rihorlzed Nuclear

.nspec.

[Nal. 8d. icl. endorsements) end state or prov. and no.1

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106 Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424 Date 1/25/10 Sheet I

of 3

Unit 2

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Safety Injection System (09)

5. (a) Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -
6. Identification of components.

Addenda, Code Cases N/A

2001, 03 (c) Addenda, Code Case N/A ASME Manufacturer National Other Corrected, Code Name of Name of Work Order Year Serial Board Wor Identification Removed, or Stamped No.

No.

Line No Installed (Yes or No)

SI-2-8952A Velan Valve 891210-10 N/A 60006718 Line-SI-2" for 1985 Installed (1)*

0 No LT-950 (N)

SI-2-8949A Velan Valve NF N/A 60007926 Line-235-6" 1985 Installed (2)

No 2216-320 NPS N/A N/A 60020910 Line-7178-3/4" 1985 Installed (3) -

No 326-403R PG&E N/A N/A 60021145 Line-3866-3/4" 2009 Installed (4)

D_

No Line-3855 PG&E N/A N/A 68003580 Line-3855-2" 1985 Installed (5)**

0 No

7. Description of Work (l)Replace valve and assoc piping. (2) Replace Bonnet bolting. (3) Replace pipe clamp.

(4) Replace missing u-bolt nuts. (5) Replace piping with new vent installation.

8. Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure Z Exempt El Other F1 Pressure See rmks PSIG Test Temp.

<100

'F

9. Remarks

(*) Accum press = 600 psig.

(**) SI pump discharge press = 1700 psig.

(N) New item. Code Data Report attached.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are cgx*e d that this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp N)A-Ce tat o Authorization No.

N/A Expiration Date N/A Signed (79,

/

Engineering Manager

/

- // 0 (Owner or Owner'sDesignee)

Patrick

-1igent (Title)

(Date)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising I

f 1ýejeg..with this inspection.

Inspector cQ --- I -1/0 Commissions CA 1828 - NB 9990 A.N.I.C

. KewfD. Kim (Title)

(Date)

(State or Province, National Board)

Note: Supk ental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet'is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

-J

1. Owner Pacific Gas and Electric Company Date 1/25/10 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Sheet 2

of 3

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Safety Injection System (09)

5. (a) Applicable Construction Code See Work Order 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Co

2001, 03 de Cases N/A Addenda, Code Case N/A
6. Identification of components.

S ASME Manufacturer National Work Other Corrected, SCe Serial Board Order Identification Removed,'or Code Component Manufacturer No No.

No.

Line No Built InstalledStamped (Yes or No)

Line-3856 PG&E N/A N/A 68003581 Line-3856-2" 1985 Installed (5)**

Z No Line-3857 PG&E N/A N/A 68003582 Line-3857-2" 1985 Installed (5)**

Z No Line-3858 PG&E N/A N/A 68003583 Line-3858-2" 1985 Installed (5)**

0 No SI-2-313C Anchor Darling 94BPA N/A 68004684 Line-3866-3/4" 2009 Installed (6) (N)

El

'No SI-2-313A Anchor Darling 77BPA N/A 68004686 Line-689-3/4" 2009 Installed (6) (N)

E]

No SI-2-313B Anchor Darling 72BPA N/A 68004686 Line-691-3/4" 2009 Installed (6) (N)

El No SI-2-313D Anchor Darling 92BNT N/A 68004687 Line-3867-3/4" 2009 Installed (6) (N)

El No 326-423R PG&E N/A N/A 68004690 Line-689 & 691 2009 Installed (7)

El io 326-412R PG&E N/A N/A 68004963 Line-689 & 691 2009 Installed (7)

El No 326-413R PG&E N/A N/A 68004964 Line-689 & 691 2009 Installed (7)

El No 326-414R PG&E N/A N/A 68004965 Line-689 & 691 2009 Installed (7)

0.

No 326-415R PG&E' N/A N/A 68004966 Line-689 & 691 2009 Installed (7)

El No 326-416R PG&E N/A N/A 68004967 Line-689 & 691 2009 Installed (7)

El No 326-433R PG&E N/A N/A 68004972 Line-691-3/4" 2009 Installed (7)

El No 326-392R PG&E N/A N/A 68004973 Line-3867-3/4 2009 Installed (7)

El No 326-393R PG&E N/A N/A 68004974 Line-3867-3/4 2009 Installed (7)

Ell No 326-403R PG&E N/A N/A 68004989 Line-3866-3/4 2009 Installed (7)

El No 326-404R PG&E N/A N/A 68004990 Line-3866-3/4 2009 Installed (7)

El No 326-405R PG&E N/A N/A 68004991 Line-3866-3/4 2009 Installed (7)

El No 326-406R PG&E N/A N/A 68004992 Line-3866-3/4 2009 Installed (7)

El No 326-408R PG&E N/A N/A 68004993 Line-3866-3/4 2009 Installed (7)

El No 2217-12R PG&E N/A N/A 68005061 Line-1993-1.5" 1985 Installed (8)

El No 414-841SL Anchor Darling 907 N/A 68005160 Line-1977-4" 2009 Installed (9)

[1 No Line-689 PG&E N/A N/A 68005180 Line-689-3/4" 2009 Installed (10)

El Noý,

Line-691 PG&E N/A N/A 68005180 Line-691-3/4" 2009 Installed (10)

El No

,SI-2-301A Anchor Darling 90BNT N/A 68005204 Line-1999-3/4" 2009 Installed (6) (N)'

E No SI-2-301C Flowserve Corp.

73BPA N/A 68005240 Line-2001-3/4" 2009 Installed (6) (N)

El No SI-2-301D Anchor Darling 04BNUJ N/A 68005241 Line-2002-3/4" 2009 Installed (6) (N)

El No SI-2-301B Anchor Darling 98BNT N/A 68005280 Line-2000-3/4" 2009 Installed (6) (N),

El No

7. Remarks (continued)

(5) Replace piping with new vent installation. (6) Re-route Class-I line / install new piping and valve.

(7) Install new Class-1 pipe support. (8) Class-I support attachment by welding. (9) Install new Class-2 support.

(10) Modify Class-1 piping. (N) New item. Code Dkta Report attached.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI


r

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Date 1/25/10 Sheet 3

of 3

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Safety Injection System (09)

5. (a) Applicable Construction Code See Work Order.

19 Edition Addenda, Code Cases N/A (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

2001, 03 Addenda, Code Case N/A
6. Identification of components.

Manufacturer National Work Other Corrected, ASME Name of Name of 11Year Corced Code Comnen Mfam nfa Serial Board Order Identification Removed, or S

Component Manufacturer N.N.

o.LnNo Built Isled Stamped j __________J No.

J No.

No.

Line No Blt Installed (YsoN)

(Yes or No)

Line-2573 PG&E N/A N/A 68005282 Line-2573-1" 2009 Installed (10)

El No SI-2-309 Flowserve Corp.

98BPA N/A 68005282 Line-7178-3/4" 2009 Installed (11) (N) 0l No Line-S6-3/4" off SI-2-311 Flowserve Corp.

70BPA N/A 68005282 of 71,78-3/4" 2009 Installed (11) (N)

El No Line-3866 PG&E N/A N/A 68005283 Line-3866-3/4 2009 Installed (10) 0l No 564-182 PG&E N/A N/A 68005426 Line-691-3/4" 1985 Installed (12)

Dl No 7-149R PG&E N/A N/A 68005502 Line-1977-4" 1985 Installed (12)

El No 2216-234 PG&E N/A N/A 68005540 Line-2002-3/4" 1985 Installed (12)

El No 2211-16 PG&E N/A N/A 68005543 Line-1999-3/4" 1985 Installed (12)

Dl No 2211-4 PG&E N/A N/A 68005544 Line-2000-3/4" 1985 Installed (12)

El No 2216-28 PG&E N/A N/A 68005545 Line-7178-3/4" 1985 Installed (13)

El No 2216-94 PG&E N/A

'N/A 68005546 Line-7178-3/4" 1985 Installed (12)

El No 2216-308 PG&E N/A N/A 68005548 Line-1976-2" 1985 Installed (12)

El No 2216-144 PG&E N/A N/A 68005549 Line-1990-2" 1985 Installed (12) 0 No 2215-23 PG&E N/A N/A 68005750 Line-2001-3/4" 1985 Installed (12)

El No 48-44V PG&E N/A N/A 68006241 Line-223-12" 1985 Installed (14)

[E No 2009 564-184 PG&E N/A N/A 68006283 Line-691-3/4" 19 Installed (7)(15)

El No 2211-18 PG&E N/A N/A 68007241 Line-2000-3/4" 1985 Installed (16)

El No El

7. Remarks (continued)

(7) Install new Class-1 pipe support. (10) Modify Class-1 piping. (11) Install new piping and valve.

(12) Modify support. (13) Modify Class-3 support and upgrade to Class-1 support. (14) Class-2 support attachment by welding.

(15) Weld pipe lugs to line. (16) Replaced U-bolt. (N) New item. Code Data Report attached.

1. Manuachired b 2.

3.

Momdcta~

f&,

ý Location of frstaatiaon Nominal

4. Pump-of Inlet size Outlet Slie (a) Model No., (b) N Certificate Holder's (c) Canadian Series No.

Serial Registration or Type No.

No.

(d) Drawing No.

(f) Nat'l.

(a) Class Od. No.

(g) Year Built 5

6 7

E (2) 9A,: a (3)-

(4) 15)

(6) 17)

(6l 19) 1001 (Brief description of service fto which equipment was designed)

Design Conditions AAL9 psi,

O

'F or Valve Pressure Class J q[:.O (1) 00isbualtl (Ternperaturel

7. Cold Working Pressure psi at 100rF.

I. Pressure Retaining Pieces Mark No.

Material Spec. No.

Manufacturer Remarks fa) Castings (b) Forgings fe i

\\%*I.-

T

'S..-

(1) For manually operated vakes only.

  • SUppmental sheets in form of ists. sketCh" of drawings may be used provided I11 size is 8.11 x 11". (2) information in iems 1. 2 and S on this Data Report is incfu~nd on each sheet, and (3) each h is nujmbefed end number of ohemts is recorded at top of this form (10177)

This form (EW 71 maW be obtaied from the Oir Dept.. ASIE. 345 E. 47th St.. New York. N.Y. 10017

~~P7 7P a-r~

7

'~

~,

4

&r~S~!4 1d) Other Parts

9. Hydrostatic test psi.

Disk Differential test pressure-psi.

We certify that the tatements made in this report are correct and that IhN,mp.

or valve, conforms to..the ruln of construction of )he AME Code for Nuclear Power Plant Components. S n III, Div. I.. Edition Addenda Code Case No.

DOteslo Signed V

\\%

N MIT IN ceilficate Holder)

Our ASME Certificate of Authorization No.1

WSA to use the V4

-symbol expires

~eR11RC11O OF DESMG Design information on file at s.. %s to CL Stress analysis report (Class i only) on file at Design specifications certified by (1)

PE State

.C Reg. No Stress analysis certified by (1)

S.

t l

PE State 9 Reg. No.

(1) Signature not required. List name only.

CERMPCATE OF SHOP NINSECTION I. the undersigned, holding a valid co~mission issued by the National Board of "oI ~grnd Pressure Vsas

'cl ec.,

and the State Province of E

and emr.nyed by Of have inspected the pump, or valve, described in this Data Report on

,41A6 19

.and state that to the best of my knowledge and belief, tVi N Certificate Holder has con-structed this pump. or valvm in accordwc with the ASME Code. Section Ill.

By signing this cerflsee. neither the Inspector nor his employer makes any warranty, esupresed or implied.,*.,.ig the equipment descrilbed in this Dat Report. Furthermore, neither the Inspector nor his emloyn~

sihall be liable in any manner Mi property damage or a lsos of any kind-Sriing from or connected with this inspection.

Commissions AV P"K Wd (NM4 a., stema Pay. W4l No.)

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR. NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 2

Pg. 1, of __

1. Manufactured and certified by Flowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N Certificate Holder)
2. Manufactured for Pacific Gas & Electric Company, P.O. Box 7760, San Francisco, CA 94120-7760 (name and address of Purchaser)
3. Location of installation Diablo Canyon Power Plant, 800 Price Canyon Rd., Pismo Beach, CA 93449 (name and address)
4. Model No., Series No., or Type 1878# GLOBE VALVE Drawing W9424267 Rev.

G CRN N/A

5. ASME Code,Section III, Division 1 1986 NO 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6. Pump or valve Valve Nominal inlet size 3/4 Outlet size 3/4 (in.)

(in.)

7. Material:

(a) valve (b) pump Body SA351-CF8M Bonnet N/A Casing Cover A747-CB7-Cu1-H 1100 e

Disk Bolting N/A Bolting (a)

Cent.

Holder's Serial No.

93BPA 94BPA 95BPA 96BPA 97BPA 98BPA 99BPA 01BPB 02BPB 03BPB (b)

Nat'l Board No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (c)

Body/Casing Serial No.

P3668-17 P3668-18 P3668-19 P3668-20 P3668-21 P3668-22 P3668-23 P3668-24 P3668-25 P3668-26 (d)

Bonnet/Cover Serial No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (e)

Disk Serial No.

6992-21 6992-22 6992-23 6992-24 6992-25 6992-26 6992-27 6992-28 6992-29 6992-30

  • Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 812 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

LF

FORM NPV-1 (Back -

Pg. 2 of 93BPATHRU 99BPA 01BPB ThRU 03BPB Certificate Holder's Serial No.

8. Design conditions 2735 psi 680

'F or valve pressure class 1878 (pressure)

(temperature)

9. Cold working pressure 4507 psi at 100'F 6775 4960
10. Hydrostatic test psi.

Disk differential test pressure psi

11. Remarks: S.C. 53099-05 0,

CERTIFICATION OF DESIGN Design Specification certified by Floyd A. Bensinger P.E. State PA Reg. no. PE-31002-E.

Design Report certified by Ron S. Farrell P.E. State NC Reg. no. 028656 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and'that this pump or valve conforms to the rules for construction of the ASME Code, Section Ill, Division 1..

N Certificate of Authorization No.

N-1562 Expires 11-26-09 Date Name Flowserve Corporation Signed (N certificate Hoider a o) representative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC andemployed by HSB CT of Hartford, CT.

have inspected the pump, or valve, described in this Data Report on

-7 2? /and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code, Section 111, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 17 Signed Commissions tS_.

_Z_.

  • /'

N torized Nuclear Ir-eP erl

[Nati'iBd. (incl. endorsements) and state or prov. and no.]

t'

\\

./,

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code, Section. Iii, Division 1 Pg. 1 of

1. Manufactured and certified by FlowserveCorporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N Certificate Holder)
2. Manufactured for Pacific Gas & Electric Company, P.O. Box 7760, San Francisco, CA 94120-7760 (name and address of Purchaser)
3. Location of installation Diablo Canyon Power Plant, 800 Price Canyon Rd., Pismo Beach, CA 93449 (name and address)
4. Model No., Series No., or Type 1878# GLOBE VALVE Drawing W9424267 Rev.

G CRN N/A

5. ASME Code,Section III, Division 1:

1986 NO 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6. -Pump or valve Valve Nominal inlet size 3/4 Dutlet size 3/4 (in.)

(in.)

7. Material:

A747-CB7-Cul1-H1t100 (a) valve Body SA351-CF8M Bonnet N/A Disk Bolting N/A (b) pump Casing Cover Bolting (a)

Cert.

Holder's Serial No.

.68BPA 69BPA 70BPA 71BPA 72BPA 73BPA 74BPA 75BPA 76BPA 77BPA 78BPA 79BPA 80BPA 81BPA 82BPA 83BPA 84BPA 85BPA 86BPA 87BPA 88BPA 89BPA 90BPA 91BPA 92BPA (b)

Nat'l Board No.

N/A N/A N/A N/A N/A-N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (C)

Body/Casing Serial No.

P3448-1 P3448-2 P3448-3 P3448-4 P3448-5 P3448-6 P3448-7 P3448-8 P3448-9 P3448-10 P3368-1 P3368-2 P3368-4 P3368-5 P3368-6 P3368-7 P3368-8 P3368-9 P3368-10 P3368-11 P3368-12 P3368-13 P3368-14 P3368-15 P3368-16 (d)

Bonnet/Cover Serial No.

N/A N/A N/A NtA N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (e)

Disk Serial No.

6992-11 6992-12 6992-13 6992-14 6992-15 6992-16 6992-17 6992-18 6992-19 6992-20 6992-41 6992-42 6992-43 6992-44 6992-45 6992-31 6992-32 6992-33 6992-34 -.

6992-35 6992-36 6992-37 6992-38 6992-39 6992-40

  • Supplemental information in the form of lists, sketches, or drawings may be used provided (I) size is 0 1/2 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and 'the number of sheets is recorded at the top of this form.

2 FORM NPV-1 (Back -

Pg. 2 of ___

68BPA THRU 92BPA Certificate Holder's Serial No.

2735 680

8. Design conditions 2735 psi 6

'F or valve pressure class 1878 (pressure)

(temperature) 4507

9. Cold working pressure psi at 100°F 6775 4960
10. Hydrostatic test psi.

Disk differential test pressure psi

11. Remarks: S.O. 53099-05 CERTIFICATION OF DESIGN Fly.BnigrPA PE-31002-E Design Specification certified b Floyd A. Bensin er P.E. State Reg. no. PE-31002-_

Design Report certified by Ron S. Farrell P.E. State NC Reg. no. 028656 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code, Section II1, Division 1.

N Certificate of Authorization No.

N-1562 Expires 11-26-09 Date Name Flowserve Corporation Signed 3

J (N Certificate Holder)

)a eresentative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB CT.

of Hartford, CT have inspected the pump, or valve, described in this Data Report on 1

7

/

,and state that to the best of my knowledge and belief, the CertificatO Holder has constructed this pump, or valve, in accoildance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date 7Signed Commissions

/V6 5V7 uthorized Nuclear InspecNa l

ot'. Bd. (icl. endorsements) and state or prov. end no.)

.3

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 Pg. 1 of

1. Manufactured and certified by Flowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N Certificate Holder)
2. Manufactured for Pacific Gas & Electric Company, P.O. Box 7760, San Francisco, CA 94120-7760 (name and address of Purchaser)
3. Location of installation " Diablo Canyon Power Plant, 800 Price Canyon Rd., Pismo Beach, CA 93449 (name and address)
4. Model No., Series No., or Type 1878# GLOBE VALVE Drawing W9424267 Rev.

G CRN N/A

5. ASME Code, Section Il1, Division 1:

1986 NO 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6. Pump or valve Valve.

Nominal inlet size 3/4 Outlet size 3/4 (in.)

(in.)

7. Material:

(a) valve (b) pump A747-CB7-Cu1-H1100 Body SA351-CF8M Bonnet N/A Disk Bolting NLA Casing Cover Bolting (a)

Cert..

Holder's Serial No.

91BNT 92BNT 93BNT 94BNT 95BNT 96BNT 97BNT 98BNT 99BNT 01BNU (b)

Nat'l Board No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (ci Body/Casing Serial No.

N5534-11 N5534-12 N5534-13 N5534-14 N5534-15 N5534-16 N5534-17 N5534-18 N5534-19 N5534-20 (dl Bonnet/Cover Serial No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (e)

Disk Serial No.

6934-39 6934-40 6934-41 6934-42 6934-43 6934-44 6934-45 6934-46 6934-47 6934-48

  • Supplemental information in the form of lists, sketches, or drawings may be used provided (I)-size is BW/

2 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

it

FORM NPV-1 (Back -

Pg. 2 of N.

)

9 1BHT THRU 99BNT 01BNU Certificate Holder's Serial No.

8, Design conditions 2735 psi 680

'F or valve pressure class 1878 (pressure)

(temperature)

9. Cold working pressure 4507 psi at 1 00F 6775 4960
10. Hydrostatic test psi.

Disk differential test pressure psi

11. Remarks: S.0. 53099-01 CERTIFICATION OF DESIGN Design Specification certified by Floyd A.,Bensinger P.E. State PA Reg. no. PE-31002-E Design. Report certified by Ron S. Farrell P.E. State NC Reg. no. 028656 CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

26 N Certificate of Authorization No.

N-1562 Expires Date Name Flowserve Corporation Signed (N Certificate Holder)

(authorized repres~rtstv CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB CT of Hartford, CT have inspected the pump, or valve, described in this Data Report on (a I O

, and state that to the best of my, knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any' personal' injury or property damage or a loss of any kind arising from or connected with this inspection..

Date 6,

Si ned Commissions

-(Au rzed Nuclear Inspe r (Nat. Bd. (mcl. endorsements) and state or prov. and no.)

FORM NPV-1 CERTIFICATE HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1.

2 Pg. 1 of

1. Manufactured and certified by Flowserve Corporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N Certificate Holder)
2. Manufactured for Pacific Gas & Electric Company, P.O. Box 7760, San Francisco, CA 94120-7760 (name and address of Purchaser)
3. Location of installation Diablo Canyon Power Plant, 800 Price Canyon Rd., Pismo Beach, CA 93449 (name and address)
4. Model No., Series No., or Type 1878# GLOBE VALVE Drawing W9424267 Rev.

G CRN N/A

5. ASME Code,Section III, Division 1:

1986 NO 1

N/A (edition)

(addenda date)

(class)

(Code Case no.)

6. Pump or valve Valve Nominal inlet size 3/4 Outlet size 3/4 (in.)

(in.)

7.. Material:

(a) valve Body SA351-CF8M Bonnet N/A (b) pump Casing Cover

. A747-CB7-Cu1-H 1100 Disk Bolting N/A Bolting (a)

Cert.

Holder's Serial No.

02BNU 03BNU 04BNU 05BNU 06BNU 07BNU 08BNU 09BNU 1OBNU 11BNU 12BNU 13BNU 14BNU 15BNU 16BNU 81BNT 82BNT 83BNT 84BNT 85BNT.

86BNT 87BNT 88BNT 89BNT 90BNT (b)

Nat'l Board No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A, N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (c)

Body/Casing Serial No.

N5534-21 N5534-22 N5534-23 N5534-24 N5534-25 N5522-17 N5522-18 N5522-19 N5522-20 N5522-21 N5522-22 N55221 23 N5522-24 N5522-25 N5522-26 N5534-1 N5534-2 N5538-26 N5534-4 N5534-5 N5534-6 N5534-7 N5534-8 N5534-9 N5534-10 (d)

Bonnet/Cover Serial No.

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A (e)

Disk Serial No.

6934-59 6934-60 6934-61 6934-62 6934-63 6934-49 6934-50 6934-51 6934-52 6934-53 6934-54.

6934-55 6934-56 6934-57 6934-58 6934-29 6934-30 6934-31 6934-32 6934-33 6934-34 6934-35 6934-36 6934-37 6934-38 Supplemental information in the form of lists, sketches, or drawings may~be used provided (1) size is 81/ 2 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

r7 ftL 2

FORM NPV-1 (Back -

Pg. 2 of __B

  • 02BNU -THRU 16BNU 81BNT ThRU 90BNT Certificate Holder's Serial No.

___________9_BNT

8. Design conditions 2735 psi 680

'F or valve pressure class 1878 (pressure)

(temperature)

9. Cold working pressure 4507 psi at 100°F 6775 4960
10. Hydrostatic test psi.

Disk differehtial test pressure psi

11. Remarks: S.0. 53099T01 CERTIFICATION OF DESIGN Design Specification certified by Floyd A. Bensinger PE. State PA Reg. no PE-31002-E Design Report certified by Ron S. Farrell P.E. State NC Reg. nro.

CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N Certificate of Authorization No.

N-1562 Expires 11-26-09 Dae Na Flowserve Corporation (N Certificate Holder)

(author sentative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB,CT of

Hartford, 0T have inspected the pump, or valve, described in this Data Report on (0' I O19

,and state that to the'best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date

(

Signed.

Commissions

/e'Idce m

an

ýA*ýTzc Nucea Nfl d,(ic enore ens an tate or p..... ad noo.)

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Date 1/25/10 Sheet 1

of I

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Residual Heat Removal System (10)

5. (a) Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 (c) Addenda, Code Case N/A
6. Identification of components..

I I"

ASME Name of Name of Manufacturer National Work Other Corrected, Code Serial Board Identification Removed, or Stamped Component Manufacturer No.

No.

No.

Line No Built Installed (Yes or No)

RV-8707 (spare)

Crosby Valve RV-2-8707-PEG N/A 60015550 S/C D942513 Unk Installed (1)

El No Line-7169 PG&E N/A N/A 68004433 Line-7169-18" 2009 Installed (2)

Z]

No Line-7173 PG&E N/A N/A 68004434 Line-7173-18" 2009 Installed (2) j]

No 414-842A PG&E N/A N/A 68005925 Line-7169-18" 2009 Installed (3)

El No 414-843A PG&E N/A N/A 68005926 Line-7173-18" 2009 Installed (3)

El No

7. Description of Work (1) Replacd RV nozzle during rebuild. (2) Installed Void accumulation header and assoc piping.

(3) Installed new Class-2 support.

8. Tests Conducted:,

Hydrostatic E]

Pneumatic E]

Nominal Operating Pressure 2 Exempt D

Other 0

Pressure 350 PSIG Test Temp.

250

'F

9. Remarks CERTIFICATE OF COMPLIANCE I certify that the statements made in thexreport are correct and thikt this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp N/A caorization No.

N/A Expiration Date N/A Signed

/., TT-u Engineering Manager 2/.-/i L (Owner or Owner'sDesignee)

Pktiik Nugent (Title)

(Date)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the In tor nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising frgt ý1=ctef wi this inspection.

  • /

Inspector i(

/)

Commissions CA 1828 -NB 9990 A.N.I.C Ken*'p.

Kim (Title)

(Date)

(State or Province, National Board)

Note: Supplefliental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Date 1/25/10 Sheet 1

of 2

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc, Component Cooling Water System (14)
5. (a),Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -
6. Identification of components.

Addenda, Code Cases N/A

2001, 03 (c) Addenda, Code Case N/A "II ASME Manufacturer National Other
Correctd, Code Name of Name of Work Order Year Serial Board N

Identification Removed, or Stamped No.

No.

Line No Installed (Yes or No)

CCW-2-245 Fisher Cont'ls BF184878 N/A 60006688 Line-2211-6" 1985 Installed (1)(2)

El No 72-57SL Anchor-Darling 57 N/A 60020226 Line-2342 1985 Installed (3)

E0 No Line-148 PG&E N/A N/A 68001248 Line-148-10" 1985 Removed (4)* j No Line-149 PG&E N/A N/A 68001248 Line-149-10" 1985 Removed (4)* j No

7. Description of Work (1) Replace internals. (2) Replaced bolting. (3) Replaced snubber. (4) Remove piping (cut & cap).

i

8. Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure Z Exempt LI Other LI Pressure see rink's PSIG Test Temp.

OF

9. Remarks

(*) CCW discharge press = 100 psig.

(**) Press at CCWF1 = 92 psig.

........................................................... -I - -- - - - - -- - - - - -- - - - - -- - - - -- - -

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp N/A fication No.

N/A Expiration Date N/A Signed 4qam Engineering Manager 2-X ?-/I /

(Owner or Owner'sDesignee) v Patrick Nugent (]

(Title)

(Date)

CERYIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither~he Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arisin.onrcad with this inspection.

Inspector

-/ --/i Commissions CA 1828 - NB 9990 A.N.I.C

,,:,Kenny I-k.im (Title)

(Date)

(State or Province, National Board)

Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company
2. Plant 77 Beale Street, San Francisco, CA 94106 Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424 Date 1/25/10 Sheet 2

of 2

Unit 2

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Component Cooling Water System (14)

5. (a) Applicable Construction Code See Work Order 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 Addenda, Code Case N/A
6. Identification of components.

ASME Name of Name of Manufacturer National Work Other Corrected, g

C Serial Board Order Identification Removed, or Code Component Manufacturer j

N.LnNo Built Itaed Stamped No.

No. N No.

Line No No)Installed

(

o Line7108 PG&E N/A N/A 68001250 Line-7108-2" 2008 Installed (5)*

No Line-7109 PG&E N/A N/A 68001250 Line-7109-2" 2008 Installed (5)*

0 No 326-344R PG&E N/A N/A 68001250 Line-7108-2" 2008 Installed (6)

El No

& 7109-2" Line-7108-2" 326-345R PG&E N/A N/A 68001250

& 7109-2" 2008 Installed (6)

El No 414-840R PG&E N/A N/A 68001303 Line-149-10" 2008 Installed (6)

El No 326-364A PG&E N/A N/A 68002744 Line-7130-2" 2009 Installed (6)

El No

& 713 1-2" 20 ntle 6

l N

CCW Side CCWF1 Energy Steel &

N33777-2 N/A 68002744 Stream Filter 2009 Installed (7) **

0 No Supply Housing 2-1

7. Remarks (continued)

(5) Installed piping.

(6) Installed new pipe support.

(7) Install new filter housing and assoc piping.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner
2. Plant Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106 Diablo Canyon Power Plant P.O. Box 56, Avila Beach, CA 93424 Date 1/25/10 Sheet 1

of I

Unit 2

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Makeup Water System (16))

5. (a) Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 (c) Addenda, Code Case N/A
6. Identification of components.

IASME Name of Name of Manufacturer National Work Order Other Year Corrected, Code Serial Board N

Identification Removed, or Stamped No.

No.

Line No Installed f

(Yes or No) 92-134R PG&E N/A N/A 60010694 Line-384-4" 1985 Installed (1)

E_

No

7. Description of Work (1) Modify support (welded attachment).
8. Tests Conducted:

Hydrostatic ED Pneumatic El Nominal Operating Pressure El Exempt F1 Other LI Pressure PSIG Test Temp.

OF

9. Remarks CERTIFICATE OF COMPLIANCE i certify that the statements made in the report are correct and that this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp N/

Ce C

of Authorization No.

N/A Expiration Date N/A Signed

,*Kn Z.--1/

Engineering Manager 2-/

6 (Owner or Owner'sDesignee)

PatricX,ýNugent (Title)

(Date)

V CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising ý1 t

with this inspection.

Inspector Commissions CA 1828 - NB 9990 A.N.I.C

" K D. *im (Title)

(Date) '

(State or Province, National Board)

Note: Supp1e'mental sheets in the form of lists, sketches, or drawings may be used provided (1)'size is 8 1/2 x 11 in., (2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Date 1/25/10 Sheet 1

of I

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Saltwater System (17)

Repair Org. P.O. No., Job No., etc.

5. (a) Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -
6. Identification of components.

Addenda, Code Cases N/A

2001, 03 (c) Addenda, Code Case N/A MF ASME Manufacturer National Other Y

Corrected, Code Nomeno Name Serial Board Wor Identification Removed, or Stamped No.

No.

Line No Installed f

(Yes or

_No) 414-498R PG&E N/A N/A C0212065 Line-5199-4" Unk Installed (1)

El No SW-2-55 Fisher BE701 N/A 60002225 Line-687-24" 1985 Installed (2) (N)

[

No Controls Co.

7. Description of Work (1) Replace clamps and bolting hardware.

(2) Replaced valve.

(N) New item. Code Data Report attached.

8. Tests Conducted:

Hydrostatic El Pneumatic El Nominal Operating Pressure Z Exempt

[1 Other D

Pressure 47 PSIG Test Temp.

NOT

'F

9. Remarks CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct anq that this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp N/A erti

'e uthorization No.

N/A

'Expiration Date N/A Signed

.z Engineering Manager

--/ZI,1o (Owner or Owner'sDesignee)

'--Patridk Nug*'7 (Title)

(Date)

CF)RTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising r

ed ith this inspection.

=

Inspector Commissions CA 1828 - NB 9990 A.N.I.C enny DAKim (Title)

(Date)

(State or Province, National Board)

Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11 in., (2) information in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NPV-1 CERTIFICATE; HOLDERS' DATA REPORT FOR NUCLEAR PUMPS OR VALVES*

As Required by the Provisions of the ASME Code,Section III, Division 1 2

Pg. 1 of

1. Manufactured and certified by Flowserve'Corporation, 1900 South Saunders St. Raleigh, NC 27603 (name and address of N CertificateHolder)
2. Manufactured for Pacific Gas & Electric Company, P.O. Box 7760, San Francisco, CA 94120-7760 (name and address of Purchaser)
3. Location of installation Diablo Canyon Power Plant, 800 Price Canyon Rd., Pismo Beach, CA 93449 (name and address)
4. Model No., Series No., or Type 150 BF DrawingO6-426SS-0 3 Rev. C CRRN N/A
5. ASME Code,Section III, Division 1:

1989 NO Addenda 3

N-133-3 (edition)

(addenda date)

(class)

(Code Case no.)

6. Pump or valve Valve Nominal inlet size 24" Outlet size 24" (in.)(in.)
7. Material:

(a) valve BodýSB1 4B C95400 Bonnet N/A Disk SB148 C95400 Bolting N/A (b) pump Casing Cover Bolting (a)

Cert.

Holder's Serial No.

BE701 BE702 (b)

Nat'I Board No.

N/A N/A (c)

Body/Casing Seria I No.

07606-7591 07605-Z592 (d)

Bonnet/Cover Serial No.

N/A N/A (e)

Disk Serial No.

07207-Z194 07206-Z190

  • Supplemental information in the form of lists, sketches, or drawings may be used provided (1) size is 81/2 x 11, (2) information in items 1 through 4 on this Data Report is included on each sheet, (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

2 FORM NPV-1 (Back -

Pg. 2 of 2 BE701 & BE-702 Certificate Holder's Serial No. BE701_&_BE702

8. Design conditions 230 psi (0t

'F or valve pressure class 150 (pressure)

(temperature)

9. Cold working pressure 230 psi at 1 00°F 350 255
10. Hydrostatic test psi.

Disk differential test pressure psi

11. Remarks:

SO 42655-3, 24" 150 BUTTERFLY VALVE CERTIFICATION OF DESIGN

/

KER5I]3. DALAL CA M-16690 Design Specification certified by P.E. State C

Reg. no.

M_16690 Design Report certified by N/A P.E. State N/A Reg. no.

N/A CERTIFICATE OF COMPLIANCE We certify that the statements made in this report are correct and that this pump or valve conforms to the rules for construction of the ASME Code,Section III, Division 1.

N-1562 I

_26J N Certificate of Authorization No.

Expires 11 Date h

Name Flowserve Corporation Signed (N Certificate Holder)

{authorize rpresentative)

CERTIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of NC and employed by HSB CT o Hartford, CT have inspected the pump, or valve, described in this Data Report on

/and state that to the best of my knowledge and belief, the Certificate Holder has constructed this pump, or valve, in accordance with the ASME Code,Section III, Division 1.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the component described in this Data Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Date Signed

-Commissions A-ýC---4/,i lAutiorized Nuclear Inspec or)

[Nat'. Bd. (inc. endorsements) and state or prov. and no.)

3 7

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Date 1/25/10 Sheet 1

of 2

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Repair Org. P.O. No., Job No., etc.

Diesel Engine Generator System (21)

5. (a) Applicable Construction Code (See Work Order) 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 (c) Addenda, Code Case N/A
6. Identification of components.

TASME Name of Name of Manufacturer National Work Order Other Y

corrected, Code Serial Board N

Identification Removed, or

?

Stamped Component Manufacturer No.

No.

No.

Line No iInstalled (Yes or No)

JWPI ALCO 259002 N/A 60001841 DEG2-1 1992 Installed (1) 0 No Power Inc.

JW pump

/

ALCO DEG 2-3 DEG2-3JW Power Inc.

N/A N/A 60018822 Jacket Water Unk Installed (2) 0 No ALCO DEG 2-I DEG 2-1 JW Power Inc.

N/A N/A 64005093 Jacket Water Unk Installed (3)

El No

7. Description of Work (1) Replace Jacket Water pump with refurbished spare. (2) Replace couplings, clamps and bolting.

(3) Replace expansion tank cap.

8. Tests Conducted:

Hydrostatic El Pneumatic F1 Nominal Operating Pressure Z Exempt D1 Other

[]

Pressure 48 PSIG Test Temp.

NOT

'F

9. Remarks CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this comforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp N/A C

C fica horization No.

N/A Expiration Date N/A Signed Engineering Manager 2/-/I 0

(Owner or Owner'sDesignee)

Patrick Nugeo V (Title)

(Date)

CEIrIFICATE OF INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of California, And employed by HSB-CT of Hartford, CT have inspected the components described in this Owner's Report during the period 5/13

,2008 to 12/10

,2009 and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures, described in the Owner's Report in accordance with the requirements of the ASME Code,Section XI. By signing this certificate, neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.

Furthermore, neither the Ins ctor nor his employer shall be liable in any manner for any personal injury or property damage or loss of any kind arising fro o

ted ith is inspection.

Inspector Commissions CA 1828 - NB 9990 A.N.I.C

/Kenn,.

(Title)

(Date)

(State or Province, National Board)

Note: Suppl ental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 8 1/2 x 11 in., (2) information in items 1 through 6-n this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

FORM NIS-2 OWNER'S REPORT OF REPAIR OR REPLACEMENT ACTIVITY As Required by the Provisions of the ASME Code Section XI

1. Owner Pacific Gas and Electric Company 77 Beale Street, San Francisco, CA 94106
2. Plant Diablo Canyon Power Plant Date 1/25/10 Sheet

.2 of 2

Unit 2

P.O. Box 56, Avila Beach, CA 93424

3. Work Performed by
4. Identification of System Owner See Above Diesel Engine Generator System (21)

Repair Org. P.O. No., Job No., etc.

5. (a) Applicable Construction Code See Work Order 19 Edition (b) Applicable Edition of Section XI Utilized for Repairs or Replacements -

Addenda, Code Cases N/A

2001, 03 Addenda, Code Case N/A
6. Identification of components.

I I II-*

ASME Manufacturer National Work Other Corrected, 9

Name of Name of Year Code Component IManufacturer Serial Board Order Identification Removed, or S

NaeofNmeoen oMaManfacturer Nationa WokSter Yar CrrcedpeCde No.

No.

No.

Line No Installed (Yes or No)

ALCO Power DEG 2-2 DEG 2-2 JW Inc.

N/A N/A 64005093 Jacket Water Unk Installed (3)

El No DEG 2-3 JW ALCO Power N/A N/A 64005095 DEG 2-3 Unk Installed (3)

El No Inc.

Jacket Water DEG 2-3 JW ALCO Power N/A N/A 64005099 DEG 2-3 Unk Installed (2) 0 No Inc.

Jacket Water ALCO Power DEG 2-1 DEG 2-1 JW Inc.

N/A N/A 64005099 Jacket Water Unk Installed (2) 0 No

7. G Rem s

(

d (ALCO Power coplNgs clampsDEG 2-2 blg Instank cap.

DE 22 WInc.

N/

/

4010 Jacket Water Uk Intle(2

]

o El,

7. Rmars (ontnued (2 Relac coplins, lams ad botin. () Rplae exanson ankcap I