BVY 04-117, Emergency Response Data System (ERDS) Data Point Library Update

From kanterella
Jump to navigation Jump to search
Emergency Response Data System (ERDS) Data Point Library Update
ML043060496
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 10/26/2004
From: Devincentis J
Entergy Nuclear Northeast, Entergy Nuclear Operations
To:
Document Control Desk, Office of Nuclear Security and Incident Response
References
BVY 04-117
Download: ML043060496 (73)


Text

' Entergy Entergy Nuclear Northeast Entergy Nuclear Operations, Inc.

Vermont Yankee 185 Old Ferry Rd.

P.O. Box 500 Brattleboro, VT 05302 Tel 802-257-5271 October 26, 2004 Docket No. 50-271 BVY 04-117 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

Subject:

Vermont Yankee Nuclear Power Station Emergency Response Data System (ERDS)

Data Point Library Update Vermont Yankee has recently reviewed the entire ERDS Data Point Library to verify the accuracy of the listed Alarm/Trip Set Points. We have corrected a number of Alarm Set Points listed in the library that were found out of date and have taken the opportunity to re-format the entire document for consistency. We have enclosed a copy for your use.

There are no new commitments being made in this submittal.

If you have any questions or require additional information, please contact me at (802)258-4236 Sincerely, sM. DeVincentis Manager, Licensing Attachment (1) cc: (next page)

AOC~2Y(D

BVY 04-117 Docket No. 50-271 Page 2 of 2 cc:

Mr. Richard B. Ennis, Project Manager -

Project Directorate I Division of Licensing Project Management Office of Nuclear Reactor Regulation Mail Stop 0 8 B1 Washington, DC 20555 Mr. Samuel J. Collins Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 USNRC Resident Inspector Entergy Nuclear Vermont Yankee, LLC P.O. Box 157 Vernon, Vermont 05354 Mr. David O'Brien, Commissioner VT Department of Public Service 112 State Street - Drawer 20 Montpelier, Vermont 05620-2601 Mr. Tom Kardaras NRC ERDS Project Officer Mail Stop T 4L 7 11545 Rockville Pike Rockville, Maryland 20852

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS NI POWER RNG C203 Reactor Power Computed Average Nuclear Instruments, Power Range A

% PWR N/A 0

125 N/A N/A P

6 Average, See Below Reactor In-Core Variable High Alarm, Flow-Biased N/A N/A Variable N/A N/A Average of non-bypassed Average Power Range Monitors.

Page 1 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS NI INTER RNG M072 IRM D Nuclear Instrument, Intermediate Range A

N/A 0

100 Variable Several Selective Ranges S

I N/A Reactor In-Core N/A N/A N/A Variable N/A N/A Single fission chamber detector, remotely moveable within core. Five decades of indication over ten ranges. 100% on range 10 equals 31.25%

core thermal power when fully inserted.

Page 2 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS NI SOURC RNG M080 SRM Channel A Nuclear Instruments, Source Range A

C/S N/A 0.1 2.928,647 Variable Several ranges selectable by positioning detector.

S 1

N/A Reactor In-Core N/A N/A N/A Variable N/A N/A Single fission chamber detector remotely moveable within core. Provides one decade of overlap to intermediate range detectors.

Page 3 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS NI SOURC RNG M081 SRM Channel B Nuclear Instruments, Source Range A

C/S N/A 0.1 2,928,647 Variable Several ranges selectable by positioning detector.

S N/A Reactor In-Core N/A N/A N/A Variable N/A N/A Single fission chamber detector remotely moveable within core. Provides one decade of overlap to intermediate range detectors.

Page 4 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS NI SOURC RNG M082 SRM Channel C Nuclear Instruments, Source Range A

C/S N/A 0.1 2,928,647 Variable Several ranges selectable by positioning detector.

S 1

N/A Reactor In-Core N/A N/A N/A Variable N/A N/A Single fission chamber detector remotely moveable within core. Provides one decade of overlap to intermediate range detectors.

Page 5 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS NI SOURC RNG M083 SRM Channel D Nuclear Instruments, Source Range A

C/S N/A 0.1 2,928,647 Variable Several ranges selectable by positioning detector.

S I

N/A Reactor In-Core N/A N/A N/A Variable N/A N/A Single fission chamber detector remotely moveable within core. Provides one decade of overlap to intermediate range detectors.

Page 6 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS ROD DENSITY Cl 16 Control Rod Density Fraction I

Control Rods Inserted A

Fraction N/A 0

All Rods Out N/A P

20 RPIS Interface Reactor In-Core N/A N/A N/A N/A N/A N/A Rod positions are digitally encoded by the RPIS system and decoded by the process computer. A rod density calculation is then performed.

Page 7 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS SLC LEVEL P009 Standby Liquid Control Tank Percent of Level Standby Liquid Control Tank Percent of Level A

% Level Linear Signal to E.U. Conversion 0

100 Bottom Pressure Tap N/A S

I N/A Standby Liquid Control Tank. Reactor Building N/A N/A N/A Variable N/A N/A N/A Page 8 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS SLC PRESSURE Polo Standby Liquid Control Discharqe Pressure Standby Liquid Control Discharge Pressure A

PSIG Linear Signal to E.U. Conversion 0

2000.0 RB Ambient N/A S

I N/A Standby Liquid Control System. Reactor Building N/A N/A N/A Variable N/A N/A N/A Page 9 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REAC VES LEV C201 RPV Water Level Computed Reactor Vessel Water Level A

Inches N/A 187 77 Fuel TAF N/A P

6 See Below Drywell 127 = Lo Alarm N/A N/A N/A N/A N/A Trip Hi = 177, Scram Lo = 127, ECCS initiate = 82.5, 2/3 core height = -48.

An accuracy-weighted average of the four ECCS range sensors is used unless range is exceeded. If exceeded, transient range B043 & B047 used.

Page 10 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REAC VES LEV B046 LI-2-3-91 A Reactor Vessel Water Level A

Inches N/A

-200 200 TAF N/A S

1 N/A Reactor Buildinq Provides 2/3 core height interlock to LPCI mode of RHR N/A N/A Variable N/A Wet Reactor vessel shroud level indicator. Calibrated for cold, no drive flow conditions at 212 deqF vessel, non-steaming, 100 deqF in drywell and 100 deqF in Reactor Buildinq. Tech Spec Post Accident Instrument.

Page 11 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS MAIN FD FLOW B015 Reactor Feedwater Inlet Flow A Feedwater Flow into the Reactor System A

MLB/HR N/A 0

5 N/A N/A S

1 N/A Turbine Building 3.4 Hi Alarm N/A N/A Variable Density compensation applied: ref. conditions 391.5 deqF & 1025 psia Y

N/A Page 12 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARMITRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS MAIN FD FLOW B016 Reactor Feedwater Inlet Flow B Feedwater Flow into the Reactor System A

MLB/HR N/A 0

5 N/A N/A S

I N/A Turbine Building 3.4 Hi Alarm N/A N/A Variable Density compensation applied: ref. conditions 391.5 deqF & 1025 psia Y

N/A Page 13 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RCIC FLOW P007 RCIC Flow Reactor Core Isolation Cooling Flow A

GPM N/A 0

500 N/A N/A S

1 N/A Reactor Building N/A N/A N/A Variable N

N/A Injection flow into feedwater line or Full Flow Test to Condensate Storage Tank.

Page 14 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS CORE FLOW B01 2 Total Core Flow Total Core Flow A

MLB/HR Linear Signal to E.U. Conversion 0

80 N/A N/A S

1 N/A Drywell Hi Alarm = 51.5 N/A N/A Variable N/A N/A N/A Page 15 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RCS PRESSURE C202 Reactor Pressure Computed Reactor Coolant Systems Pressure A

PSIG N/A 0

1500 Reactor Building Pressure N/A IP 3

Weighted Average Reactor Building Hi 1055 Alarm N/A N/A N/A N/A N/A Reactor pressure computed is a weighted average of one, two or three pressure sensors.

Page 16 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERICICOND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RCS PRESSURE B049 PI-2-3-56A Reactor Coolant System Pressure A

PSIG N/A 0

1500 Reactor Building Pressure N/A S

I N/A Reactor Building Hi Alarm 1035 N/A N/A Variable N/A N/A PI-2-3-56A EnvironmentaliV qualified for post-accident use.

Page 17 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS HPCI FLOW P008 HPCI Flow High Pressure Coolant Iniection Flow A

GPM N/A 0

5000 N/A N/A S

1 N/A Reactor Buildinq N/A N/A N/A Variable N

N/A Injection flow into Feedwater Line A or Full Flow Test to Condensate Storage Tank.

Page 18 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS LPCI FLOW Pool RHR System Flow A Low Pressure Coolant Injection Flow A

GPM N/A 0

20,000 N/A N/A S

1 N/A Reactor Building N/A N/A N/A Variable N

N/A Environmentally qualified for post-accident use.

Page 19 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS LPCI FLOW P002 RHR System Flow B Low Pressure Coolant Iniection Flow A

GPM N/A 0

20 000 N/A N/A S

1 N/A Reactor Buildinq N/A N/A N/A Variable N

N/A Environmentally aualified for nost-accident use.

Page 20 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS CR SPRAY FL Pol1 Core Spray Flow A Core Spray Cooling System Flow A

GPM N/A 0

1000 N/A N/A S

1 N/A Reactor Buildinq N/A N/A N/A Variable N

N/A Vessel Injection of Full Flow Test Indication.

Environmentally qualified for post-accident use.

Page 21 of 71

- DATA POINT LIBRARY R'EFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS CR SPRAY FL P012 Core Spray Flow B Core Spray Cooling System Flow A

GPM N/A 0

1000 N/A N/A S

1 N/A Reactor Building N/A N/A N/A Variable N

N/A Vessel Injection or Full Flow Test Flow Indication.

Environmentally qualified for post-accident use.

Page 22 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:'

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS EFF GAS RAD U014 Stack Gas III Mon Hi Range Radioactivity of Released Gases A

MR/HR N/A 0.1 10,000,000 No Activity N/A S

I N/A Offqas stack base.

12 Hi Alarm N/A N/A Variable N/A Ion chamber sensing a representative sample of gases being released via the 100 meter plant stack. Environmentally qualified for post-accident use.

Page 23 of 71

r 13TF - DATA POINT LIBRARY R'.EFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS EFF GAS RAD M001 Stack Gas Monitor I Radioactivity of Released Gases A

CPM N/A 10 10.000,000 No Activitv N/A S

1 N/A Offgas Stack 1000 Hi Alarm N/A N/A Variable N/A N/A Scintillation detector sensing a representative sample of gases being released via the 100 meter plant stack.

Page 24 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS EFF GAS RAD U01 3 Stack Gas Monitor II Radioactivity of Released Gases A

CPM N/A 1.67 1,427,989 No Activitv N/A S

I N/A Offgas Stack 1000 Hi Alarm N/A N/A Variable N/A N/A Scintillation detector sensinq a representative sample of gases being released via the 100 meter plant stack.

Page 25 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS CND A/E RAD M002 SJAE OFF GAS Activity Condenser Air Eiector Radioactivitv A

MR/HR N/A 0.562 1,000.000 No Activity N/A S

1 N/A Turbine Building 250 Hi Alarm N/A N/A Variable N/A N/A Ion chamber detector sensing air and non-condensed gases extracted from the main condenser and beinq discharged to the advanced - off gas holdup system.

Page 26 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS DW RAD C21 0 Drywell Radiation Computed Radiation Level in the Drvwell A

R/HR N/A 1

10,000,000 No ActivitV N/A P

2 Highest Drywell 5 Hi Alarm N/A N/A N/A N/A N/A Ion chamber sensing drywell general area radiation levels. Drywell radiation computed is the higher valid containment high range radiation monitor.

Page 27 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS MN STEAM RAD M120 Steam Line Rad A Radiation Level of the Main Steam Line A

MR/HR N/A 0.562 1,000,000 No Activity N/A S

I N/A Steam Tunnel 580 Hi Alarm. (typically 3X Background)

N/A N/A Variable N/A Ion chamber sensing gamma radiation from the main steam lines as they exit the primary containment. Provides automatic isolation signal.

Page 28 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS MN STEAM RAD M121 Steam Line Rad B Radiation Level of the Main Steam Line.

A MR/IHR N/A 0.562 1,000,000 No Activity N/A S

1 N/A Steam Tunnel 580 Hi Alarm. (tvDicallv 3X Backaround)

N/A N/A Variable N/A N/A Ion chamber sensing gamma radiation from the main steam lines as thev exit the primary containment. Provides automatic isolation signal.

Page 29 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS MN STEAM RAD M122 Steam Line Rad C Radiation Level of the Main Steam Line A

MR/HR N/A 0.562 1.000.000 No Activity N/A S

I N/A Steam Tunnel 580 Hi Alarm. (typically 3X Background)

N/A N/A Variable N/A N/A Ion chamber sensing gamma radiation from the main steam lines as they exit the primary containment. Provides automatic isolation signal.

Page 30 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS MN STEAM RAD M123 Steam Line Rad D Radiation Level of the Main Steam Line A

MR/HR N/A 0.562 1,000,000 No Activity N/A S

1 N/A Steam Tunnel 580 Hi Alarm. (typically 3X Background)

N/A N/A Variable N/A N/A Ion chamber sensing gamma radiation from the main steam lines as thev exit the primary containment. Provides automatic isolation signal.

Page 31 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RR VENT RAD M126 RB Vent Exh. Rad Mon A RB Vent Rad A

MR/HR Antiloq Signal to E.U. Conversion 0.1 1,000 No Activity N/A S

1 N/A Reactor Buildinq Vent N/A N/A N/A Variable N/A N/A N/A Page 32 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RB VENT RAD M127 RB Vent Exh. Rad Mon B RB Vent Rad A

MR/HR Antilog Signal to E.U. Conversion 0.1 1,000 No Activity N/A S

1 N/A Reactor Building Vent N/A N/A N/A Variable N/A N/A N/A Page 33 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M000 ARM North Personnel Access Sta 2 Reactor Building Radiation A

MR/HR Antilog Signal to E.U. Conversion 0.1 1000 No Activity N/A S

1 N/A Reactor Building North Personnel Access 100 Hi Alarm N/A N/A Variable N/A N/A N/A Page 34 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NJ DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M043 ARM RB 232 EL Torus Sta 1 Reactor Building Radiation A

MR/HR Antilog Signal to E.U. Conversion 1

10,000 No Activity N/A S

I N/A Reactor Buildinq 232 Ft. Elevation, near Torus 100 Hi Alarm N/A N/A Variable N/A N/A N/A Page 35 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M048 ARM RB 252 North Personnel Access Reactor Bldg. Radiation - High Range A

R/HR Antilog Signal to E.U. Conversion I

10.000 No ActivitV N/A S

1 N/A Reactor Building 252 Ft. Elevation, by North Personnel Access Hi Alarm = 2 N/A N/A Variable N/A N/A High Range Reactor Buildinq Radiation Page 36 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARMITRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M049 ARM RB 252 West Personnel Access Reactor Building Radiation - Hiah Ranae A

R/HR Antiloq Signal to E.U. Conversion 1

10,000 No Activity N/A S

1 N/A Reactor Building 252 Elevation by West Personnel Access High Alarm = 2 N/A N/A Variable N/A N/A High Range Reactor Building Radiation Page 37 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M051 ARM RB 280 Elevation Sta. 6 Reactor Buildinq Radiation A

MR/HR Antilog Signal to E.U. Conversion 1

10,000 No Activity N/A S

1 N/A Reactor Building 280 Ft. Elevation Hi Alarm = 100 N/A N/A Variable N/A N/A N/A Page 38 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR RLDG. RAD M052 ARM RB 252 South RR Access Sta. 3 Reactor Buildina Radiation A

MR/HR Antilog Signal to E.U. Conversion 0.1 1000 No ActivitV N/A S

I N/A Reactor Building 252 Ft. Elevation, by South RR Access High Alarm = 100 N/A N/A Variable N/A N/A N/A Page 39 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS NRC ERDS PARAMETER:

REACTOR BLDG. RAD POINT ID:

M053 PLANT SPEC POINT DESC.:

ARM RB 252 TIP Room Sta. 4 GENERIC/COND DESC.:

Reactor Buildinq Radiation ANALOG/DIGITAL:

A ENGR UNITS/DIG STATES:

MR/HR ENGR UNITS CONVERSION:

Antilog Signal to E.U. Conversion MINIMUM INSTR RANGE:

1 MAXIMUM INSTR RANGE:

10,000 ZERO POINT

REFERENCE:

No Activity REFERENCE POINT NOTES:

N/A PROC OR SENS:

S NUMBER OF SENSORS:

1 HOW PROCESSED:

N/A SENSOR LOCATIONS:

Reactor Building 252 Ft. Elevation by TIP Room ALARM/TRIP SET POINTS:

Hi Alarm = 100 NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

Variable TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

N/A LEVEL REFERENCE LEG:

N/A UNIQUE SYSTEM DESC.:

N/A Page 40 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

M060 ARM RB 252 CRD Repair Room Sta. 7 Reactor Building Radiation A

MR/HR Antilog Signal to E.U. Conversion I

10,000 No Activity N/A S

1 N/A Reactor Building 252 Ft Elevation, CRD Repair Room Hi Alarm = 100 N/A N/A Variable N/A N/A N/A Page 41 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M061 ARM RB 303 RWCU Sample Sta. 9 Reactor Building Radiation A

MR/HR Antiloq Signal to E.U. Conversion 1

10.000 No Activity N/A S

1 N/A Reactor Buildinq 303 Ft. Elevation by RWCU Hi Alarm = 20 N/A N/A Variable N/A N/A N/A Page 42 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M067 ARM RB EL 303 Elevator Site 8 Reactor Building Radiation A

MR/HR Antiloq Signal to E.U. Conversion 1

10,000 No Activity N/A S

1 N/A Reactor Building, 303 Ft. Elevation Hi Alarm = 100 N/A N/A Variable N/A N/A N/A Page 43 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M068 ARM RB EL 318 Elevator Sta. 10 Reactor Building Radiation A

MR/HR Antilog Signal to E.U. Conversion I

10,000 No ActivitV N/A S

1 N/A Reactor Building, 318 Ft. Elevation, by elevator Hi Alarm = 100 N/A N/A Variable N/A N/A N/A Page 44 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M073 ARM RB EL 345 West Refuel Sta 14 Reactor Building Radiation A

MR/HR Antilog Signal to E.U. Conversion 1

1,000,000 No Activity N/A S

1 N/A Reactor Building, Elevation 345 Ft. West Refueling Hi Alarm = 1000 N/A N/A Variable N/A N/A N/A Page 45 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M078 ARM RB Elevator 348 Ft Sta. 12 Reactor Buildina Radiation A

MR/HR Antilog Signal to E.U. Conversion 1

10,000 No Activity N/A S

I N/A Reactor Building, 348 Ft Elevation by Elevator Hi Alarm = 15 N/A N/A Variable N/A N/A N/A Page 46 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS NRC ERDS PARAMETER:

REACTOR BLDG. RAD POINT ID:

M128 PLANT SPEC POINT DESC.:

Refuel Floor Area Rad Mon A GENERIC/COND DESC.:

Reactor Building Radiation ANALOG/DIGITAL:

A ENGR UNITS/DIG STATES:

MR/HR ENGR UNITS CONVERSION:

Antiloq Signal to E.U. Conversion MINIMUM INSTR RANGE:

1 MAXIMUM INSTR RANGE:

10,000 ZERO POINT

REFERENCE:

No Activity REFERENCE POINT NOTES:

N/A PROC OR SENS:

S NUMBER OF SENSORS:

1 HOW PROCESSED:

N/A SENSOR LOCATIONS:

Reactor Buildinq Refuel Floor ALARM/TRIP SET POINTS:

N/A NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

N/A NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

N/A INSTRUMENT FAILURE MODE:

Variable TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

N/A LEVEL REFERENCE LEG:

N/A UNIQUE SYSTEM DESC.:

N/A Page 47 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS REACTOR BLDG. RAD M129 Refuel Floor Area Rad Mon B Reactor Building Radiation A

MR/HR Antiloq Signal to E.U. Conversion 1

10.000 No Activity N/A S

I N/A Reactor Building Refuel Floor N/A N/A N/A Variable N/A N/A N/A Page 48 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS DW PRESS C204 Drywell Pressure Computed Drywell Pressure A

PSIG N/A

-15 260 Abs 0 + 15 lbs N/A P

5 See Below Reactor Building 2.5 Trip Pt.

N/A N/A N/A N/A N/A First Range Used: Simple average for two 0-5 PSIG sensors. Next Range Used is an Accuracy Weighted Average of one -15 to 65 PSIG and two -15 to 260 PSIG sensors. Auto ranging occurs if first range is exceeded.

Page 49 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS DW TEMP C205 Drywell Area Temp Computed Drywell Temperature A

F N/A 0

781.8 N/A N/A P

2 Highest Drywell 160 Hi Alarm N/A N/A N/A N/A N/A The higher valid drywell temperature of M092 or M093 is displayed as C205.

Page 50 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS SPTEMP C207 Torus Water Temp Computed Suppression Pool Temperature A

F N/A 0

300 N/A N/A P

8 Average Torus Hi Alarm = 90. 110 = Manual Scram N/A N/A N/A N/A N/A Submerged sensors only are averaged, six are 10.4 feet from the bottom of the torus, two are 8.5 feet from the bottom of the torus. Under saturation conditions, air and water temperatures will equalize.

Page 51 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS SP LEVEL C206 Torus Water Level Computed Suppression Pool Temperature A

Feet N/A 0

25 Torus Bottom N/A P

3 Weighted Average Reactor Building Varies with DW-to-Torus DP. Hi Alarm = 11.3. Lo Alarm = 11.0 N/A N/A N/A N/A N/A Torus water level computed is a cross comparison validation algorithm of one narrow range and two wide range level sensors.

Page 52 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS H2 CONC C211 Drywell/Torus Hydrogen Concentration Drywell or Torus Hydrogen Concentration A

N/A 0

30 N/A N/A IP 2

Highest Reactor Building Hi Alarm = 0.5 N/A N/A Variable N/A N/A The higher valid hydrogen concentration of C245 or C247 is displayed as C21 1.

Page 53 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS 02 CONC C212 Drywell/Torus Oxygen Concentration Drywell or Torus OxVyqen Concentration A

N/A 0

25 N/A N/A P

2 Hiahest Reactor Buildinq Hi Alarm = 5.0 N/A N/A Variable N/A N/A The higher valid oxyven concentration of C246 or C248 is displayed as C212.

Page 54 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RB DELTA P R018 Rx Bldg. Negative Delta PSI 1 N Secondary Containment Delta Pressure A

IN H20 Linear

-2

+2 Bldg. = Barometric N/A S

I N/A Reactor Buildinq North Wall N/A N/A N/A Variable N/A N/A N/A Page 55 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RB DELTA P R01 9 Rx Bldg. Negative Delta PSI 2E Secondary Containment A

IN H20 Linear

-2

+2 Bldg. = Barometric N/A S

1 N/A Reactor Building East Wall N/A N/A N/A Variable N/A N/A N/A Page 56 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIG ITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RB DELTA P R020 Rx Building Negative Delta PSI 3S

_Sprondarv Containment Delta Pressure A

IN H20 Linear

-2

+2 Bldg. = Barometric N/A S

1 N/A Reactor Buildinq South Wall N/A N/A N/A Variable N/A N/A N/A Page 57 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS RB DELTA P R021 Rx Building Neqative Delta PSI 4W Secondary Containment Delta Pressure A

IN H20 Linear

-2

+2 Bldg. = Barometric N/A S

1 N/A Reactor Building West Wall N/A N/A N/A Variable N/A N/A N/A Page 58 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS CST LEVEL C243 Condensate Storage Tank Level Condensate Storage Tank Level A

1% = 4.771 KGAL 0

100 HPCI/RCIC Suction Line S

I N/A Condensate Storage Tank N/A N/A N/A Variable N

Wet Page 59 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS WIND SPEED C178 Lower Wind Speed - 15 Min. Avq.

Wind Srpeed at the Reactor Site A

MPH N/A 0

100 N/A N/A P

15 Minute Average Primary Meteorological Tower N/A N/A N/A Variable N/A N/A Page 60 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS WIND SPEED C179 Upper Wind Speed - 15 Min. Avg.

Wind Speed at the Reactor Site A

MPH N/A 0

100 N/A N/A P

1 15 Minute Average Primary Meteorological Tower N/A N/A N/A Variable N/A N/A Page 61 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS WIND SPEED C1 84 Backup Wind Speed 100 Ft. El. - 15 Min. Avq.

Wind Speed at the Reactor Site A

MPH N/A 0

100 N/A N/A IP I

15 Minute Average Backup Meteorological Tower N/A N/A N/A Variable N/A N/A Page 62 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS WIND DIR C1 88 Backup Wind Direction - 15 Min. Vector Avg.

Wind Direction at the Reactor Site A

Degrees From N/A 0

360 North N/A P

1 15 Min. Vector Avg.

Backup Meteorological Tower N/A N/A N/A Variable N/A N/A Page 63 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NJ DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VYI DATA FEEDER: ERFIS WIND DIR C186 Lower Wind Direction - 15 Min. Vector Avg.

Wind Direction at the Reactor Site A

Degrees From N/A 0

360 North N/A P

1 15 Min. Vector Avg.

Primary Meteorological Tower N/A N/A N/A Variable N/A N/A Page 64 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS WIND DIR C187 Upper Wind Direction - 15 Min. Vector Avq.

Wind Direction at the Reactor Site A

Degrees From N/A 0

360 North N/A ID 15 Min. Vector Avg.

Primary Meteorological Tower N/A N/A N/A Variable N/A N/A Page 65 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS STAB CLASS UOOO Backup Delta Temp 135 Ft. EL Air Stabilitv at the Reactor Site A

Delta F N/A

-5 15 Temp of Lower Sensor N/A S

N/A N/A Backup Meteorological Tower (165 Ft.)

N/A N/A N/A Variable N/A N/A Extremely Unstable T<-1.063: Moderately Unstable -1.064<-.95: Slightly Unstable -.94<T<-.84: Neutral -.83<T<-.28: Slightly Stable -.27<T<.84:

Moderately Stable.85<T<2.03: Extremely Stable 2.04<T.

Reference:

Reg. Guide 1.23. VY OP5335, VY OP5343 Page 66 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS STAB CLASS Upper Delta Temperature Air Stability at the Reactor Site A

Delta F N/A

-5 15 Temp of Lower Sensor N/A S

N/A N/A PrimarV Meteorological Tower N/A N/A N/A Variable N/A N/A Extremely Unstable <-2.74: Moderately Unstable -2.73<T<-2.45: Slightly Unstable -2.44<T<-2.16: Neutral -2.15<T<-.72: Slightly Stable -.71<T<2.15:

Moderately Stable 2.16<T<5.74: Extremely Stable 5.75 <T.

Reference:

Reg. Guide 1.23, VY OP5335, VY OP5343.

Page 67 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS SRV POS D557 SRV Discharge Pressure A SafetV Relief Valve Position D

Norm/High N/A N/A N/A N/A N/A S

1 N/A Safety Relief Valve A Tail Pipe to Torus N/A N/A N/A Variable N/A N/A N/A Page 68 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS SRV POS D558 SRV Discharge Pressure B Safety Relief Valve Position D

Norm/High N/A N/A N/A N/A N/A S

1 N/A Safety Relief Valve B Tail Pipe to Torus N/A N/A N/A Variable N/A N/A N/A Page 69 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS SRV POS D559 SRV Discharge Pressure C Safety Relief Valve Position D

Norm/High N/A N/A N/A N/A N/A S

1 N/A Safety Relief Valve C Tail Pipe to Torus N/A N/A N/A Variable N/A N/A N/A Page 70 of 71

- DATA POINT LIBRARY REFERENCE FILE DATE:

NRC ERDS PARAMETER:

POINT ID:

PLANT SPEC POINT DESC.:

GENERIC/COND DESC.:

ANALOG/DIGITAL:

ENGR UNITS/DIG STATES:

ENGR UNITS CONVERSION:

MINIMUM INSTR RANGE:

MAXIMUM INSTR RANGE:

ZERO POINT

REFERENCE:

REFERENCE POINT NOTES:

PROC OR SENS:

NUMBER OF SENSORS:

HOW PROCESSED:

SENSOR LOCATIONS:

ALARM/TRIP SET POINTS:

NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:

NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:

INSTRUMENT FAILURE MODE:

TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:

LEVEL REFERENCE LEG:

UNIQUE SYSTEM DESC.:

10/29/04 REACTOR: VY1 DATA FEEDER: ERFIS SRV POS D560 SRV Discharge Pressure D Safety Relief Valve Position D

Norm/High N/A N/A N/A N/A N/A S

1 N/A Safety Relief Valve D Tail Pipe to Torus N/A N/A N/A Variable N/A N/A N/A Page 71 of 71