Title | Failure to Perform an Adequate Extent of Condition Review for the 1C Conventional Service Water Pump Strainer |
Description | An NRC-identified Green finding of licensee procedure CAP-NGGC-0205, Condition Evaluation and Corrective Action Process, was identified for the licensees failure to perform an adequate extent of condition review for the 1C CSW pump strainer stop collar clearance issue. Specifically, between February 21, 2014, and April 8, 2015, the licensee failed to perform an adequate extent of condition to identify the 2C CSW pump strainer stop collar was also installed without being securely positioned. This resulted in the failure of the shear pin and inoperability of the 2C CSW strainer and pump. As corrective actions, the licensee replaced the shear pin securely and scheduled the replacement of the other CSW pump strainer shear pins at the earliest available work window. The licensee entered this issue into the CAP as NCR 742444. The inspectors determined that the licensees failure to perform an adequate extent of condition review for the 1C CSW pump strainer stop collar clearance issue, as required by licensee procedure CAP-NGGC-0205 was a performance deficiency. The finding was more than minor because it was associated with the equipment performance attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure the availability of systems that respond to initiating events to prevent undesirable consequences. Specifically, this resulted in the failure of 2C CSW pump strainer shear pin, and inoperability of the 2C CSW strainer and pump. Using IMC 0609, Appendix A, issued June 19, 2012, the SDP for Findings At-Power, the inspectors determined the finding was of very low safety significance (Green) because the finding did not affect the design or qualification of a mitigating SSC, the finding did not represent a loss of system and/or function, the finding did not represent an actual loss of a function of a single train for greater than the TS allowed outage time, the finding did not represent an actual loss of a function of one or more non-TS trains of equipment, and did not screen as potentially risk-significant due to a seismic, flooding, or severe weather initiating event. The finding has a cross-cutting aspect in the area of problem identification and resolution associated with the evaluation attribute because the licensee failed to thoroughly evaluate issues to ensure that resolutions address causes and extent of conditions commensurate with their safety significance. Specifically, the licensee failed to evaluate the applicability of the stop collar clearance issue to the other strainers after the failure of the 1C CSW pump strainer shear pin. [P.2] |
Site: | Brunswick |
---|---|
Report | IR 05000324/2015002 Section 1R19 |
Date counted | Jun 30, 2015 (2015Q2) |
Type: | Finding: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.19 |
Inspectors (proximate) | G Hopper M Catts M Orr M Riches M Schwieg |
CCA | P.2, Evaluation |
INPO aspect | PI.2 |
' | |
Finding - Brunswick - IR 05000324/2015002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Brunswick) @ 2015Q2
Self-Identified List (Brunswick)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||