WEEKMONTHYEAR05000373/LER-2024-003-01, Supplement to Technical Specification (TS) Limiting Condition for Operation (LCO) 3.6.1.3 Completion Time Exceeded2024-07-310Start date: 31 July 2024 Site: LaSalle Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000373/LER-2024-003, Technical Specification (TS) Limiting Condition for Operation (LCO) 3.6.1.3 Completion Time Exceeded2024-06-060Start date: 6 June 2024 Site: LaSalle Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000391/LER-2024-002, Re Automatic Reactor Trip Due to Steam Generator 3 Level LO-LO2024-05-060Start date: 6 May 2024 Site: Watts Bar Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 05000412/LER-2023-003-01, Missile Barrier Door Left Open Resulting in a Loss of Safety Function2024-02-200Start date: 20 February 2024 Site: Beaver Valley Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(viii)(B) 05000412/LER-2023-003, Missile Barrier Door Left Open Resulting in a Loss of Safety Function2023-08-080Start date: 8 August 2023 Site: Beaver Valley Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000341/LER-2023-001-01, Loss of Mechanical Draft Cooling Tower Fan Brakes During High Speeds Leads to Loss of Safety Function and Inoperability2023-06-230Start date: 23 June 2023 Site: Fermi Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000443/LER-2023-001, Automatic Actuation of B Emergency Diesel Generator Emergency Power Sequencer2023-06-120Start date: 12 June 2023 Site: Seabrook Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000374/LER-1922-003-01, Manual Scram Due to Lsophase Bus Duct Fire Followed by 2A RPS Normal Power Supply Trip2023-02-090Start date: 9 February 2023 Site: LaSalle Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2), 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(1) 05200025/LER-1922-002-01, Automatic Depressurization System Stage 4 Flow Paths Inoperable During Mode 6 with Upper Internals in Place Due to Inadequate Work Processes2023-02-030Start date: 3 February 2023 Site: Vogtle Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000382/LER-2022-001-01, On Non-Compliance with Technical Specifications Due to Incorrect Procedural Guidance for Radiation Monitors2023-01-030Start date: 3 January 2023 Site: Waterford Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000414/LER-2022-003, Manual Reactor Trip and Auxiliary Feedwater System Actuation2022-12-230Start date: 23 December 2022 Site: Catawba Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000296/LER-2022-002, Both Standby Liquid Control Subsystems Inoperable Due to an Insufficient Boron Injection Rate2022-12-190Start date: 19 December 2022 Site: Browns Ferry Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000280/LER-2022-003, Loss of Emergency Switchgear Room Cooling Due to Use of Incorrect Air Handler Fan V-Belts2022-11-110Start date: 11 November 2022 Site: Surry Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000373/LER-2022-003-01, Main Control Room and Auxiliary Electric Room HVAC Declared Inoperable Due to Multiple Component Failures2022-09-230Start date: 23 September 2022 Site: LaSalle Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(x), 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2) 05000416/LER-2022-001, For Grand Gulf Nuclear Station, Unit 1, Manual Reactor Trip Due to the Loss of Balance of Plant Transformer 232022-08-290Start date: 29 August 2022 Site: Grand Gulf Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000263/LER-2022-001, Loss of Control Room Envelope Operability2022-07-070Start date: 7 July 2022 Site: Monticello Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000287/LER-2022-002, Automatic Actuation of Emergency Feedwater System Due to Malfunctioning Startup Feedwater Control Valve2022-07-010Start date: 1 July 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000382/LER-2022-004, Regarding Operation Prohibited by Technical Specifications Due to Inadequate Radiation Monitor Calibration Procedures2022-06-230Start date: 23 June 2022 Site: Waterford Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000270/LER-2022-003, Manual Reactor Trip Due to Main Feedwater Control Valve Positioner Malfunction2022-04-210Start date: 21 April 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000270/LER-2022-002, Regarding Automatic Actuation of Emergency Feedwater System Due to Main Feedwater Pump Malfunction2022-04-140Start date: 14 April 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000270/LER-2022-001, Regarding Automatic Reactor Trip Due to Loss of Power to Reactor Coolant Pumps2022-04-060Start date: 6 April 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000287/LER-2022-001, Response Actions Resulted in Brief Inoperability of Both Onsite and Offsite Emergency AC Power Paths2022-03-280Start date: 28 March 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000388/LER-2021-001-01, Condition Prohibited by Technical Specifications Due to Drift of Reactor Pressure Switch2022-03-210Start date: 21 March 2022 Site: Susquehanna Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000341/LER-2021-002-01, Unplanned Inoperability of High Pressure Coolant Injection System Due to an Inverter Circuit Failure2022-03-150Start date: 15 March 2022 Site: Fermi Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2) 05000389/LER-2022-001, Reactor Shutdown Required by Technical Specifications Due to a Misaligned Control Element Assembly2022-03-040Start date: 4 March 2022 Site: Saint Lucie Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(iv), System Actuation, 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2) 05000270/LER-2021-005, Automatic Reactor Trip Due to Spurious Trip Signal Concurrent with System Testing2022-02-080Start date: 8 February 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000270/LER-2021-004, More than One Axial Power Shaping Rod Not Aligned within Technical Specification Limits2022-02-070Start date: 7 February 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000270/LER-2021-003, Conditions Prohibited by Technical Specifications Due to Ssf and Psw Inoperability2022-02-070Start date: 7 February 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000335/LER-2021-001, Manual Reactor Trip Due to Insufficient Feed Flow to Steam Generators2022-02-040Start date: 4 February 2022 Site: Saint Lucie Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000270/LER-2021-002, Actuation of the Keowee Hydroelectric Station Due to Loss of AC Power to the Unit 2 Main Feeder Buses2022-01-260Start date: 26 January 2022 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000333/LER-2021-003, Air Solenoid Valve Condition Results in Main Steam Isolation Valve (MSIV) Fast Closure Test Failure2022-01-140Start date: 14 January 2022 Site: FitzPatrick Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000389/LER-2021-002, Foreign Material Exclusion Device Found in Containment Spray System2021-11-100Start date: 10 November 2021 Site: Saint Lucie Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2) 05000266/LER-2021-001, Main Feedwater Pump Trip Results in Manual Reactor Trip2021-09-280Start date: 28 September 2021 Site: Point Beach Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(x), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded, 10 CFR 50.73(a)(2)(iii), 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System, 10 CFR 50.73(a)(2)(viii)(A), 10 CFR 50.73(a)(2)(viii)(B) 05000388/LER-2021-001, Condition Prohibited by Technical Specifications Due to Drift of Reactor Pressure Switch2021-09-010Start date: 1 September 2021 Site: Susquehanna Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000289/LER-2017-0042018-02-050Start date: 5 February 2018 Site: Three Mile Island, Three Mile Island Unit 1 Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000266/LER-2017-0012017-09-180Start date: 18 September 2017, 16 November 2017 Site: Point Beach Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000483/LER-2017-0022017-08-150Start date: 15 August 2017, 13 October 2017 Site: Callaway Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 05000346/LER-2017-0012017-07-200Start date: 20 July 2017, 18 September 2017 Site: Davis Besse Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000382/LER-2017-0022017-07-170Start date: 17 July 2017, 18 September 2017 Site: Waterford, Waterford Steam Electric Station, Unit 3 Reporting criterion: 10 CFR 50.73(a)(2)(iv)(A), System Actuation, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000334/LER-2017-0022017-07-190Start date: 19 July 2017, 13 September 2017 Site: Beaver Valley Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000298/LER-2017-0052017-08-170Start date: 17 August 2017 Site: Cooper Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000286/LER-2017-0012017-05-140Start date: 14 May 2017, 13 July 2017 Site: Indian Point, Indian Point Unit 3 Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000334/LER-2017-0012017-02-030Start date: 3 February 2017, 18 April 2017 Site: Beaver Valley Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 05000277/LER-2017-0012017-03-080Start date: 8 March 2017 Site: Peach Bottom Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000445/LER-2016-0022017-02-220Start date: 22 February 2017 Site: Comanche Peak Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 05000390/LER-2017-0012016-11-100Start date: 10 November 2016, 14 February 2017 Site: Watts Bar Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000341/LER-2016-0012016-01-060Start date: 6 January 2016, 23 January 2017 Site: Fermi Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000400/LER-2016-0012016-07-070Start date: 7 July 2016, 1 September 2016 Site: Harris Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000317/LER-2016-0042015-11-130Start date: 13 November 2015, 20 July 2016 Site: Calvert Cliffs Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000293/LER-2016-0022016-04-190Start date: 19 April 2016, 20 June 2016 Site: Pilgrim, Pilgriin Nuclear Power Station Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 05000391/LER-2016-0012016-04-140Start date: 14 April 2016, 13 June 2016 Site: Watts Bar Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000247/LER-2016-0072016-06-100Start date: 10 June 2016 Site: Indian Point Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000346/LER-2016-0042016-04-050Start date: 5 April 2016, 6 June 2016 Site: Davis Besse Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000333/LER-2016-0022016-02-250Start date: 25 February 2016, 25 April 2016 Site: FitzPatrick Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000341/LER-2016-0022016-03-220Start date: 22 March 2016 Site: Fermi Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000261/LER-2016-0012016-01-190Start date: 19 January 2016, 21 March 2016 Site: Robinson Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(i) 05000333/LER-2015-0082015-12-180Start date: 18 December 2015, 16 February 2016 Site: FitzPatrick Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000331/LER-2015-0022015-03-310Start date: 31 March 2015, 28 January 2016 Site: Duane Arnold Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000259/LER-2015-0052015-10-290Start date: 29 October 2015 Site: Browns Ferry Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000275/LER-2015-0022015-10-050Start date: 5 October 2015 Site: Diablo Canyon Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000247/LER-2015-0022015-08-180Start date: 18 August 2015 Site: Indian Point Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000400/LER-2015-0052015-06-160Start date: 16 June 2015 Site: Harris Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 05000266/LER-2015-0042015-06-040Start date: 4 June 2015 Site: Point Beach Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000298/LER-2015-0032015-05-300Start date: 30 May 2015 Site: Cooper Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000400/LER-2015-0022015-04-040Start date: 4 April 2015 Site: Harris Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000298/LER-2015-0022015-02-190Start date: 19 February 2015 Site: Cooper Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000261/LER-2015-0012015-01-280Start date: 28 January 2015 Site: Robinson Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000286/LER-2015-0012015-01-080Start date: 8 January 2015 Site: Indian Point Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000286/LER-2015-001, Safety System Functional Failure Due to Inoperable Refueling Water Storage Tank Level Alarms Due to Freezing of the Level Instrument Sensing Lines Caused by a Failed Strip Heater2015-01-080Start date: 8 January 2015 Site: Indian Point Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000275/LER-2015-001, Both Trains of Residual Heat Removal Inoperable Due to Circumferential Crack on a Socket Weld2014-12-310Start date: 31 December 2014 Site: Diablo Canyon Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000382/LER-2014-0042014-10-220Start date: 22 October 2014 Site: Waterford Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000323/LER-2014-0022014-08-140Start date: 14 August 2014 Site: Diablo Canyon Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown 05000389/LER-2014-0012014-07-250Start date: 25 July 2014 Site: Saint Lucie Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i), 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 05000458/LER-2014-0032014-06-100Start date: 10 June 2014 Site: River Bend Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(b), 10 CFR 50.73(a)(2)(i) 05000285/LER-2014-0042014-04-240Start date: 24 April 2014 Site: Fort Calhoun Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(ix)(A), Prevented Safety Function in Multiple System 05000443/LER-2014-0022014-04-060Start date: 6 April 2014 Site: Seabrook Reporting criterion: 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000317/LER-2014-0032014-02-280Start date: 28 February 2014 Site: Calvert Cliffs Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000263/LER-2014-0042014-02-100Start date: 10 February 2014 Site: Monticello Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000272/LER-2014-0012014-01-070Start date: 7 January 2014 Site: Salem Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000244/LER-2013-0032013-09-200Start date: 20 September 2013 Site: Ginna Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000286/LER-2013-0022013-03-040Start date: 4 March 2013 Reporting criterion: 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 05000269/LER-2013-0012013-02-060Start date: 6 February 2013 Site: Oconee Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000250/LER-2013-0012013-01-030Start date: 3 January 2013 Site: Turkey Point Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000382/LER-2013-0032012-11-160Start date: 16 November 2012 Site: Waterford Reporting criterion: 10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat, 10 CFR 50.73(a)(2)(v)(D), Loss of Safety Function - Mitigate the Consequences of an Accident, 10 CFR 50.73(a)(2)(v), Loss of Safety Function, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(ii)(b), 10 CFR 50.73(a)(2)(ix), 10 CFR 50.73(a)(2)(i)(C), 50.54(x) TS Deviation 05000352/LER-2012-0082012-09-130Start date: 13 September 2012 Site: Limerick Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 05000352/LER-2012-0072012-08-200Start date: 20 August 2012 Site: Limerick Reporting criterion: 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition, 10 CFR 50.73(a)(2)(v)(C), Loss of Safety Function - Release of Radioactive Material, 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications, 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 05000352/LER-2012-0042012-07-110Start date: 11 July 2012 Site: Limerick Reporting criterion: 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability, 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications
[Table view] |