05000498/FIN-2009002-03
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Inadequate Surveillance Test for Component Cooling Water |
| Description | The inspectors identified a noncited violation of 10 CFR Part 50, Appendix B, Criteria V, Instructions, Procedures, and Drawings, for the inadequate surveillance Procedure 0PSP05-CC-0001, FCI CCW Surge Tank Compartment Level Switch Calibration, Revision 7. On October 14, 2008, during the 18-month surveillance test, Unit 2 component cooling water Train A was determined to be inoperable due to the failure of system valves to actuate to their designated positions. Troubleshooting determined that a loose wire was the reason for the inoperability. The wire was restored and the train returned to operable status on October 16, 2008. From January 22 through October 16, 2008, the Train A component cooling water low-low level switch was inoperable. Since this procedure is applicable to all trains of both units, the licensee verified that all other trains low-low level switches on both units were either surveillance tested after the last calibration procedure or were functionally checked using a temporary procedure to ensure operability. The finding was more than minor because it was similar to several examples in Inspection Manual Chapter 0612, Appendix E, where the system was returned to service without being fully operable, and it affected the Mitigating Systems cornerstone attribute of procedure quality and the objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Using the Significance Determination Process Phase 1 worksheets from Inspection Manual Chapter 0609, the finding was determined to have very low safety significance because it did not result in the actual loss of safety function of one or more trains and it did not screen as risk significant due to seismic, flooding, fire, or severe weather. This issue had no crosscutting aspects because the last revision to the procedure was too long ago (2005) to be indicative of current performance (Section 1R22) |
| Site: | South Texas |
|---|---|
| Report | IR 05000498/2009002 Section 1R22 |
| Date counted | Jun 30, 2009 (2009Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.22 |
| Inspectors (proximate) | J Dixon B Tharakan S Graves J Adams W Walker W Sifre B Larson C Ryan |
| INPO aspect | |
| ' | |
Finding - South Texas - IR 05000498/2009002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (South Texas) @ 2009Q2
Self-Identified List (South Texas)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||