05000482/LER-1917-001, Regarding Condition Prohibited by Technical Specifications Due to One Train of Component Cooling Water Inoperable

From kanterella
(Redirected from 05000482/LER-2017-001)
Jump to navigation Jump to search
Regarding Condition Prohibited by Technical Specifications Due to One Train of Component Cooling Water Inoperable
ML17143A233
Person / Time
Site: Wolf Creek 
Issue date: 05/17/2017
From: Shawn Smith
Wolf Creek
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
WO 17-0047 LER 17-001-00
Download: ML17143A233 (4)


LER-1917-001, Regarding Condition Prohibited by Technical Specifications Due to One Train of Component Cooling Water Inoperable
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications

10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded

10 CFR 50.73(a)(2)(viii)(A)

10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition

10 CFR 50.73(a)(2)(viii)(B)

10 CFR 50.73(a)(2)(ix)(A)

10 CFR 50.73(a)(2)(iv)(A), System Actuation

10 CFR 50.73(a)(2)(x)

10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor

10 CFR 50.73(a)(2)(v)(B), Loss of Safety Function - Remove Residual Heat

10 CFR 50.73(a)(2)(v), Loss of Safety Function

10 CFR 50.73(a)(2)(i)(A), Completion of TS Shutdown

10 CFR 50.73(a)(2)(vii), Common Cause Inoperability

10 CFR 50.73(a)(2)(i)
4821917001R00 - NRC Website

text

,~LFCREEK

'NUCLEAR OPERATING CORPORATION Stephen L. Smith Plant Manager U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555 May 17, 2017 WO 17-0047

Subject:

Docket No. 50-482: License Event Report (LER) 2017-001-00, "Condition Prohibited by Technical Specifications Due to One Train of Component Cooling Water Inoperable" To Whom It May Concern:

The enclosed Licensee Event Report (LER) 2017-001-00 is being submitted pursuant to 10 CFR 50.73(a)(2)(i)(B).

This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-4093, or Cynthia R.

  • Hafenstine (620) 364-4204.

SLS/rlt

Enclosure:

LER 2017-001-00 cc:

K. M.. Kennedy (NRG), w/e B. K. Singal (NRG}, w/e N. H. Taylor (NRG}, w/e Senior Resident Inspector (NRG), w/e Sincerely, Stephen L. Smith P.O. Box 411 I Burlington, KS 66839 I Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HCNET

NRC FORM 366 U.S. NUCLEAR REGULATORY COMMISSION APPROVED BY OMB: NO. 3150-0104 EXPIRES: 03/31/2020 (04-2017) http* Lfwww. nrc. g Qv/read ing-rm/d QQ-col lecti Qns/nuregs/s!aff/sr1 022/r3D the NRG may not conduct or sponsor, and a person is not required to respond to, the information collection.

3. PAGE Wolf Creek Generating Station 05000 482 1 OF

.3

4. TITLE Condition Prohibited by Technical Specifications Due to One Train of Component Cooling Water Inoperable
5. EVENT DATE
6. LER NUMBER
7. REPORT DATE
8. OTHER FACILITIES INVOLVED I

SEQUENTIAL I REV FACILITY NAME DOCKET NUMBER MONTH DAY YEAR YEAR MONTH DAY YEAR NUMBER NO.

05000 FACILITY NAME DOCKET NUMBER 03 22 2017 2017 -

001 -

00 05 17 2017 05000

9. OPERATING MODE
11. THIS REPORT IS SUBMITTED PURSUANT TO THE REQUIREMENTS OF 10 CFR §: (Check all that apply)

D 20.2201 (b)

D 20.2203(a)(3)(i)

D 50.73(a)(2)(ii)(A)

D 50.73(a)(2)(viii)(A) 1 D 20.2201(d)

D 20.2203(a)(3)(ii)

D 50.73(a)(2)(ii)(B)

D 50.73(a)(2)(viii)(B)

D 20.2203(a)(1)

D 20.2203(a)(4)

D so.73(a)(2)(iii)

D 50.73(a)(2)(ix)(A)

\\.,

D 20.2203(a)(2)(i)

D 50.36(c)(1)(i)(A)

D 50.73(a)(2)(iv)(A)

D 50.73(a)(2)(x)

10. POWER LEVEL D 20.2203(a)(2)(ii)

D 50.36(c)(1)(ii)(A)

D 50.73(a)(2)(v)(A)

D 73.71(a)(4)

D 20.2203(a)(2)(iii)

D so.36(c)(2)

D 50.73(a)(2)(v)(B)

D 73.71(a)(5)

D 20.2203(a)(2)(iv)

D so.46(a)(3)(ii)

D 50.73(a)(2)(v)(C)

D 73.77(a)(1) 100 D 20.2203(a)(2)(v)

D 50.73(a)(2)(i)(A)

D 50.73(a)(2)(v)(D)

D 73.77(a)(2)(i)

D 20.2203(a)(2)(vi)

[{] 50.73(a)(2)(i)(B)

D 50.73(a)(2)(vii)

D 73.77(a)(2)(ii)

,.ii;~;
  • , i~=z~¥:;

D 50.73(a)(2)(i)(C)

D OTHER Specify in Abstract below or in

CORRECTIVE ACTIONS

Training Request 2017-0098 was written for the License Requalification program and the Initial License Operator program to present the new guidance for declaring a CCW train inoperable when ESW cannot be aligned for makeup from the Control Room. Essential Reading 2017-013 was issued for licensed personnel.

TS Bases 3.7.7 will be revised to state that if emergency makeup from ESW is unavailable, then the CCW train is inoperable. This action is being tracked by Condition Report (CR) 111808.

SAFETY SIGNIFICANCE

The safety significance of this event is very low. The "B" CCW train was available during the time the "A" train was inoperable. In addition, the "A" train CCW was functional and in operation during the event.

OPERATING EXPERIENCE/PREVIOUS EVENTS None. Page 3

of 3