Finding | |
|---|---|
| Title | Failure to Obtain Prior NRC Approval for a Change in Reactor Core Isolation Cooling Injection Point |
| Description | Green. The NRC identified a Severity Level IV violation for the licensees failure to restore compliance for a non-cited violation (NCV) associated with failure to obtain NRC approval prior to making a change to the reactor core isolation cooling injection point. Specifically, as of April 28, 2017, the licensee had not restored compliance with a violation the NRC identified on October 8, 2015. This violation described a previously made change to the facility without prior NRC approval in violation of 10 CFR 50.59, Changes, Tests, and Experiments. The team determined that the licensees failure to restore compliance within a reasonable amount of time was a performance deficiency. Title 10 CFR 50, Appendix B, Criterion XVI, requires in part that, measures shall be established to assure that conditions 3 adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective material and equipment, and nonconformances are promptly identified and corrected. The licensee entered this issue into their corrective action program as Condition Report CR-RBS-2017-03505. The finding was more than minor because it is associated with the initiating events aspect of the reactor safety cornerstone and affected the cornerstone objective to limit the likelihood of events that upset plant stability and challenge critical safety functions during power operations. The finding is of very low safety significance (Green) because it did not cause a reactor trip and the loss of mitigation equipment relied upon to transition the plant from the onset of the trip to a stable shutdown condition. The finding has a human performance cross-cutting aspect associated with procedural adherence because individuals failed to follow the procedures delineated by the corrective action program [H.8]. Originally, the licensee met the criteria for dispositioning the issue (50.59) as a NCV. However, based upon the fact that the condition report, which documented the NCV, was closed without restoring compliance, the licensee no longer met the criteria for a NCV and therefore, this violation is being cited in a notice of violation |
| Site: | River Bend |
|---|---|
| Report | IR 05000458/2017009 Section 4OA2 |
| Date counted | Jun 30, 2017 (2017Q2) |
| Type: | Violation: Green |
| cornerstone | Initiating Events |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | R Azua P Jayroe B Parks T Hipschman |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50.59 |
| CCA | H.8, Procedure Adherence |
| INPO aspect | WP.4 |
| ' | |
Finding - River Bend - IR 05000458/2017009 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (River Bend) @ 2017Q2
Self-Identified List (River Bend)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||