Finding | |
|---|---|
| Title | Failure to Properly Install Insulation Results in Frozen Feedwater Flow Sensing Lines |
| Description | The inspectors reviewed a self-revealing finding for the licensees failure to provide adequate instructions to maintenance personnel when installing insulation on feedwater flow sensing lines. As a result, three sensing lines froze and caused a feedwater perturbation that required operators to take control of the system to stabilize the plant. This finding does not involve enforcement action because no regulatory requirement violation was identified. The licensee entered the finding into the corrective action program as Condition Report CR-2011-001224. The licensees failure to provide adequate instructions for the installation of insulation on feedwater flow sensing lines was a performance deficiency. The finding was more than minor because it was associated with the equipment performance attribute of the initiating events cornerstone and adversely affected the cornerstone objective, in that, it increased the likelihood of those events that upset plant stability and challenge critical safety functions during power operations. Using NRC Manual Chapter 0609, Attachment 4, Phase 1 - Initial Screening and Characterization of Findings, the finding was determined to be of very low safety significance because the finding did not contribute to both the likelihood of a reactor trip and the likelihood that mitigating equipment would not be available. The finding did not have a crosscutting aspect because it was not representative of current licensee performance. |
| Site: | Comanche Peak |
|---|---|
| Report | IR 05000445/2011003 Section 1R01 |
| Date counted | Jun 30, 2011 (2011Q2) |
| Type: | Finding: Green |
| cornerstone | Initiating Events |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71111.01 |
| Inspectors (proximate) | B Tindell D Proulx G Tutak J Kramer R Kopriva W Walker |
| INPO aspect | |
| ' | |
Finding - Comanche Peak - IR 05000445/2011003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Comanche Peak) @ 2011Q2
Self-Identified List (Comanche Peak)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||