Finding | |
|---|---|
| Title | Failure to Control Transient Combustible Material in Accordance with a Fire Protection Procedure |
| Description | The inspectors identified a non-cited violation of License Condition 2.C(41), Fire Protection Program, for the failure to control transient combustibles in accordance with a fire protection program procedure. On August 13, 2014, the inspectors identified unattended transient combustible material stored within a combustible exclusion zone in Fire Zone 1A222 of the auxiliary building 119 elevation. The inspectors reported the occurrence to the operations shift manager and determined licensee personnel had not performed a transient combustible evaluation of the contents of the carts. The licensee documented this issue in Condition Report CR-GGN-2014-05842. As an immediate corrective action, the licensee moved the material to an appropriate designated area. The failure to control transient combustible material in accordance with the approved fire protection program is a performance deficiency. The performance deficiency was more than minor and therefore a finding because it was associated with the protection against external factors attribute of the Mitigating System Cornerstone and adversely affected the cornerstone objective in that the transient combustible materials decreased the external event mitigation for fire prevention. Using NRC Inspection Manual Chapter 0609, Attachment 4, Initial Characterization of Findings, June 19, 2012, the inspectors determined that the issue affected the Mitigation Systems Cornerstone and that the finding pertained to a failure to adequately implement fire prevention and administrative controls for transient combustible materials. As a result, the inspectors were directed to Inspection Manual Chapter 0609, Appendix F, Fire Protection Significance Determination Process, September 20, 2013. The inspectors evaluated the finding through Appendix F, Attachment 1, Fire Protection Significance Determination Process Worksheet, September 20, 2013, and determined that the finding was of very low safety consequence (Green) because the Fire Prevention and Administrative Controls finding would not prevent the reactor from reaching and maintaining a safe shutdown condition. The apparent cause of this finding was incorrect assumptions and mental shortcuts or biases. This finding had a cross-cutting aspect in the human performance area associated with conservative bias, in that licensee staff failed to use decision making-practices that emphasize prudent choices over those that are simply allowable [H.14]. |
| Site: | Grand Gulf |
|---|---|
| Report | IR 05000416/2014004 Section 1R04 |
| Date counted | Sep 30, 2014 (2014Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.04 |
| Inspectors (proximate) | B Baca B Parks B Rice G George M Williams P Nizov |
| Violation of: | License Condition - Fire Protection License Condition |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |