05000382/FIN-2015004-01
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to Properly Pre-Plan and Perform Maintenance on the Core Element Assembly Calculators |
Description | The inspectors reviewed a self-revealing, non-cited violation of Technical Specification 6.8.1.a, associated with the licensees failure to properly pre-plan and perform maintenance in accordance with EN-DC-153, Preventative Maintenance Component Classification. The licensee entered this condition into their corrective action program as condition report CR-WF3-2015-06438. The licensee restored compliance by properly classifying the components as High Critical in accordance with EN-DC-153, Revision 2, and by initiating development of appropriate preventative-maintenance for the control element assembly calculators (CEACs). In addition, the licensee initiated work to improve the reliability of the CEACs, including reviewing card refurbishments to ensure circuit card reliability is enhanced. The performance deficiency was more than minor because it is associated with the Equipment Performance attribute of the Initiating Events Cornerstone and adversely affected the cornerstone objective to limit the likelihood of events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Specifically, inappropriate preventative maintenance on the circuit cards associated with the CEACs ultimately resulted in a plant trip on October 3, 2015. The inspectors screened the finding in accordance with NRC Inspection Manual Chapter (IMC) 0609, Significance Determination Process. Using IMC 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, the inspectors determined that the finding was of very low significance (Green) because the finding did not cause a trip and the loss of mitigation equipment relied upon to transition the plant from the onset of the trip to a stable shutdown condition. Because the performance deficiency occurred in 2008, the inspectors concluded that the finding does not reflect current licensee performance and therefore did not assign a cross-cutting aspect. |
Site: | Waterford |
---|---|
Report | IR 05000382/2015004 Section 1R12 |
Date counted | Dec 31, 2015 (2015Q4) |
Type: | NCV: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71111.12 |
Inspectors (proximate) | C Speer F Ramirez I Anchondo J Sowa M Phalen N Greene T Sullivan J Choate |
Violation of: | Technical Specification Technical Specification - Procedures |
INPO aspect | |
' | |
Finding - Waterford - IR 05000382/2015004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Waterford) @ 2015Q4
Self-Identified List (Waterford)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||