Finding | |
|---|---|
| Title | Failure to Identify and Evaluate Elevated Bus Voltages |
| Description | The team identified a Green non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, which states, in part, that measures shall be established to assure that conditions adverse to quality, such as failures, malfunctions, deficiencies, deviations, defective material and equipment, and nonconformance are promptly identified and corrected. Specifically, from October 27 through December 13, 2012, and on May 1, 2014, the licensee failed to identify and evaluate the impact of elevated bus voltages that exceeded the allowable voltage on the 480 VAC Class 1E Bus 3B31, a condition adverse to quality. In response to this issue, the licensee completed an operability determination with plans to evaluate any trends requiring additional actions. This finding was entered into the licensees corrective action program as Condition Report CR-WF3-2014-05458. The team determined that the failure to identify and evaluate the impact of elevated bus voltages was a performance deficiency. This performance deficiency was more than minor because it was associated with the equipment performance attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to events to prevent undesirable consequences. Specifically, the licensee failed to identify and evaluate elevated voltages on the 480 VAC Class 1E Bus 3B31 that exceeded allowable operability limits. In accordance with Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, dated June 19, 2012, Exhibit 2, Mitigating Systems Screening Questions, this finding screened as having very low safety significance (Green) because it was a design or qualification deficiency that did not represent a loss of operability or functionality; did not represent an actual loss of safety function of the system or train; did not result in the loss of one or more trains of non- technical specification equipment; and did not screen as potentially risk-significant due to seismic, flooding, or severe weather. This finding had a cross-cutting aspect in the area of problem identification and resolution associated with trending because the licensee failed to periodically analyze information in the aggregate to identify programmatic and common cause issues (P.4). |
| Site: | Waterford |
|---|---|
| Report | IR 05000382/2014007 Section 1R21 |
| Date counted | Mar 31, 2015 (2015Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | B Larson E Ruesch G Gardner G Ottenberg P Wagner S Makor |
| Violation of: | 10 CFR 50 Appendix B Criterion XVI Technical Specification |
| CCA | P.4, Trending |
| INPO aspect | PI.4 |
| ' | |
Finding - Waterford - IR 05000382/2014007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Waterford) @ 2015Q1
Self-Identified List (Waterford)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||