05000373/FIN-2011008-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Technical Specification Violation Due to Failures to Follow Operability Determinations Procedure |
| Description | A finding of very low safety significance (Green) and associated non-cited violation of Technical Specifications (TS) was identified by the inspectors for the licensees failure to follow station procedure OP-AA-108-115, Operability Determinations, Revisions 8 and 10. Specifically, the licensee failed to follow their operability determination procedure during loss of shutdown cooling (SDC) events occurring on July 20, 2009, and February 2, 2011. These events were caused by the closure of the residual heat removal (RHR) common suction valve. These events also resulted in the violation of TS 3.4.9, 3.4.10, and 3.0.2. The licensee entered this issue into its CAP as Issue Report (IR) 1248293. The finding was considered more than minor because it was associated with the Mitigating Systems Cornerstone attribute of Equipment Performance and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Specifically, failing to follow the Operability Determinations procedure caused the licensee to incorrectly assess the RHR SDC systems capability to perform its safety function, and also led the licensee to make a specific TS required isolation feature unavailable. This finding has a cross-cutting aspect in the area of human performance, decision making, because the licensee used non-conservative assumptions when confronted with unexpected system failures. |
| Site: | LaSalle |
|---|---|
| Report | IR 05000373/2011008 Section 4OA2 |
| Date counted | Sep 30, 2011 (2011Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | R Edwards N Shah R Ruiz K Riemer J Yesinowski P Smagacz |
| CCA | H.14, Conservative Bias |
| INPO aspect | DM.2 |
| ' | |
Finding - LaSalle - IR 05000373/2011008 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (LaSalle) @ 2011Q3
Self-Identified List (LaSalle)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||