05000348/LER-1979-023-01, /01T-0 on 790622:notified by Westinghouse That High Energy Line Break Inside Containment Could Cause Heatup of Steam Generator Level Transmitter Ref Legs. LER Will Be Issued Upon Completion of Investigation

From kanterella
(Redirected from 05000348/LER-1979-023-01)
Jump to navigation Jump to search
/01T-0 on 790622:notified by Westinghouse That High Energy Line Break Inside Containment Could Cause Heatup of Steam Generator Level Transmitter Ref Legs. LER Will Be Issued Upon Completion of Investigation
ML19224C950
Person / Time
Site: Farley 
Issue date: 07/06/1979
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19224C943 List:
References
LER-79-023-01T, LER-79-23-1T, NUDOCS 7907100295
Download: ML19224C950 (1)


LER-1979-023, /01T-0 on 790622:notified by Westinghouse That High Energy Line Break Inside Containment Could Cause Heatup of Steam Generator Level Transmitter Ref Legs. LER Will Be Issued Upon Completion of Investigation
Event date:
Report date:
3481979023R01 - NRC Website

text

a NRC FORM ;GG 17 77)

LICENSEE 5iVENT REPORT

!h (PLEASE PRINT OR TYP6 ALL REQUtRED INFORMATION)

CCNTROL BLOCK: l 1

l l

l l

3 0

O!OI_ nlnl@l4 1l1l1l1l@l l

l@

AlL J lM lF l1 hl Ol 0l -I Ol 0 0

0 1

i 3 ;

L:CEN5EE CCDE 14 15 LICENSE NWdiq 25 26 LICENSE TYPE J0 57 CAT %

CCW T En"c[lL}@;0l5 l 0] O j 01 3l 4 l 8 '@l 01 6 l 2 l 2 l 7 l 9 hln 17 l0 l 6 l.2_lS_jh U

4 EJ ol UCC(ET Nu

5. ', R G

t> )

E% ENT DATE 74 15 HEPORT OAT 6 80 s

EVENT DESCmPTION AND PROB A9tE CCNGECUENCES h o

2 l Westinghouse notified Alabam Power Company that a high ennrgy ling bro,k 4,cian I

, : l Contain=ent could result in heatup c f the c team 2enera tor level tranvi* ra* e #a"a"-a I

l legs.

A resulting error in steam Fenerator level indication in rh n nnn-cc,sor-,H en !

o a

l a 15 I I direction could occur that could af fect reactor trip and auxiliary feedwater I

I a agenr,1,,einn r,

Linitiation signals. Review of ests no tification resuirna 1, la 6

l 6/12/ 79 that this condition is potentially recortable under Tn-h. %n c. 6_9_1 EM i

o i

o 9

l The health and safety of the oub H-ve rn nor,ffacrad-7 8 9 SYSTEM

CAUSE

CAUSE COMP.

VALVE CCOE CODE SUGCODE COMPCNENT CODE SU8 CODE SUBOODE 01'3!

ZI Zl h d h W h l7 l7l7I? 17ld h W h d h 7

8 9

10 11 12 IJ 18 19 20 SEQUEN TI AL CCCUARENCE REPOHT REVISION LE R HO EVENT YEAR REPORT NO.

CODE TYPE N O.

O aE l719l l-I I Ol?l3l l/l 10 1 l Tl l-l l9_]

Nu E 21 22 23 24 2ti 21 28 29 30 31 32 ACTION FUTUAE EFFECT SHuTOCwN A TT AC wY E N T NPR D-4 PRIME COMP.

COMPON EN T SUB MI TT E D FORMbu9 SUPPLIER MANUFACTURER TAKEN ACi t ON ON Pt, AN T YETHOO HOURS o

WhWh l35_rj@ [2]h I o I O l 0 l 0 l ll{J h

[_Ejh lL]h lZ l9 l9 l9 lh 3J 34 30 3

40 41 42 43 44 47 CAU3E DESCRIPTION AND CORRECTIVE ACTICNS i

O l Increased reference leg water column teen. will result in a dt :rease of the wa ter 1

i 1

l column density with a consecuen t appa_ren t increase in the indicated 9 A v,e-T ovn1 1 [i[,j [

(i.e. apparent level exceeding actual level). This matter is under investigation.

]

l A supplemental LE17 vill be issued upon co=pletion of the investigation.

l i

i l

82 7

s 3 UETHCOCF

AClLcv STArus

%8CWER CTHER STA TUS DISCO % ER Y DISCOVERY DESC3lPTION a

NA l

lDl@l Notification from NSSS vendor l

lc l@ l 0, O l 0 l@l p

s 7

d 1 to 12 11 44 45 46 80 AC Tiv t TY CONTENT fdLE ASED OF AELE ASE WOUNT CF ACT st TY -

LOCATION CF RELEAOE M

NA l

b hh t

4 3 10 it 44 45 30 PECONNE; EMPCSLRES NuY9ER TYPE CESCRIP i lON '

'l1 [0l0I0!h d hi NA

=EnscNNE t N;u'd ES se..u E n OESCniP T'0%

k0 l0 l 0 Ih,2 M

ooc-so 3,

"/d TO F ACI Lt TY 7 9 0 7 ; n., N r F Los; or ca JA.t AGE,CN Tm m.T i

h 1

3 NA g

pai$Tr NRC USE CNLY mu E O@ c E SC RIPTsON

[

,IIIII'llIII g

W l

m 2

o i

d 9 10 W. G. H 1.rston, III (205) 899-5156 g

NAME OF PHEPAREA p g g g+.

o

.) i